An Open Source, FPGA-based LeKID readout for BLAST-TNG: Pre-flight Results
Authors:
Samuel Gordon,
Bradley Dober,
Adrian Sinclair,
Samuel Rowe,
Sean Bryan,
Philip Mauskopf,
Jason Austermann,
Mark Devlin,
Simon Dicker,
Jiansong Gao,
Gene C. Hilton,
Johannes Hubmayr,
Glenn Jones,
Jeffrey Klein,
Nathan P. Lourie,
Christopher McKenney,
Federico Nati,
Juan D. Soler,
Matthew Strader,
Michael Vissers
Abstract:
We present a highly frequency multiplexed readout for large-format superconducting detector arrays intended for use in the next generation of balloon-borne and space-based sub-millimeter and far-infrared missions. We will demonstrate this technology on the upcoming NASA Next Generation Balloon-borne Large Aperture Sub-millimeter Telescope (BLAST-TNG) to measure the polarized emission of Galactic d…
▽ More
We present a highly frequency multiplexed readout for large-format superconducting detector arrays intended for use in the next generation of balloon-borne and space-based sub-millimeter and far-infrared missions. We will demonstrate this technology on the upcoming NASA Next Generation Balloon-borne Large Aperture Sub-millimeter Telescope (BLAST-TNG) to measure the polarized emission of Galactic dust at wavelengths of 250, 350 and 500 microns. The BLAST-TNG receiver incorporates the first arrays of Lumped Element Kinetic Inductance Detectors (LeKID) along with the first microwave multiplexing readout electronics to fly in a space-like environment and will significantly advance the TRL for these technologies. After the flight of BLAST-TNG, we will continue to improve the performance of the detectors and readout electronics for the next generation of balloon-borne instruments and for use in a future FIR Surveyor.
△ Less
Submitted 16 November, 2016;
originally announced November 2016.
-
Search for Optical Pulsations in PSR J0337+1715
Authors:
M. J. Strader,
A. M. Archibald,
S. R. Meeker,
P. Szypryt,
A. B. Walter,
J. C. van Eyken,
G. Ulbricht,
C. Stoughton,
B. Bumble,
D. L. Kaplan,
B. A. Mazin
Abstract:
We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telesc…
▽ More
We report on a search for optical pulsations from PSR J0337+1715 at its observed radio pulse period. PSR J0337+1715 is a millisecond pulsar (2.7 ms spin period) in a triple hierarchical system with two white dwarfs, and has a known optical counterpart with g-band magnitude 18. The observations were done with the Array Camera for Optical to Near-IR Spectrophotometry (ARCONS) at the 200" Hale telescope at Palomar Observatory. No significant pulsations were found in the range 4000-11000 angstroms, and we can limit pulsed emission in g-band to be fainter than 25 mag.
△ Less
Submitted 16 March, 2016;
originally announced March 2016.
-
The ARCONS Pipeline: Data Reduction for MKID Arrays
Authors:
J. C. van Eyken,
M. J. Strader,
A. B. Walter,
S. R. Meeker,
P. Szypryt,
C. Stoughton,
K. O'Brien,
D. Marsden,
N. K. Rice,
Y. Lin,
B. A. Mazin
Abstract:
The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and…
▽ More
The Array Camera for Optical to Near-IR Spectrophotometry, or ARCONS, is a camera based on Microwave Kinetic Inductance Detectors (MKIDs), a new technology that has the potential for broad application in astronomy. Using an array of MKIDs, the instrument is able to produce time-resolved imaging and low-resolution spectroscopy constructed from detections of individual photons. The arrival time and energy of each photon are recorded in a manner similar to X-ray calorimetry, but at higher photon fluxes. The technique works over a very large wavelength range, is free from fundamental read noise and dark-current limitations, and provides microsecond-level timing resolution. Since the instrument reads out all pixels continuously while exposing, there is no loss of active exposure time to readout. The technology requires a different approach to data reduction compared to conventional CCDs. We outline here the prototype data reduction pipeline developed for ARCONS, though many of the principles are also more broadly applicable to energy-resolved photon counting arrays (e.g., transition edge sensors, superconducting tunnel junctions). We describe the pipeline's current status, and the algorithms and techniques employed in taking data from the arrival of photons at the MKID array to the production of images, spectra, and time-resolved light curves.
