-
Design of a Resistive Plate Chamber using additive manufacturing
Authors:
L. Benussi,
S. Bianco,
R. Campagnola,
M. Caponero,
S. Colafranceschi,
H. Gebremedhin,
J. Hess,
J. Horsley,
M. Landis,
S. Meola,
D. Nester,
L. Passamonti,
L. Peachey-Stoner,
R. Peachey-Stoner,
D. Piccolo,
D. Pierluigi,
A. Russo,
G. Saviano,
L. Stutzman,
R. Tezazu
Abstract:
Driven by the recent improvement in additive manufacturing technologies, we designed a detector that can be fully printed with a standard and commercial 3D printer. The main goals of this research concern the marginal design and construction costs, the reproducibility/modularity of the products, and the reduced assembly time. During the first phase of this research, after determining the most suit…
▽ More
Driven by the recent improvement in additive manufacturing technologies, we designed a detector that can be fully printed with a standard and commercial 3D printer. The main goals of this research concern the marginal design and construction costs, the reproducibility/modularity of the products, and the reduced assembly time. During the first phase of this research, after determining the most suitable material, we produced 10 examples of detectors.
△ Less
Submitted 26 October, 2022;
originally announced October 2022.
-
Science Requirements and Detector Concepts for the Electron-Ion Collider: EIC Yellow Report
Authors:
R. Abdul Khalek,
A. Accardi,
J. Adam,
D. Adamiak,
W. Akers,
M. Albaladejo,
A. Al-bataineh,
M. G. Alexeev,
F. Ameli,
P. Antonioli,
N. Armesto,
W. R. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
M. Asai,
E. C. Aschenauer,
S. Aune,
H. Avagyan,
C. Ayerbe Gayoso,
B. Azmoun,
A. Bacchetta,
M. D. Baker,
F. Barbosa,
L. Barion
, et al. (390 additional authors not shown)
Abstract:
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon…
▽ More
This report describes the physics case, the resulting detector requirements, and the evolving detector concepts for the experimental program at the Electron-Ion Collider (EIC). The EIC will be a powerful new high-luminosity facility in the United States with the capability to collide high-energy electron beams with high-energy proton and ion beams, providing access to those regions in the nucleon and nuclei where their structure is dominated by gluons. Moreover, polarized beams in the EIC will give unprecedented access to the spatial and spin structure of the proton, neutron, and light ions. The studies leading to this document were commissioned and organized by the EIC User Group with the objective of advancing the state and detail of the physics program and develo** detector concepts that meet the emerging requirements in preparation for the realization of the EIC. The effort aims to provide the basis for further development of concepts for experimental equipment best suited for the science needs, including the importance of two complementary detectors and interaction regions.
This report consists of three volumes. Volume I is an executive summary of our findings and developed concepts. In Volume II we describe studies of a wide range of physics measurements and the emerging requirements on detector acceptance and performance. Volume III discusses general-purpose detector concepts and the underlying technologies to meet the physics requirements. These considerations will form the basis for a world-class experimental program that aims to increase our understanding of the fundamental structure of all visible matter
△ Less
Submitted 26 October, 2021; v1 submitted 8 March, 2021;
originally announced March 2021.
-
Non-evaporable getter coating chambers for extreme high vacuum
Authors:
Marcy L. Stutzman,
Philip A. Adderley,
Md Abdullah A. Mamun,
Matt Poelker
Abstract:
Techniques for NEG coating a large diameter chamber are presented along with vacuum measurements in the chamber using several pum** configurations, with base pressure as low as 1.56x10^-12 Torr (N2 equivalent) with only a NEG coating and small ion pump. We then describe modifications to the NEG coating process to coat complex geometry chambers for ultra-cold atom trap experiments. Surface analys…
▽ More
Techniques for NEG coating a large diameter chamber are presented along with vacuum measurements in the chamber using several pum** configurations, with base pressure as low as 1.56x10^-12 Torr (N2 equivalent) with only a NEG coating and small ion pump. We then describe modifications to the NEG coating process to coat complex geometry chambers for ultra-cold atom trap experiments. Surface analysis of NEG coated samples are used to measure composition and morphology of the thin films. Finally, pressure measurements are compared for two NEG coated polarized electron source chambers: the 130 kV polarized electron source at Jefferson Lab and the upgraded 350 kV polarized 2 electron source, both of which are approaching or within the extreme high vacuum (XHV) range, defined as P<7.5x10^-13 Torr.
△ Less
Submitted 22 March, 2018; v1 submitted 19 March, 2018;
originally announced March 2018.
