-
Experiments conducted in the burning plasma regime with inertial fusion implosions
Authors:
J. S. Ross,
J. E. Ralph,
A. B. Zylstra,
A. L. Kritcher,
H. F. Robey,
C. V. Young,
O. A. Hurricane,
D. A. Callahan,
K. L. Baker,
D. T. Casey,
T. Doeppner,
L. Divol,
M. Hohenberger,
S. Le Pape,
A. Pak,
P. K. Patel,
R. Tommasini,
S. J. Ali,
P. A. Amendt,
L. J. Atherton,
B. Bachmann,
D. Bailey,
L. R. Benedetti,
L. Berzak Hopkins,
R. Betti
, et al. (127 additional authors not shown)
Abstract:
An experimental program is currently underway at the National Ignition Facility (NIF) to compress deuterium and tritium (DT) fuel to densities and temperatures sufficient to achieve fusion and energy gain. The primary approach being investigated is indirect drive inertial confinement fusion (ICF), where a high-Z radiation cavity (a hohlraum) is heated by lasers, converting the incident energy into…
▽ More
An experimental program is currently underway at the National Ignition Facility (NIF) to compress deuterium and tritium (DT) fuel to densities and temperatures sufficient to achieve fusion and energy gain. The primary approach being investigated is indirect drive inertial confinement fusion (ICF), where a high-Z radiation cavity (a hohlraum) is heated by lasers, converting the incident energy into x-ray radiation which in turn drives the DT fuel filled capsule causing it to implode. Previous experiments reported DT fuel gain exceeding unity [O.A. Hurricane et al., Nature 506, 343 (2014)] and then exceeding the kinetic energy of the imploding fuel [S. Le Pape et al., Phys. Rev. Lett. 120, 245003 (2018)]. We report on recent experiments that have achieved record fusion neutron yields on NIF, greater than 100 kJ with momentary fusion powers exceeding 1PW, and have for the first time entered the burning plasma regime where fusion alpha-heating of the fuel exceeds the energy delivered to the fuel via compression. This was accomplished by increasing the size of the high-density carbon (HDC) capsule, increasing energy coupling, while controlling symmetry and implosion design parameters. Two tactics were successful in controlling the radiation flux symmetry and therefore the implosion symmetry: transferring energy between laser cones via plasma waves, and changing the shape of the hohlraum. In conducting these experiments, we controlled for known sources of degradation. Herein we show how these experiments were performed to produce record performance, and demonstrate the data fidelity leading us to conclude that these shots have entered the burning plasma regime.
△ Less
Submitted 8 November, 2021;
originally announced November 2021.
-
Testing for the Continuous Spectrum of X-Rays Predicted to Accompany the Photoejection of an Atomic Inner Shell Electron
Authors:
Philip Jacobson,
Andrija Rasovic,
Arthur Campello,
Chase Goddard,
Matthew Dykes,
Yuchao Chen,
J. Y. Peter Ko,
Stanislav Stoupin,
Gwen Gardner,
Justin Oh,
Carl Franck
Abstract:
Echoing classical physics, quantum electrodynamics predicts the release of a spectral continuum of electromagnetic radiation upon the sudden acceleration of charged particles in quantum matter. Despite apparent theoretical success in describing sister nuclear processes, known as internal bremsstrahlung, following nuclear beta decay and K capture, the situation of the photoejection of an electron f…
▽ More
Echoing classical physics, quantum electrodynamics predicts the release of a spectral continuum of electromagnetic radiation upon the sudden acceleration of charged particles in quantum matter. Despite apparent theoretical success in describing sister nuclear processes, known as internal bremsstrahlung, following nuclear beta decay and K capture, the situation of the photoejection of an electron from an inner shell of an atom, intraatomic bremsstrahlung (IAB), is far from settled. In this paper we present fresh measurements which rely on contemporary signal processing as well as the high flux available from a synchrotron radiation source to revisit the problem by photoejecting electrons from the innermost shell of copper. For the first time we have sufficient sample statistics to measure the expected spectra at the level expected by contemporary theory. Furthermore, we employ sufficiently thin targets to overcome secondary scattering artifacts. Our approach applies the fluorescence coincidence method to guard against extraneous scattering and multiple incident photon processes. Our observations set a severe upper limit on the rate for IAB: We conclude that current theory overpredicts, by at least 5 sigma, the measured rate for K shell IAB in copper in the range of detected energies below the K fluorescence energy.
