-
Neutron lifetime measurement with pulsed cold neutrons
Authors:
K. Hirota,
G. Ichikawa,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
R. Kitahara,
J. Koga,
K. Mishima,
T. Mogi,
K. Morikawa,
A. Morishita,
N. Nagakura,
H. Oide,
H. Okabe,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
T. Tomita,
H. Uehara,
T. Yamada
, et al. (4 additional authors not shown)
Abstract:
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas c…
▽ More
The neutron lifetime has been measured by comparing the decay rate with the reaction rate of $^3$He nuclei of a pulsed neutron beam from the spallation neutron source at the Japan Proton Accelerator Research Complex (J-PARC). The decay rate and the reaction rate were determined by simultaneously detecting electrons from the neutron decay and protons from the $^3$He(n,p)$^3$H reaction using a gas chamber of which working gas contains diluted $^3$He. The measured neutron lifetime was $898\,\pm\,10\,_{\rm stat}\,^{+15}_{-18}\,_{\rm sys}\,$s.
△ Less
Submitted 25 November, 2020; v1 submitted 22 July, 2020;
originally announced July 2020.
-
Improved determination of thermal cross section of 14N(n,p)14C for the neutron lifetime measurement
Authors:
R. Kitahara,
K. Hirota,
S. Ieki,
T. Ino,
Y. Iwashita,
M. Kitaguchi,
J. Koga,
K. Mishima,
A. Morishita,
N. Nagakura,
H. Oide,
H. Otono,
Y. Seki,
D. Sekiba,
T. Shima,
H. M. Shimizu,
N. Sumi,
H. Sumino,
K. Taketani,
T. Tomita,
T. Yamada,
S. Yamashita,
M. Yokohashi,
T. Yoshioka
Abstract:
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of…
▽ More
In a neutron lifetime measurement at the Japan Proton Accelerator Complex, the neutron lifetime is calculated by the neutron decay rate and the incident neutron flux. The flux is obtained due to counting the protons emitted from the neutron absorption reaction of ${}^{3}{\rm He}$ gas, which is diluted in a mixture of working gas in a detector. Hence, it is crucial to determine the amount of ${}^{3}{\rm He}$ in the mixture. In order to improve the accuracy of the number density of the ${}^{3}{\rm He}$ nuclei, we suggested to use the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction as a reference because this reaction involves similar kinetic energy as the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction and a smaller reaction cross section to introduce reasonable large partial pressure. The uncertainty of the recommended value of the cross section, however, is not satisfied with our requirement.
In this paper, we report the most accurate experimental value of the cross section of the ${}^{14}{\rm N}({\rm n},{\rm p}){}^{14}{\rm C}$ reaction at a neutron velocity of 2200 m/s, measured relative to the ${}^{3}{\rm He}({\rm n},{\rm p}){}^{3}{\rm H}$ reaction. The result was 1.868 $\pm$ 0.003 (stat.) $\pm$ 0.006 (sys.) b. Additionally, the cross section of the ${}^{17}{\rm O}({\rm n},{\rm α}){}^{14}{\rm C}$ reaction at the neutron velocity is also redetermined as 249 $\pm$ 6 mb.
△ Less
Submitted 2 August, 2019; v1 submitted 26 April, 2019;
originally announced April 2019.
-
Independent Deeply Learned Matrix Analysis for Multichannel Audio Source Separation
Authors:
Shinichi Mogami,
Hayato Sumino,
Daichi Kitamura,
Norihiro Takamune,
Shinnosuke Takamichi,
Hiroshi Saruwatari,
Nobutaka Ono
Abstract:
In this paper, we address a multichannel audio source separation task and propose a new efficient method called independent deeply learned matrix analysis (IDLMA). IDLMA estimates the demixing matrix in a blind manner and updates the time-frequency structures of each source using a pretrained deep neural network (DNN). Also, we introduce a complex Student's t-distribution as a generalized source g…
▽ More
In this paper, we address a multichannel audio source separation task and propose a new efficient method called independent deeply learned matrix analysis (IDLMA). IDLMA estimates the demixing matrix in a blind manner and updates the time-frequency structures of each source using a pretrained deep neural network (DNN). Also, we introduce a complex Student's t-distribution as a generalized source generative model including both complex Gaussian and Cauchy distributions. Experiments are conducted using music signals with a training dataset, and the results show the validity of the proposed method in terms of separation accuracy and computational cost.
