-
Creation of double-well potentials in a surface-electrode trap towards a nanofriction model emulator
Authors:
U. Tanaka,
M. Nakamura,
K. Hayasaka,
A. Bautista-Salvadora,
C. Ospelkaus,
T. E. Mehlstäubler
Abstract:
We demonstrate a microfabricated surface-electrode ion trap that is applicable as a nanofriction emulator and studies of many-body dynamics of interacting systems. The trap enables both single-well and double-well trap** potentials in the radial direction, where the distance between the two potential wells can be adjusted by the applied RF voltage. In the double-well configuration, parallel ion…
▽ More
We demonstrate a microfabricated surface-electrode ion trap that is applicable as a nanofriction emulator and studies of many-body dynamics of interacting systems. The trap enables both single-well and double-well trap** potentials in the radial direction, where the distance between the two potential wells can be adjusted by the applied RF voltage. In the double-well configuration, parallel ion strings can be formed, which is a suitable system for the emulation of the Frenkel-Kontorova (FK) model. We derive the condition under which the trap functions as a FK model emulator. The trap is designed so that the Coulomb interaction between two ion strings becomes significant. We report on the microfabrication process for such downsized trap electrodes and experimental results of single-well and double-well operation with calcium ions. With the trap demonstrated in this work we can create atomically accessible, self-assembled Coulomb systems with a wide tuning range of the corrugation parameter in the FK model. This makes it a promising system for quantum simulations, but also for the study of nanofriction in one and higher dimensional systems.
△ Less
Submitted 2 January, 2021;
originally announced January 2021.
-
Gromov's Problem: Bound the Expansion Coefficient from below in terms of the Observable Diameter of a Metric Measure Space, and its Diameter Bounds
Authors:
Ushio Tanaka
Abstract:
In the celebrated book entitled Metric Structures for Riemannian and Non-Riemannian Spaces, so-called Green Book, Gromov presented a problem regarding a metric measure space. Gromov posed the question Bound the expansion coefficient from below in terms of the observable diameter. The overall aim of the current study is to demonstrate the answer to this problem. To begin solving this problem, the c…
▽ More
In the celebrated book entitled Metric Structures for Riemannian and Non-Riemannian Spaces, so-called Green Book, Gromov presented a problem regarding a metric measure space. Gromov posed the question Bound the expansion coefficient from below in terms of the observable diameter. The overall aim of the current study is to demonstrate the answer to this problem. To begin solving this problem, the concentration of measure phenomenon on the metric measure space must be considered. The concentration function to evaluate the measure phenomenon is connected by the observable diameter and the expansion coefficient. Furthermore, the procedure for our answer gives us the upper bound for the expansion coefficient in terms of the observable diameter. Combining the desired lower bound for the expansion coefficient with its upper bound, we eventually obtain the upper bound for the observable diameter. Simultaneously, this reasoning has enabled us to obtain the upper bound for the diameter of a bounded metric measure space in terms of the expansion coefficient. We will apply the above-mentioned results to a compact connected Riemannian manifold with non-negative Ricci curvature, which makes the bounds more explicit. More precisely, they are in terms of the doubling constant of the Riemannian measure and the first non-trivial eigenvalue of the Laplacian on the Riemannian manifold.
△ Less
Submitted 17 November, 2016;
originally announced November 2016.
-
Surface-electrode trap with an integrated permanent magnet for generating a magnetic-field gradient at trapped ions
Authors:
Yuji Kawai,
Kenji Shimizu,
Atsushi Noguchi,
Shinji Urabe,
Utako Tanaka
Abstract:
We report on a surface-electrode trap with SmCo magnets arranged in a quadrupole configuration underneath the trap electrode. Because the distance between the magnets and the trapped ions can be as little as several hundred micrometers, a large magnetic field is produced without any heat management. The magnetic-field gradient was measured using the Zeeman splitting of a single trapped $^{40}$Ca…
▽ More
We report on a surface-electrode trap with SmCo magnets arranged in a quadrupole configuration underneath the trap electrode. Because the distance between the magnets and the trapped ions can be as little as several hundred micrometers, a large magnetic field is produced without any heat management. The magnetic-field gradient was measured using the Zeeman splitting of a single trapped $^{40}$Ca$^+$ ion at several positions, and a field gradient of 36 T/m was obtained. Such a field gradient is useful for the generation of a state-dependent force, which is important for quantum simulation and/or quantum gate operation using radio-frequency or microwave radiation.
△ Less
Submitted 1 October, 2016;
originally announced October 2016.
-
Testing the stability of fundamental constants with the 199Hg+ single-ion optical clock
Authors:
S. Bize,
S. A. Diddams,
U. Tanaka,
C. E. Tanner,
W. H. Oskay,
R. E. Drullinger,
T. E. Parker,
T. P. Heavner,
S. R. Jefferts,
L. Hollberg,
W. M. Itano,
D. J. Wineland,
J. C. Bergquist
Abstract:
Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertai…
▽ More
Over a two-year duration, we have compared the frequency of the 199Hg+ 5d106s 2S 1/2 (F=0)<-> 5d9 6s2 2D 5/2 (F=2) electric-quadrupole transition at 282 nm with the frequency of the ground-state hyperfine splitting in neutral 133Cs. These measurements show that any fractional time variation of the ratio nu(Cs)/nu(Hg) between the two frequencies is smaller than +/- 7 10^-15 / yr (1 sigma uncertainty). According to recent atomic structure calculations, this sets an upper limit to a possible fractional time variation of g(Cs) m_e / m_p alpha^6.0 at the same level.
△ Less
Submitted 30 December, 2002;
originally announced December 2002.