-
Quantum-limited optical time transfer for future geosynchronous links
Authors:
Emily D. Caldwell,
Jean-Daniel Deschenes,
Jennifer Ellis,
William C. Swann,
Benjamin K. Stuhl,
Hugo Bergeron,
Nathan R. Newbury,
Laura C. Sinclair
Abstract:
The combination of optical time transfer and optical clocks opens up the possibility of large-scale free-space networks that connect both ground-based optical clocks and future space-based optical clocks. Such networks promise better tests of general relativity, dark matter searches, and gravitational wave detection. The ability to connect optical clocks to a distant satellite could enable space-b…
▽ More
The combination of optical time transfer and optical clocks opens up the possibility of large-scale free-space networks that connect both ground-based optical clocks and future space-based optical clocks. Such networks promise better tests of general relativity, dark matter searches, and gravitational wave detection. The ability to connect optical clocks to a distant satellite could enable space-based very long baseline interferometry (VLBI), advanced satellite navigation, clock-based geodesy, and thousand-fold improvements in intercontinental time dissemination. Thus far, only optical clocks have pushed towards quantum-limited performance. In contrast, optical time transfer has not operated at the analogous quantum limit set by the number of received photons. Here, we demonstrate time transfer with near quantum-limited acquisition and timing at 10,000 times lower received power than previous approaches. Over 300 km between mountaintops in Hawaii with launched powers as low as 40 $μ$W, distant timescales are synchronized to 320 attoseconds. This nearly quantum-limited operation is critical for long-distance free-space links where photons are few and amplification costly -- at 4.0 mW transmit power, this approach can support 102 dB link loss, more than sufficient for future time transfer to geosynchronous orbits.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Optical Atomic Clock Comparison through Turbulent Air
Authors:
Martha I. Bodine,
Jean-Daniel Deschênes,
Isaac H. Khader,
William C. Swann,
Holly Leopardi,
Kyle Beloy,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Amanda Koepke,
David R. Leibrandt,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Daniele Nicolodi,
Eric Oelker,
Thomas E. Parker
, et al. (10 additional authors not shown)
Abstract:
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the fr…
▽ More
We use frequency comb-based optical two-way time-frequency transfer (O-TWTFT) to measure the optical frequency ratio of state-of-the-art ytterbium and strontium optical atomic clocks separated by a 1.5 km open-air link. Our free-space measurement is compared to a simultaneous measurement acquired via a noise-cancelled fiber link. Despite non-stationary, ps-level time-of-flight variations in the free-space link, ratio measurements obtained from the two links, averaged over 30.5 hours across six days, agree to $6\times10^{-19}$, showing that O-TWTFT can support free-space atomic clock comparisons below the $10^{-18}$ level.
△ Less
Submitted 11 September, 2020; v1 submitted 1 June, 2020;
originally announced June 2020.
-
Frequency Ratio Measurements with 18-digit Accuracy Using a Network of Optical Clocks
Authors:
Boulder Atomic Clock Optical Network,
Collaboration,
:,
Kyle Beloy,
Martha I. Bodine,
Tobias Bothwell,
Samuel M. Brewer,
Sarah L. Bromley,
Jwo-Sy Chen,
Jean-Daniel Deschênes,
Scott A. Diddams,
Robert J. Fasano,
Tara M. Fortier,
Youssef S. Hassan,
David B. Hume,
Dhruv Kedar,
Colin J. Kennedy,
Isaac Khader,
Amanda Koepke,
David R. Leibrandt,
Holly Leopardi,
Andrew D. Ludlow,
William F. McGrew,
William R. Milner,
Nathan R. Newbury
, et al. (13 additional authors not shown)
Abstract:
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al…
▽ More
Atomic clocks occupy a unique position in measurement science, exhibiting higher accuracy than any other measurement standard and underpinning six out of seven base units in the SI system. By exploiting higher resonance frequencies, optical atomic clocks now achieve greater stability and lower frequency uncertainty than existing primary standards. Here, we report frequency ratios of the $^{27}$Al$^+$, $^{171}$Yb and $^{87}$Sr optical clocks in Boulder, Colorado, measured across an optical network spanned by both fiber and free-space links. These ratios have been evaluated with measurement uncertainties between $6\times10^{-18}$ and $8\times10^{-18}$, making them the most accurate reported measurements of frequency ratios to date. This represents a critical step towards redefinition of the SI second and future applications such as relativistic geodesy and tests of fundamental physics.