△ Less
Submitted 27 June, 2018;
originally announced June 2018.
-
Accurate determination of the absolute 3He/4He ratio of a synthesized helium standard gas (Helium Standard of Japan, HESJ): Towards revision of the atmospheric 3He/4He ratio
Authors:
Kenji Mishima,
Hirochika Sumino,
Takahito Yamada,
Sei Ieki,
Naoki Nagakura,
Hidetoshi Otono,
Hideyuki Oide
Abstract:
The helium standard of Japan, referred to as HESJ, is an inter-laboratory standard for the 3He/4He ratio. While the ratio of 3He and 4He of the HESJ was previously determined by a relative comparison to atmospheric helium, the absolute value of the 3He/4He ratio of the HESJ has not been directly determined yet. Therefore, it relies on the early measurements of that of atmospheric helium. The accur…
▽ More
The helium standard of Japan, referred to as HESJ, is an inter-laboratory standard for the 3He/4He ratio. While the ratio of 3He and 4He of the HESJ was previously determined by a relative comparison to atmospheric helium, the absolute value of the 3He/4He ratio of the HESJ has not been directly determined yet. Therefore, it relies on the early measurements of that of atmospheric helium. The accuracy of the absolute 3He/4He ratios of the atmosphere and other working standards including HESJ is crucial in some applications of helium isotopes, such as tritium-3He dating, surface-exposure age determination based on cosmogenic 3He, and the accurate measurement of the neutron lifetime. In this work, new control samples of helium gases with 3He/4He ratios of 14, 28, and 42 ppm were fabricated with accuracy of 0.25-0.38% using a gas-handling system for a neutron lifetime experiment at Japan Proton Accelerator Research Complex (J-PARC). The relative 3He/4He ratios of these samples and the HESJ were measured using a magnetic-sector-type, single-focusing, noble gas mass spectrometer with a double collector system. As a result, the absolute 3He/4He ratio of the HESJ was determined as 27.36 +/- 0.11 ppm. The atmospheric 3He/4He ratio was determined as 1.340 +/- 0.006 ppm, based on this work.
△ Less
Submitted 2 October, 2018; v1 submitted 21 April, 2018;
originally announced April 2018.
-
Fundamental physics activities with pulsed neutron at J-PARC(BL05)
Authors:
Kenji Mishima,
Shogo Awano,
Yasuhiro Fuwa,
Fumiya Goto,
Christopher C. Haddock,
Masahiro Hino,
Masanori Hirose,
Katsuya Hirota,
Sei Ieki,
Sohei Imajo,
Takashi Ino,
Yoshihisa Iwashita,
Ryo Katayama,
Hiroaki Kawahara,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Jun Koga,
Aya Morishita,
Tomofumi Nagae,
Naoki Nagakura,
Naotaka Naganawa,
Noriko Oi,
Hideyuki Oide,
Hidetoshi Otono,
Yoshichika Seki
, et al. (15 additional authors not shown)
Abstract:
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are develo** an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The…
▽ More
"Neutron Optics and Physics (NOP/ BL05)" at MLF in J-PARC is a beamline for studies of fundamental physics. The beamline is divided into three branches so that different experiments can be performed in parallel. These beam branches are being used to develop a variety of new projects. We are develo** an experimental project to measure the neutron lifetime with total uncertainty of 1 s (0.1%). The neutron lifetime is an important parameter in elementary particle and astrophysics. Thus far, the neutron lifetime has been measured by several groups; however, different values are obtained from different measurement methods. This experiment is using a method with different sources of systematic uncertainty than measurements conducted to date. We are also develo** a source of pulsed ultra-cold neutrons (UCNs) produced from a Doppler shifter are available at the unpolarized beam branch. We are develo** a time focusing device for UCNs, a so called "rebuncher", which can increase UCN density from a pulsed UCN source. At the low divergence beam branch, an experiment to search an unknown intermediate force with nanometer range is performed by measuring the angular dependence of neutron scattering by noble gases. Finally the beamline is also used for the research and development of optical elements and detectors. For example, a position sensitive neutron detector that uses emulsion to achieve sub-micrometer resolution is currently under development. We have succeeded in detecting cold and ultra-cold neutrons using the emulsion detector.
