Showing 1–3 of 3 results for author: Szarmes, E B
-
Temporal synchronization of GHz repetition rate electron and laser pulses for the optimization of a compact inverse-Compton scattering x-ray source
Authors:
Michael R. Hadmack,
Eric B. Szarmes,
John M. J. Madey,
Jeremy M. D. Kowalczyk
Abstract:
The operation of an inverse-Compton scattering source of x-rays or gamma-rays requires the precision alignment and synchronization of highly focused electron bunches and laser pulses at the collision point. The arrival times of electron and laser pulses must be synchronized with picosecond precision. We have developed an RF synchronization technique that reduces the initial timing uncertainty from…
▽ More
The operation of an inverse-Compton scattering source of x-rays or gamma-rays requires the precision alignment and synchronization of highly focused electron bunches and laser pulses at the collision point. The arrival times of electron and laser pulses must be synchronized with picosecond precision. We have developed an RF synchronization technique that reduces the initial timing uncertainty from 350 ps to less than 2 ps, greatly reducing the parameter space to be optimized while commissioning the x-ray source. We describe the technique and present measurements of its performance.
△ Less
Submitted 23 April, 2014;
originally announced April 2014.
-
Scanning wire beam position monitor for alignment of a high brightness inverse-Compton x-ray source
Authors:
Michael R. Hadmack,
Eric B. Szarmes
Abstract:
The Free-Electron Laser Laboratory at the University of Hawai`i has constructed and tested a scanning wire beam position monitor to aid the alignment and optimization of a high spectral brightness inverse-Compton scattering x-ray source. X-rays are produced by colliding the 40 MeV electron beam from a pulsed S-band linac with infrared laser pulses from a mode-locked free-electron laser driven by t…
▽ More
The Free-Electron Laser Laboratory at the University of Hawai`i has constructed and tested a scanning wire beam position monitor to aid the alignment and optimization of a high spectral brightness inverse-Compton scattering x-ray source. X-rays are produced by colliding the 40 MeV electron beam from a pulsed S-band linac with infrared laser pulses from a mode-locked free-electron laser driven by the same electron beam. The electron and laser beams are focused to 60 μm diameters at the interaction point to achieve high scattering efficiency. This wire-scanner allows for high resolution measurements of the size and position of both the laser and electron beams at the interaction point to verify spatial coincidence. Time resolved measurements of secondary emission current allow us to monitor the transverse spatial evolution of the e-beam throughout the duration of a 4 μs macro-pulse while the laser is simultaneously profiled by pyrometer measurement of the occulted infrared beam. Using this apparatus we have demonstrated that the electron and laser beams can be co-aligned with a precision better than 10 μm as required to maximize x-ray yield.
△ Less
Submitted 21 November, 2013;
originally announced November 2013.
-
Electron bunch energy and phase feed-forward stabilization system for the Mark V RF-linac free-electron laser
Authors:
M. R. Hadmack,
B. T. Jacobson,
J. M. D. Kowalczyk,
B. R. Lienert,
J. M. J. Madey,
E. B. Szarmes
Abstract:
An amplitude and phase compensation system has been developed and tested at the University of Hawai`i for the optimization of the RF drive system to the Mark V Free-Electron Laser. Temporal uniformity of the RF drive is essential to the generation of an electron beam suitable for optimal free-electron laser performance and the operation of an inverse Compton scattering x-ray source. The design of…
▽ More
An amplitude and phase compensation system has been developed and tested at the University of Hawai`i for the optimization of the RF drive system to the Mark V Free-Electron Laser. Temporal uniformity of the RF drive is essential to the generation of an electron beam suitable for optimal free-electron laser performance and the operation of an inverse Compton scattering x-ray source. The design of the RF measurement and compensation system is described in detail and the results of RF phase compensation are presented. Performance of the free-electron laser was evaluated by comparing the measured effects of phase compensation with the results of a computer simulation. Finally, preliminary results are presented for the effects of amplitude compensation on the performance of the complete system.
△ Less
Submitted 28 June, 2013;
originally announced July 2013.