△ Less
Submitted 29 May, 2020;
originally announced May 2020.
-
Measurement of the impact of turbulence anisoplanatism on precision free-space optical time transfer
Authors:
W. C. Swann,
M. I. Bodine,
I. Khader,
J. -D. Deschenes,
E. Baumann,
L. C. Sinclair,
N. R. Newbury
Abstract:
Future free-space optical clock networks will require optical links for time and frequency transfer. In many potential realizations of these networks, these links will extend over long distances and will span moving platforms, e.g. ground-to-air or ground-to-satellite. In these cases, the transverse platform motion coupled with spatial variations in atmospheric optical turbulence will lead to a br…
▽ More
Future free-space optical clock networks will require optical links for time and frequency transfer. In many potential realizations of these networks, these links will extend over long distances and will span moving platforms, e.g. ground-to-air or ground-to-satellite. In these cases, the transverse platform motion coupled with spatial variations in atmospheric optical turbulence will lead to a breakdown in the time-of-flight reciprocity upon which optical two-way time-frequency transfer is based. Here, we report experimental measurements of this effect by use of comb-based optical two-way time-frequency transfer over two spatially separated optical links. We find only a modest degradation in the time synchronization and frequency syntonization between two sites, in good agreement with theory. Based on this agreement, we can extrapolate this 2-km result to longer distances, finding only a few-femtosecond timing noise increase due to turbulence for a link from ground to a mid-earth orbit satellite.
△ Less
Submitted 12 October, 2018;
originally announced November 2018.
-
Femtosecond Synchronization of Optical Clocks Off of a Flying Quadcopter
Authors:
Hugo Bergeron,
Laura C. Sinclair,
William C. Swann,
Isaac Khader,
Kevin C. Cossel,
Michael Cermak,
Jean-Daniel Deschênes,
Nathan R. Newbury
Abstract:
Future optical clock networks will require free-space optical time-frequency transfer between flying clocks. However, simple one-way or standard two-way time transfer between flying clocks will completely break down because of the time-of-flight variations and Doppler shifts associated with the strongly time-varying optical link distances. Here, we demonstrate an advanced, comb-based optical two-w…
▽ More
Future optical clock networks will require free-space optical time-frequency transfer between flying clocks. However, simple one-way or standard two-way time transfer between flying clocks will completely break down because of the time-of-flight variations and Doppler shifts associated with the strongly time-varying optical link distances. Here, we demonstrate an advanced, comb-based optical two-way time-frequency transfer that can successfully synchronize the optical timescales at two sites connected via a time-varying turbulent air path. The link between the two sites is established using either a quadcopter-mounted retroreflector or a swept delay line at speeds up to 24 m/s. Despite 50-ps breakdown in time-of-flight reciprocity, the sites' timescales are synchronized to < 1 fs in time deviation. The corresponding sites' frequencies agree to $\sim$ $10^{-18}$ despite $10^{-7}$ Doppler shifts. This work demonstrates comb-based O-TWTFT can enable free-space optical networks between airborne or satellite-borne optical clocks for precision navigation, timing and probes of fundamental science.
△ Less
Submitted 20 December, 2018; v1 submitted 22 August, 2018;
originally announced August 2018.
