Reconstruction of 3-Axis Seismocardiogram from Right-to-left and Head-to-foot Components Using A Long Short-Term Memory Network
Authors:
Mohammad Muntasir Rahman,
Amirtahà Taebi
Abstract:
This pilot study aims to develop a deep learning model for predicting seismocardiogram (SCG) signals in the dorsoventral direction from the SCG signals in the right-to-left and head-to-foot directions ($\textrm{SCG}_x$ and $\textrm{SCG}_y$). The dataset used for the training and validation of the model was obtained from 15 healthy adult subjects. The SCG signals were recorded using tri-axial accel…
▽ More
This pilot study aims to develop a deep learning model for predicting seismocardiogram (SCG) signals in the dorsoventral direction from the SCG signals in the right-to-left and head-to-foot directions ($\textrm{SCG}_x$ and $\textrm{SCG}_y$). The dataset used for the training and validation of the model was obtained from 15 healthy adult subjects. The SCG signals were recorded using tri-axial accelerometers placed on the chest of each subject. The signals were then segmented using electrocardiogram R waves, and the segments were downsampled, normalized, and centered around zero. The resulting dataset was used to train and validate a long short-term memory (LSTM) network with two layers and a dropout layer to prevent overfitting. The network took as input 100-time steps of $\textrm{SCG}_x$ and $\textrm{SCG}_y$, representing one cardiac cycle, and outputted a vector that mapped to the target variable being predicted. The results showed that the LSTM model had a mean square error of 0.09 between the predicted and actual SCG segments in the dorsoventral direction. The study demonstrates the potential of deep learning models for reconstructing 3-axis SCG signals using the data obtained from dual-axis accelerometers.
△ Less
Submitted 2 December, 2023; v1 submitted 14 July, 2023;
originally announced July 2023.
-
Effect of Measurement Location on Cardiac Time Intervals Estimated by Seismocardiography
Authors:
Aysha Mann,
Bahram Kakavand,
Peshala Thibbotuwawa Gamage,
Amirtahà Taebi
Abstract:
Cardiac time intervals (CTIs) are important parameters for assessing cardiac function and can be measured using non-invasive methods such as electrocardiography (ECG) and seismocardiography (SCG). It is widely accepted that SCG signals, when measured from various locations on the chest surface, exhibit distinct temporal and spectral characteristics. In that regard, the goal of this study was to de…
▽ More
Cardiac time intervals (CTIs) are important parameters for assessing cardiac function and can be measured using non-invasive methods such as electrocardiography (ECG) and seismocardiography (SCG). It is widely accepted that SCG signals, when measured from various locations on the chest surface, exhibit distinct temporal and spectral characteristics. In that regard, the goal of this study was to determine the effect of the SCG measurement location on estimating SCG-based CTIs. For this purpose, ECG, SCG, and phonocardiography (PCG) signals were acquired from fourteen healthy adult subjects. For SCG, three tri-axial accelerometers were attached on the top, middle, and bottom of the sternum with double-sided tape. In this study, only the dorsoventral components of the SCG signals were analyzed. Using Pan-Tompkin's algorithm, ECG R peaks and their temporal indices were found. Then, a custom-built algorithm in MATLAB was developed to estimate heart rate (HR) from ECG and SCG signals. Furthermore, SCG fiducial points and CTIs were defined from the SCG signals recorded from different sternal locations. The average and correlation coefficient of the CTIs and HRs derived from all three locations were compared. Mean difference and standard deviation were analyzed for the CTIs and their respective sensor location. Results demonstrated that SCG-based CTIs varied with the SCG measurement locations. In conclusion, these results highlighted the importance of establishing consistent research and clinical protocols for reporting CTIs based on SCG. This work also calls for further investigation into comparing estimated CTIs with gold-standard methods such as echocardiography and 4D cardiac computed tomography.
△ Less
Submitted 13 June, 2023;
originally announced June 2023.
-
Seismocardiographic Signal Timing with Myocardial Strain
Authors:
Amirtaha Taebi,
Richard H. Sandler,
Bahram Kakavand,
Hansen A. Mansy
Abstract:
Speckle Tracking Echocardiography (STE) is a relatively new method for cardiac function evaluation. In the current study, STE was used to investigate the timing of heart-induced mostly subaudible (i.e., below the frequency limit of human hearing) chest-wall vibrations in relation to the longitudinal myocardial strain. Such an approach may help elucidate the genesis of these vibrations, thereby imp…
▽ More
Speckle Tracking Echocardiography (STE) is a relatively new method for cardiac function evaluation. In the current study, STE was used to investigate the timing of heart-induced mostly subaudible (i.e., below the frequency limit of human hearing) chest-wall vibrations in relation to the longitudinal myocardial strain. Such an approach may help elucidate the genesis of these vibrations, thereby improving their diagnostic value.
