-
A Neural Network approach to reconstructing SuperKEKB beam parameters from beamstrahlung
Authors:
S. Di Carlo,
G. Bonvicini,
N. A. Althubiti,
R. Ayad,
E. De La Cruz-Burelo,
I. Domínguez,
B. O. El Bashir,
H. Farhat,
J. Flanagan,
R. Gillard,
S. Izaguirre Gamez,
K. Kanazawa,
K. Kumara,
D. Liventsev,
P. L. M. Podesta-Lerma,
D. Ricalde-Herrmann,
D. Rodriguez Perez,
G. Tejeda-Muñoz,
M. Tobiyama I. Heredia de la Cruz
Abstract:
This work shows how it is possible to reconstruct SuperKEKB's beam parameters using a Neural Network with beamstrahlung signal from the Large Angle Beamstrahlung Monitor (LABM) as input. We describe the device, the model, and discuss the results.
This work shows how it is possible to reconstruct SuperKEKB's beam parameters using a Neural Network with beamstrahlung signal from the Large Angle Beamstrahlung Monitor (LABM) as input. We describe the device, the model, and discuss the results.
△ Less
Submitted 10 September, 2022; v1 submitted 23 June, 2022;
originally announced June 2022.
-
Status and initial physics performance studies of the MPD experiment at NICA
Authors:
MPD Collaboration,
V. Abgaryan,
R. Acevedo Kado,
S. V. Afanasyev,
G. N. Agakishiev,
E. Alpatov,
G. Altsybeev,
M. Alvarado Hernández,
S. V. Andreeva,
T. V. Andreeva,
E. V. Andronov,
N. V. Anfimov,
A. A. Aparin,
V. I. Astakhov,
E. Atkin,
T. Aushev,
G. S. Averichev,
A. V. Averyanov,
A. Ayala,
V. A. Babkin,
T. Babutsidze,
I. A. Balashov,
A. Bancer,
M. Yu. Barabanov,
D. A. Baranov
, et al. (454 additional authors not shown)
Abstract:
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document pro…
▽ More
The Nuclotron-base Ion Collider fAcility (NICA) is under construction at the Joint Institute for Nuclear Research (JINR), with commissioning of the facility expected in late 2022. The Multi-Purpose Detector (MPD) has been designed to operate at NICA and its components are currently in production. The detector is expected to be ready for data taking with the first beams from NICA. This document provides an overview of the landscape of the investigation of the QCD phase diagram in the region of maximum baryonic density, where NICA and MPD will be able to provide significant and unique input. It also provides a detailed description of the MPD set-up, including its various subsystems as well as its support and computing infrastructures. Selected performance studies for particular physics measurements at MPD are presented and discussed in the context of existing data and theoretical expectations.
△ Less
Submitted 16 February, 2022;
originally announced February 2022.
-
Performance of BeBe, a proposed dedicated beam-beam monitoring detector for the MPD-NICA experiment at JINR
Authors:
Marco Alberto Ayala Torres,
Lucina Gabriela Espinoza Beltrán,
Marcos Aurelio Fontaine Sánchez,
Luis A. Hernández-Cruz,
Luis Manuel Montaño,
Braian Adair Maldonado Luna,
Eduardo Moreno-Barbosa,
Lucio Fidel Rebolledo Herrera,
Mario Rodríguez-Cahuantzi,
Valeria Z. Reyna-Ortiz,
Guillermo Tejeda-Muñoz,
C. H. Zepeda Fernández
Abstract:
The Multipurpose Detector (MPD) is an experimental array, currently under construction, designed to study the nuclear matter created during the collisions that will be provided by the Nuclotron-based Ion Collider fAcility (NICA) at JINR. The MPD-NICA experiment consists of a typical array of particle detectors as those used to study heavy-ion collisions at LHC and RHIC. To increase the trigger cap…
▽ More
The Multipurpose Detector (MPD) is an experimental array, currently under construction, designed to study the nuclear matter created during the collisions that will be provided by the Nuclotron-based Ion Collider fAcility (NICA) at JINR. The MPD-NICA experiment consists of a typical array of particle detectors as those used to study heavy-ion collisions at LHC and RHIC. To increase the trigger capabilities of MPD for stage 2 of NICA operation, a detector conformed by two arrays of 80 plastic scintillator cells each located symmetrically at opposite sides of the interaction point of MPD is proposed (BeBe). Based on Monte Carlo simulations, a discussion of the potential physics performance of BeBe detector is given for triggering tasks and for the resolution in the determination of the event plane reaction and the centrality of the collisions at NICA. Also, laboratory measurements to estimate the time resolution of individual BeBe cells prototypes are presented. It is shown that a time resolution between 0.65 and 1.48 ns can be reached depending on the number of photosensors employed to collect the scintillation photons. The BeBe detector will be complementary to FFD and FHCAL forward detectors.
△ Less
Submitted 24 August, 2022; v1 submitted 6 October, 2021;
originally announced October 2021.
