Temperature-dependent magnetic particle imaging with multi-harmonic lock-in detection
Authors:
Thinh Q. Bui,
Mark-Alexander Henn,
Weston L. Tew,
Megan A. Catterton,
Solomon I. Woods
Abstract:
Advances in instrumentation and tracer materials are still required to enable sensitive and accurate 3D temperature monitoring by magnetic particle imaging. We have developed a magnetic particle imaging instrument to observe temperature variations using MPI, and discuss resolution dependence on temperature and harmonic number. Furthermore, we present a low noise approach using lock-in detection fo…
▽ More
Advances in instrumentation and tracer materials are still required to enable sensitive and accurate 3D temperature monitoring by magnetic particle imaging. We have developed a magnetic particle imaging instrument to observe temperature variations using MPI, and discuss resolution dependence on temperature and harmonic number. Furthermore, we present a low noise approach using lock-in detection for temperature measurement, and discuss implications for a new detection modality of MPI.
△ Less
Submitted 20 January, 2023;
originally announced January 2023.
-
JILA SrI Optical Lattice Clock with Uncertainty of $2.0 \times 10^{-18}$
Authors:
Tobias Bothwell,
Dhruv Kedar,
Eric Oelker,
John M. Robinson,
Sarah L. Bromley,
Weston L. Tew,
Jun Ye,
Colin J. Kennedy
Abstract:
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reducti…
▽ More
We report on an improved systematic evaluation of the JILA SrI optical lattice clock, achieving a nearly identical systematic uncertainty compared to the previous strontium accuracy record set by the JILA SrII optical lattice clock (OLC) at $2.1 \times 10^{-18}$. This improves upon the previous evaluation of the JILA SrI optical lattice clock in 2013, and we achieve a more than twenty-fold reduction in systematic uncertainty to $2.0 \times 10^{-18}$. A seven-fold improvement in clock stability, reaching $4.8 \times 10^{-17}/\sqrtτ$ for an averaging time $τ$ in seconds, allows the clock to average to its systematic uncertainty in under 10 minutes. We improve the systematic uncertainty budget in several important ways. This includes a novel scheme for taming blackbody radiation-induced frequency shifts through active stabilization and characterization of the thermal environment, inclusion of higher-order terms in the lattice light shift, and updated atomic coefficients. Along with careful control of other systematic effects, we achieve low temporal drift of systematic offsets and high uptime of the clock. We additionally present an improved evaluation of the second order Zeeman coefficient that is applicable to all Sr optical lattice clocks. These improvements in performance have enabled several important studies including frequency ratio measurements through the Boulder Area Clock Optical Network (BACON), a high precision comparison with the JILA 3D lattice clock, a demonstration of a new all-optical time scale combining SrI and a cryogenic silicon cavity, and a high sensitivity search for ultralight scalar dark matter.
△ Less
Submitted 13 June, 2019;
originally announced June 2019.
-
Improved electronic measurement of the Boltzmann constant by Johnson noise Thermometry
Authors:
Jifeng Qu,
Samuel P Benz,
Alessio Pollarolo,
Horst Rogalla,
Weston L Tew,
Rod White,
Kunli Zhou
Abstract:
The unit of thermodynamic temperature, the kelvin, will be redefined in 2018 by fixing the value of the Boltzmann constant, k. The present CODATA recommended value of k is determined predominantly by acoustic gas-thermometry results. To provide a value of k based on different physical principles, purely electronic measurements of k were performed by using a Johnson noise thermometer to compare the…
▽ More
The unit of thermodynamic temperature, the kelvin, will be redefined in 2018 by fixing the value of the Boltzmann constant, k. The present CODATA recommended value of k is determined predominantly by acoustic gas-thermometry results. To provide a value of k based on different physical principles, purely electronic measurements of k were performed by using a Johnson noise thermometer to compare the thermal noise power of a 200 Ohm sensing resistor immersed in a triple-point-of-water cell to the noise power of a quantum-accurate pseudo-random noise waveform of nominally equal noise power. Measurements integrated over a bandwidth of 550 kHz and a total integration time of 33 days gave a measured value of k = 1.3806514(48)x10^-23 J/K, for which the relative standard uncertainty is 3.5x10^-6 and the relative offset from the CODATA 2010 value is +1.9x10^-6.
△ Less
Submitted 31 December, 2014;
originally announced January 2015.
-
Systematic evaluation of an atomic clock at 2e-18 total uncertainty
Authors:
T. L. Nicholson,
S. L. Campbell,
R. B. Hutson,
G. E. Marti,
B. J. Bloom,
R. L. McNally,
W. Zhang,
M. D. Barrett,
M. S. Safronova,
G. F. Strouse,
W. L. Tew,
J. Ye
Abstract:
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation, and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. This work takes an important step towards realizing the full potential of a many-…
▽ More
The pursuit of better atomic clocks has advanced many research areas, providing better quantum state control, new insights in quantum science, tighter limits on fundamental constant variation, and improved tests of relativity. The record for the best stability and accuracy is currently held by optical lattice clocks. This work takes an important step towards realizing the full potential of a many-particle clock with a state-of-the-art stable laser. Our 87Sr optical lattice clock now achieves fractional stability of 2.2e-16 at 1 s. With this improved stability, we perform a new accuracy evaluation of our clock, reducing many systematic uncertainties that limited our previous measurements, such as those in the lattice ac Stark shift, the atoms' thermal environment, and the atomic response to room-temperature BBR. Our combined measurements have reduced the total uncertainty of the JILA Sr clock to 2.1e-18 in fractional frequency units.
△ Less
Submitted 6 May, 2015; v1 submitted 29 December, 2014;
originally announced December 2014.
-
An Electronic Measurement of the Boltzmann Constant
Authors:
Samuel P. Benz,
Alessio Pollarolo,
Jifeng Qu,
Horst Rogalla,
Chiharu Urano,
Weston L. Tew,
Paul D. Dresselhaus,
D. Rod White
Abstract:
The Boltzmann constant was measured by comparing the Johnson noise of a resistor at the triple point of water with a quantum-based voltage reference signal generated with a superconducting Josephson-junction waveform synthesizer. The measured value of k = 1.380651(18) \times 10^-23 J/K is consistent with the current CODATA value and the combined uncertainties. This is our first measurement of k wi…
▽ More
The Boltzmann constant was measured by comparing the Johnson noise of a resistor at the triple point of water with a quantum-based voltage reference signal generated with a superconducting Josephson-junction waveform synthesizer. The measured value of k = 1.380651(18) \times 10^-23 J/K is consistent with the current CODATA value and the combined uncertainties. This is our first measurement of k with this electronic technique, and the first noise thermometry measurement to achieve a relative combined uncertainty of 13 parts in 10^6. We describe the most recent improvements to our Johnson Noise Thermometer that enabled the statistical uncertainty contribution to be reduced to seven parts in 10^6, as well as the further reduction of spurious systematic errors and EMI effects. The uncertainty budget for this measurement is discussed in detail.
△ Less
Submitted 31 December, 2010;
originally announced January 2011.