-
Electromagnetically induced transparency based Rydberg-atom sensor for quantum voltage measurements
Authors:
Christopher L. Holloway,
Nikunjkumar Prajapati,
John Kitching,
Jeffery A. Sherman,
Carson Teale,
Alain Rufenacht,
Alexandra B. Artusio-Glimpse,
Matthew T. Simons,
Amy K. Robinson,
Eric B. Norrgard
Abstract:
We investigate the Stark shift in Rydberg rubidium atoms through electromagnetically induced transparency for the measurement of direct current (dc) and 60~Hz alternating current (ac) voltages. This technique has direct applications to atom-based measurements of dc and ac voltage and the calibration of voltage instrumentation. We present experimental results for different atomic states that allow…
▽ More
We investigate the Stark shift in Rydberg rubidium atoms through electromagnetically induced transparency for the measurement of direct current (dc) and 60~Hz alternating current (ac) voltages. This technique has direct applications to atom-based measurements of dc and ac voltage and the calibration of voltage instrumentation. We present experimental results for different atomic states that allow for dc and ac voltage measurements ranging from 0~V to 12~V. A Rydberg atom-based voltage standard could become an alternative calibration method with more favorable size, weight, power consumption, and cost compared to the more precise Josephson voltage standard. In this study, we also demonstrate how the voltage measurements can be utilized to determine the atomic polarizability for the Rydberg states. The Rydberg atom-based voltage measurement technology would become a complimentary method for dissemination of the voltage scale directly to the end user.
△ Less
Submitted 22 October, 2021; v1 submitted 5 October, 2021;
originally announced October 2021.
-
Robust High-Dynamic-Range Vector Magnetometry via Nitrogen-Vacancy Centers in Diamond
Authors:
Hannah Clevenson,
Linh M. Pham,
Carson Teale,
Kerry Johnson,
Dirk Englund,
Danielle Braje
Abstract:
We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynami…
▽ More
We demonstrate a robust, scale-factor-free vector magnetometer, which uses a closed-loop frequency-locking scheme to simultaneously track Zeeman-split resonance pairs of nitrogen-vacancy (NV) centers in diamond. Compared with open-loop methodologies, this technique is robust against fluctuations in temperature, resonance linewidth, and contrast; offers a three-order-of-magnitude increase in dynamic range; and allows for simultaneous interrogation of multiple transition frequencies. By directly detecting the resonance frequencies of NV centers aligned along each of the diamond's four tetrahedral crystallographic axes, we perform full vector reconstruction of an applied magnetic field.
△ Less
Submitted 26 February, 2018;
originally announced February 2018.
-
Broadband Magnetometry and Temperature Sensing with a Light Trap** Diamond Waveguide
Authors:
Hannah Clevenson,
Matthew E. Trusheim,
Tim Schroder,
Carson Teale,
Danielle Braje,
Dirk Englund
Abstract:
Solid-state quantum sensors are attracting wide interest because of their exceptional sensitivity at room temperature. In particular, the spin properties of individual nitrogen vacancy (NV) color centers in diamond make it an outstanding nanoscale sensor of magnetic fields, electric fields, and temperature, under ambient conditions. Recent work on ensemble NV-based magnetometers, inertial sensors,…
▽ More
Solid-state quantum sensors are attracting wide interest because of their exceptional sensitivity at room temperature. In particular, the spin properties of individual nitrogen vacancy (NV) color centers in diamond make it an outstanding nanoscale sensor of magnetic fields, electric fields, and temperature, under ambient conditions. Recent work on ensemble NV-based magnetometers, inertial sensors, and clocks have employed $N$ unentangled color centers to realize a factor of up to $\sqrt{N}$ improvement in sensitivity. However, to realize fully this signal enhancement, new techniques are required to excite efficiently and to collect fluorescence from large NV ensembles. Here, we introduce a light-trap** diamond waveguide (LTDW) geometry that enables both high fluorescence collection ($\sim20\%$) and efficient pump absorption achieving an effective path length exceeding $1$ meter in a millimeter-sized device. The LTDW enables in excess of $2\%$ conversion efficiency of pump photons into optically detected magnetic resonance (ODMR) fluorescence, a \textit{three orders of magnitude} improvement over previous single-pass geometries. This dramatic enhancement of ODMR signal enables broadband measurements of magnetic field and temperature at less than $1$ Hz, a frequency range inaccessible by dynamical decoupling techniques. We demonstrate $\sim 1~\mbox{nT}/\sqrt{\mbox{Hz}}$ magnetic field sensitivity for $0.1$ Hz to $10$ Hz and a thermal sensitivity of $\sim 400 ~μ\mbox{K}/\sqrt{\mbox{Hz}}$ and estimate a spin projection limit at $\sim 0.36$ fT/$\sqrt{\mbox{Hz}}$ and $\sim 139~\mbox{pK}/\sqrt{\mbox{Hz}}$, respectively.
△ Less
Submitted 19 June, 2014;
originally announced June 2014.