-
Femtosecond Optical Two-Way Time-Frequency Transfer in the Presence of Motion
Authors:
Laura C. Sinclair,
Hugo Bergeron,
William C. Swann,
Isaac Khader,
Kevin C. Cossel,
Michael Cermak,
Nathan R. Newbury,
Jean-Daniel Deschênes
Abstract:
Platform motion poses significant challenges to high-precision optical time and frequency transfer. We give a detailed description of these challenges and their solutions in comb-based optical two-way time and frequency transfer (O-TWTFT). Specifically, we discuss the breakdown in reciprocity due to relativity and due to asynchronous sampling, the impact of optical and electrical dispersion, and v…
▽ More
Platform motion poses significant challenges to high-precision optical time and frequency transfer. We give a detailed description of these challenges and their solutions in comb-based optical two-way time and frequency transfer (O-TWTFT). Specifically, we discuss the breakdown in reciprocity due to relativity and due to asynchronous sampling, the impact of optical and electrical dispersion, and velocity-dependent transceiver calibration. We present a detailed derivation of the equations governing comb-based O-TWTFT in the presence of motion. We describe the implementation of real-time signal processing algorithms based on these equations and demonstrate active synchronization of two sites over turbulent air paths to below a femtosecond time deviation despite effective velocities of +/-25 m/s, which is the maximum achievable with our physical setup. With the implementation of the time transfer equation derived here, we find no velocity-dependent bias between the synchronized clocks to within at two-sigma statistical uncertainty of 330 attoseconds.
△ Less
Submitted 21 August, 2018;
originally announced August 2018.
-
Time Synchronization over a Free-Space Optical Communication Channel
Authors:
Isaac Khader,
Hugo Bergeron,
Laura C. Sinclair,
William C. Swann,
Nathan R. Newbury,
Jean-Daniel Deschênes
Abstract:
Free space optical (FSO) communication channels are typically used to transmit high-speed data between sites over the air. Here we repurpose an FSO digital communication system and use it directly for two-way time transfer. We demonstrate real-time synchronization between two sites over a turbulent air path of 4 km using binary phase modulated CW laser light. Under synchronization, the two sites e…
▽ More
Free space optical (FSO) communication channels are typically used to transmit high-speed data between sites over the air. Here we repurpose an FSO digital communication system and use it directly for two-way time transfer. We demonstrate real-time synchronization between two sites over a turbulent air path of 4 km using binary phase modulated CW laser light. Under synchronization, the two sites exhibit a fractional frequency deviation below $10^{-15}$ and a time deviation below 1 picosecond at averaging times of seconds to hours. Over an 8-hour period the peak to peak wander is 16 ps.
△ Less
Submitted 20 August, 2018;
originally announced August 2018.
-
Comparing optical oscillators across the air to milliradians in phase and $10^{-17}$ in frequency
Authors:
Laura C. Sinclair,
Hugo Bergeron,
William C. Swann,
Esther Baumann,
Jean-Daniel Deschênes,
Nathan R. Newbury
Abstract:
We demonstrate carrier-phase optical two-way time-frequency transfer (carrier-phase OTWTFT) through the two-way exchange of frequency comb pulses. Carrier-phase OTWTFT achieves frequency comparisons with a residual instability of 1.2x10$^{-17}$ at 1 second across a turbulent 4-km free space link, surpassing previous OTWTFT by 10-20x and enabling future high-precision optical clock networks. Furthe…
▽ More
We demonstrate carrier-phase optical two-way time-frequency transfer (carrier-phase OTWTFT) through the two-way exchange of frequency comb pulses. Carrier-phase OTWTFT achieves frequency comparisons with a residual instability of 1.2x10$^{-17}$ at 1 second across a turbulent 4-km free space link, surpassing previous OTWTFT by 10-20x and enabling future high-precision optical clock networks. Furthermore, by exploiting the carrier-phase, this approach is able to continuously track changes in the relative optical phase of distant optical oscillators to 9 mrad (7 attoseconds) at 1-sec averaging, effectively extending optical phase coherence over a broad spatial network for applications such as correlated spectroscopy between distant atomic clocks.
△ Less
Submitted 10 October, 2017;
originally announced October 2017.