△ Less
Submitted 3 November, 2021;
originally announced November 2021.
-
X-ray scattering from a plane parallel slab using radiation transfer considerations
Authors:
Stanislav Stoupin
Abstract:
X-ray scattering power of a plane parallel homogeneous slab of material is derived using radiation intensity transfer equations.The scattering power scales with the ratio of the scattering coefficient of interest to the total attenuation coefficient. The results can be used to guide the choice of slab thickness, scattering geometry and photon energy to maximize scattering power in both elastic and…
▽ More
X-ray scattering power of a plane parallel homogeneous slab of material is derived using radiation intensity transfer equations.The scattering power scales with the ratio of the scattering coefficient of interest to the total attenuation coefficient. The results can be used to guide the choice of slab thickness, scattering geometry and photon energy to maximize scattering power in both elastic and inelastic X-ray scattering experiments.
△ Less
Submitted 28 May, 2020;
originally announced May 2020.
-
High-dynamic-range transmission-mode detection of synchrotron radiation using X-ray excited optical luminescence in diamond
Authors:
Stanislav Stoupin,
Sergey Antipov,
Alexander M. Zaitsev
Abstract:
We demonstrate enhancement of X-ray excited optical luminescence in a 100-micron-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range of 7.6$\times$10$^8$ to 1.26$\times10^{12}$ photons/s/mm$^2$ for hard X-rays (…
▽ More
We demonstrate enhancement of X-ray excited optical luminescence in a 100-micron-thick diamond plate by introduction of defect states via electron beam irradiation and subsequent high-temperature annealing. The resulting X-ray transmission-mode scintillator features a linear response to incident photon flux in the range of 7.6$\times$10$^8$ to 1.26$\times10^{12}$ photons/s/mm$^2$ for hard X-rays (15.9 keV) using exposure times from 0.01 to 5 s. These characteristics enable a real-time transmission-mode imaging of X-ray photon flux density without disruption of X-ray instrument operation.
△ Less
Submitted 18 February, 2020;
originally announced February 2020.
-
Charge density wave with anomalous temperature dependence in UPt2Si2
Authors:
Jooseop Lee,
Karel Prokes,
Sohee Park,
Igor Zaliznyak,
Sachith Dissanayake,
Masaaki Matsuda,
Matthias Frontzek,
Stanislav Stoupin,
Greta L. Chappell,
Ryan E. Baumbach,
Changwon Park,
John A. Mydosh,
Garrett E. Granroth,
Jacob P. C. Ruff
Abstract:
Using single crystal neutron and x-ray diffraction, we discovered a charge density wave (CDW) below 320 K, which accounts for the long-sought origin of the heat capacity and resistivity anomalies in UPt2Si2. The modulation wavevector, Qmod, is intriguingly similar to the Fermi surface nesting wavevector of URu2Si2. Qmod shows an unusual temperature dependence, shifting from commensurate to incomme…
▽ More
Using single crystal neutron and x-ray diffraction, we discovered a charge density wave (CDW) below 320 K, which accounts for the long-sought origin of the heat capacity and resistivity anomalies in UPt2Si2. The modulation wavevector, Qmod, is intriguingly similar to the Fermi surface nesting wavevector of URu2Si2. Qmod shows an unusual temperature dependence, shifting from commensurate to incommensurate position upon cooling and becoming locked at ~ (0.42 0 0) near 180 K. Bulk measurements indicate a cross-over toward a correlated coherent state around the same temperature, suggesting an interplay between the CDW and Kondo-lattice-like coherence before coexisting antiferromagnetic order sets in at TN = 35 K.