△ Less
Submitted 20 July, 2015;
originally announced July 2015.
-
Science with KRAKENS
Authors:
Benjamin A. Mazin,
George Becker,
Kevin France,
Wesley Fraser,
D. Andrew Howell,
Tucker Jones,
Seth Meeker,
Kieran O'Brien,
Jason X. Prochaska,
Brian Siana,
Matthew Strader,
Paul Szypryt,
Shriharsh P. Tendulkar,
Tommaso Treu,
Gautam Vasisht
Abstract:
The Keck science community is entering an era of unprecedented change. Powerful new instrument like ZTF, JWST, LSST, and the ELTs will catalyze this change, and we must be ready to take full advantage to maintain our position of scientific leadership. The best way to do this is to continue the UC and Caltech tradition of technical excellence in instrumentation. In this whitepaper we describe a new…
▽ More
The Keck science community is entering an era of unprecedented change. Powerful new instrument like ZTF, JWST, LSST, and the ELTs will catalyze this change, and we must be ready to take full advantage to maintain our position of scientific leadership. The best way to do this is to continue the UC and Caltech tradition of technical excellence in instrumentation. In this whitepaper we describe a new instrument called KRAKENS to help meet these challenges. KRAKENS uses a unique detector technology (MKIDs) to enable groundbreaking science across a wide range of astrophysical research topics. This document will lay out the detailed expected science return of KRAKENS.
△ Less
Submitted 10 June, 2015;
originally announced June 2015.
-
Direct Detection of SDSS J0926+3624 Orbital Expansion with ARCONS
Authors:
P. Szypryt,
G. E. Duggan,
B. A. Mazin,
S. R. Meeker,
M. J. Strader,
J. C. van Eyken,
D. Marsden,
K. O'Brien,
A. B. Walter,
G. Ulbricht,
T. A. Prince,
C. Stoughton,
B. Bumble
Abstract:
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" tele…
▽ More
AM Canum Venaticorum (AM CVn) stars belong to a class of ultra-compact, short period binaries with spectra dominated largely by helium. SDSS J0926+3624 is of particular interest as it is the first observed eclipsing AM CVn system. We observed SDSS J0926+3624 with the \textbf{Ar}ray \textbf{C}amera for \textbf{O}ptical to \textbf{N}ear-IR \textbf{S}pectrophotometry (ARCONS) at the Palomar 200" telescope. ARCONS uses a relatively new type of energy-resolved photon counters called Microwave Kinetic Inductance Detectors (MKIDs). ARCONS, sensitive to radiation from 350 to 1100 nm, has a time resolution of several microseconds and can measure the energy of a photon to $\sim10%$. We present the light curves for these observations and examine changes in orbital period from prior observations. Using a quadratic ephemeris model, we measure a period rate of change $\dot{P} = (3.07 \pm 0.56)\times 10^{-13}$. In addition, we use the high timing resolution of ARCONS to examine the system's high frequency variations and search for possible quasi-periodic oscillations (QPOs). Finally, we use the instrument's spectral resolution to examine the light curves in various wavelength bands. We do not find any high frequency QPOs or significant spectral variability throughout an eclipse.
△ Less
Submitted 16 September, 2013;
originally announced September 2013.
