-
Multiplexed wavefront sensing with a thin diffuser
Authors:
Tengfei Wu,
Marc Guillon,
Gilles Tessier,
Pascal Berto
Abstract:
In astronomy or biological imaging, refractive index inhomogeneities of e.g. atmosphere or tissues induce optical aberrations which degrade the desired information hidden behind the medium. A standard approach consists in measuring these aberrations with a wavefront sensor (e.g Shack-Hartmann) located in the pupil plane, and compensating them either digitally or by adaptive optics with a wavefront…
▽ More
In astronomy or biological imaging, refractive index inhomogeneities of e.g. atmosphere or tissues induce optical aberrations which degrade the desired information hidden behind the medium. A standard approach consists in measuring these aberrations with a wavefront sensor (e.g Shack-Hartmann) located in the pupil plane, and compensating them either digitally or by adaptive optics with a wavefront shaper. However, in its usual implementation this strategy can only extract aberrations within a single isoplanatic patch, i.e. a region where the aberrations remain correlated. This limitation severely reduces the effective field-of-view in which the correction can be performed. Here, we propose a new wavefront sensing method capable of measuring, in a single shot, various pupil aberrations corresponding to multiple isoplanatic patches. The method, based on a thin diffuser (i.e a random phase mask), exploits the dissimilarity between different speckle regions to multiplex several wavefronts incoming from various incidence angles. We present proof-of-concept experiments carried out in wide-field fluorescence microscopy. A digital deconvolution procedure in each isoplanatic patch yields accurate aberration correction within an extended field-of-view. This approach is of interest for adaptive optics applications as well as diffractive optical tomography.
△ Less
Submitted 31 May, 2023;
originally announced May 2023.
-
Magnetic nanorods for quantitative viscosity imaging using heterodyne holography
Authors:
C. Gentner,
P. Berto,
J. -F. Berret,
S. Reichman,
R. Kuszelewicz,
G. Tessier
Abstract:
Many processes in microfluidics and biology are driven or affected by viscosity. While several methods are able to measure this parameter globally (AFM, surface acoustic waves, DLS, ...), very few can provide high resolution viscosity images, particularly in living cells. Here, we propose to use sub-micrometer magnetic rods to perform high resolution viscosity imaging. An external magnetic field f…
▽ More
Many processes in microfluidics and biology are driven or affected by viscosity. While several methods are able to measure this parameter globally (AFM, surface acoustic waves, DLS, ...), very few can provide high resolution viscosity images, particularly in living cells. Here, we propose to use sub-micrometer magnetic rods to perform high resolution viscosity imaging. An external magnetic field forces the oscillation of superparamagnetic iron oxide nanorods. Under linearly polarized illumination, the rotation of these highly anisotropic optical scatterers induces a blinking which is analyzed by heterodyne holography. The spectral analysis of the rotation dynamics yields a regime transition frequency f t from which the local viscosity is deduced. Holography provides 3D image reconstruction and 3D superlocalization of the nanorods, which allows super-resolved viscosity measurements. Relying on the fast Brownian rotation of nanorods instead of their slower translation therefore allows faster measurements and, crucially, smaller effective voxels for viscosity determination. Viscosity imaging is demonstrated with a 0.5 μm 3 3D resolution.
△ Less
Submitted 22 March, 2023;
originally announced March 2023.
-
3D Spectroscopic Tracking of Individual Brownian Nanoparticles during Galvanic Exchange
Authors:
Minh-Chau Nguyen,
Pascal Berto,
Fabrice Valentino,
Jean-François Lemineur,
Jean-Marc Noel,
Frédéric Kanoufi,
Gilles Tessier
Abstract:
Monitoring chemical reactions in solutions at the scale of individual entities is challenging: single particle detection requires small confocal volumes which are hardly compatible with Brownian motion, particularly when long integration times are necessary. Here, we propose a real-time (10 Hz) holography-based nm-precision 3D tracking of single moving nanoparticles. Using this localization, the c…
▽ More
Monitoring chemical reactions in solutions at the scale of individual entities is challenging: single particle detection requires small confocal volumes which are hardly compatible with Brownian motion, particularly when long integration times are necessary. Here, we propose a real-time (10 Hz) holography-based nm-precision 3D tracking of single moving nanoparticles. Using this localization, the confocal collection volume is dynamically adjusted to follow the moving nanoparticle and allow continuous spectroscopic monitoring. This concept is applied to the study galvanic exchange in freely-moving collo{ï}dal silver nanoparticles with gold ions generated in-situ. While the Brownian trajectory reveals particle size, spectral shifts dynamically reveal composition changes and transformation kinetics at the single object level, pointing at different transformation kinetics for free and tethered particles.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.
