-
The POLARBEAR-2 and Simons Array Focal Plane Fabrication Status
Authors:
B. Westbrook,
P. A. R. Ade,
M. Aguilar,
Y. Akiba,
K. Arnold,
C. Baccigalupi,
D. Barron,
D. Beck,
S. Beckman,
A. N. Bender,
F. Bianchini,
D. Boettger,
J. Borrill,
S. Chapman,
Y. Chinone,
G. Coppi,
K. Crowley,
A. Cukierman,
T. de,
R. Dünner,
M. Dobbs,
T. Elleflot,
J. Errard,
G. Fabbian,
S. M. Feeney
, et al. (68 additional authors not shown)
Abstract:
We present on the status of POLARBEAR-2 A (PB2-A) focal plane fabrication. The PB2-A is the first of three telescopes in the Simon Array (SA), which is an array of three cosmic microwave background (CMB) polarization sensitive telescopes located at the POLARBEAR (PB) site in Northern Chile. As the successor to the PB experiment, each telescope and receiver combination is named as PB2-A, PB2-B, and…
▽ More
We present on the status of POLARBEAR-2 A (PB2-A) focal plane fabrication. The PB2-A is the first of three telescopes in the Simon Array (SA), which is an array of three cosmic microwave background (CMB) polarization sensitive telescopes located at the POLARBEAR (PB) site in Northern Chile. As the successor to the PB experiment, each telescope and receiver combination is named as PB2-A, PB2-B, and PB2-C. PB2-A and -B will have nearly identical receivers operating at 90 and 150 GHz while PB2-C will house a receiver operating at 220 and 270 GHz. Each receiver contains a focal plane consisting of seven close-hex packed lenslet coupled sinuous antenna transition edge sensor bolometer arrays. Each array contains 271 di-chroic optical pixels each of which have four TES bolometers for a total of 7588 detectors per receiver. We have produced a set of two types of candidate arrays for PB2-A. The first we call Version 11 (V11) and uses a silicon oxide (SiOx) for the transmission lines and cross-over process for orthogonal polarizations. The second we call Version 13 (V13) and uses silicon nitride (SiNx) for the transmission lines and cross-under process for orthogonal polarizations. We have produced enough of each type of array to fully populate the focal plane of the PB2-A receiver. The average wirebond yield for V11 and V13 arrays is 93.2% and 95.6% respectively. The V11 arrays had a superconducting transition temperature (Tc) of 452 +/- 15 mK, a normal resistance (Rn) of 1.25 +/- 0.20 Ohms, and saturations powers of 5.2 +/- 1.0 pW and 13 +/- 1.2 pW for the 90 and 150 GHz bands respectively. The V13 arrays had a superconducting transition temperature (Tc) of 456 +/-6 mK, a normal resistance (Rn) of 1.1 +/- 0.2 Ohms, and saturations powers of 10.8 +/- 1.8 pW and 22.9 +/- 2.6 pW for the 90 and 150 GHz bands respectively.
△ Less
Submitted 8 October, 2022;
originally announced October 2022.
-
Quantum Control of Two Critically Dressed Spin 1/2 Species in Magnetic Fluctuations
Authors:
Raymond Tat,
Christopher Swank
Abstract:
The neutron electric dipole moment experiment at the Spallation Neutron Source (nEDM@SNS experiment) proposes to measure the nEDM using the spin-dependent capture cross section of neutrons on $^3$He. The critical dressing mode of this experiment uses an oscillating magnetic field to dress the gyromagnetic ratios of neutrons and $^3$He to the same value. While this technique grants increased sensit…
▽ More
The neutron electric dipole moment experiment at the Spallation Neutron Source (nEDM@SNS experiment) proposes to measure the nEDM using the spin-dependent capture cross section of neutrons on $^3$He. The critical dressing mode of this experiment uses an oscillating magnetic field to dress the gyromagnetic ratios of neutrons and $^3$He to the same value. While this technique grants increased sensitivity to the nEDM by improving the signal-to-noise ratio, this mode of measurement also introduces additional noise from the power supply used to drive the dressing field. This can lead to randomly fluctuating magnetic fields which cause the spins of neutrons and $^3$He to drift apart over time. Here we use second-order time-dependent perturbation theory to compute relaxation and frequency shifts due to fluctuations in the dressing field in terms of the magnetic field noise power spectrum and compare these calculations to numerical solutions obtained by integrating the Bloch equations. We then use these results to develop mitigation strategies for this type of noise. Furthermore, we report on spin dressing modulation techniques that significantly amplify coherence times for the critically dressed system, and attempt to quantify the coherence time achievable.
