-
Using graph neural networks to reconstruct charged pion showers in the CMS High Granularity Calorimeter
Authors:
M. Aamir,
B. Acar,
G. Adamov,
T. Adams,
C. Adloff,
S. Afanasiev,
C. Agrawal,
C. Agrawal,
A. Ahmad,
H. A. Ahmed,
S. Akbar,
N. Akchurin,
B. Akgul,
B. Akgun,
R. O. Akpinar,
E. Aktas,
A. AlKadhim,
V. Alexakhin,
J. Alimena,
J. Alison,
A. Alpana,
W. Alshehri,
P. Alvarez Dominguez,
M. Alyari,
C. Amendola
, et al. (550 additional authors not shown)
Abstract:
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadr…
▽ More
A novel method to reconstruct the energy of hadronic showers in the CMS High Granularity Calorimeter (HGCAL) is presented. The HGCAL is a sampling calorimeter with very fine transverse and longitudinal granularity. The active media are silicon sensors and scintillator tiles readout by SiPMs and the absorbers are a combination of lead and Cu/CuW in the electromagnetic section, and steel in the hadronic section. The shower reconstruction method is based on graph neural networks and it makes use of a dynamic reduction network architecture. It is shown that the algorithm is able to capture and mitigate the main effects that normally hinder the reconstruction of hadronic showers using classical reconstruction methods, by compensating for fluctuations in the multiplicity, energy, and spatial distributions of the shower's constituents. The performance of the algorithm is evaluated using test beam data collected in 2018 prototype of the CMS HGCAL accompanied by a section of the CALICE AHCAL prototype. The capability of the method to mitigate the impact of energy leakage from the calorimeter is also demonstrated.
△ Less
Submitted 30 June, 2024; v1 submitted 17 June, 2024;
originally announced June 2024.
-
First Results from a Broadband Search for Dark Photon Dark Matter in the $44$ to $52\,μ$eV range with a coaxial dish antenna
Authors:
Stefan Knirck,
Gabe Hoshino,
Mohamed H. Awida,
Gustavo I. Cancelo,
Martin Di Federico,
Benjamin Knepper,
Alex Lapuente,
Mira Littmann,
David W. Miller,
Donald V. Mitchell,
Derrick Rodriguez,
Mark K. Ruschman,
Matthew A. Sawtell,
Leandro Stefanazzi,
Andrew Sonnenschein,
Gary W. Teafoe,
Daniel Bowring,
G. Carosi,
Aaron Chou,
Clarence L. Chang,
Kristin Dona,
Rakshya Khatiwada,
Noah A. Kurinsky,
Jesse Liu,
Cristián Pena
, et al. (3 additional authors not shown)
Abstract:
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are re…
▽ More
We present first results from a dark photon dark matter search in the mass range from 44 to 52 $μ{\rm eV}$ ($10.7 - 12.5\,{\rm GHz}$) using a room-temperature dish antenna setup called GigaBREAD. Dark photon dark matter converts to ordinary photons on a cylindrical metallic emission surface with area $0.5\,{\rm m}^2$ and is focused by a novel parabolic reflector onto a horn antenna. Signals are read out with a low-noise receiver system. A first data taking run with 24 days of data does not show evidence for dark photon dark matter in this mass range, excluding dark photon - photon mixing parameters $χ\gtrsim 10^{-12}$ in this range at 90% confidence level. This surpasses existing constraints by about two orders of magnitude and is the most stringent bound on dark photons in this range below 49 $μ$eV.
△ Less
Submitted 3 May, 2024; v1 submitted 20 October, 2023;
originally announced October 2023.
-
The CMS Magnetic Field Measuring and Monitoring Systems
Authors:
Vyacheslav Klyukhin,
Austin Ball,
Felix Bergsma,
Henk Boterenbrood,
Benoit Curé,
Domenico Dattola,
Andrea Gaddi,
Hubert Gerwig,
Alain Hervé,
Richard Loveless,
Gary Teafoe,
Daniel Wenman,
Wolfram Zeuner,
Jerry Zimmerman
Abstract:
This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured…
▽ More
This review article describes the performance of the magnetic field measuring and monitoring systems for the Compact Muon Solenoid (CMS) detector. To cross-check the magnetic flux distribution obtained with the CMS magnet model, four systems for measuring the magnetic flux density in the detector volume were used. The magnetic induction inside the 6 m diameter superconducting solenoid was measured and is currently monitored by four nuclear magnetic resonance (NMR) probes installed using special tubes outside the barrel hadron calorimeter. Two more NRM probes were installed at the faces of the tracking system. The field inside the superconducting solenoid was precisely measured in 2006 in a cylindrical volume of 3.448 m in diameter and 7 m in length using 10 three-dimensional (3D) B-sensors based on the Hall effect. These B-sensors were installed on each of the two propeller arms of an automated field-map** machine. In addition to these measurement systems, a system for monitoring the magnetic field during the CMS detector operation has been developed. Inside the solenoid in the horizontal plane, 4 3D B-sensors were installed at the faces of the tracking detector. Twelve 3D B-sensors were installed on the surfaces of the flux-return yoke nose disks. Seventy 3D B-sensors were installed in the air gaps of the CMS magnet yoke. A specially developed flux loop technique was used for the most complex measurements of the magnetic flux density inside the steel blocks of the CMS magnet yoke. The flux loops are installed in 22 sections of the flux-return yoke blocks. The areas enclosed by these coils varied from 0.3 to 1.59 m$^{2}$ in the blocks of the barrel wheels and from 0.5 to 1.12 m$^{2}$ in the blocks of the yoke endcap disks. The development of these systems and the results of the magnetic flux density measurements across the CMS magnet are presented and discussed in this review article.
△ Less
Submitted 5 February, 2022;
originally announced February 2022.
-
Measurement of the CMS Magnetic Field
Authors:
V. I. Klyukhin,
A. Ball,
F. Bergsma,
D. Campi,
B. Curé,
A. Gaddi,
H. Gerwig,
A. Hervé,
J. Korienek,
F. Linde,
C. Lindenmeyer,
R. Loveless,
M. Mulders,
T. Nebel,
R. P. Smith,
D. Stickland,
G. Teafoe,
L. Veillet,
J. K. Zimmerman
Abstract:
The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurement…
▽ More
The measurement of the magnetic field in the tracking volume inside the superconducting coil of the Compact Muon Solenoid (CMS) detector under construction at CERN is done with a fieldmapper designed and produced at Fermilab. The fieldmapper uses 10 3-D B-sensors (Hall probes) developed at NIKHEF and calibrated at CERN to precision 0.05% for a nominal 4 T field. The precise fieldmapper measurements are done in 33840 points inside a cylinder of 1.724 m radius and 7 m long at central fields of 2, 3, 3.5, 3.8, and 4 T. Three components of the magnetic flux density at the CMS coil maximum excitation and the remanent fields on the steel-air interface after discharge of the coil are measured in check-points with 95 3-D B-sensors located near the magnetic flux return yoke elements. Voltages induced in 22 flux-loops made of 405-turn installed on selected segments of the yoke are sampled online during the entire fast discharge (190 s time-constant) of the CMS coil and integrated offline to provide a measurement of the initial magnetic flux density in steel at the maximum field to an accuracy of a few percent. The results of the measurements made at 4 T are reported and compared with a three-dimensional model of the CMS magnet system calculated with TOSCA.
△ Less
Submitted 3 October, 2011;
originally announced October 2011.