-
Twisted Pair Transmission Line Coil -- A Flexible, Self-Decoupled and Extremely Robust Element for 7T MRI
Authors:
Jules Vliem,
Ying Xiao,
Daniel Wenz,
Li**g Xin,
Wouter Teeuwisse,
Thomas Ruytenberg,
Andrew Webb,
Irena Zivkovic
Abstract:
This study evaluates the performance of a twisted pair transmission line coil as a transceive element for 7T MRI in terms of physical flexibility, robustness to shape deformations, and interelement decoupling. Each coil element was created by sha** a twisted pair of wires into a circle. One wire was interrupted at the top, while the other was interrupted at the bottom, and connected to the match…
▽ More
This study evaluates the performance of a twisted pair transmission line coil as a transceive element for 7T MRI in terms of physical flexibility, robustness to shape deformations, and interelement decoupling. Each coil element was created by sha** a twisted pair of wires into a circle. One wire was interrupted at the top, while the other was interrupted at the bottom, and connected to the matching circuit. Electromagnetic simulations were conducted to determine the optimal number of twists per length (in terms of B$_1^+$ field efficiency, SAR efficiency, sensitivity to elongation and interelement decoupling properties) and for investigating the fundamental operational principle of the coil through fields streamline visualization. A comparison between the twisted pair coil and a conventional loop coil in terms of B$_1^+$ fields, maxSAR10g, and stability of $S_{11}$ when the coil was deformed, was performed. Experimentally measured interelement coupling between individual elements of multichannel arrays was also investigated. Increasing the number of twists per length resulted in a more physically robust coil. Poynting vector streamline visualization showed that the twisted pair coil concentrated most of the energy in the near field. The twisted pair coil exhibited comparable B$_1^+$ fields and improved maxSAR10g to the conventional coil but demonstrated exceptional stability with respect to coil deformation and a strong self-decoupling nature when placed in an array configuration. The findings highlight the robustness of the twisted pair coil, showcasing its stability under shape variations. This coil holds great potential as a flexible RF coil for various imaging applications using multiple-element arrays, benefiting from its inherent decoupling.
△ Less
Submitted 24 October, 2023; v1 submitted 15 June, 2023;
originally announced June 2023.
-
ASL to PET Translation by a Semi-supervised Residual-based Attention-guided Convolutional Neural Network
Authors:
Sahar Yousefi,
Hessam Sokooti,
Wouter M. Teeuwisse,
Dennis F. R. Heijtel,
Aart J. Nederveen,
Marius Staring,
Matthias J. P. van Osch
Abstract:
Positron Emission Tomography (PET) is an imaging method that can assess physiological function rather than structural disturbances by measuring cerebral perfusion or glucose consumption. However, this imaging technique relies on injection of radioactive tracers and is expensive. On the contrary, Arterial Spin Labeling (ASL) MRI is a non-invasive, non-radioactive, and relatively cheap imaging techn…
▽ More
Positron Emission Tomography (PET) is an imaging method that can assess physiological function rather than structural disturbances by measuring cerebral perfusion or glucose consumption. However, this imaging technique relies on injection of radioactive tracers and is expensive. On the contrary, Arterial Spin Labeling (ASL) MRI is a non-invasive, non-radioactive, and relatively cheap imaging technique for brain hemodynamic measurements, which allows quantification to some extent. In this paper we propose a convolutional neural network (CNN) based model for translating ASL to PET images, which could benefit patients as well as the healthcare system in terms of expenses and adverse side effects. However, acquiring a sufficient number of paired ASL-PET scans for training a CNN is prohibitive for many reasons. To tackle this problem, we present a new semi-supervised multitask CNN which is trained on both paired data, i.e. ASL and PET scans, and unpaired data, i.e. only ASL scans, which alleviates the problem of training a network on limited paired data. Moreover, we present a new residual-based-attention guided mechanism to improve the contextual features during the training process. Also, we show that incorporating T1-weighted scans as an input, due to its high resolution and availability of anatomical information, improves the results. We performed a two-stage evaluation based on quantitative image metrics by conducting a 7-fold cross validation followed by a double-blind observer study. The proposed network achieved structural similarity index measure (SSIM), mean squared error (MSE) and peak signal-to-noise ratio (PSNR) values of $0.85\pm0.08$, $0.01\pm0.01$, and $21.8\pm4.5$ respectively, for translating from 2D ASL and T1-weighted images to PET data. The proposed model is publicly available via https://github.com/yousefis/ASL2PET.
△ Less
Submitted 8 March, 2021;
originally announced March 2021.
-
In vivo three-dimensional brain and extremity MRI at 50 mT using a permanent magnet Halbach array
Authors:
T. O'Reilly,
W. M. Teeuwisse,
D. de Gans,
K. Koolstra,
A. G. Webb
Abstract:
Purpose: To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time.
Methods: A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom built gradient coils, radiofrequency coil, gradient amplifiers and radiofrequency amplifier were integrated and tested o…
▽ More
Purpose: To design a low-cost, portable permanent magnet-based MRI system capable of obtaining in vivo MR images within a reasonable scan time.
Methods: A discretized Halbach permanent magnet array with a clear bore diameter of 27 cm was designed for operation at 50 mT. Custom built gradient coils, radiofrequency coil, gradient amplifiers and radiofrequency amplifier were integrated and tested on both phantoms and in vivo.
Results: Phantom results showed that the gradient non-linearity in the y- and z-directions was less than 5% over a 15 cm field-of-view and did not need correcting. For the x-direction, it was significantly greater, but could be partially corrected in post-processing. Three dimensional In vivo scans of the brain of a healthy volunteer using a turbo-spin echo sequence were acquired at a spatial resolution of 4x4x4 mm in a time of ~2 mins. T1-weighted and T2-weighted scans showed a good degree of tissue contrast. In addition, in vivo scans of the knee of a healthy volunteer were acquired at a spatial resolution of ~3x2x2 mm within a twelve minutes to show the applicability of the system to extremity imaging.
Conclusion: This work has shown that it is possible to construct a low-field MRI unit with hardware components costing less than 10000 euros, which is able to acquire human images in vivo within a reasonable data acquisition time. The system has a high degree of portability with magnet weight ~75 kg, gradient and RF amplifiers each 15 kg, gradient coils 10 kg and spectrometer 5 kg.
△ Less
Submitted 6 May, 2020;
originally announced May 2020.