-
Measurement and analysis of the $^{246}$Cm and $^{248}$Cm neutron capture cross-sections at the EAR2 of the n TOF facility
Authors:
V. Alcayne,
A. Kimura,
E. Mendoza,
D. Cano-Ott,
O. Aberle,
F. Álvarez-Velarde,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
V. Bécares,
V. Babiano-Suarez,
M. Bacak,
M. Barbagallo,
F. Bečvář,
G. Bellia,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Busso,
M. Caamaño,
L. Caballero-Ontanaya,
F. Calviño,
M. Calviani,
A. Casanovas
, et al. (108 additional authors not shown)
Abstract:
The $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water react…
▽ More
The $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) cross-sections have been measured at the Experimental Area 2 (EAR2) of the n_TOF facility at CERN with three C$_6$D$_6$ detectors. This measurement is part of a collective effort to improve the capture cross-section data for Minor Actinides (MAs), which are required to estimate the production and transmutation rates of these isotopes in light water reactors and innovative reactor systems. In particular, the neutron capture in $^{246}$Cm and $^{248}$Cm open the path for the formation of other Cm isotopes and heavier elements such as Bk and Cf and the knowledge of (n,$γ$) cross-sections of these Cm isotopes plays an important role in the transport, transmutation and storage of the spent nuclear fuel. The reactions $^{246}$Cm(n,$γ$) and $^{248}$Cm(n,$γ$) have been the two first capture measurements analyzed at n_TOF EAR2. Until this experiment and two recent measurements performed at J-PARC, there was only one set of data of the capture cross-sections of $^{246}$Cm and $^{248}$Cm, that was obtained in 1969 in an underground nuclear explosion experiment. In the measurement at n_TOF a total of 13 resonances of $^{246}$Cm between 4 and 400 eV and 5 of $^{248}$Cm between 7 and 100 eV have been identified and fitted. The radiative kernels obtained for $^{246}$Cm are compatible with JENDL-5, but some of them are not with JENDL-4, which has been adopted by JEFF-3.3 and ENDF/B-VIII.0. The radiative kernels obtained for the first three $^{248}$Cm resonances are compatible with JENDL-5, however, the other two are not compatible with any other evaluation and are 20% and 60% larger than JENDL-5.
△ Less
Submitted 8 July, 2024;
originally announced July 2024.
-
Ambient neutron dosimetry in high energy and pulsed neutron fields
Authors:
Ariel Tarifeno-Saldivia,
Francisco Calvino,
Alfredo De Blas,
Benedetta Brusasco,
Adria Casanovas-Hoste,
Ana M. Cives,
Guillem Cortes,
Roger Garcia,
Francisco Molina,
Nil Mont-Geli,
Max Pallas,
Cristian Pavez
Abstract:
The status of the LINrem project is presented, focusing on the development of innovative neutron dosimeters with enhanced energy sensitivity, time resolution, and portability. Designed to meet the technical demands of radiation protection in modern particle and nuclear facilities, these dosimeters are discussed in detail. Results from experimental campaigns showcasing their efficacy in pulsed fiel…
▽ More
The status of the LINrem project is presented, focusing on the development of innovative neutron dosimeters with enhanced energy sensitivity, time resolution, and portability. Designed to meet the technical demands of radiation protection in modern particle and nuclear facilities, these dosimeters are discussed in detail. Results from experimental campaigns showcasing their efficacy in pulsed fields generated by fusion plasmas and high-intensity pulsed lasers are presented. Additionally, prospects and future plans for the LINrem project are outlined.
△ Less
Submitted 27 March, 2024;
originally announced March 2024.
-
First Exploration of Monopole-Driven Shell Evolution above the N = 126 shell closure: new Millisecond Isomers in 213Tl and 215Tl
Authors:
T. T. Yeung,
A. I. Morales,
J. Wu,
M. Liu,
C. Yuan,
S. Nishimura,
V. H. Phong,
N. Fukuda,
J. L. Tain,
T. Davinson,
K. P. Rykaczewski,
R. Yokoyama,
T. Isobe,
M. Niikura,
Zs. Podolyak,
G. Alcala,
A. Algora,
J. Agramunt,
C. Appleton,
H. Baba,
R. Caballero-Folch,
P. Calvino,
M. P. Carpenter,
I. Dillmann,
A. Estrade
, et al. (30 additional authors not shown)
Abstract:
Isomer spectroscopy of heavy neutron-rich nuclei beyond the N=126 closed shell has been performed for the first time at the Radioactive Isotope Beam Factory of the RIKEN Nishina Center. New millisecond isomers have been identified at low excitation energies, 985.3(19) keV in 213Tl and 874(5) keV in 215Tl. The measured half-lives of 1.34(5) ms in 213Tl and 3.0(3) ms in 215Tl suggest spins and parit…
▽ More
Isomer spectroscopy of heavy neutron-rich nuclei beyond the N=126 closed shell has been performed for the first time at the Radioactive Isotope Beam Factory of the RIKEN Nishina Center. New millisecond isomers have been identified at low excitation energies, 985.3(19) keV in 213Tl and 874(5) keV in 215Tl. The measured half-lives of 1.34(5) ms in 213Tl and 3.0(3) ms in 215Tl suggest spins and parities 11/2- with the single proton-hole configuration h11/2 as leading component. They are populated via E1 transitions by the decay of higher-lying isomeric states with proposed spin and parity 17/2+, interpreted as arising from a single s1/2 proton hole coupled to the 8+ seniority isomer in the (A+1)Pb cores. The lowering of the 11/2- states is ascribed to an increase of the h11/2 proton effective single-particle energy as the second g9/2 orbital is filled by neutrons, owing to a significant reduction of the proton-neutron monopole interaction between the h11/2 and g9/2 orbitals. The new ms-isomers provide the first experimental observation of shell evolution in the almost unexplored N>126 nuclear region below doubly-magic 208Pb.
△ Less
Submitted 25 April, 2024; v1 submitted 12 January, 2024;
originally announced January 2024.