-
Excess Optical Enhancement Observed with ARCONS for Early Crab Giant Pulses
Authors:
M. J. Strader,
M. D. Johnson,
B. A. Mazin,
G. V. Spiro Jaeger,
C. R. Gwinn,
S. R. Meeker,
P. Szypryt,
J. C. van Eyken,
D. Marsden,
K. O'Brien,
A. B. Walter,
G. Ulbricht,
C. Stoughton,
B. Bumble
Abstract:
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C.…
▽ More
We observe an extraordinary link in the Crab pulsar between the enhancement of an optical pulse and the timing of the corresponding giant radio pulse. At optical through infrared wavelengths, our observations use the high time resolution of ARCONS, a unique superconducting energy-resolving photon-counting array at the Palomar 200-inch telescope. At radio wavelengths, we observe with the Robert C. Byrd Green Bank Telescope and the GUPPI backend. We see an $11.3\pm2.5\%$ increase in peak optical flux for pulses that have an accompanying giant radio pulse arriving near the peak of the optical main pulse, in contrast to a $3.2\pm0.5\%$ increase when an accompanying giant radio pulse arrives soon after the optical peak. We also observe that the peak of the optical main pulse is $2.8\pm0.8\%$ enhanced when there is a giant radio pulse accompanying the optical interpulse. We observe no statistically significant spectral differences between optical pulses accompanied by and not accompanied by giant radio pulses. Our results extend previous observations of optical-radio correlation to the time and spectral domains. Our refined temporal correlation suggests that optical and radio emission are indeed causally linked, and the lack of spectral differences suggests that the same mechanism is responsible for all optical emission.
△ Less
Submitted 8 November, 2013; v1 submitted 12 September, 2013;
originally announced September 2013.
-
ARCONS: A 2024 Pixel Optical through Near-IR Cryogenic Imaging Spectrophotometer
Authors:
B. A. Mazin,
S. R. Meeker,
M. J. Strader,
B. Bumble,
K. O'Brien,
P. Szypryt,
D. Marsden,
J. C. van Eyken,
G. E. Duggan,
G. Ulbricht,
C. Stoughton,
M. Johnson
Abstract:
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without fi…
▽ More
We present the design, construction, and commissioning results of ARCONS, the Array Camera for Optical to Near-IR Spectrophotometry. ARCONS is the first ground-based instrument in the optical through near-IR wavelength range based on Microwave Kinetic Inductance Detectors (MKIDs). MKIDs are revolutionary cryogenic detectors, capable of detecting single photons and measuring their energy without filters or gratings, similar to an X-ray microcalorimeter. MKIDs are nearly ideal, noiseless photon detectors, as they do not suffer from read noise or dark current and have nearly perfect cosmic ray rejection. ARCONS is an Integral Field Spectrograph (IFS) containing a lens-coupled 2024 pixel MKID array yielding a 20"x20" field of view, and has been deployed on the Palomar 200" and Lick 120" telescopes for 24 nights of observing. We present initial results showing that ARCONS and its MKID arrays are now a fully operational and powerful tool for astronomical observations.
△ Less
Submitted 19 June, 2013;
originally announced June 2013.
-
Label-free, Spectroscopic Detection of Leaflet Composition Asymmetry in Vesicles
Authors:
Matthew L. Strader,
Hilton Barbosa de Aguiar,
Alex G. F. de Beer,
Sylvie Roke
Abstract:
Vibrational sum frequency scattering (SFS) has been used to study sub-micron, catanionic vesicles in solution. The vesicles were synthesized from a binary mixture of dodecyltrimethylammonium bromide (DTAB) and sodium dodecylsulfate (SDS) surfactants in deuterated water, which spontaneously assemble into thermodynamically stable vesicles. The stability of these vesicles is attributed to a surfactan…
▽ More
Vibrational sum frequency scattering (SFS) has been used to study sub-micron, catanionic vesicles in solution. The vesicles were synthesized from a binary mixture of dodecyltrimethylammonium bromide (DTAB) and sodium dodecylsulfate (SDS) surfactants in deuterated water, which spontaneously assemble into thermodynamically stable vesicles. The stability of these vesicles is attributed to a surfactant concentration asymmetry between the inner and outer bilayer leaflets. This concentration asymmetry should be observable by SFS due to local inversion symmetry-breaking. Signal corresponding to the symmetric sulfate stretch mode of the SDS head group is observed at 1044 cm, indicating that there is indeed asymmetry in the local structure of the leaflets. The results indicate that it should be possible to measure the interfacial structure of liposomes in aqueous solution and study in-situ processes like the binding of sugars and proteins that are important for many processes in biophysical chemistry.
△ Less
Submitted 30 November, 2010; v1 submitted 23 May, 2010;
originally announced May 2010.