△ Less
Submitted 29 June, 2020; v1 submitted 8 August, 2019;
originally announced August 2019.
-
Performance of CVD Diamond Single Crystals as Side-bounce Monochromators in the Laue Geometry at High Photon Energies
Authors:
S. Stoupin,
T. Krawczyk,
J. P. C. Ruff,
K. D. Finkelstein,
H. H. Lee,
R. Huang
Abstract:
We report on performance of chemical vapor deposited (CVD) single crystal diamond plates as side bounce monochromators for high photon energies ($\gtrsim$~20 keV) in the Laue geometry. Several crystals were tested in-operando high-heat-load conditions at A1 undulator station of Cornell High Energy Synchrotron Source. Up to 10$\times$ enhancement in the reflected x-ray flux was observed compared to…
▽ More
We report on performance of chemical vapor deposited (CVD) single crystal diamond plates as side bounce monochromators for high photon energies ($\gtrsim$~20 keV) in the Laue geometry. Several crystals were tested in-operando high-heat-load conditions at A1 undulator station of Cornell High Energy Synchrotron Source. Up to 10$\times$ enhancement in the reflected x-ray flux was observed compared to that delivered by IIa diamond plates grown by high-pressure high-temperature method. Wavefront distortions were measured using analyzer-based x-ray diffraction imaging. Focusing of a portion of the reflected beam was demonstrated using Pt-coated mono capillary optics at a photon energy of 46 keV.
△ Less
Submitted 6 June, 2018;
originally announced June 2018.
-
X-ray reflectivity of chemically vapor deposited diamond single crystals in the Laue geometry
Authors:
S. Stoupin,
J. P. C. Ruff,
T. Krawczyk,
K. D. Finkelstein
Abstract:
Absolute X-ray reflectivity of chemically vapor deposited (CVD) diamond single crystals was measured in the Laue geometry in the double-crystal non-dispersive setting with an asymmetric Si beam conditioner crystal. The measurements were supplemented by rocking curve topography. The measured reflectivity curves are examined in the framework of Darwin-Hamilton approach using a set of two independent…
▽ More
Absolute X-ray reflectivity of chemically vapor deposited (CVD) diamond single crystals was measured in the Laue geometry in the double-crystal non-dispersive setting with an asymmetric Si beam conditioner crystal. The measurements were supplemented by rocking curve topography. The measured reflectivity curves are examined in the framework of Darwin-Hamilton approach using a set of two independent parameters, the characteristic thickness of mosaic blocks and their average angular misorientation. Due to strong extinction effects the width of reflectivity curves does not directly represent the average misorientation of the blocks. Two different sets of parameters were found for the 111 asymmetric reflection in the two different scattering configurations (beam compression and beam expansion). Analysis of the rocking curve topographs shows that this discrepancy can be attributed to inhomogeneity of the diamond crystal microstructure.
△ Less
Submitted 18 May, 2018;
originally announced May 2018.
-
Large-surface-area diamond (111) crystal plates for applications in high-heat-load wavefront-preserving x-ray crystal optics
Authors:
S. Stoupin,
S. Antipov,
J. E. Butler,
A. V. Kolyadin,
A. Katrusha
Abstract:
We report fabrication and results of high-resolution X-ray topography characterization of diamond single crystal plates with a large surface area (10$\times$10 mm$^2$) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics. The plates were fabricated by laser cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature method. Th…
▽ More
We report fabrication and results of high-resolution X-ray topography characterization of diamond single crystal plates with a large surface area (10$\times$10 mm$^2$) and (111) crystal surface orientation for applications in high-heat-load X-ray crystal optics. The plates were fabricated by laser cutting of the (111) facets of diamond crystals grown using high-pressure high-temperature method. The intrinsic crystal quality of a selected 3$\times$7~mm$^2$ crystal region of one of the studied samples was found to be suitable for applications in wavefront-preserving high-heat-load crystal optics. The wavefront characterization was performed using sequential X-ray diffraction topography in the pseudo plane wave configuration and data analysis using rocking curve topography. The variation of the rocking curve width and peak position measured with a spatial resolution of 13$\times$13 $μm^2$ over the selected region were found to be less than one microradian.