△ Less
Submitted 5 March, 2018;
originally announced April 2018.
-
Heart Rate Monitoring During Different Lung Volume Phases Using Seismocardiography
Authors:
Amirtaha Taebi,
Andrew J Bomar,
Richard H Sandler,
Hansen A Mansy
Abstract:
Seismocardiography (SCG) is a non-invasive method that can be used for cardiac activity monitoring. This paper presents a new electrocardiogram (ECG) independent approach for estimating heart rate (HR) during low and high lung volume (LLV and HLV, respectively) phases using SCG signals. In this study, SCG, ECG, and respiratory flow rate (RFR) signals were measured simultaneously in 7 healthy subje…
▽ More
Seismocardiography (SCG) is a non-invasive method that can be used for cardiac activity monitoring. This paper presents a new electrocardiogram (ECG) independent approach for estimating heart rate (HR) during low and high lung volume (LLV and HLV, respectively) phases using SCG signals. In this study, SCG, ECG, and respiratory flow rate (RFR) signals were measured simultaneously in 7 healthy subjects. The lung volume information was calculated from the RFR and was used to group the SCG events into low and high lung-volume groups. LLV and HLV SCG events were then used to estimate the subjects HR as well as the HR during LLV and HLV in 3 different postural positions, namely supine, 45 degree heads-up, and sitting. The performance of the proposed algorithm was tested against the standard ECG measurements. Results showed that the HR estimations from the SCG and ECG signals were in a good agreement (bias of 0.08 bpm). All subjects were found to have a higher HR during HLV (HR$_\text{HLV}$) compared to LLV (HR$_\text{LLV}$) at all postural positions. The HR$_\text{HLV}$/HR$_\text{LLV}$ ratio was 1.11$\pm$0.07, 1.08$\pm$0.05, 1.09$\pm$0.04, and 1.09$\pm$0.04 (mean$\pm$SD) for supine, 45 degree-first trial, 45 degree-second trial, and sitting positions, respectively. This heart rate variability may be due, at least in part, to the well-known respiratory sinus arrhythmia. HR monitoring from SCG signals might be used in different clinical applications including wearable cardiac monitoring systems.
△ Less
Submitted 7 May, 2018; v1 submitted 27 March, 2018;
originally announced March 2018.
-
An Adaptive Feature Extraction Algorithm for Classification of Seismocardiographic Signals
Authors:
Amirtaha Taebi,
Brian E Solar,
Hansen A Mansy
Abstract:
This paper proposes a novel adaptive feature extraction algorithm for seismocardiographic (SCG) signals. The proposed algorithm divides the SCG signal into a number of bins, where the length of each bin is determined based on the signal change within that bin. For example, when the signal variation is steeper, the bins are shorter and vice versa. The proposed algorithm was used to extract features…
▽ More
This paper proposes a novel adaptive feature extraction algorithm for seismocardiographic (SCG) signals. The proposed algorithm divides the SCG signal into a number of bins, where the length of each bin is determined based on the signal change within that bin. For example, when the signal variation is steeper, the bins are shorter and vice versa. The proposed algorithm was used to extract features of the SCG signals recorded from 7 healthy individuals (Age: 29.4$\pm$4.5 years) during different lung volume phases. The output of the feature extraction algorithm was fed into a support vector machines classifier to classify SCG events into two classes of high and low lung volume (HLV and LLV). The classification results were compared with currently available non-adaptive feature extraction methods for different number of bins. Results showed that the proposed algorithm led to a classification accuracy of ~90%. The proposed algorithm outperformed the non-adaptive algorithm, especially as the number of bins was reduced. For example, for 16 bins, F1 score for the adaptive and non-adaptive methods were 0.91$\pm$0.05 and 0.63$\pm$0.08, respectively.
△ Less
Submitted 7 May, 2018; v1 submitted 27 March, 2018;
originally announced March 2018.
