-
Extending SAXS instrument ranges through addition of a portable, inexpensive USAXS module
Authors:
Brian R. Pauw,
Andrew J. Smith,
Tim Snow,
Olga Shebanova,
John P. Sutter,
Jan Ilavsky,
Daniel Hermida-Merino,
Glen J. Smales,
Nicholas J. Terrill,
Andreas F. Thünemann,
Wim Bras
Abstract:
Ultra-SAXS can enhance the capabilities of existing SAXS/WAXS beamlines and laboratory instruments. A compact Ultra-SAXS module has been developed, which extends the measurable $q$-range with $0.0015 \leq q\mathrm{(nm^{-1})} \leq 0.2$, allowing structural dimensions between $30 \leq D$(nm)$ \leq 4000$ to be probed in addition to the range covered by a high-end SAXS/WAXS instrument. By shifting the…
▽ More
Ultra-SAXS can enhance the capabilities of existing SAXS/WAXS beamlines and laboratory instruments. A compact Ultra-SAXS module has been developed, which extends the measurable $q$-range with $0.0015 \leq q\mathrm{(nm^{-1})} \leq 0.2$, allowing structural dimensions between $30 \leq D$(nm)$ \leq 4000$ to be probed in addition to the range covered by a high-end SAXS/WAXS instrument. By shifting the module components in and out on their respective motor stages, SAXS/WAXS measurements can be easily and rapidly interleaved with USAXS measurements.
In this paper, the design considerations, realization and synchrotron findings are presented. Measurements of silica spheres, an alumina membrane, and a porous carbon catalyst are provided as application examples.
△ Less
Submitted 29 March, 2019;
originally announced April 2019.
-
I22: SAXS/WAXS beamline at Diamond Light Source -- an overview of 10 years operation
Authors:
A. J. Smith,
S. G. Alcock,
L. S. Davidson,
J. H. Emmins,
J. C. Hiller Bardsley,
P. Holloway,
M. Malfois,
A. R. Marshall,
C. L. Pizzey,
S. E. Rogers,
O. Shebanova,
T. Snow,
J. P. Sutter,
E. P. Williams,
N. J. Terrill
Abstract:
Beamline I22 at Diamond Light Source is dedicated to the study of soft matter systems from both biological and materials science. The beamline can operate in the range 3.7 keV to 22 keV for transmission SAXS and 14 keV to 20 keV for microfocus SAXS with beamsizes 240 x 60 μm$^{2}$ spot [Full width half maximum (FWHM) Horizontal (H) x Vertical (V)] at sample for the main beamline, and approximately…
▽ More
Beamline I22 at Diamond Light Source is dedicated to the study of soft matter systems from both biological and materials science. The beamline can operate in the range 3.7 keV to 22 keV for transmission SAXS and 14 keV to 20 keV for microfocus SAXS with beamsizes 240 x 60 μm$^{2}$ spot [Full width half maximum (FWHM) Horizontal (H) x Vertical (V)] at sample for the main beamline, and approximately 10 x 10 μm$^{2}$ for the dedicated microfocussing platform. There is a versatile sample platform for accommodating a range of facility, and user developed, sample environments. The high brilliance of the insertion device source on I22 allows structural investigation of materials under extreme environments (for example fluid flow at high pressures and temperatures). I22 provides reliable access to millisecond timescales, essential to understanding kinetic processes such as early folding events in proteins or structural evolution in polymers and colloids.
△ Less
Submitted 2 September, 2020; v1 submitted 13 March, 2019;
originally announced March 2019.
-
The modular SAXS data correction sequence for solids and dispersions
Authors:
Brian R. Pauw,
Andrew J. Smith,
Tim Snow,
Nick J. Terrill,
Andreas F. Thünemann
Abstract:
Data correction is probably the least favourite activity amongst users experimenting with small-angle X-ray scattering (SAXS): if it is not done sufficiently well, this may become evident during the data analysis stage, necessitating the repetition of the data corrections from scratch. A recommended, comprehensive sequence of elementary data correction steps is presented here to alleviate the diff…
▽ More
Data correction is probably the least favourite activity amongst users experimenting with small-angle X-ray scattering (SAXS): if it is not done sufficiently well, this may become evident during the data analysis stage, necessitating the repetition of the data corrections from scratch. A recommended, comprehensive sequence of elementary data correction steps is presented here to alleviate the difficulties associated with data correction. When applied in the proposed order, the resulting data will provide a high degree of accuracy for both solid samples and dispersions. The solution here can be applied without modification to any pinhole-collimated instruments with photon-counting, direct detection area detectors.
△ Less
Submitted 21 June, 2017;
originally announced June 2017.
-
Spinodal-assisted crystallization in polymer melts
Authors:
Peter D. Olmsted,
Wilson C. K. Poon,
T. C. B. McLeish,
N. J. Terrill,
A. J. Ryan
Abstract:
Recent experiments in some polymer melts quenched below the melting temperature have reported spinodal kinetics in small-angle X ray scattering before the emergence of crystalline structure. To explain these observations we propose that the coupling between density and chain conformation induces a liquid-liquid binodal within the equilibrium liquid--crystalline solid coexistence region. A simple…
▽ More
Recent experiments in some polymer melts quenched below the melting temperature have reported spinodal kinetics in small-angle X ray scattering before the emergence of crystalline structure. To explain these observations we propose that the coupling between density and chain conformation induces a liquid-liquid binodal within the equilibrium liquid--crystalline solid coexistence region. A simple phenomenological theory is developed to illustrate this idea, and several experimentally testable consequences are discussed. Shear is shown to enhance the kinetic role of the hidden binodal.
△ Less
Submitted 2 June, 1998;
originally announced June 1998.