△ Less
Submitted 10 May, 2016;
originally announced May 2016.
-
X-ray-induced photoemission yield for surface studies of solids beyond the photoelectron escape depth
Authors:
Stanislav Stoupin,
Bing Shi,
Mikhail Zhernenkov
Abstract:
X-ray-induced photoemission in materials research is commonly acknowledged as a method with a probing depth limited by the escape depth of the photoelectrons. This general statement should be complemented with exceptions arising from the distribution of the X-ray wavefield in the material. Here we show that the integral hard-X-ray-induced photoemission yield is modulated by the Fresnel reflectivit…
▽ More
X-ray-induced photoemission in materials research is commonly acknowledged as a method with a probing depth limited by the escape depth of the photoelectrons. This general statement should be complemented with exceptions arising from the distribution of the X-ray wavefield in the material. Here we show that the integral hard-X-ray-induced photoemission yield is modulated by the Fresnel reflectivity of a multilayer structure with the signal originating well below the photoelectron escape depth. A simple electric self-detection of the integral photoemission yield and Fourier data analysis permit extraction of thicknesses of individual layers. The approach does not require detection of the reflected radiation and can be considered as a framework for non-invasive evaluation of buried layers with hard X-rays under grazing incidence.
△ Less
Submitted 6 May, 2016;
originally announced May 2016.
-
Thermally triggered phononic gaps in liquids at THz scale
Authors:
Dima Bolmatov,
Mikhail Zhernenkov,
Dmitry Zav'yalov,
Stanislav Stoupin,
Alessandro Cunsolo,
Yong Q. Cai
Abstract:
In this paper we present inelastic X-ray scattering experiments in a diamond anvil cell and molecular dynamic simulations to investigate the behavior of phononic excitations in liquid Ar. The spectra calculated using molecular dynamics were found to be in a good agreement with the experimental data. Furthermore, we observe that, upon temperature increases, a low-frequency transverse phononic gap e…
▽ More
In this paper we present inelastic X-ray scattering experiments in a diamond anvil cell and molecular dynamic simulations to investigate the behavior of phononic excitations in liquid Ar. The spectra calculated using molecular dynamics were found to be in a good agreement with the experimental data. Furthermore, we observe that, upon temperature increases, a low-frequency transverse phononic gap emerges while high-frequency propagating modes become evanescent at the THz scale. The effect of strong localization of a longitudinal phononic mode in the supercritical phase is observed for the first time. The evidence for the high-frequency transverse phononic gap due to the transition from an oscillatory to a ballistic dynamic regimes of motion is presented and supported by molecular dynamics simulations. This transition takes place across the Frenkel line thermodynamic limit which demarcates compressed liquid and non-compressed fluid domains on the phase diagram and is supported by calculations within the Green-Kubo phenomenological formalism. These results are crucial to advance the development of novel terahertz thermal devices, phononic lenses, mirrors, and other THz metamaterials.
△ Less
Submitted 14 January, 2016;
originally announced January 2016.
