Optimisation of energy and exergy of two-spool turbofan engines using genetic algorithms
Authors:
Vin Cent Tai,
Phen Chiak See,
Cristinel Mares,
Kjetil Uhlen
Abstract:
This paper presents an application of Genetic Algorithm (GA) metaheuristics to optimise the design of two-spool turbofan engines based on exergy and energy theories. The GA is used to seek the optimal values of eight parameters that define the turbofan engine. These parameters are encoded as chromosomes (a metaphor) in GA. A computer program called TurboJet-Engine Optimizer v1.0 (TJEO-1.0) was dev…
▽ More
This paper presents an application of Genetic Algorithm (GA) metaheuristics to optimise the design of two-spool turbofan engines based on exergy and energy theories. The GA is used to seek the optimal values of eight parameters that define the turbofan engine. These parameters are encoded as chromosomes (a metaphor) in GA. A computer program called TurboJet-Engine Optimizer v1.0 (TJEO-1.0) was developed by the authors to perform calculations of thermodynamic properties of the engine and implement the optimisations. The caloric properties of the working fluids are obtained by using an 8th-order polynomial fluid model taken from an existing literature. The turbo-mechanical components in the turbofan engine are as well assumed to exhibit polytropic efficiencies of today's technology level. The TJEO-1.0 is integrated with Pyevolve, an open source GA optimisation framework built for used with Python programming language. The optimal design created by TJEO-1.0 was evaluated with the following criteria: (1.) energy efficiency, (2.) exergy efficiency, and (3.) combination of both of them. The results suggest that the design of turbofan engine optimised based on the third criterion is able to produce higher specific thrust (by more than 30 %), compared with the ones optimised based on the first and the second criteria.
△ Less
Submitted 3 July, 2012;
originally announced July 2012.
-
Enhanced active power filter control for nonlinear non-stationary reactive power compensation
Authors:
Phen Chiak See,
Vin Cent Tai,
Marta Molinas,
Kjetil Uhlen,
Olav Bjarte Fosso
Abstract:
This paper describes a method to implement Reactive Power Compensation (RPC) in power systems that possess nonlinear non-stationary current disturbances. The Empirical Mode Decomposition (EMD) introduced in the Hilbert-Huang Transform (HHT) is used to separate the disturbances from the original current waveform. These disturbances are subsequently removed. Following that, Power Factor Correction (…
▽ More
This paper describes a method to implement Reactive Power Compensation (RPC) in power systems that possess nonlinear non-stationary current disturbances. The Empirical Mode Decomposition (EMD) introduced in the Hilbert-Huang Transform (HHT) is used to separate the disturbances from the original current waveform. These disturbances are subsequently removed. Following that, Power Factor Correction (PFC) based on the well-known p-q power theory is conducted to remove the reactive power. Both operations were implemented in a shunt Active Power Filter (APF). The EMD significantly simplifies the singulation and the removal of the current disturbances. This helps to effectively identify the fundamental current waveform. Hence, it simplifies the implementation of RPC on nonlinear non-stationary power systems.
△ Less
Submitted 19 June, 2012;
originally announced June 2012.
-
Performance assessment of two active power filter control strategies in the presence of non-stationary currents
Authors:
Vin Cent Tai,
Phen Chiak See,
Marta Molinas,
Kjetil Uhlen
Abstract:
This paper describes an active power filter (APF) control strategy, which eliminates harmonics and compensates reactive power in a three-phase four-wire power system supplying non-linear unbalanced loads in the presence of non-linear non-stationary currents. Empirical Mode Decomposition (EMD) technique developed as part of the Hilbert-Huang Transform (HHT) is used to singulate the harmonics and no…
▽ More
This paper describes an active power filter (APF) control strategy, which eliminates harmonics and compensates reactive power in a three-phase four-wire power system supplying non-linear unbalanced loads in the presence of non-linear non-stationary currents. Empirical Mode Decomposition (EMD) technique developed as part of the Hilbert-Huang Transform (HHT) is used to singulate the harmonics and non-linear non stationary disturbances from the load currents. The control strategy for the APF is formulated by hybridizing the so called modified p-q theory with the EMD algorithm. A four-leg split-capacitor converter controlled by hysteresis band current controller is used as an APF. The results obtained are compared with those obtained with the conventional modified p-q theory, which does not possess current harmonics or distortions separation strategy, to validate its performance.
△ Less
Submitted 7 June, 2012;
originally announced June 2012.