△ Less
Submitted 3 December, 2021;
originally announced December 2021.
-
A cryogenic continuously rotating half-wave plate for the POLARBEAR-2b cosmic microwave background receiver
Authors:
C. A. Hill,
A. Kusaka,
P. Ashton,
P. Barton,
T. Adkins,
K. Arnold,
B. Bixler,
S. Ganjam,
A. T. Lee,
F. Matsuda,
T. Matsumura,
Y. Sakurai,
R. Tat,
Y. Zhou
Abstract:
We present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background (CMB) receiver, the second installment of the Simons Array. PB-2b will observe at 5,200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 and 150 GHz. In order to suppress atmospheric 1/f noise and mitiga…
▽ More
We present the design and laboratory evaluation of a cryogenic continuously rotating half-wave plate (CHWP) for the POLARBEAR-2b (PB-2b) cosmic microwave background (CMB) receiver, the second installment of the Simons Array. PB-2b will observe at 5,200 m elevation in the Atacama Desert of Chile in two frequency bands centered at 90 and 150 GHz. In order to suppress atmospheric 1/f noise and mitigate systematic effects that arise when differencing orthogonal detectors, PB-2b modulates linear sky polarization using a CHWP rotating at 2 Hz. The CHWP has a 440 mm clear aperture diameter and is cooled to $\approx$ 50 K in the PB-2b receiver cryostat. It consists of a low-friction superconducting magnetic bearing (SMB) and a low-torque synchronous electromagnetic motor, which together dissipate < 2 W. During cooldown, a grip-and-release mechanism centers the rotor to < 0.5 mm, and during continuous rotation, an incremental optical encoder measures the rotor angle with a noise level of 0.1 $\mathrm{μrad / \sqrt{Hz}}$. We discuss the experimental requirements for the PB-2b CHWP, the designs of its various subsystems, and the results of its evaluation in the laboratory. The presented CHWP has been deployed to Chile and is expected to see first light on PB-2b in 2020 or 2021.
△ Less
Submitted 10 September, 2020; v1 submitted 8 September, 2020;
originally announced September 2020.
-
A large-diameter cryogenic rotation stage for half-wave plate polarization modulation on the POLARBEAR-2 experiment
Authors:
Charles A. Hill,
Akito Kusaka,
Paul Barton,
Bryce Bixler,
Alex G. Droster,
Mael Flament,
Suhas Ganjam,
Arian Jadbabaie,
Oliver Jeong,
Adrian T. Lee,
Alex Madurowicz,
Fred T. Matsuda,
Tomotake Matsumura,
Adam Rutkowski,
Yuki Sakurai,
Danielle R. Sponseller,
Aritoki Suzuki,
Raymond Tat
Abstract:
We describe the design of a cryogenic rotation stage (CRS) for use with the cryogenic half-wave plate (CHWP) polarization modulator on the POLARBEAR-2b and POLARBEAR-2c (PB2b/c) cosmic microwave background (CMB) experiments, the second and third installments of the Simons Array. Rapid modulation of the CMB polarization signal using a CHWP suppresses 1/f contamination due to atmospheric turbulence…
▽ More
We describe the design of a cryogenic rotation stage (CRS) for use with the cryogenic half-wave plate (CHWP) polarization modulator on the POLARBEAR-2b and POLARBEAR-2c (PB2b/c) cosmic microwave background (CMB) experiments, the second and third installments of the Simons Array. Rapid modulation of the CMB polarization signal using a CHWP suppresses 1/f contamination due to atmospheric turbulence and allows a single polarimeter to measure both polarization states, mitigating systematic effects that arise when differencing orthogonal detectors. To modulate the full detector array while avoiding excess photon loading due to thermal emission, the CHWP must have a clear-aperture diameter of > 450 mm and be cooled to < 100 K. We have designed a 454-mm-clear-aperture, < 65 K CRS using a superconducting magnetic bearing driven by a synchronous magnetic motor. We present the specifications for the CRS, its interfacing to the PB2b/c receiver cryostat, its performance in a stand-alone test, and plans for future work.
△ Less
Submitted 25 May, 2018;
originally announced May 2018.