-
Pushing the high count rate limits of scintillation detectors for challenging neutron-capture experiments
Authors:
J. Balibrea Correa,
J. Lerendegui-Marco,
V. Babiano-Suarez,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
A. Pérez de Rada,
J. Plaza del Olmo,
A. Sánchez-Caballero,
A. Casanovas,
F. Calviño,
S. Valenta,
O. Aberle,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes
, et al. (109 additional authors not shown)
Abstract:
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects…
▽ More
One of the critical aspects for the accurate determination of neutron capture cross sections when combining time-of-flight and total energy detector techniques is the characterization and control of systematic uncertainties associated to the measuring devices. In this work we explore the most conspicuous effects associated to harsh count rate conditions: dead-time and pile-up effects. Both effects, when not properly treated, can lead to large systematic uncertainties and bias in the determination of neutron cross sections. In the majority of neutron capture measurements carried out at the CERN n\_TOF facility, the detectors of choice are the C$_{6}$D$_{6}$ liquid-based either in form of large-volume cells or recently commissioned sTED detector array, consisting of much smaller-volume modules. To account for the aforementioned effects, we introduce a Monte Carlo model for these detectors mimicking harsh count rate conditions similar to those happening at the CERN n\_TOF 20~m fligth path vertical measuring station. The model parameters are extracted by comparison with the experimental data taken at the same facility during 2022 experimental campaign. We propose a novel methodology to consider both, dead-time and pile-up effects simultaneously for these fast detectors and check the applicability to experimental data from $^{197}$Au($n$,$γ$), including the saturated 4.9~eV resonance which is an important component of normalization for neutron cross section measurements.
△ Less
Submitted 2 November, 2023;
originally announced November 2023.
-
Recent highlights and prospects on (n,$γ$) measurements at the CERN n_TOF facility
Authors:
J. Lerendegui-Marco,
V. Alcayne,
V. Babiano-Suarez,
M. Bacak,
J. Balibrea-Correa,
A. Casanovas,
C. Domingo-Pardo,
G. de la Fuente,
B. Gameiro,
F. García-Infantes,
I. Ladarescu,
E. Musacchio-Gonzalez,
J. A. Pavón-Rodríguez,
A. Tarifeño-Saldivia,
the n_TOF Collaboration
Abstract:
Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming th…
▽ More
Neutron capture cross-section measurements are fundamental in the study of the slow neutron capture (s-) process of nucleosynthesis and for the development of innovative nuclear technologies. One of the best suited methods to measure radiative neutron capture (n,$γ$) cross sections over the full stellar range of interest for all the applications is the time-of-flight (TOF) technique. Overcoming the current experimental limitations for TOF measurements, in particular on low mass unstable samples, requires the combination of facilities with high instantaneous flux, such as the CERN n_TOF facility, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution presents a summary about the recent highlights in the field of (n,$γ$) measurements at n_TOF. The recent upgrades in the facility and in new detector concepts for (n,\g) measurements are described. Last, an overview is given on the existing limitations and prospects for TOF measurements involving unstable targets and the outlook for activation measurements at the brand new high-flux n_TOF-NEAR station.
△ Less
Submitted 24 October, 2023;
originally announced October 2023.
-
Commissioning of miniBELEN-10A, a moderated neutron counter with a flat efficiency for thick-target neutron yields measurements
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
G Garcia,
E Nácher,
J L Tain,
V Alcayne,
O Alonso-Sañudo,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
J Gómez-Camacho,
E M González-Romero
, et al. (18 additional authors not shown)
Abstract:
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron…
▽ More
miniBELEN-10A is a modular and transportable moderated neutron counter with a nearly flat detection efficiency up to 8 MeV. The detector was designed to carry out measurements of (alpha, n) reactions in the context of the Measurement of Alpha Neutron Yields (MANY) project. In this work we present the results of the commissioning of miniBELEN-10A using the relatively well-known thick-target neutron yields from 27Al(alpha, n)30P.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
miniBELEN: a modular neutron counter for (alpha,n) reactions
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
L M Fraile,
S Viñals,
A Perea,
M Pallàs,
G Cortés,
E Nácher,
J L Tain,
V Alcayne,
A Algora,
J Balibrea-Correa,
J Benito,
M J G Borge,
J A Briz,
F Calviño,
D Cano-Ott,
A De Blas,
C Domingo-Pardo,
B Fernández,
R Garcia,
G García,
J Gómez-Camacho,
E M González-Romero,
C Guerrero
, et al. (16 additional authors not shown)
Abstract:
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming…
▽ More
miniBELEN is a modular and transportable neutron moderated counter with a nearly flat neutron detection efficiency up to 10 MeV. Modularity implies that the moderator can be reassembled in different ways in order to obtain different types of response. The detector has been developed in the context of the Measurement of Alpha Neutron Yields (MANY) collaboration, which is a scientific effort aiming to carry out measurements of (alpha,n) production yields, reaction cross-sections and neutron energy spectra. In this work we present and discuss several configurations of the miniBELEN detector. The experimental validation of the efficiency calculations using 252Cf sources and the measurement of the 27Al(alpha,n)30P reaction is also presented.
△ Less
Submitted 14 April, 2023;
originally announced April 2023.
-
New detection systems for an enhanced sensitivity in key stellar (n,$γ$) measurements
Authors:
J. Lerendegui-Marco,
V. Babiano-Suárez,
J. Balibrea-Correa,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
C. Guerrero,
F. Calviño,
A. Casanovas,
U. Köster,
N. M. Chiera,
R. Dressler,
E. A. Maugeri,
D. Schumann,
the n_TOF Collaboration
Abstract:
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and t…
▽ More
Neutron capture cross-section measurements are fundamental in the study of astrophysical phenomena, such as the slow neutron capture (s-) process of nucleosynthesis operating in red-giant and massive stars. However, neutron capture measurements via the time-of-flight (TOF) technique on key $s$-process nuclei are often challenging. Difficulties arise from the limited mass ($\sim$mg) available and the high sample-related background in the case of the unstable $s$-process branching points. Measurements on neutron magic nuclei, that act as $s$-process bottlenecks, are affected by low (n,$γ$) cross sections and a dominant neutron scattering background. Overcoming these experimental challenges requires the combination of facilities with high instantaneous flux, such as n\_TOF-EAR2, with detection systems with an enhanced detection sensitivity and high counting rate capabilities. This contribution reviews some of the latest detector developments in detection systems for (n,$γ$) measurements at n\_TOF, such as i-TED, an innovative detection system which exploits the Compton imaging technique to reduce the dominant neutron scattering background and s-TED, a highly segmented total energy detector intended for high flux facilities. The discussion will be illustrated with results of the first measurement of key the $s$-process branching-point reaction $^{79}$Se(n,$γ$).
△ Less
Submitted 15 March, 2023;
originally announced March 2023.