-
Accurate frequency referencing for fieldable dual-comb spectroscopy
Authors:
Gar-Wing Truong,
Eleanor M. Waxman,
Kevin C. Cossel,
Esther Baumann,
Andrew Klose,
Fabrizio R. Giorgetta,
William C. Swann,
Nathan R. Newbury,
Ian Coddington
Abstract:
A fieldable dual-comb spectrometer is described based on a "bootstrapped" frequency referencing scheme in which short-term optical phase coherence between combs is attained by referencing each to a free-running diode laser, whilst high frequency resolution and long-term accuracy is derived from a stable quartz oscillator. This fieldable dual-comb spectrometer was used to measure spectra with full…
▽ More
A fieldable dual-comb spectrometer is described based on a "bootstrapped" frequency referencing scheme in which short-term optical phase coherence between combs is attained by referencing each to a free-running diode laser, whilst high frequency resolution and long-term accuracy is derived from a stable quartz oscillator. This fieldable dual-comb spectrometer was used to measure spectra with full comb-tooth resolution spanning from 140 THz (2.14 um, 4670 cm^-1) to 184 THz (1.63 um, 6140 cm^-1) in the near infrared with a frequency sampling of 200 MHz (0.0067 cm^-1), ~ 120 kHz frequency resolution, and ~ 1 MHz frequency accuracy. High resolution spectra of water and carbon dioxide transitions at 1.77 um, 1.96 um and 2.06 um show that the molecular transmission acquired with this fieldable system did not deviate from those measured with a laboratory-based system (referenced to a maser and cavity-stabilized laser) to within 5.6x10^-4. Additionally, the fieldable system optimized for carbon dioxide quantification at 1.60 um, demonstrated a sensitivity of 2.8 ppm-km at 1 s integration time, improving to 0.10 ppm-km at 13 minutes of integration time.
△ Less
Submitted 30 November, 2016;
originally announced December 2016.
-
Synchronization of Distant Optical Clocks at the Femtosecond Level
Authors:
Jean-Daniel Deschenes,
Laura C. Sinclair,
Fabrizio R. Giorgetta,
William C. Swann,
Esther Baumann,
Hugo Bergeron,
Michael Cermak,
Ian Coddington,
Nathan R. Newbury
Abstract:
The use of optical clocks/oscillators in future ultra-precise navigation, gravitational sensing, coherent arrays, and relativity experiments will require time comparison and synchronization over terrestrial or satellite free-space links. Here we demonstrate full unambiguous synchronization of two optical timescales across a free-space link. The time deviation between synchronized timescales is bel…
▽ More
The use of optical clocks/oscillators in future ultra-precise navigation, gravitational sensing, coherent arrays, and relativity experiments will require time comparison and synchronization over terrestrial or satellite free-space links. Here we demonstrate full unambiguous synchronization of two optical timescales across a free-space link. The time deviation between synchronized timescales is below 1 fs over durations from 0.1 s to 6500 s, despite atmospheric turbulence and kilometer-scale path length variations. Over several days, the time wander is 40 fs peak-to-peak. Our approach relies on the two-way reciprocity of a single-spatial-mode optical link, valid to below 225 attoseconds across a turbulent 4-km path. This femtosecond level of time-frequency transfer should enable optical networks using state-of-the-art optical clocks/oscillators.
△ Less
Submitted 11 December, 2015; v1 submitted 25 September, 2015;
originally announced September 2015.
-
Frequency Comb-Based Remote Sensing of Greenhouse Gases over Kilometer Air Paths
Authors:
Gregory B. Rieker,
Fabrizio R. Giorgetta,
William C. Swann,
Jon Kofler,
Alex M. Zolot,
Laura C. Sinclair,
Esther Baumann,
Christopher Cromer,
Gabrielle Petron,
Colm Sweeney,
Pieter P. Tans,
Ian Coddington,
Nathan R. Newbury
Abstract:
We demonstrate coherent dual frequency-comb spectroscopy for detecting variations in greenhouse gases. High signal-to-noise spectra are acquired spanning 5990 to 6260 cm^-1 (1600 to 1670 nm) covering ~700 absorption features from CO2, CH4, H2O, HDO, and 13CO2, across a 2-km open-air path. The transmission of each frequency comb tooth is resolved, leading to spectra with <1 kHz frequency accuracy,…
▽ More
We demonstrate coherent dual frequency-comb spectroscopy for detecting variations in greenhouse gases. High signal-to-noise spectra are acquired spanning 5990 to 6260 cm^-1 (1600 to 1670 nm) covering ~700 absorption features from CO2, CH4, H2O, HDO, and 13CO2, across a 2-km open-air path. The transmission of each frequency comb tooth is resolved, leading to spectra with <1 kHz frequency accuracy, no instrument lineshape, and a 0.0033-cm^-1 point spacing. The fitted path-averaged concentrations and temperature yield dry-air mole fractions. These are compared with a point sensor under well-mixed conditions to evaluate current absorption models for real atmospheres. In heterogeneous conditions, time-resolved data demonstrate tracking of strong variations in mole fractions. A precision of <1 ppm for CO2 and <3 ppb for CH4 is achieved in 5 minutes in this initial demonstration. Future portable systems could support regional emissions monitoring and validation of the spectral databases critical to global satellite-based trace gas monitoring.