-
Hollow-core fibers with reduced surface roughness and ultralow loss in the short-wavelength range
Authors:
Jonas H. Osório,
Foued Amrani,
Frédéric Delahaye,
Ali Dhaybi,
Kostiantyn Vasko,
Fabio Giovanardi,
Damien Vandembroucq,
Gilles Tessier,
Luca Vincetti,
Benoît Debord,
Frédéric Gérôme,
Fetah Benabid
Abstract:
While optical fibers display excellent performances in the infrared, visible and ultraviolet ranges remain poorly addressed by them. Obtaining better fibers for the short-wavelength range has been restricted, in all fiber optics, by scattering processes. In hollow-core fibers, the scattering loss arises from the core roughness and represents the limiting factor in reducing their loss regardless of…
▽ More
While optical fibers display excellent performances in the infrared, visible and ultraviolet ranges remain poorly addressed by them. Obtaining better fibers for the short-wavelength range has been restricted, in all fiber optics, by scattering processes. In hollow-core fibers, the scattering loss arises from the core roughness and represents the limiting factor in reducing their loss regardless of the fiber cladding confinement power. To attain fibers performing at short wavelengths, it is paramount develo** means to minimize the height variations on the fiber microstructure boundaries. Here, we report on the reduction of the core surface roughness of hollow-core fibers by modifying their fabrication technique. In the novel process proposed herein, counter directional gas fluxes are applied within the fiber holes during fabrication to attain an increased shear rate on its microstructure. The effect of the process on the surface roughness has been quantified by optical profilometry and the results showed that the root-mean-square surface roughness has been reduced from 0.40 nm to 0.15 nm. The improvement in the fiber core surface quality entailed fibers with ultralow loss in the short-wavelength range. We report on fibers with record loss values as low as 50 dB/km at 290 nm, 9.7 dB/km at 369 nm, 5.0 dB/km at 480 nm, and 1.8 dB/km at 719 nm. The results reveal this new approach as a promising path for the development of hollow-core fibers guiding at short wavelengths with loss that can potentially be orders of magnitude lower than the ones achievable with their silica-core counterparts.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
Hollow-core fibers with ultralow loss in the ultraviolet range and sub-thermodynamic equilibrium surface-roughness
Authors:
Jonas H. Osório,
Foued Amrani,
Frédéric Delahaye,
Ali Dhaybi,
Kostiantyn Vasko,
Gilles Tessier,
Fabio Giovanardi,
Luca Vincetti,
Benoît Debord,
Frédéric Gérôme,
Fetah Benabid
Abstract:
We report on hollow-core fibers displaying rms core roughness under the surface capillary waves thermodynamic limit and record loss in the short-wavelength range (50.0 dB/km at 290 nm, 9.7 dB/km at 369 nm, 5.0 dB/km at 480 nm, 0.9 dB/km at 558 nm, 1.8 dB/km at 719 nm).
We report on hollow-core fibers displaying rms core roughness under the surface capillary waves thermodynamic limit and record loss in the short-wavelength range (50.0 dB/km at 290 nm, 9.7 dB/km at 369 nm, 5.0 dB/km at 480 nm, 0.9 dB/km at 558 nm, 1.8 dB/km at 719 nm).
△ Less
Submitted 5 May, 2021;
originally announced May 2021.