-
The effect of heat treatments and coatings on the outgassing rate of stainless steel chambers
Authors:
M. A. Mamun,
A. A. Elmustafa,
M. L. Stutzman,
P. A. Adderley,
M. Poelker
Abstract:
The outgassing rates of three nominally identical 304L stainless steel vacuum chambers were measured to determine the effect of chamber coatings and heat treatments. One chamber was coated with titanium nitride (TiN) and one with amorphous silicon (a-Si) immediately following fabrication. The last chamber was first tested without any coating, and then coated with a-Si following a series of heat tr…
▽ More
The outgassing rates of three nominally identical 304L stainless steel vacuum chambers were measured to determine the effect of chamber coatings and heat treatments. One chamber was coated with titanium nitride (TiN) and one with amorphous silicon (a-Si) immediately following fabrication. The last chamber was first tested without any coating, and then coated with a-Si following a series of heat treatments. The outgassing rate of each chamber was measured at room temperatures between 15 and 30 °C following bakes at temperatures between 90 and 400 °C. Measurements for bare steel showed a significant reduction in the outgassing rate by nearly a factor of 20 after a 400 °C heat treatment (3.5x10-12 Torr L s-1 cm-2 prior to heat treatment, reduced to 1.7x10-13 Torr L s-1 cm-2 following heat treatment). The chambers that were coated with a-Si showed minimal change in outgassing rates with heat treatment, though an outgassing rate reduced by heat treatments prior to a-Si coating was successfully preserved throughout a series of bakes. The TiN coated chamber exhibited remarkably low outgassing rates, up to four orders of magnitude lower than the uncoated stainless steel, but the uncertainty in these rates is large due to the sensitivity limitations of the spinning rotor gauge accumulation measurement and the possibility of a small pump speed due to inhomogeneity in the TiN coating. The outgassing results are discussed in terms of diffusion-limited versus recombination-limited processes.
△ Less
Submitted 27 January, 2014; v1 submitted 16 July, 2013;
originally announced July 2013.
-
New Measurements of the Transverse Beam Asymmetry for Elastic Electron Scattering from Selected Nuclei
Authors:
The HAPPEX,
PREX Collaborations,
:,
S. Abrahamyan,
A. Acha,
A. Afanasev,
Z. Ahmed,
H. Albataineh,
K. Aniol,
D. S. Armstrong,
W. Armstrong,
J. Arrington,
T. Averett,
B. Babineau,
S. L. Bailey,
J. Barber,
A. Barbieri,
A. Beck,
V. Bellini,
R. Beminiwattha,
H. Benaoum,
J. Benesch,
F. Benmokhtar,
P. Bertin,
T. Bielarski
, et al. (173 additional authors not shown)
Abstract:
We have measured the beam-normal single-spin asymmetry $A_n$ in the elastic scattering of 1-3 GeV transversely polarized electrons from $^1$H and for the first time from $^4$He, $^{12}$C, and $^{208}$Pb. For $^1$H, $^4$He and $^{12}$C, the measurements are in agreement with calculations that relate $A_n$ to the imaginary part of the two-photon exchange amplitude including inelastic intermediate st…
▽ More
We have measured the beam-normal single-spin asymmetry $A_n$ in the elastic scattering of 1-3 GeV transversely polarized electrons from $^1$H and for the first time from $^4$He, $^{12}$C, and $^{208}$Pb. For $^1$H, $^4$He and $^{12}$C, the measurements are in agreement with calculations that relate $A_n$ to the imaginary part of the two-photon exchange amplitude including inelastic intermediate states. Surprisingly, the $^{208}$Pb result is significantly smaller than the corresponding prediction using the same formalism. These results suggest that a systematic set of new $A_n$ measurements might emerge as a new and sensitive probe of the structure of heavy nuclei.
△ Less
Submitted 12 October, 2012; v1 submitted 30 August, 2012;
originally announced August 2012.
-
A low-voltage retarding-field Mott polarimeter for photocathode characterization
Authors:
James L. McCarter,
Marcy L. Stutzman,
Kenneth W. Trantham,
Tyler G. Anderson,
April M. Cook,
Timothy J. Gay
Abstract:
Nuclear physics experiments at Thomas Jefferson National Accelerator Facility's CEBAF rely on high polarization electron beams. We describe a recently commissioned system for prequalifying and studying photocathodes for CEBAF with a load-locked, low-voltage polarized electron source coupled to a compact retarding-field Mott polarimeter. The polarimeter uses simplified electrode structures and o…
▽ More
Nuclear physics experiments at Thomas Jefferson National Accelerator Facility's CEBAF rely on high polarization electron beams. We describe a recently commissioned system for prequalifying and studying photocathodes for CEBAF with a load-locked, low-voltage polarized electron source coupled to a compact retarding-field Mott polarimeter. The polarimeter uses simplified electrode structures and operates from 5 to 30 kV. The effective Sherman function for this device has been calibrated by comparison with the CEBAF 5 MeV Mott polarimeter. For elastic scattering from a thick gold target at 20 keV, the effective Sherman function is 0.201(5). Its maximum efficiency at 20 keV, defined as the detected count rate divided by the incident particle current, is 5.4(2) x 10-4, yielding a figure-of-merit, or analyzing power squared times efficiency, of 1.0(1) x 10-5. The operating parameters of this new polarimeter design are compared to previously published data for other compact Mott polarimeters of the retarding-field type.
△ Less
Submitted 29 March, 2010;
originally announced March 2010.