Skip to main content

Showing 1–4 of 4 results for author: Takemoto, A

.
  1. arXiv:1706.06483  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Performance measurement of HARPO: a Time Projection Chamber as a gamma-ray telescope and polarimeter

    Authors: P. Gros, S. Amano, D. Attié, P. Baron, D. Baudin, D. Bernard, P. Bruel, D. Calvet, P. Colas, S. Daté, A. Delbart, M. Frotin, Y. Geerebaert, B. Giebels, D. Götz, S. Hashimoto, D. Horan, T. Kotaka, M. Louzir, F. Magniette, Y. Minamiyama, S. Miyamoto, H. Ohkuma, P. Poilleux, I. Semeniouk , et al. (5 additional authors not shown)

    Abstract: We analyse the performance of a gas time projection chamber (TPC) as a high-performance gamma-ray telescope and polarimeter in the e$^+$e$^-$ pair creation regime. We use data collected at a gamma-ray beam of known polarisation. The TPC provides two orthogonal projections $(x,z)$ and $(y,z)$ of the tracks induced by each conversion in the gas volume. We use a simple vertex finder in which vertices… ▽ More

    Submitted 30 August, 2017; v1 submitted 20 June, 2017; originally announced June 2017.

    Comments: Submitted to Astroparticle Physics

  2. arXiv:1606.09417  [pdf, other

    astro-ph.IM physics.ins-det

    First measurement of polarisation asymmetry of a gamma-ray beam between 1.74 to 74 MeV with the HARPO TPC

    Authors: Philippe Gros, Sho Amano, David Attié, Denis Bernard, Philippe Bruel, Denis Calvet, Paul Colas, Schin Daté, Alain Delbart, Mickael Frotin, Yannick Geerebaert, Berrie Giebels, Diego Götz, S. Hashimoto, Deirdr Horan, T. Kotaka, Marc Louzir, Y. Minamiyama, Shuji Miyamoto, H. Ohkuma, Patrick Poilleux, Igor Semeniouk, Patrick Sizun, A. Takemoto, M. Yamaguchi , et al. (1 additional authors not shown)

    Abstract: Current $γ$-ray telescopes suffer from a gap in sensitivity in the energy range between 100keV and 100MeV, and no polarisation measurement has ever been done on cosmic sources above 1MeV. Past and present e$^+$e$^-$ pair telescopes are limited at lower energies by the multiple scattering of electrons in passive tungsten converter plates. This results in low angular resolution, and, consequently, a… ▽ More

    Submitted 30 June, 2016; originally announced June 2016.

    Comments: SPIE Astronomical telescopes and instrumentation conference 2016

  3. arXiv:1603.06817  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Measurement of 1.7 to 74 MeV polarised gamma rays with the HARPO TPC

    Authors: Y. Geerebaert, Ph. Gros, S. Amano, D. Attié, D. Bernard, P. Bruel, D. Calvet, P. Colas, S. Daté, A. Delbart, M. Frotin, B. Giebels, D. Götz, S. Hashimoto, D. Horan, T. Kotaka, M. Louzir, Y. Minamiyama, S. Miyamoto, H. Ohkuma, P. Poilleux, I. Semeniouk, P. Sizun, A. Takemoto, M. Yamaguchi , et al. (1 additional authors not shown)

    Abstract: Current γ-ray telescopes based on photon conversions to electron-positron pairs, such as Fermi, use tungsten converters. They suffer of limited angular resolution at low energies, and their sensitivity drops below 1 GeV. The low multiple scattering in a gaseous detector gives access to higher angular resolution in the MeV-GeV range, and to the linear polarisation of the photons through the azimuth… ▽ More

    Submitted 22 March, 2016; originally announced March 2016.

    Comments: Proceedings VCI2016

  4. arXiv:1503.03772  [pdf, other

    astro-ph.IM physics.ins-det

    HARPO: beam characterization of a TPC for gamma-ray polarimetry and high angular-resolution astronomy in the MeV-GeV range

    Authors: Shaobo Wang, Denis Bernard, Philippe Bruel, Mickael Frotin, Yannick Geerebaert, Berrie Giebels, Philippe Gros, Deirdre Horan, Marc Louzir, Patrick Poilleux, Igor Semeniouk, David Attié, Denis Calvet, Paul Colas, Alain Delbart, Patrick Sizun, Diego Götz, Sho Amano, Takuya Kotaka, Satoshi Hashimoto, Yasuhito Minamiyama, Akinori Takemoto, Masashi Yamaguchi, Shuji Miyamoto, Schin Daté , et al. (1 additional authors not shown)

    Abstract: A time projection chamber (TPC) can be used to measure the polarization of gamma rays with excellent angular precision and sensitivity in the MeV-GeV energy range through the conversion of photons to e+e- pairs. The Hermetic ARgon POlarimeter (HARPO) prototype was built to demonstrate this concept. It was recently tested in the polarized photon beam at the NewSUBARU facility in Japan. We present t… ▽ More

    Submitted 12 March, 2015; originally announced March 2015.

    Comments: 12 pages, 11 figures, presented at the 7th Symposium on large TPCs for low-energy rare event detection, Paris, France, 15-17 December 2014