△ Less
Submitted 12 June, 2014;
originally announced June 2014.
-
Operation of an optically coherent frequency comb outside the metrology lab
Authors:
Laura C. Sinclair,
Ian Coddington,
William C. Swann,
Greg B. Rieker,
Archita Hati,
Kana Iwakuni,
Nathan R. Newbury
Abstract:
We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of < 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an optical reference. This fully phase-locked frequency comb has been successfully operated in a moving ve…
▽ More
We demonstrate a self-referenced fiber frequency comb that can operate outside the well-controlled optical laboratory. The frequency comb has residual optical linewidths of < 1 Hz, sub-radian residual optical phase noise, and residual pulse-to-pulse timing jitter of 2.4 - 5 fs, when locked to an optical reference. This fully phase-locked frequency comb has been successfully operated in a moving vehicle with 0.5 g peak accelerations and on a shaker table with a sustained 0.5 g rms integrated acceleration, while retaining its optical coherence and 5-fs-level timing jitter. This frequency comb should enable metrological measurements outside the laboratory with the precision and accuracy that are the hallmarks of comb-based systems. Work of the U.S. government, not subject to copyright
△ Less
Submitted 20 December, 2013;
originally announced December 2013.
-
Optical two-way time and frequency transfer over free space
Authors:
Fabrizio R. Giorgetta,
William C. Swann,
Laura C. Sinclair,
Esther Baumann,
Ian Coddington,
Nathan R. Newbury
Abstract:
The transfer of high-quality time-frequency signals between remote locations underpins a broad range of applications including precision navigation and timing, the new field of clock-based geodesy, long-baseline interferometry, coherent radar arrays, tests of general relativity and fundamental constants, and the future redefinition of the second [1-7]. However, present microwave-based time-frequen…
▽ More
The transfer of high-quality time-frequency signals between remote locations underpins a broad range of applications including precision navigation and timing, the new field of clock-based geodesy, long-baseline interferometry, coherent radar arrays, tests of general relativity and fundamental constants, and the future redefinition of the second [1-7]. However, present microwave-based time-frequency transfer [8-10] is inadequate for state-of-the-art optical clocks and oscillators [1,11-15] that have femtosecond-level timing jitter and accuracies below 1E-17; as such, commensurate optically-based transfer methods are needed. While fiber-based optical links have proven suitable [16,17], they are limited to comparisons between fixed sites connected by a specialized bidirectional fiber link. With the exception of tests of the fundamental constants, most applications instead require more flexible connections between remote and possibly portable optical clocks and oscillators. Here we demonstrate optical time-frequency transfer over free-space via a two-way exchange between coherent frequency combs, each phase-locked to the local optical clock or oscillator. We achieve femtosecond-scale timing deviation, a residual instability below 1E-18 at 1000 s and systematic offsets below 4E-19, despite frequent signal fading due to atmospheric turbulence or obstructions across the 2-km link. This free-space transfer would already enable terrestrial links to support clock-based geodesy. If combined with satellite-based free-space optical communications, it provides a path toward global-scale geodesy, high-accuracy time-frequency distribution, satellite-based relativity experiments, and "optical GPS" for precision navigation.
△ Less
Submitted 20 November, 2012;
originally announced November 2012.