-
First measurement of the $^{94}$Nb($n$,$γ$) cross section at the CERN n\_TOF facility
Authors:
J. Balibrea-Correa,
V. Babiano-Suarez,
J. Lerendegui-Marco,
C. Domingo-Pardo,
I. Ladarescu,
A. Tarifeño-Saldivia,
V. Alcayne,
D. Cano-Ott,
E. González-Romero,
T. Martínez,
E. Mendoza,
J. Plaza,
A. Sánchez-Caballero,
F. Calviño,
A. Casanovas,
C. Guerrero,
S. Heinitz,
U. Köster,
E. A. Maugeri,
R. Dressler,
D. Schumann,
I. Mönch,
S. Cristallo,
C. Lederer-Woods,
O. Aberle
, et al. (112 additional authors not shown)
Abstract:
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along di…
▽ More
One of the crucial ingredients for the improvement of stellar models is the accurate knowledge of neutron capture cross-sections for the different isotopes involved in the $s$-,$r$- and $i$- processes. These measurements can shed light on existing discrepancies between observed and predicted isotopic abundances and help to constrain the physical conditions where these reactions take place along different stages of stellar evolution.In the particular case of the radioactive $^{94}$Nb, the $^{94}$Nb($n$,$γ$) cross-section could play a role in the determination of the $s$-process production of $^{94}$Mo in AGB stars, which presently cannot be reproduced by state-of-the-art stellar models. There are no previous $^{94}$Nb($n$,$γ$) experimental data for the resolved and unresolved resonance regions mainly due to the difficulties in producing high-quality samples and also due to limitations in conventional detection systems commonly used in time-of-flight experiments.Motivated by this situation, a first measurement of the $^{94}$Nb($n$,$γ$) reaction was carried out at CERN n\_TOF, thereby exploiting the high luminosity of the EAR2 area in combination with a new detection system of small-volume C6D6-detectors and a high quality $^{94}$Nb-sample. The latter was based on hyper-pure $^{93}$Nb material activated at the high-flux reactor of ILL-Grenoble. An innovative ring-configuration detection system in close geometry around the capture sample allowed us to significantly enhance the signal-to-background ratio. This set-up was supplemented with two conventional C$_{6}$D$_{6}$ detectors and a high-resolution LaCl$_{3}$(Ce)-detector, which will be employed for addressing reliably systematic effects and uncertainties.At the current status of the data analysis, 18 resonance in $^{94}$Nb+$n$ have been observed for the first time in the neutron energy range from thermal up to 10 keV.
△ Less
Submitted 20 February, 2023; v1 submitted 26 January, 2023;
originally announced January 2023.
-
Measurement of the $^{14}$N(n,p)$^{14}$C cross section at the CERN n_TOF facility from sub-thermal energy to 800 keV
Authors:
P. Torres-Sánchez,
J. Praena,
I. Porras,
M. Sabaté-Gilarte,
C. Lederer-Woods,
O. Aberle,
V. Alcayne,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
V. Bécares,
V. Babiano-Suarez,
M. Bacak,
M. Barbagallo,
F. Bečvář,
G. Bellia,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Busso,
M. Caamaño,
L. Caballero,
F. Calviño,
M. Calviani
, et al. (107 additional authors not shown)
Abstract:
Background: The $^{14}$N(n,p)$^{14}$C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring…
▽ More
Background: The $^{14}$N(n,p)$^{14}$C reaction is of interest in neutron capture therapy, where nitrogen-related dose is the main component due to low-energy neutrons, and in astrophysics, where 14N acts as a neutron poison in the s-process. Several discrepancies remain between the existing data obtained in partial energy ranges: thermal energy, keV region and resonance region. Purpose: Measuring the 14N(n,p)14C cross section from thermal to the resonance region in a single measurement for the first time, including characterization of the first resonances, and providing calculations of Maxwellian averaged cross sections (MACS). Method: Time-of-flight technique. Experimental Area 2 (EAR-2) of the neutron time-of-flight (n_TOF) facility at CERN. $^{10}$B(n,$α$)$^7$Li and $^{235}$U(n,f) reactions as references. Two detection systems running simultaneously, one on-beam and another off-beam. Description of the resonances with the R-matrix code sammy. Results: The cross section has been measured from sub-thermal energy to 800 keV resolving the two first resonances (at 492.7 and 644 keV). A thermal cross-section (1.809$\pm$0.045 b) lower than the two most recent measurements by slightly more than one standard deviation, but in line with the ENDF/B-VIII.0 and JEFF-3.3 evaluations has been obtained. A 1/v energy dependence of the cross section has been confirmed up to tens of keV neutron energy. The low energy tail of the first resonance at 492.7 keV is lower than suggested by evaluated values, while the overall resonance strength agrees with evaluations. Conclusions: Our measurement has allowed to determine the $^{14}$N(n,p) cross-section over a wide energy range for the first time. We have obtained cross-sections with high accuracy (2.5 %) from sub-thermal energy to 800 keV and used these data to calculate the MACS for kT = 5 to kT = 100 keV.
△ Less
Submitted 9 December, 2022;
originally announced December 2022.
-
Advances and new ideas for neutron-capture astrophysics experiments at CERN n_TOF
Authors:
C. Domingo-Pardo,
V. Babiano-Suarez,
J. Balibrea-Correa,
L. Caballero,
I. Ladarescu,
J. Lerendegui-Marco,
J. L. Tain,
A. Tarifeño-Saldivia,
O. Aberle,
V. Alcayne,
S. Altieri,
S. Amaducci,
J. Andrzejewski,
M. Bacak,
C. Beltrami,
S. Bennett,
A. P. Bernardes,
E. Berthoumieux,
M. Boromiza,
D. Bosnar,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
A. Casanovas
, et al. (114 additional authors not shown)
Abstract:
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also prese…
▽ More
This article presents a few selected developments and future ideas related to the measurement of $(n,γ)$ data of astrophysical interest at CERN n_TOF. The MC-aided analysis methodology for the use of low-efficiency radiation detectors in time-of-flight neutron-capture measurements is discussed, with particular emphasis on the systematic accuracy. Several recent instrumental advances are also presented, such as the development of total-energy detectors with $γ$-ray imaging capability for background suppression, and the development of an array of small-volume organic scintillators aimed at exploiting the high instantaneous neutron-flux of EAR2. Finally, astrophysics prospects related to the intermediate $i$ neutron-capture process of nucleosynthesis are discussed in the context of the new NEAR activation area.
△ Less
Submitted 3 August, 2022;
originally announced August 2022.