-
Revealing the Mechanism of the Viscous-to-Elastic Crossover in Liquids
Authors:
Dima Bolmatov,
Mikhail Zhernenkov,
Dmitry Zavyalov,
Stanislav Stoupin,
Yong Q. Cai,
Alessandro Cunsolo
Abstract:
In this work, we report on inelastic X-ray scattering experiments combined with the molecular dynamics simulations on deeply supercritical Ar. The presented results unveil the mechanism and regimes of sound propagation in the liquid matter and provide compelling evidence for the adiabatic-to-isothermal longitudinal sound propagation transition. We introduce a Hamiltonian predicting low-frequency t…
▽ More
In this work, we report on inelastic X-ray scattering experiments combined with the molecular dynamics simulations on deeply supercritical Ar. The presented results unveil the mechanism and regimes of sound propagation in the liquid matter and provide compelling evidence for the adiabatic-to-isothermal longitudinal sound propagation transition. We introduce a Hamiltonian predicting low-frequency transverse sound propagation gaps, which is confirmed by experimental findings and molecular dynamics calculations. As a result, a universal link is established between the positive sound dispersion (PSD) phenomenon and the origin of transverse sound propagation revealing the viscous-to-elastic crossover in liquids. The PSD and transverse phononic excitations evolve consistently with theoretical predictions. Both can be considered as a universal fingerprint of the dynamic response of a liquid, which is also observable in a subdomain of supercritical phase. The simultaneous disappearance of both these effects at elevated temperatures is a manifestation of the Frenkel line. We expect that these findings will advance the current understanding of fluids under extreme thermodynamic conditions.
△ Less
Submitted 22 December, 2015;
originally announced December 2015.
-
Single Crystal Diamond Refractive Lens for Focusing of X-rays in Two Dimensions
Authors:
S. Antipov,
S. V. Baryshev,
J. E. Butler,
O. Antipova,
Z. Liu,
S. Stoupin
Abstract:
We report the fabrication and performance evaluation of single crystal diamond refractive x-ray lenses with a paraboloid of rotation form factor for focusing x-rays in two dimensions simultaneously. The lenses were manufactured using a femtosecond laser micromachining process and tested using x-ray synchrotron radiation. Such lenses were stacked together to form a standard compound refractive lens…
▽ More
We report the fabrication and performance evaluation of single crystal diamond refractive x-ray lenses with a paraboloid of rotation form factor for focusing x-rays in two dimensions simultaneously. The lenses were manufactured using a femtosecond laser micromachining process and tested using x-ray synchrotron radiation. Such lenses were stacked together to form a standard compound refractive lens (CRL). Due to the superior physical properties of the material, diamond CRLs are enabling and indispensable wavefront-preserving primary focusing optics for x-ray free-electron lasers and the next-generation synchrotron storage rings. They can be used for highly efficient refocusing of the extremely bright x-ray sources for secondary optical schemes with limited aperture such as nanofocusing Fresnel zone plates and multilayer Laue lenses.
△ Less
Submitted 9 July, 2015; v1 submitted 10 June, 2015;
originally announced June 2015.
-
Diffraction imaging for in-situ characterization of double-crystal x-ray monochromators
Authors:
Stanislav Stoupin,
Zun** Liu,
Steve M. Heald,
Dale Brewe,
Mati Meron
Abstract:
Imaging of the Bragg reflected x-ray beam is proposed and validated as an in-situ method for characterization of performance of double-crystal monochromators under the heat load of intense synchrotron radiation. A sequence of images is collected at different angular positions on the reflectivity curve of the second crystal and analyzed. The method provides rapid evaluation of the wavefront of the…
▽ More
Imaging of the Bragg reflected x-ray beam is proposed and validated as an in-situ method for characterization of performance of double-crystal monochromators under the heat load of intense synchrotron radiation. A sequence of images is collected at different angular positions on the reflectivity curve of the second crystal and analyzed. The method provides rapid evaluation of the wavefront of the exit beam, which relates to local misorientation of the crystal planes along the beam footprint on the thermally distorted first crystal. The measured misorientation can be directly compared to results of finite element analysis. The imaging method offers an additional insight on the local intrinsic crystal quality over the footprint of the incident x-ray beam.
△ Less
Submitted 17 September, 2015; v1 submitted 11 June, 2015;
originally announced June 2015.