-
Spectroscopy of the Methane ν3 Band with an Accurate Mid-Infrared Coherent Dual- Comb Spectrometer
Authors:
E. Baumann,
F. R. Giorgetta,
W. C. Swann,
A. M. Zolot,
I. Coddington,
N. R. Newbury
Abstract:
We demonstrate a high-accuracy dual-comb spectrometer centered at 3.4 μm. The amplitude and phase spectra of the P, Q, and partial R-branch of the methane ν3 band are measured at 25 MHz to 100 MHz point spacing with ~kHz resolution and a signal-to-noise ratio of up to 3500. A fit of the absorbance and phase spectra yield the center frequency of 132 rovibrational lines. The systematic uncertainty i…
▽ More
We demonstrate a high-accuracy dual-comb spectrometer centered at 3.4 μm. The amplitude and phase spectra of the P, Q, and partial R-branch of the methane ν3 band are measured at 25 MHz to 100 MHz point spacing with ~kHz resolution and a signal-to-noise ratio of up to 3500. A fit of the absorbance and phase spectra yield the center frequency of 132 rovibrational lines. The systematic uncertainty is estimated to be 300 kHz, which is 10-3 of the Doppler width and a tenfold improvement over Fourier transform spectroscopy. These data are the first high- accuracy molecular spectra obtained with a direct comb spectrometer.
△ Less
Submitted 6 October, 2011;
originally announced October 2011.
-
Coherent Dual Comb Spectroscopy at High Signal to Noise
Authors:
I. Coddington,
W. C. Swann,
N. R. Newbury
Abstract:
Two frequency combs can be used to measure the full complex response of a sample in a configuration which can be alternatively viewed as the equivalent of a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual comb spectrometer retains the frequency accuracy and resolution inherent to the comb sources. We discuss, in detai…
▽ More
Two frequency combs can be used to measure the full complex response of a sample in a configuration which can be alternatively viewed as the equivalent of a dispersive Fourier transform spectrometer, infrared time domain spectrometer, or a multiheterodyne laser spectrometer. This dual comb spectrometer retains the frequency accuracy and resolution inherent to the comb sources. We discuss, in detail, the specific design of our coherent dual-comb spectrometer and demonstrate the potential of this technique by measuring the first overtone vibration of hydrogen cyanide, centered at 194 THz (1545 nm). We measure the fully normalized, complex response of the gas over a 9 THz bandwidth at 220 MHz frequency resolution yielding 41,000 resolution elements. The average spectral signal-to-noise ratio (SNR) is 2,500 for both the fractional absorption and the phase, with a peak SNR of 4,000 corresponding to a fractional absorption sensitivity of 0.025% and phase sensitivity of 250 microradians. As the spectral coverage of combs expands, this dual-comb spectroscopy could provide high frequency accuracy and resolution measurements of a complex sample response across a range of spectral regions.
△ Less
Submitted 10 September, 2010; v1 submitted 21 January, 2010;
originally announced January 2010.
-
Coherent, multi-heterodyne spectroscopy using stabilized optical frequency combs
Authors:
Ian Coddington,
William C. Swann,
Nathan R. Newbury
Abstract:
The broadband, coherent nature of narrow-linewidth fiber frequency combs is exploited to measure the full complex spectrum of a molecular gas through multi-heterodyne spectroscopy. We measure the absorption and phase shift experienced by each of 155,000 individual frequency comb lines, spaced by 100 MHz and spanning from 1495 nm to 1620 nm, after passing through a hydrogen cyanide gas. The measu…
▽ More
The broadband, coherent nature of narrow-linewidth fiber frequency combs is exploited to measure the full complex spectrum of a molecular gas through multi-heterodyne spectroscopy. We measure the absorption and phase shift experienced by each of 155,000 individual frequency comb lines, spaced by 100 MHz and spanning from 1495 nm to 1620 nm, after passing through a hydrogen cyanide gas. The measured phase spectrum agrees with Kramers-Kronig transformation of the absorption spectrum. This technique can provide a full complex spectrum rapidly, over wide bandwidths, and with hertz-level accuracy.
△ Less
Submitted 17 October, 2007;
originally announced October 2007.