-
A novel modular neutron long counter for (α,n) reactions
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
F Calviño,
M Pallàs,
J L Tain
Abstract:
In this work, we present the design of a new modular and transportable neutron detector for (α,n) reactions. The detector is based on the use of several 3He-filled proportional counters embedded in high density polyethylene. In order to provide the detector with a response independent of the neutron energy, a flat response, an innovative design methodology has been applied. The method is based on…
▽ More
In this work, we present the design of a new modular and transportable neutron detector for (α,n) reactions. The detector is based on the use of several 3He-filled proportional counters embedded in high density polyethylene. In order to provide the detector with a response independent of the neutron energy, a flat response, an innovative design methodology has been applied. The method is based on the optimization of the counters contribution to the total efficiency by using thermal neutron absorbers. This allows to obtain flat responses up to 10 MeV. The characterization of a proof-of-concept prototype detector is presented. The perspectives for using this new detector for (α,n) reactions measurements are discussed.
△ Less
Submitted 4 May, 2022;
originally announced May 2022.
-
Long-term evolution of the neutron rate at the Canfranc Underground Laboratory
Authors:
S. E. A. Orrigo,
J. L. Tain,
N. Mont-Geli,
A. Tarifeño-Saldivia,
L. M. Fraile,
M. Grieger,
J. Agramunt,
A. Algora,
D. Bemmerer,
F. Calviño,
G. Cortés,
A. De Blas,
I. Dillmann,
A. Domínguez Bugarín,
R. García,
E. Nacher,
A. Tolosa-Delgado
Abstract:
We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-t…
▽ More
We report results on the long-term variation of the neutron counting rate at the Canfranc Underground Laboratory, of importance for several low-background experiments installed there, including rare-event searches. The measurement campaign was performed employing the High Efficiency Neutron Spectrometry Array (HENSA) mounted in Hall A and lasted 412 live days. The present study is the first long-term measurement of the neutron rate with sensitivity over a wide range of neutron energies (from thermal up to 0.1 GeV and beyond) performed in any underground laboratory so far. Data on the environmental variables inside the experimental hall (radon concentration, air temperature, air pressure and humidity) were also acquired during all the measurement campaign. We have investigated for the first time the evolution of the neutron rate for different energies of the neutrons and its correlation with the ambient variables.
△ Less
Submitted 29 August, 2022; v1 submitted 29 April, 2022;
originally announced April 2022.
-
Efficiency calibration of the BRIKEN detector: the world largest counter for beta-delayed neutrons
Authors:
M. Pallas,
A. Tarifeno-Saldivia,
F. Calvino,
N. Mont-Geli,
J. L. Tain,
A. Tolosa-Delgado,
J. Agramunt,
F. Molina,
P. Aguilera,
J. Romero-Barrientos
Abstract:
Beta-delayed neutron emission plays a fundamental role in the explosive nucleosynthesis of elements heavier than iron by the rapid neutron capture (r-process). The most ambitious project related to beta-delayed neutron detection of very exotic nuclei is carried out by the BRIKEN collaboration at RIKEN Nishima Center. In this work, a brief description of the BRIKEN project is presented. A methodolo…
▽ More
Beta-delayed neutron emission plays a fundamental role in the explosive nucleosynthesis of elements heavier than iron by the rapid neutron capture (r-process). The most ambitious project related to beta-delayed neutron detection of very exotic nuclei is carried out by the BRIKEN collaboration at RIKEN Nishima Center. In this work, a brief description of the BRIKEN project is presented. A methodology for the precise characterization of the BRIKEN neutron counter efficiency, for fast neutrons, using an uncalibrated 252Cf neutron source is described. The method relies on the well-known neutron multiplicity distribution of such source and correlation counting method. A detailed experimental study with the BRIKEN neutron counter and a 252 Cf neutron source at the RIKEN Nishina center is presented. The result of this work is the determination of the neutron detection efficiency of the BRIKEN neutron counter with high accuracy.
△ Less
Submitted 28 April, 2022;
originally announced April 2022.
-
High accuracy, high resolution 235U(n,f) cross section from n_TOF (CERN) in the thermal to 10 keV energy range
Authors:
n_TOF collaboration,
:,
M. Mastromarco,
S. Amaducci,
N. Colonna,
P. Finocchiaro,
L. Cosentino,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Bacak,
J. Balibrea,
M. Barbagallo,
F. Bečvář,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
R. Cardella,
A. Casanovas,
F. Cerutti
, et al. (98 additional authors not shown)
Abstract:
The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. In this paper we report on the results in the region between thermal and 10 keV neutron energy…
▽ More
The 235U(n,f) cross section was measured in a wide energy range (25 meV - 170 keV) at the n_TOF facility at CERN, relative to 6Li(n,t) and 10B(n,alpha) standard reactions, with high resolution and accuracy, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. In this paper we report on the results in the region between thermal and 10 keV neutron energy. A resonance analysis has been performed up to 200 eV, with the code SAMMY. The resulting fission kernels are compared with the ones extracted on the basis of the resonance parameters of the most recent major evaluated data libraries. A comparison of the n_TOF data with the evaluated cross sections is also performed from thermal to 10 keV neutron energy for the energy-averaged cross section in energy groups of suitably chosen width. A good agreement is found in average between the new results and the latest evaluated data files ENDF-B/VIII and JEFF-3.3, as well as with respect to the IAEA reference files. However, some discrepancies are still present in some specific energy regions. The new dataset here presented, characterized by unprecedented resolution and accuracy, can help improving the evaluations in the Resolved Resonance Region and up to 10 keV, and reduce the uncertainties that affect this region.
△ Less
Submitted 2 February, 2022;
originally announced February 2022.
-
First results from the HENSA/ANAIS collaboration at the Canfranc Underground Laboratory
Authors:
N Mont-Geli,
A Tarifeño-Saldivia,
S E A Orrigo,
J L Tain,
M Grieger,
J Agramunt,
A Algora,
J Amaré,
D Bemmerer,
F Calviño,
S Cebrián,
I Coarasa,
G Cortés,
A De Blas,
I Dillmann,
L M Fraile,
E García,
R García,
M Martínez,
E Nacher,
Y Ortigoza,
A Ortiz,
M Pallàs,
J Puimedón,
A Salinas
, et al. (2 additional authors not shown)
Abstract:
The HENSA/ANAIS collaboration aims for the precise determination of the neutron flux that could affect ANAIS-112, an experiment looking for the dark matter annual modulation using NaI(Tl) scintillators. In this work, the first measurements of the neutron flux and Monte Carlo simulations of the neutron spectrum are reported.