-
Topological transformations of speckles
Authors:
Jerome Gateau,
Ferdinand Claude,
Gilles Tessier,
Marc Guillon
Abstract:
Deterministic control of coherent random light is highly important for information transmission through complex media. However, only a few simple speckle transformations can be achieved through diffusers without prior characterization. As recently shown, spiral wavefront modulation of the im**ing beam allows permuting intensity maxima and intrinsic $\pm 1$-charged optical vortices. Here, we stud…
▽ More
Deterministic control of coherent random light is highly important for information transmission through complex media. However, only a few simple speckle transformations can be achieved through diffusers without prior characterization. As recently shown, spiral wavefront modulation of the im**ing beam allows permuting intensity maxima and intrinsic $\pm 1$-charged optical vortices. Here, we study this cyclic-group algebra when combining spiral phase transforms of charge $n$, with $D_3$- and $D_4$-point-group symmetry star-like amplitude modulations. This combination allows statistical strengthening of permutations and controlling the period to be 3 and 4, respectively. Phase saddle-points are shown to complete the cycle. These results offer new tools to manipulate critical points in speckles.
△ Less
Submitted 17 July, 2019; v1 submitted 31 January, 2019;
originally announced January 2019.
-
Anisotropic super-attenuation of capillary waves on driven glass interfaces
Authors:
Bruno Bresson,
Coralie Brun,
Xavier Buet,
Yong Chen,
Matteo Ciccotti,
Jérôme Gâteau,
Greg Jasion,
Marco Petrovich,
Francesco Poletti,
David Richardson,
Seyed Sandoghchi,
Gilles Tessier,
Botond Tyukodi,
Damien Vandembroucq
Abstract:
Metrological AFM measurements are performed on the silica glass interfaces of photonic band-gap fibres and hollow capillaries. The freezing of attenuated out-of-equilibrium capillary waves during the drawing process is shown to result in a reduced surface roughness. The roughness attenuation with respect to the expected thermodynamical limit is determined to vary with the drawing stress following…
▽ More
Metrological AFM measurements are performed on the silica glass interfaces of photonic band-gap fibres and hollow capillaries. The freezing of attenuated out-of-equilibrium capillary waves during the drawing process is shown to result in a reduced surface roughness. The roughness attenuation with respect to the expected thermodynamical limit is determined to vary with the drawing stress following a power law. A striking anisotropic character of the height correlation is observed: glass surfaces thus retain a structural record of the direction of the flow to which the liquid was submitted.
△ Less
Submitted 6 June, 2017;
originally announced June 2017.
-
Trade-offs between spatial and temporal resolutions in stochastic super-resolution microscopy techniques
Authors:
Jean-Francois Rupprecht,
Ariadna Martinez-Marrades,
Rishita Changede,
Gilles Tessier
Abstract:
Widefield stochastic microscopy techniques such as PALM or STORM rely on the progressive accumulation of a large number of frames, each containing a scarce number of super-resolved point images. We justify that the redundancy in the localization of detected events imposes a specific limit on the temporal resolution. Based on a theoretical model, we derive analytical predictions for the minimal tim…
▽ More
Widefield stochastic microscopy techniques such as PALM or STORM rely on the progressive accumulation of a large number of frames, each containing a scarce number of super-resolved point images. We justify that the redundancy in the localization of detected events imposes a specific limit on the temporal resolution. Based on a theoretical model, we derive analytical predictions for the minimal time required to obtain a reliable image at a given spatial resolution, called image completion time. In contrast to standard assumptions, we find that the image completion time scales logarithmically with the ratio of the image size by the spatial resolution volume. We justify that this non-linear relation is the hallmark of a random coverage problem. We propose a method to estimate the risk that the image reconstruction is not complete, which we apply to an experimental data set. Our results provide a theoretical framework to quantify the pattern detection efficiency and to optimize the trade-off between image coverage and acquisition time, with applications to $1$, $2$ or $3$ dimension structural imaging.
△ Less
Submitted 23 February, 2017; v1 submitted 1 March, 2016;
originally announced July 2016.