-
Grou** Similar Seismocardiographic Signals Using Respiratory Information
Authors:
Amirtaha Taebi,
Hansen A Mansy
Abstract:
Seismocardiography (SCG) offers a potential non-invasive method for cardiac monitoring. Quantification of the effects of different physiological conditions on SCG can lead to enhanced understanding of SCG genesis, and may explain how some cardiac pathologies may affect SCG morphology. In this study, the effect of the respiration on the SCG signal morphology is investigated. SCG, ECG, and respirato…
▽ More
Seismocardiography (SCG) offers a potential non-invasive method for cardiac monitoring. Quantification of the effects of different physiological conditions on SCG can lead to enhanced understanding of SCG genesis, and may explain how some cardiac pathologies may affect SCG morphology. In this study, the effect of the respiration on the SCG signal morphology is investigated. SCG, ECG, and respiratory flow rate signals were measured simultaneously in 7 healthy subjects. Results showed that SCG events tended to have two slightly different morphologies. The respiratory flow rate and lung volume information were used to group the SCG events into inspiratory/expiratory groups or low/high lung-volume groups, respectively. Although respiratory flow information could separate similar SCG events into two different groups, the lung volume information provided better grou** of similar SCGs. This suggests that variations in SCG morphology may be due, at least in part, to changes in the intrathoracic pressure or heart location since those parameters correlates more with lung volume than respiratory flow. Categorizing SCG events into different groups containing similar events allows more accurate estimation of SCG features, and better signal characterization, and classification.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
Analysis of Seismocardiographic Signals Using Polynomial Chirplet Transform and Smoothed Pseudo Wigner-Ville Distribution
Authors:
Amirtaha Taebi,
Hansen A Mansy
Abstract:
Seismocardiographic (SCG) signals are chest surface vibrations induced by cardiac activity. These signals may offer a method for diagnosing and monitoring heart function. Successful classification of SCG signals in health and disease depends on accurate signal characterization and feature extraction. One approach of determining signal features is to estimate its time-frequency characteristics. In…
▽ More
Seismocardiographic (SCG) signals are chest surface vibrations induced by cardiac activity. These signals may offer a method for diagnosing and monitoring heart function. Successful classification of SCG signals in health and disease depends on accurate signal characterization and feature extraction. One approach of determining signal features is to estimate its time-frequency characteristics. In this regard, four different time-frequency distribution (TFD) approaches were used including short-time Fourier transform (STFT), polynomial chirplet transform (PCT), Wigner-Ville distribution (WVD), and smoothed pseudo Wigner-Ville distribution (SPWVD). Synthetic SCG signals with known time-frequency properties were generated and used to evaluate the accuracy of the different TFDs in extracting SCG spectral characteristics. Using different TFDs, the instantaneous frequency (IF) of each synthetic signal was determined and the error (NRMSE) in estimating IF was calculated. STFT had lower NRMSE than WVD for synthetic signals considered. PCT and SPWVD were, however, more accurate IF estimators especially for the signal with time-varying frequencies. PCT and SPWVD also provided better discrimination between signal frequency components. Therefore, the results of this study suggest that PCT and SPWVD would be more reliable methods for estimating IF of SCG signals. Analysis of actual SCG signals showed that these signals had multiple spectral components with slightly time-varying frequencies. More studies are needed to investigate SCG spectral properties for healthy subjects as well as patients with different cardiac conditions.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.
-
Pressure Loss and Sound Generated In a Miniature Pig Airway Tree Model
Authors:
Md Khurshidul Azad,
Amirtaha Taebi,
Joseph H Mansy,
HA Mansy
Abstract:
Background: Pulmonary auscultation is a common tool for diagnosing various respiratory diseases. Previous studies have documented many details of pulmonary sounds in humans. However, information on sound generation and pressure loss inside animal airways is scarce. Since the morphology of animal airways can be significantly different from human, the characteristics of pulmonary sounds and pressure…
▽ More
Background: Pulmonary auscultation is a common tool for diagnosing various respiratory diseases. Previous studies have documented many details of pulmonary sounds in humans. However, information on sound generation and pressure loss inside animal airways is scarce. Since the morphology of animal airways can be significantly different from human, the characteristics of pulmonary sounds and pressure loss inside animal airways can be different. Objective: The objective of this study is to investigate the sound and static pressure loss measured at the trachea of a miniature pig airway tree model based on the geometric details extracted from physical measurements. Methods: In the current study, static pressure loss and sound generation measured in the trachea was documented at different flow rates of a miniature pig airway tree. Results: Results showed that the static pressure and the amplitude of the recorded sound at the trachea increased as the flow rate increased. The dominant frequency was found to be around 1840-1870 Hz for flow rates of 0.2-0.55 lit/s. Conclusion: The results suggested that the dominant frequency of the measured sounds remained similar for flow rates from 0.20 to 0.55 lit/s. Further investigation is needed to study sound generation under different inlet flow and pulsatile flow conditions.
△ Less
Submitted 29 November, 2017;
originally announced November 2017.