The HENSA/ANAIS collaboration aims for the precise determination of the neutron flux that could affect ANAIS-112, an experiment looking for the dark matter annual modulation using NaI(Tl) scintillators. In this work, the first measurements of the neutron flux and Monte Carlo simulations of the neutron spectrum are reported.
△ Less
Submitted 3 February, 2022; v1 submitted 24 November, 2021;
originally announced November 2021.
-
Measurement of the neutron flux at the Canfranc Underground Laboratory with HENSA
Authors:
S. E. A. Orrigo,
J. L. Tain,
N. Mont-Geli,
A. Tarifeño-Saldivia,
L. M. Fraile,
M. Grieger,
J. Agramunt,
A. Algora,
D. Bemmerer,
F. Calviño,
G. Cortés,
A. De Blas,
I. Dillmann,
A. Domínguez Bugarín,
R. García,
E. Nacher,
A. Tolosa
Abstract:
We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In P…
▽ More
We have performed a long-term measurement of the neutron flux with the High Efficiency Neutron Spectrometry Array HENSA in the Hall A of the Canfranc Underground Laboratory. The Hall A measurement campaign lasted from October 2019 to March 2021, demonstrating an excellent stability of the HENSA setup. Preliminary results on the neutron flux from this campaign are presented for the first time. In Phase 1 (113 live days) a total neutron flux of 1.66(2) $\times$10$^{-5}$ cm$^{-2}$ s$^{-1}$ is obtained. Our results are in good agreement with those from our previous shorter measurement where a reduced experimental setup was employed.
△ Less
Submitted 17 November, 2021;
originally announced November 2021.
-
Imaging neutron capture cross sections: i-TED proof-of-concept and future prospects based on Machine-Learning techniques
Authors:
V. Babiano-Suárez,
J. Lerendegui-Marco,
J. Balibrea-Correa,
L. Caballero,
D. Calvo,
I. Ladarescu,
C. Domingo-Pardo,
F. Calviño,
A. Casanovas,
A. Tarifeño-Saldivia,
V. Alcayne,
C. Guerrero,
M. A. Millán-Callado,
M. T. Rodríguez González,
M. Barbagallo,
O. Aberle,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
M. Bacak,
S. Bennett,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown
, et al. (110 additional authors not shown)
Abstract:
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background reje…
▽ More
i-TED is an innovative detection system which exploits Compton imaging techniques to achieve a superior signal-to-background ratio in ($n,γ$) cross-section measurements using time-of-flight technique. This work presents the first experimental validation of the i-TED apparatus for high-resolution time-of-flight experiments and demonstrates for the first time the concept proposed for background rejection. To this aim both $^{197}$Au($n,γ$) and $^{56}$Fe($n, γ$) reactions were measured at CERN n\_TOF using an i-TED demonstrator based on only three position-sensitive detectors. Two \cds detectors were also used to benchmark the performance of i-TED. The i-TED prototype built for this study shows a factor of $\sim$3 higher detection sensitivity than state-of-the-art \cds detectors in the $\sim$10~keV neutron energy range of astrophysical interest. This paper explores also the perspectives of further enhancement in performance attainable with the final i-TED array consisting of twenty position-sensitive detectors and new analysis methodologies based on Machine-Learning techniques.
△ Less
Submitted 18 December, 2020;
originally announced December 2020.
-
Review and new concepts for neutron-capture measurements of astrophysical interest
Authors:
C. Domingo-Pardo,
V. Babiano-Suarez,
J. Balibrea-Correa,
L. Caballero,
I. Ladarescu,
J. Lerendegui-Marco,
J. L. Tain,
F. Calviño,
A. Casanovas,
A. Segarra,
A. E. Tarifeño-Saldivia,
C. Guerrero,
M. A. Millán-Callado,
J. M. Quesada,
M. T. Rodríguez-González,
O. Aberle,
V. Alcayne,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
M. Bacak,
M. Barbagallo,
S. Bennett,
E. Berthoumieux,
D. Bosnar
, et al. (106 additional authors not shown)
Abstract:
The idea of slow-neutron capture nucleosynthesis formulated in 1957 triggered a tremendous experimental effort in different laboratories worldwide to measure the relevant nuclear physics input quantities, namely ($n,γ$) cross sections over the stellar temperature range (from few eV up to several hundred keV) for most of the isotopes involved from Fe up to Bi. A brief historical review focused on t…
▽ More
The idea of slow-neutron capture nucleosynthesis formulated in 1957 triggered a tremendous experimental effort in different laboratories worldwide to measure the relevant nuclear physics input quantities, namely ($n,γ$) cross sections over the stellar temperature range (from few eV up to several hundred keV) for most of the isotopes involved from Fe up to Bi. A brief historical review focused on total energy detectors will be presented to illustrate how, advances in instrumentation have led, over the years, to the assessment and discovery of many new aspects of $s$-process nucleosynthesis and to the progressive refinement of theoretical models of stellar evolution. A summary will be presented on current efforts to develop new detection concepts, such as the Total-Energy Detector with $γ$-ray imaging capability (i-TED). The latter is based on the simultaneous combination of Compton imaging with neutron time-of-flight (TOF) techniques, in order to achieve a superior level of sensitivity and selectivity in the measurement of stellar neutron capture rates.
△ Less
Submitted 16 November, 2019;
originally announced November 2019.
-
Measurement of the 235U(n,f) cross section relative to the 6Li(n,t) and 10B(n,alpha) standards from thermal to 170 keV neutron energy range at n_TOF
Authors:
S. Amaducci,
L. Cosentino,
M. Barbagallo,
N. Colonna,
A. Mengoni,
C. Massimi,
S. Lo Meo,
P. Finocchiaro,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Bacak,
J. Balibrea,
F. Bečvář,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Caamaño,
F. Calviño,
M. Calviani,
D. Cano-Ott,
R. Cardella,
A. Casanovas,
F. Cerutti
, et al. (96 additional authors not shown)
Abstract:
The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the reaction yields under the same experimental conditions, and taking into account the forwa…
▽ More
The 235U(n,f) cross section was measured in a wide energy range at n_TOF relative to 6Li(n,t) and 10B(n,alpha), with high resolution and in a wide energy range, with a setup based on a stack of six samples and six silicon detectors placed in the neutron beam. This allowed us to make a direct comparison of the reaction yields under the same experimental conditions, and taking into account the forward/backward emission asymmetry. A hint of an anomaly in the 10÷30 keV neutron energy range had been previously observed in other experiments, indicating a cross section systematically lower by several percent relative to major evaluations. The present results indicate that the evaluated cross section in the 9÷18 keV neutron energy range is indeed overestimated, both in the recent updates of ENDF/B-VIII.0 and of the IAEA reference data. Furthermore, these new high-resolution data confirm the existence of resonance-like structures in the keV neutron energy region. The new, high accuracy results here reported may lead to a reduction of the uncertainty in the 1÷100 keV neutron energy region. Finally, the present data provide additional confidence on the recently re-evaluated cross section integral between 7.8 and 11 eV.
