-
Micromechanical Experimental and Numerical Studies of Collagen Fibers Failure in Arterial Tissue
Authors:
Xiaochang Leng,
Yingchao Yang,
Xiaomin Deng,
Susan M. Lessner,
Michael A. Sutton,
Tarek Shazly
Abstract:
Arterial tissue failures lead to a number of clinical conditions that develop rapidly and unpredictably in vivo. Structural components and their interfacial mechanical strength of arterial tissue play a critical role in the process of arterail delamination. Therefore, there is a pressing need to understand the micromechanical mechanisms of arterial delamination. The objective of this study was to…
▽ More
Arterial tissue failures lead to a number of clinical conditions that develop rapidly and unpredictably in vivo. Structural components and their interfacial mechanical strength of arterial tissue play a critical role in the process of arterail delamination. Therefore, there is a pressing need to understand the micromechanical mechanisms of arterial delamination. The objective of this study was to investigate various failure mechanisms (e.g. failure of collagen fibers) responsible for arterial interfacial delamination. In-situ tensile tests of fibers were performed on a micro-tester in the scanning electron microscope. A 3D unit cell model containing an individual fiber bridging two arterial tissue layers was constructed. An exponential cohesive zone model (CZM) was used to assess the stiffening and softening mechanical behaviors of collagen fiber bundles between the two arterial layers. An anisotropic constitutive model was implemented for characterizing the mechanical properties of the amorphous matrix which includes the fibrous cap and the underlying plaque tissue and a nonlinear elastic model was adopted for characterizing the mechanical properties of the fibers. The CZM and elastic parameter values of fibers were identified through an inverse boundary value approach that matches the load-displacement curves from simulation predictions of tensile test of collagen fibers with experimental measurements. The identified parameter values were then used as input in the 3D unit cell model, through which micromechanical factors affecting the resultant traction-separation relation for the unit cell were investigated via a parametric analysis. Results of the parametric analysis showed the applicability of the 3D unit cell model approach for evaluating the micromechanical mechanisms of arterial tissue failure processes.
△ Less
Submitted 19 June, 2018;
originally announced June 2018.
-
An inverse analysis of cohesive zone model parameter values for human fibrous cap mode I tearing
Authors:
Xiaochang Leng,
Lindsey Davis,
Xiaomin Deng,
Tarek Shazly,
Michael A. Sutton,
Susan M. Lessner
Abstract:
Atherosclerotic plaque failure results from various pathophysiological events, with the existence of fibrous cap mode I tearing in the arterial wall, having the potential to block the aortic lumen and correspondingly induce serious clinical conditions.The aim of this study was to quantify the interfacial strength and critical energy release rate of the fibrous tissue across the thickness. in this…
▽ More
Atherosclerotic plaque failure results from various pathophysiological events, with the existence of fibrous cap mode I tearing in the arterial wall, having the potential to block the aortic lumen and correspondingly induce serious clinical conditions.The aim of this study was to quantify the interfacial strength and critical energy release rate of the fibrous tissue across the thickness. in this study, an inverse analysis method via finite element modeling and simulation approach was presented. A cohesive zone model (CZM) was applied to simulate the tearing of the fibrous cap tissue under uniaxial tensile tests along the circumferential direction. A fiber-reinforced hyperelastic model (Holzapfel-Gasser-Ogden) was implemented for characterizing the mechanical properties of bulk material. With the material parameter values of HGO model from inverse analysis process as the input for the bulk material, the interfacial strength and critical energy release rate along the tearing path or failure zones are obtained through the same method as material identification process of HGO model. Results of this study demonstrate the fibrous cap tissue tearing failure processes.
△ Less
Submitted 13 June, 2018;
originally announced June 2018.
-
Experimental and Numerical Evaluations of the Viscoelastic Mechanical Behavior of Arterial Tissue
Authors:
Xiaochang Leng,
Xiaomin Deng,
Suraj Ravindran,
Addis Kidane,
Susan M Lessner,
Michael A Sutton,
Tarek Shazly
Abstract:
The viscoelastic properties of arterial tissue dictate vessel behavior in certain disease states, injury modalities, and during some endovascular procedures. In this study, we characterized the viscoelastic mechanical response of porcine abdominal aortic tissue via uniaxial mechanical experiments on vascular tissue samples coupled with full-field surface strain measurements using the 2-D digital i…
▽ More
The viscoelastic properties of arterial tissue dictate vessel behavior in certain disease states, injury modalities, and during some endovascular procedures. In this study, we characterized the viscoelastic mechanical response of porcine abdominal aortic tissue via uniaxial mechanical experiments on vascular tissue samples coupled with full-field surface strain measurements using the 2-D digital image correlation (DIC) technique. The measured stress relaxation response and intimal surface strain field were used to identify material parameters for a proposed viscoelastic anisotropic (VA) constitutive model of the passive arterial wall. The obtained results show that the VA constitutive model is able to capture the viscoelastic mechanical behavior of the arterial tissue over clinically-relevant time scales. The identified material model and numerical simulations provide a comprehensive description of the passive viscoelastic tissue properties of the arterial wall, and a quantitative understanding of the spatial and directional variability underlying arterial tissue mechanical behavior.
△ Less
Submitted 4 June, 2018;
originally announced June 2018.
-
Mechanical identification of layer-specific properties of mouse carotid arteries using 3D-DIC and a hyperelastic anisotropic constitutive model
Authors:
Pierre Badel,
Stéphane Avril,
Susan Lessner,
Michael A. Sutton
Abstract:
The role of mechanics is known to be of primary order in many arterial diseases; however, determining mechanical properties of arteries remains a challenge. This paper discusses the identifiability of the passive mechanical properties of a mouse carotid artery, taking into account the orientation of collagen fibres in the medial and adventitial layers. On the basis of 3D digital image correlation…
▽ More
The role of mechanics is known to be of primary order in many arterial diseases; however, determining mechanical properties of arteries remains a challenge. This paper discusses the identifiability of the passive mechanical properties of a mouse carotid artery, taking into account the orientation of collagen fibres in the medial and adventitial layers. On the basis of 3D digital image correlation measurements of the surface strain during an inflation/extension test, an inverse identification method is set up. It involves a 3D finite element mechanical model of the mechanical test and an optimisation algorithm. A two-layer constitutive model derived from the Holzapfel model is used, with five and then seven parameters. The five-parameter model is successfully identified providing layer-specific fibre angles. The seven-parameter model is over parameterised, yet it is shown that additional data from a simple tension test make the identification of refined layer-specific data reliable.
△ Less
Submitted 6 April, 2012;
originally announced April 2012.