-
High numerical aperture holographic microscopy reconstruction with extended z range
Authors:
Nicolas Verrier,
Dario Donnarumma,
Gilles Tessier,
Michel Gross
Abstract:
An holographic microscopy reconstruction method compatible with high numerical aperture microscope objective (MO) up to NA=1.4 is proposed. After off axis and reference field curvature corrections, and after selection of the +1 grating order holographic image, a phase mask that transforms the optical elements of the holographic setup into an afocal device is applied in the camera plane. The recons…
▽ More
An holographic microscopy reconstruction method compatible with high numerical aperture microscope objective (MO) up to NA=1.4 is proposed. After off axis and reference field curvature corrections, and after selection of the +1 grating order holographic image, a phase mask that transforms the optical elements of the holographic setup into an afocal device is applied in the camera plane. The reconstruction is then made by the angular spectrum method. The field is first propagated in the image half space from the camera to the afocal image of the MO optimal plane (plane for which MO has been designed) by using a quadratic kernel. The field is then propagated from the MO optimal plane to the object with the exact kernel. Calibration of the reconstruction is made by imaging a calibrated object like an USAF resolution target for different positions along $z$. Once the calibration is done, the reconstruction can be made with an object located in any plane $z$. The reconstruction method has been validated experimentally with an USAF target imaged with a NA=1.4 microscope objective. Near-optimal resolution is obtained over an extended range ($\pm 50~μ$m) of $z$ locations.
△ Less
Submitted 13 November, 2015;
originally announced November 2015.
-
Holographic microscopy reconstruction in both object and image half spaces with undistorted 3D grid
Authors:
Nicolas Verrier,
Danier Alexandre,
Gilles Tessier,
Michel Gross
Abstract:
We propose an holographic microscopy reconstruction method, which propagates the hologram, in the object half space, in the vicinity of the object. The calibration yields reconstructions with an undistorted reconstruction grid i.e. with orthogonal $x$, $y$ and $z$ axis and constant pixels pitch. The method is validated with an USAF target imaged by a $\times$60 microscope objective, whose holog…
▽ More
We propose an holographic microscopy reconstruction method, which propagates the hologram, in the object half space, in the vicinity of the object. The calibration yields reconstructions with an undistorted reconstruction grid i.e. with orthogonal $x$, $y$ and $z$ axis and constant pixels pitch. The method is validated with an USAF target imaged by a $\times$60 microscope objective, whose holograms are recorded and reconstructed for different USAF locations along the longitudinal axis: -75 to +75 $μ$m. Since the reconstruction numerical phase mask, the reference phase curvature and MO form an afocal device, the reconstruction can be interpreted as occurring equivalently in the object or in image half space.
△ Less
Submitted 12 June, 2015; v1 submitted 21 May, 2015;
originally announced May 2015.
-
3D exploration of light scattering from live cells in the presence of gold nanomarkers using holographic microscopy
Authors:
Fadwa Joud,
N. Warnasooriya,
P. Bun,
Frédéric Verpillat,
Sarah Y. Suck,
G. Tessier,
Michael Atlan,
Pierre Desbiolles,
Maite Coppey-Moisan,
Marie Abboud,
Michel Gross
Abstract:
In this paper, we explore the 3D structure of light scattering from dark-field illuminated live 3T3 cells in the presence of 40 nm gold nanomarkers. For this purpose, we use a high resolution holographic microscope combining the off-axis heterodyne geometry and the phase-shifting acquisition of the digital holograms. A comparative study of the 3D reconstructions of the scattered fields allows us t…
▽ More
In this paper, we explore the 3D structure of light scattering from dark-field illuminated live 3T3 cells in the presence of 40 nm gold nanomarkers. For this purpose, we use a high resolution holographic microscope combining the off-axis heterodyne geometry and the phase-shifting acquisition of the digital holograms. A comparative study of the 3D reconstructions of the scattered fields allows us to locate the gold markers which yield, contrarily to the cell structures, well defined bright scattering patterns that are not angularly titled and clearly located along the optical axis (z). This characterization is an unambiguous signature of the presence of gold biological nanomarkers, and validates the capability of digital holographic microscopy to discriminate them from background signals in live ce
△ Less
Submitted 21 December, 2011; v1 submitted 20 December, 2011;
originally announced December 2011.