△ Less
Submitted 4 March, 2019; v1 submitted 27 February, 2019;
originally announced February 2019.
-
Commissioning of the BRIKEN detector for the measurement of very exotic beta-delayed neutron emitters
Authors:
A. Tolosa-Delgado,
J. Agramunt,
J. L. Tain,
A. Algora,
C. Domingo-Pardo,
A. I. Morales,
B. Rubio,
A. Tarifeno-Saldivia,
F. Calvino,
G. Cortes,
N. T. Brewer,
B. C. Rasco,
K. P. Rykaczewski,
D. W. Stracener,
J. M. Allmond,
R. Grzywacz,
R. Yokoyama,
M. Singh,
T. King,
M. Madurga,
S. Nishimura,
V. H. Phong,
S. Go,
J. Liu,
K. Matsui
, et al. (41 additional authors not shown)
Abstract:
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demo…
▽ More
A new detection system has been installed at the RIKEN Nishina Center (Japan) to investigate decay properties of very neutron-rich nuclei. The setup consists of three main parts: a moderated neutron counter, a detection system sensitive to the implantation and decay of radioactive ions, and gamma-ray detectors. We describe here the setup, the commissioning experiment and some selected results demonstrating its performance for the measurement of half-lives and beta-delayed neutron emission probabilities. The methodology followed in the analysis of the data is described in detail. Particular emphasis is placed on the correction of the accidental neutron background.
△ Less
Submitted 2 August, 2018;
originally announced August 2018.
-
The $^{7}$Be($\boldsymbol{n,p}$)$^{7}$Li reaction and the Cosmological Lithium Problem: measurement of the cross section in a wide energy range at n_TOF (CERN)
Authors:
L. Damone,
M. Barbagallo,
M. Mastromarco,
A. Mengoni,
L. Cosentino,
E. Maugeri,
S. Heinitz,
D. Schumann,
R. Dressler,
F. Käppeler,
N. Colonna,
P. Finocchiaro,
J. Andrzejewski,
J. Perkowski,
A. Gawlik,
O. Aberle,
S. Altstadt,
M. Ayranov,
L. Audouin,
M. Bacak,
J. Balibrea-Correa,
J. Ballof,
V. Bécares,
F. Bečvář,
C. Beinrucker
, et al. (133 additional authors not shown)
Abstract:
We report on the measurement of the $^{7}$Be($n, p$)$^{7}$Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n\_TOF facility at CERN. This reaction plays a key role in the lithium yield of the Big Bang Nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this react…
▽ More
We report on the measurement of the $^{7}$Be($n, p$)$^{7}$Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n\_TOF facility at CERN. This reaction plays a key role in the lithium yield of the Big Bang Nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and showed a large discrepancy between each other. The measurement was performed with a Si-telescope, and a high-purity sample produced by implantation of a $^{7}$Be ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low-energy, relative to current evaluations, in the region of BBN interest the present results are consistent with the values inferred from the time-reversal $^{7}$Li($p, n$)$^{7}$Be reaction, thus yielding only a relatively minor improvement on the so-called Cosmological Lithium Problem (CLiP). The relevance of these results on the near-threshold neutron production in the p+$^{7}$Li reaction is also discussed.
△ Less
Submitted 8 June, 2018;
originally announced June 2018.
-
Cross section measurements of $^{155,157}$Gd(n,$γ$) induced by thermal and epithermal neutrons
Authors:
M. Mastromarco,
A. Manna,
O. Aberle,
S. Amaducci,
J. Andrzejewski,
L. Audouin,
M. Bacak,
J. Balibrea,
M. Barbagallo,
F. Becvar,
E. Berthoumieux,
J. Billowes,
D. Bosnar,
A. Brown,
M. Caamano,
F. Calvino,
M. Calviani,
D. Cano-Ott,
R. Cardella,
A. Casanovas,
D. M. Castelluccio,
F. Cerutti,
Y. H. Chen,
E. Chiaveri,
G. Clai
, et al. (99 additional authors not shown)
Abstract:
Neutron capture measurements on $^{155}$Gd and $^{157}$Gd were performed using the time-of-flight technique at the n\_TOF facility at CERN. Four samples in form of self-sustaining metallic discs isotopically enriched in $^{155}$Gd and $^{157}$Gd were used. The measurements were carried out at the experimental area (EAR1) at 185 m from the neutron source, with an array of 4 C$_6$D$_6$ liquid scinti…
▽ More
Neutron capture measurements on $^{155}$Gd and $^{157}$Gd were performed using the time-of-flight technique at the n\_TOF facility at CERN. Four samples in form of self-sustaining metallic discs isotopically enriched in $^{155}$Gd and $^{157}$Gd were used. The measurements were carried out at the experimental area (EAR1) at 185 m from the neutron source, with an array of 4 C$_6$D$_6$ liquid scintillation detectors.
The capture cross sections of $^{155}$Gd and $^{157}$Gd at neutron kinetic energy of 0.0253 eV have been estimated to be 62.2(2.2) kb and 239.8(9.3) kb, respectively, thus up to 6\% different relative to the ones reported in the nuclear data libraries. A resonance shape analysis has been performed in the resolved resonance region up to 180 eV and 300 eV, respectively, in average resonance parameters have been found in good agreement with evaluations. Above these energies the observed resonance-like structures in the cross section have been tentatively characterised in terms of resonance energy and area up to 1 keV.
△ Less
Submitted 10 May, 2018;
originally announced May 2018.