-
The conceptual design of the miniBeBe detector proposed for NICA-MPD
Authors:
Ramón Acevedo Kado,
Mauricio Alvarado Hernández,
Alejandro Ayala,
Marco Alberto Ayala Torres,
Wolfgang Bietenholz,
Dario Chaires,
Eleazar Cuautle,
Isabel Domínguez,
Alejandro Guirado,
Ivonne Maldonado,
Julio Maldonado,
Eduardo Moreno-Barbosa,
P. A. Nieto-Marín,
Miguel Enrique Patiño Salazar,
Lucio Rebolledo,
Mario Rodríguez-Cahuantzi,
D. Rodríguez-Figueroa,
Valeria Z. Reyna-Ortiz,
Guillermo Tejeda-Muñoz,
María Elena Tejeda-Yeomans,
Luis Valenzuela-Cázares,
C. H. Zepeda Fernández
Abstract:
We present the conceptual design for the miniBeBe detector proposed to be installed as a level-0 trigger for the TOF of the NICA-MPD. We discuss the design and the geometrical array of its sensitive parts, the read-out electronics as well as the mechanical support that is envisioned. We also present simulation results for p + p and Bi + Bi collisions to study its capabilities as a function of mult…
▽ More
We present the conceptual design for the miniBeBe detector proposed to be installed as a level-0 trigger for the TOF of the NICA-MPD. We discuss the design and the geometrical array of its sensitive parts, the read-out electronics as well as the mechanical support that is envisioned. We also present simulation results for p + p and Bi + Bi collisions to study its capabilities as a function of multiplicity both as a level-0 trigger for the TOF, as well as to serve as a beam-gas interaction veto and to locate the beam-beam interaction vertex.
△ Less
Submitted 24 November, 2020; v1 submitted 23 July, 2020;
originally announced July 2020.
-
A beam-beam monitoring detector for the MPD experiment at NICA
Authors:
Mauricio Alvarado,
Alejandro Ayala,
Marco Alberto Ayala-Torres,
Wolfgang Bietenholz,
Isabel Dominguez,
Marcos Fontaine,
P. González-Zamora,
Luis Manuel Montaño,
E. Moreno-Barbosa,
Miguel Enrique Patiño Salazar,
L. A. P. Moreno,
P. A. Nieto-Marín,
V. Z. Reyna Ortiz,
M. Rodríguez-Cahuantzi,
G. Tejeda-Muñoz,
Maria Elena Tejeda-Yeomans,
A. Villatoro-Tello,
C. H. Zepeda Fernández
Abstract:
The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. These studies, while providing insight into the physics of heavy-ion collisions, are relevant for improving our understanding of the evol…
▽ More
The Multi-Purpose Detector (MPD) is to be installed at the Nuclotron Ion Collider fAcility (NICA) of the Joint Institute for Nuclear Research (JINR). Its main goal is to study the phase diagram of the strongly interacting matter produced in heavy-ion collisions. These studies, while providing insight into the physics of heavy-ion collisions, are relevant for improving our understanding of the evolution of the early Universe and the formation of neutron stars. In order to extend the MPD trigger capabilities, we propose to include a high granularity beam-beam monitoring detector (BE-BE) to provide a level-0 trigger signal with an expected time resolution of 30 ps. This new detector will improve the determination of the reaction plane by the MPD experiment, a key measurement for flow studies that provides physics insight into the early stages of the reaction. In this work, we use simulated Au+Au collisions at NICA energies to show the potential of such a detector to determine the event plane resolution, providing further redundancy to the detectors originally considered for this purpose namely, the Fast Forward Detector (FFD) and the Hadron Calorimeter (HCAL). We also show our results for the time resolution studies of two prototype cells carried out at the T10 beam line at the CERN PS complex.
△ Less
Submitted 4 December, 2019; v1 submitted 25 September, 2018;
originally announced September 2018.
-
Phase I results with the Large Angle Beamstrahlung Monitor (LABM) with SuperKEKB beams
Authors:
R. Ayad,
G. Bonvicini,
S. Di Carlo,
E. De La Cruz-Burelo,
H. Farhat,
J. Flanagan,
S. Gamez Izaguirre,
R. Gillard,
M. E. Fernandez Villanueva,
H. Ikeda,
K. Kanazawa,
B. O. ElBashir,
P. Podesta,
D. Rodriguez-Perez,
G. Tejeda-Munoz
Abstract:
We report on the SuperKEKB Phase I operations of the Large Angle Beamstrhalung Monitor (LABM). The detector is described and its performance characterized using the synchrotron radiation backgrounds from the last Beam Line magnets. The backgrounds are also used to determine the expected position of the Interaction Point (IP), and the expected background rates during Phase II.
We report on the SuperKEKB Phase I operations of the Large Angle Beamstrhalung Monitor (LABM). The detector is described and its performance characterized using the synchrotron radiation backgrounds from the last Beam Line magnets. The backgrounds are also used to determine the expected position of the Interaction Point (IP), and the expected background rates during Phase II.
△ Less
Submitted 12 October, 2017; v1 submitted 5 September, 2017;
originally announced September 2017.