-
Imaging Gold Nanoparticles in Living Cells Environments using Heterodyne Digital Holographic Microscopy
Authors:
Nilanthi Warnasooriya,
Fadwa Joud,
Philippe Bun,
Gilles Tessier,
Maite Coppey-Moisan,
Pierre Desbiolles,
Michael Atlan,
Marie Abboud,
Michel Gross
Abstract:
This paper describes an imaging microscopic technique based on heterodyne digital holography where subwavelength-sized gold colloids can be imaged in cell environment. Surface cellular receptors of 3T3 mouse fibroblasts are labeled with 40 nm gold nanoparticles, and the biological specimen is imaged in a total internal reflection configuration with holographic microscopy. Due to a higher scatter…
▽ More
This paper describes an imaging microscopic technique based on heterodyne digital holography where subwavelength-sized gold colloids can be imaged in cell environment. Surface cellular receptors of 3T3 mouse fibroblasts are labeled with 40 nm gold nanoparticles, and the biological specimen is imaged in a total internal reflection configuration with holographic microscopy. Due to a higher scattering efficiency of the gold nanoparticles versus that of cellular structures, accurate localization of a gold marker is obtained within a 3D map** of the entire sample's scattered field, with a lateral precision of 5 nm and 100 nm in the x,y and in the z directions respectively, demonstrating the ability of holographic microscopy to locate nanoparticles in living cells environments.
△ Less
Submitted 26 November, 2009;
originally announced November 2009.
-
Heterodyne holographic microscopy of gold particles
Authors:
Michael Atlan,
Michel Gross,
Pierre Desbiolles,
Emilie Absil,
Gilles Tessier,
Maité Coppey-Moisan
Abstract:
We report experimental results on heterodyne holographic microscopy of subwavelength-sized gold particles. The apparatus uses continuous green laser illumination of the metal beads in a total internal reflection configuration for dark-field operation. Detection of the scattered light at the illumination wavelength on a charge-coupled device array detector enables 3D localization of brownian part…
▽ More
We report experimental results on heterodyne holographic microscopy of subwavelength-sized gold particles. The apparatus uses continuous green laser illumination of the metal beads in a total internal reflection configuration for dark-field operation. Detection of the scattered light at the illumination wavelength on a charge-coupled device array detector enables 3D localization of brownian particles in water
△ Less
Submitted 21 February, 2008; v1 submitted 10 December, 2007;
originally announced December 2007.
-
Temperature measurement of sub-micrometric ICs by scanning thermal microscopy
Authors:
S. Gomès,
Po Chapuis,
F. Nepveu,
N. Trannoy,
S. Volz,
B. Charlot,
Gilles Tessier,
S. Dilhaire,
Bernard Cretin,
Pascal Vairac
Abstract:
Surface temperature measurements were performed with a Scanning Thermal Microscope mounted with a thermoresistive wire probe of micrometrSurface temperature measurements were performed with a Scanning Thermal Microscope mounted with a thermoresistive wire probe of micrometric size. A CMOS device was designed with arrays of resistive lines 0.35$μ$m in width. The array periods are 0.8micron and 10…
▽ More
Surface temperature measurements were performed with a Scanning Thermal Microscope mounted with a thermoresistive wire probe of micrometrSurface temperature measurements were performed with a Scanning Thermal Microscope mounted with a thermoresistive wire probe of micrometric size. A CMOS device was designed with arrays of resistive lines 0.35$μ$m in width. The array periods are 0.8micron and 10micron to study the spatial resolution of the SThM. Integrated Circuits with passivation layers of micrometric and nanometric thicknesses were tested. To enhance signal-to-noise ratio, the resistive lines were heated with an AC current. The passivation layer of nanometric thickness allows us to distinguish the lines when the array period is 10micron. The results raise the difficulties of the SThM measurement due to the design and the topography of ICs on one hand and the size of the thermal probe on the other hand.ic size. A CMOS device was designed with arrays of resistive lines 0.35$μ$m in width. The array periods are 0.8micron and 10micron to study the spatial resolution of the SThM. Integrated Circuits with passivation layers of micrometric and nanometric thicknesses were tested. To enhance signal-to-noise ratio, the resistive lines were heated with an AC current. The passivation layer of nanometric thickness allows us to distinguish the lines when the array period is 10micron. The results raise the difficulties of the SThM measurement due to the design and the topography of ICs on one hand and the size of the thermal probe on the other hand.
△ Less
Submitted 28 November, 2007;
originally announced November 2007.