△ Less
Submitted 25 January, 2018; v1 submitted 18 December, 2017;
originally announced December 2017.
-
Precise neutron lifetime experiment using pulsed neutron beams at J-PARC
Authors:
Naoki Nagakura,
Katsuya Hirota,
Sei Ieki,
Takashi Ino,
Yoshihisa Iwashita,
Masaaki Kitaguchi,
Ryunosuke Kitahara,
Kenji Mishima,
Aya Morishita,
Hideyuki Oide,
Hidetoshi Otono,
Risa Sakakibara,
Yoshichika Seki,
Tatsushi Shima,
Hirohiko M. Shimizu,
Tomoaki Sugino,
Naoyuki Sumi,
Hiroshima Sumino,
Kaoru Taketani,
Genki Tanaka,
Tatsuhiko Tomita,
Takahito Yamada,
Satoru Yamashita,
Mami Yokohashi,
Tamaki Yoshioka
Abstract:
The neutron lifetime is one of the basic parameters in the weak interaction, and is used for predicting the light element abundance in the early universe. Our group developed a new setup to measure the lifetime with the goal precision of 0.1% at the polarized beam branch BL05 of MLF, J-PARC. The commissioning data was acquired in 2014 and 2015, and the first set of data to evaluate the lifetime in…
▽ More
The neutron lifetime is one of the basic parameters in the weak interaction, and is used for predicting the light element abundance in the early universe. Our group developed a new setup to measure the lifetime with the goal precision of 0.1% at the polarized beam branch BL05 of MLF, J-PARC. The commissioning data was acquired in 2014 and 2015, and the first set of data to evaluate the lifetime in 2016, which is expected to yield a statistical uncertainty of O(1)%. This paper presents the current analysis results and the future plans to achieve our goal precision.
△ Less
Submitted 10 February, 2017;
originally announced February 2017.
-
Development of time projection chamber for precise neutron lifetime measurement using pulsed cold neutron beams
Authors:
Y. Arimoto,
N. Higashi,
Y. Igarashi,
Y. Iwashita,
T. Ino,
R. Katayama,
R. Kitahara,
M. Kitaguchi,
H. Matsumura,
K. Mishima,
H. Oide,
H. Otono,
R. Sakakibara,
T. Shima,
H. M. Shimizu,
T. Sugino,
N. Sumi,
H. Sumino,
K. Taketani,
G. Tanaka,
M. Tanaka,
K. Tauchi,
A. Toyoda,
T. Yamada,
S. Yamashita
, et al. (2 additional authors not shown)
Abstract:
A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as…
▽ More
A new time projection chamber (TPC) was developed for neutron lifetime measurement using a pulsed cold neutron spallation source at the Japan Proton Accelerator Research Complex (J-PARC). Managing considerable background events from natural sources and the beam radioactivity is a challenging aspect of this measurement. To overcome this problem, the developed TPC has unprecedented features such as the use of polyether-ether-ketone plates in the support structure and internal surfaces covered with $^6$Li-enriched tiles to absorb outlier neutrons. In this paper, the design and performance of the new TPC are reported in detail.
△ Less
Submitted 11 September, 2015; v1 submitted 26 March, 2015;
originally announced March 2015.