-
First determination of $β$-delayed multiple neutron emission beyond A = 100 through direct neutron measurement: The P$_{2n}$ value of $^{136}$Sb
Authors:
R. Caballero-Folch,
I. Dillmann,
J. Agramunt,
J. L. Taín,
A. Algora,
J. Äystö,
F. Calviño,
L. Canete,
G. Cortès,
C. Domingo-Pardo,
T. Eronen,
E. Ganioglu,
W. Gelletly,
D. Gorelov,
V. Guadilla,
J. Hakala,
A. Jokinen,
A. Kankainen,
V. Kolhinen,
J. Koponen,
M. Marta,
E. Mendoza,
A. Montaner-Pizá,
I. Moore,
C. R. Nobs
, et al. (12 additional authors not shown)
Abstract:
Background: $β$-delayed multiple neutron emission has been observed for some nuclei with A$\leq$100, with $^{100}$Rb being the heaviest $β$2n emitter measured to date. So far, only 25 P$_{2n}$ values have been determined for the $\sim$300 nuclei that may decay in this way. Accordingly, it is of interest to measure P$_{2n}$ values for the other possible multiple neutron emitters throughout the char…
▽ More
Background: $β$-delayed multiple neutron emission has been observed for some nuclei with A$\leq$100, with $^{100}$Rb being the heaviest $β$2n emitter measured to date. So far, only 25 P$_{2n}$ values have been determined for the $\sim$300 nuclei that may decay in this way. Accordingly, it is of interest to measure P$_{2n}$ values for the other possible multiple neutron emitters throughout the chart of the nuclides. It is of particular interest to make such measurement for nuclei with A$>$100 to test the predictions of theoretical models and simulation tools for the decays of heavy nuclei in the region of very neutron-rich nuclei. In addition, the decay properties of these nuclei are fundamental for the understanding of astrophysical nucleosynthesis processes such as the $r$-process, and safety inputs for nuclear reactors. Purpose: To determine for the first time the two neutron branching ratio, P$_{2n}$ value, for $^{136}$Sb through a direct neutron measurement, and to provide precise P$_{1n}$ values for $^{136}$Sb and $^{136}$Te. Method: Pure beams were provided by the JYFLTRAP at the IGISOL facility of the University of Jyväskylä, Finland. The purified ions were implanted into a moving tape at the end of the beam line. The detection setup consisted of a plastic scintillator placed right behind the implantation point, and the BELEN detector, based on neutron counters embedded in a polyethylene matrix. The analysis was based on the study of the $β$- and neutron- growth-and-decay curves and the $β$-one-neutron and $β$-two-neutron time correlations. Results: The P$_{2n}$ value of $^{136}$Sb was found to be 0.14(3)\% and the measured P$_{1n}$ values for $^{136}$Sb and $^{136}$Te were found to be 32.2(15)\% and 1.47(6)\%, respectively. The measured P$_{2n}$ value is a factor 44 smaller than predicted by the FRDM+QRPA model used for $r$-process calculations.
△ Less
Submitted 17 September, 2018; v1 submitted 19 March, 2018;
originally announced March 2018.
-
The $^{7}$Be(n,p)$^{7}$Li reaction and the Cosmological Lithium Problem: measurement of the cross section in a wide energy range at n_TOF (CERN)
Authors:
L. Damone,
M. Barbagallo,
M. Mastromarco,
A. Mengoni,
L. Cosentino,
E. Maugeri,
S. Heinitz,
D. Schumann,
R. Dressler,
F. Käppeler,
N. Colonna,
P. Finocchiaro,
J. Andrzejewski,
J. Perkowski,
A. Gawlik,
O. Aberle,
S. Altstadt,
M. Ayranov,
L. Audouin,
M. Bacak,
J. Balibrea-Correa,
J. Ballof,
V. Bécares,
F. Bečvář,
C. Beinrucker
, et al. (133 additional authors not shown)
Abstract:
We report on the measurement of the $^{7}$Be($n, p$)$^{7}$Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n_TOF facility at CERN. This reaction plays a key role in the lithium yield of the Big Bang Nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reacti…
▽ More
We report on the measurement of the $^{7}$Be($n, p$)$^{7}$Li cross section from thermal to approximately 325 keV neutron energy, performed in the high-flux experimental area (EAR2) of the n_TOF facility at CERN. This reaction plays a key role in the lithium yield of the Big Bang Nucleosynthesis (BBN) for standard cosmology. The only two previous time-of-flight measurements performed on this reaction did not cover the energy window of interest for BBN, and showed a large discrepancy between each other. The measurement was performed with a Si-telescope, and a high-purity sample produced by implantation of a $^{7}$Be ion beam at the ISOLDE facility at CERN. While a significantly higher cross section is found at low-energy, relative to current evaluations, in the region of BBN interest the present results are consistent with the values inferred from the time-reversal $^{7}$Li($p, n$)$^{7}$Be reaction, thus yielding only a relatively minor improvement on the so-called Cosmological Lithium Problem (CLiP). The relevance of these results on the near-threshold neutron production in the p+$^{7}$Li reaction is also discussed.
△ Less
Submitted 12 January, 2022; v1 submitted 15 March, 2018;
originally announced March 2018.
-
Experimental setup and procedure for the measurement of the 7Be(n,p)7Li reaction at n_TOF
Authors:
M. Barbagallo,
J. Andrzejewski,
M. Mastromarco,
J. Perkowski,
L. A. Damone,
A. Gawlik,
L. Cosentino,
P. Finocchiaro,
E. A. Maugeri,
A. Mazzone,
R. Dressler,
S. Heinitz,
N. Kivel,
D. Schumann,
N. Colonna,
O. Aberle,
S. Amaducci,
L. Audouin,
M. Bacak,
J. Balibrea,
F. Bečvář,
G. Bellia,
E. Berthoumieux,
J. Billowes,
D. Bosnar
, et al. (103 additional authors not shown)
Abstract:
Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available in EAR2 allows to investigate neutron indiced reactions with charged particles in the exit channel even employing targets made out of small amounts of short-liv…
▽ More
Following the completion of the second neutron beam line and the related experimental area (EAR2) at the n_TOF spallation neutron source at CERN, several experiments were planned and performed. The high instantaneous neutron flux available in EAR2 allows to investigate neutron indiced reactions with charged particles in the exit channel even employing targets made out of small amounts of short-lived radioactive isotopes. After the successful measurement of the 7Be(n,α)α cross section, the 7Be(n,p)7Li reaction was studied in order to provide still missing cross section data of relevance for Big Bang Nucleosynthesis (BBN), in an attempt to find a solution to the cosmological Lithium abundance problem. This paper describes the experimental setup employed in such a measurement and its characterization.
△ Less
Submitted 3 August, 2017;
originally announced August 2017.
