Burn-in Test and Thermal Performance Evaluation of Silicon Photomultipliers for the JUNO-TAO Experiment
Authors:
X. Chen,
G. F. Cao,
M. H. Qu,
H. W. Wang,
N. Anfimov,
A. Rybnikov,
J. Y. Xu,
A. Q. Su,
Z. L. Chen,
J. Cao,
Y. C. Li,
M. Qi
Abstract:
This study evaluates more than 4,000 tiles made of Hamamatsu visual-sensitive silicon photomultipier (SiPM), each with dimensions of 5 $\times$ 5 cm$^2$, intended for the central detector of the Taishan Anti-neutrino Observatory (TAO), a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO) aimed at measuring the reactor anti-neutrino energy spectrum with unprecedented energ…
▽ More
This study evaluates more than 4,000 tiles made of Hamamatsu visual-sensitive silicon photomultipier (SiPM), each with dimensions of 5 $\times$ 5 cm$^2$, intended for the central detector of the Taishan Anti-neutrino Observatory (TAO), a satellite experiment of the Jiangmen Underground Neutrino Observatory (JUNO) aimed at measuring the reactor anti-neutrino energy spectrum with unprecedented energy resolution. All SiPM tiles underwent a room temperature burn-in test in the dark for two weeks, while cryogenic testing analyzed the thermal dependence of parameters for some sampled SiPMs. Results from these comprehensive tests provide crucial insights into the long-term performance and stability of the 10 square meters of SiPMs operating at -50°C to detect scintillation photons in the TAO detector. Despite some anomalies awaiting further inspection, all SiPMs successfully passed the burn-in test over two weeks at room temperature, which is equivalent to 6.7 years at -50°C. Results are also used to guide optimal SiPM selection, configuration, and operation, ensuring reliability and sustainability in reactor neutrino measurements. This work also provides insights for a rapid and robust quality assessment in future experiments that employ large-scale SiPMs as detection systems.
△ Less
Submitted 13 June, 2024;
originally announced June 2024.
Comparison between Hadamard and canonical bases for in-situ wavefront correction and the effect of ordering in compressive sensing
Authors:
Dennis Scheidt,
Pedro A. Quinto Su
Abstract:
In this work we compare the Canonical and Hadamard bases for in-situ wavefront correction of a focused Gaussian beam using a spatial light modulator (SLM). The beam is perturbed with a transparent optical element (sparse) or a random scatterer (both prevent focusing at a single spot). The phase corrections are implemented with different basis sizes ($N=64, 256, 1024, 4096$) and the phase contribut…
▽ More
In this work we compare the Canonical and Hadamard bases for in-situ wavefront correction of a focused Gaussian beam using a spatial light modulator (SLM). The beam is perturbed with a transparent optical element (sparse) or a random scatterer (both prevent focusing at a single spot). The phase corrections are implemented with different basis sizes ($N=64, 256, 1024, 4096$) and the phase contribution of each basis element is measured with 3 step interferometry. The field is reconstructed from the complete $3N$ measurements and the correction is implemented by projecting the conjugate phase at the SLM. Our experiments show that in general, the Hadamard basis measurements yield better corrections because every element spans the relevant area of the SLM, reducing the noise in the interferograms. % In contrast, the canonical basis has the fundamental limitation that the area of the elements is proportional to $1/N$, and requires dimensions that are compatible with the spatial period of the grating. In the case of the random scatterer, we were only able to get reasonable corrections with the Hadamard basis and the intensity of the corrected spot increased monotonically with $N$, which is consistent with fast random changes in phase over small spatial scales. We also explore compressive sensing with the Hadamard basis and find that the minimum compression ratio needed to achieve corrections with similar quality to those that use the complete measurements depend on the basis ordering. The best results are reached in the case of the Hadamard-Walsh and cake cutting orderings. Surprisingly, in the case of the random scatterer we find that moderate compression ratios on the order of $10-20\%$ ($N=4096$) allow to recover focused spots, although as expected, the maximum intensities increase monotonically with the number of measurements due to the non sparsity of the signal.
△ Less
Submitted 20 October, 2022;
originally announced October 2022.