-
Self-detection of x-ray Fresnel transmissivity using photoelectron-induced gas ionization
Authors:
Stanislav Stoupin
Abstract:
Electric response of an x-ray mirror enclosed in a gas flow ionization chamber was studied under the conditions of total external reflection for hard x-rays. It is shown that the electric response of the system as a function of the incidence angle is defined by x-ray Fresnel transmissivity and photon-electron attenuation properties of the mirror material. A simple interpretation of quantum yield o…
▽ More
Electric response of an x-ray mirror enclosed in a gas flow ionization chamber was studied under the conditions of total external reflection for hard x-rays. It is shown that the electric response of the system as a function of the incidence angle is defined by x-ray Fresnel transmissivity and photon-electron attenuation properties of the mirror material. A simple interpretation of quantum yield of the system is presented. The approach could serve as a basis for non-invasive in-situ diagnostics of hard x-ray optics, easy access to complementary x-ray transmissivity data in x-ray reflectivity experiments and might also pave the way to advanced schemes for angle and energy resolving x-ray detectors.
△ Less
Submitted 18 January, 2016; v1 submitted 26 May, 2015;
originally announced May 2015.
-
Flux monitoring hard X-ray optics in a single electrode configuration
Authors:
Stanislav Stoupin,
Bing Shi,
John Katsoudas
Abstract:
To explore possibilities for X-ray flux monitoring on optical elements electrical responses of silicon and diamond single crystals and that of an X-ray mirror were studied under exposure to hard X-rays in a single electrode configuration in ambient air. To introduce flux monitoring as a non-invasive capability a platinum electrode was deposited on a small unexposed portion of the entrance surface…
▽ More
To explore possibilities for X-ray flux monitoring on optical elements electrical responses of silicon and diamond single crystals and that of an X-ray mirror were studied under exposure to hard X-rays in a single electrode configuration in ambient air. To introduce flux monitoring as a non-invasive capability a platinum electrode was deposited on a small unexposed portion of the entrance surface of the crystals while for the X-ray mirror the entire mirror surface served as an electrode. It was found that the electrical responses are affected by photoemission and photoionization of the surrounding air. The influence of these factors was quantified using estimations of total electron yield and the ionization current. It is shown that both phenomena can be used for the non-invasive monitoring of hard X-ray flux on the optical elements. Relevant limits of applicability such as detection sensitivity and charge collection efficiency are identified and discussed.
△ Less
Submitted 14 October, 2014;
originally announced October 2014.
-
All-diamond optical assemblies for a beam-multiplexing X-ray monochromator at the Linac Coherent Light Source
Authors:
S. Stoupin,
S. A. Terentyev,
V. D. Blank,
Yu. V. Shvyd'ko,
K. Goetze,
L. Assoufid,
S. N. Polyakov,
M. S. Kuznetsov,
N. V. Kornilov,
J. Katsoudas,
R. Alonso-Mori,
M. Chollet,
Y. Feng,
J. M. Glownia,
H. Lemke,
A. Robert,
S. Song,
M. Sikorski,
D. Zhu
Abstract:
A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal with a thickness of 100 um provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. Here we report on the design, fa…
▽ More
A double-crystal diamond (111) monochromator recently implemented at the Linac Coherent Light Source (LCLS) enables splitting of the primary X-ray beam into a pink (transmitted) and a monochromatic (reflected) branch. The first monochromator crystal with a thickness of 100 um provides sufficient X-ray transmittance to enable simultaneous operation of two beamlines. Here we report on the design, fabrication, and X-ray characterization of the first and second (300-um-thick) crystals utilized in the monochromator and the optical assemblies holding these crystals. Each crystal plate has a region of about 5 X 2 mm2 with low defect concentration, sufficient for use in X-ray optics at the LCLS. The optical assemblies holding the crystals were designed to provide mounting on a rigid substrate and to minimize mounting-induced crystal strain. The induced strain was evaluated using double-crystal X-ray topography and was found to be small over the 5 X 2 mm2 working regions of the crystals.
△ Less
Submitted 23 January, 2014;
originally announced January 2014.