-
Conceptual design of the BRIKEN detector: A hybrid neutron-gamma detection system for nuclear physics at the RIB facility of RIKEN
Authors:
A. Tarifeño-Saldivia,
J. L. Tain,
C. Domingo-Pardo,
F. Calviño,
G. Cortes,
V. H. Phong,
A. Riego,
The BRIKEN collaboration
Abstract:
BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, $β$-particles, $γ$-rays and $β$-delayed neutrons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix…
▽ More
BRIKEN is a complex detection system to be installed at the RIB-facility of the RIKEN Nishina Center. It is aimed at the detection of heavy-ion implants, $β$-particles, $γ$-rays and $β$-delayed neutrons. The whole detection setup involves the Advanced Implantation Detection Array (AIDA), two HPGe Clover detectors and a large set of 166 counters of 3He embedded in a high-density polyethylene matrix. This article reports on a novel methodology developed for the conceptual design and optimisation of the 3He-tubes array, aiming at the best possible performance in terms of neutron detection. The algorithm is based on a geometric representation of two selected parameters of merit, namely, average neutron detection efficiency and efficiency flatness, as a function of a reduced number of geometric variables. The response of the detection system itself, for each configuration, is obtained from a systematic MC-simulation implemented realistically in Geant4. This approach has been found to be particularly useful. On the one hand, due to the different types and large number of 3He-tubes involved and, on the other hand, due to the additional constraints introduced by the ancillary detectors for charged particles and gamma-rays. Empowered by the robustness of the algorithm, we have been able to design a versatile detection system, which can be easily re-arranged into a compact mode in order to maximize the neutron detection performance, at the cost of the gamma-ray sensitivity. In summary, we have designed a system which shows, for neutron energies up to 1(5) MeV, a rather flat and high average efficiency of 68.6%(64%) and 75.7%(71%) for the hybrid and compact modes, respectively. The performance of the BRIKEN system has been also quantified realistically by means of MC-simulations made with different neutron energy distributions.
△ Less
Submitted 16 June, 2016;
originally announced June 2016.
-
Experimental setup and procedure for the measurement of the 7Be(n,α)α reaction at n_TOF
Authors:
L. Cosentino,
A. Musumarra,
M. Barbagallo,
A. Pappalardo,
N. Colonna,
L. Damone,
M. Piscopo,
P. Finocchiaro,
E. Maugeri,
S. Heinitz,
D. Schumann,
R. Dressler,
N. Kivel,
O. Aberle,
J. Andrzejewski,
L. Audouin,
M. Ayranov,
M. Bacak,
S. Barros,
J. Balibrea-Correa,
V. Beecares,
F. Becvar,
C. Beinrucker,
E. Berthoumieux,
J. Billowes
, et al. (107 additional authors not shown)
Abstract:
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the…
▽ More
The newly built second experimental area EAR2 of the n_TOF spallation neutron source at CERN allows to perform (n, charged particles) experiments on short-lived highly radioactive targets. This paper describes a detection apparatus and the experimental procedure for the determination of the cross-section of the 7Be(n,α) reaction, which represents one of the focal points toward the solution of the cosmological Lithium abundance problem, and whose only measurement, at thermal energy, dates back to 1963. The apparently unsurmountable experimental difficulties stemming from the huge 7Be γ-activity, along with the lack of a suitable neutron beam facility, had so far prevented further measurements. The detection system is subject to considerable radiation damage, but is capable of disentangling the rare reaction signals from the very high background. This newly developed setup could likely be useful also to study other challenging reactions requiring the detectors to be installed directly in the neutron beam.
△ Less
Submitted 1 April, 2016;
originally announced April 2016.
-
First tests of the applicability of $γ$-ray imaging for background discrimination in time-of-flight neutron capture measurements
Authors:
D. L. Pérez Magán,
L. Caballero-Ontanaya,
C. Domingo-Pardo,
J. Agramunt-Ros,
F. Albiol,
A. Casanovas,
A. González,
C. Guerrero,
J. Lerendegui-Marco,
A. Tarifeño-Saldivia,
the n_TOF Collaboration
Abstract:
In this work we explore for the first time the applicability of using $γ$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplie…
▽ More
In this work we explore for the first time the applicability of using $γ$-ray imaging in neutron capture measurements to identify and suppress spatially localized background. For this aim, a pinhole gamma camera is assembled, tested and characterized in terms of energy and spatial performance. It consists of a monolithic CeBr$_3$ scintillating crystal coupled to a position-sensitive photomultiplier and readout through an integrated circuit AMIC2GR. The pinhole collimator is a massive carven block of lead. A series of dedicated measurements with calibrated sources and with a neutron beam incident on a $^{197}$Au sample have been carried out at n_TOF, achieving an enhancement of a factor of two in the signal-to-background ratio when selecting only those events coming from the direction of the sample.
△ Less
Submitted 14 October, 2015; v1 submitted 8 October, 2015;
originally announced October 2015.
-
Methodology for the use of proportional counters in pulsed fast neutron yield measurements
Authors:
Ariel Tarifeño-Saldivia,
Roberto E. Mayer,
Cristian Pavez,
Leopoldo Soto
Abstract:
This paper introduces in full detail a methodology for the measurement of neutron yield and the necessary efficiency calibration, to be applied to the intensity measurement of neutron bursts where individual neutrons are not resolved in time, for any given moderated neutron proportional counter array. The method allows efficiency calibration employing the detection neutrons arising from an isotopi…
▽ More
This paper introduces in full detail a methodology for the measurement of neutron yield and the necessary efficiency calibration, to be applied to the intensity measurement of neutron bursts where individual neutrons are not resolved in time, for any given moderated neutron proportional counter array. The method allows efficiency calibration employing the detection neutrons arising from an isotopic neutron source. Full statistical study of the procedure is descripted, taking into account contributions arising from counting statistics, piling-up statistics of real detector pulse-height spectra and background fluctuations. The useful information is extracted from the net waveform area of the signal arising from the electric charge accumulated inside the detector tube. Improvement of detection limit is gained, therefore this detection system can be used in detection of low emission neutron pulsed sources with pulses of duration from nanoseconds to up. The application of the methodology to detection systems to be applied for D-D fusion neutrons from plasma focus devices is described. The present work is also of interest to the nuclear community working on fusion by magnetic confinement and lasers, and working on neutron production by accelerators or similar devices.
△ Less
Submitted 11 October, 2011;
originally announced October 2011.