-
Hard X-ray Spectrographs with Resolution Beyond 100 micro-eV
Authors:
Yuri Shvyd'ko,
Stanislav Stoupin,
Kiran Mundboth,
Jungho Kim
Abstract:
Spectrographs take snapshots of photon spectra with array detectors by dispersing photons of different energies into distinct directions and spacial locations. Spectrographs require optics with a large angular dispersion rate as the key component. In visible light optics diffraction gratings are used for this purpose. In the hard x-ray regime, achieving large dispersion rates is a challenge. Here…
▽ More
Spectrographs take snapshots of photon spectra with array detectors by dispersing photons of different energies into distinct directions and spacial locations. Spectrographs require optics with a large angular dispersion rate as the key component. In visible light optics diffraction gratings are used for this purpose. In the hard x-ray regime, achieving large dispersion rates is a challenge. Here we show that multi-crystal, multi-Bragg-reflection arrangements feature cumulative angular dispersion rates almost two orders of magnitude larger than those attainable with a single Bragg reflection. As a result, the multi-crystal arrangements become potential dispersing elements of hard x-ray spectrographs. The hard x-ray spectrograph principles are demonstrated by imaging a spectrum of photons with a record high resolution of $ΔE \simeq 90 μ$eV in hard x-ray regime, using multi-crystal optics as dispersing element. The spectrographs can boost research using inelastic ultra-high-resolution x-ray spectroscopies with synchrotrons and seeded XFELs.
△ Less
Submitted 23 October, 2012;
originally announced October 2012.
-
Angular Dispersion and Anomalous Transmission Cast Ultramonochromatic X Rays
Authors:
Yuri Shvyd'ko,
Stanislav Stoupin,
Deming Shu,
Ruben Khachatryan
Abstract:
Optical spectrometers, instruments that work with monochromatic light, are commonly rated by the spectral bandwidth, which defines the ability to resolve closely spaced spectral components. The ability to detect faint objects among these components, spectral contrast, is another desired aspect. Here we demonstrate that a combined effect of angular dispersion (AD) and anomalous transmission (AT) of…
▽ More
Optical spectrometers, instruments that work with monochromatic light, are commonly rated by the spectral bandwidth, which defines the ability to resolve closely spaced spectral components. The ability to detect faint objects among these components, spectral contrast, is another desired aspect. Here we demonstrate that a combined effect of angular dispersion (AD) and anomalous transmission (AT) of x rays in Bragg reflection from asymmetrically cut crystals can shape spectral distributions of x rays to profiles with record high contrast and small bandwidths.
The AD&AT x-ray optics is implemented as a five-reflection three-crystal arrangement featuring a combination of the above mentioned attributes, so much desirable for x-ray monochromators and analyzers: a spectral contrast of ~ 500, a bandwidth of ~ 0.46 meV and a remarkably large angular acceptance of ~ 107 urad. The new optics can become a foundation for the next generation inelastic x-ray scattering spectrometers for studies of atomic dynamics.
△ Less
Submitted 11 August, 2011; v1 submitted 11 August, 2011;
originally announced August 2011.
-
Nanoradian angular stabilization of x-ray optical components
Authors:
Stanislav Stoupin,
Frank Lenkszus,
Robert Laird,
Kurt Goetze,
Kwang-Je Kim,
Yuri Shvyd'ko
Abstract:
An x-ray free electron laser oscillator (XFELO) has been recently proposed [K. Kim, Y. Shvyd'ko, and S. Reiche, Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and…
▽ More
An x-ray free electron laser oscillator (XFELO) has been recently proposed [K. Kim, Y. Shvyd'ko, and S. Reiche, Phys. Rev. Lett. 100, 244802 (2008)]. Angular orientation and position in space of Bragg mirrors of the XFELO optical cavity must be continuously adjusted to compensate instabilities and maximize the output intensity. An angular stability of about 10 nrad (rms) is required [K. Kim and Y. Shvyd'ko Phys. Rev. STAB 12, 030703 (2009)]. To approach this goal, a feedback loop based on a null-detection principle was designed and used for stabilization of a high energy resolution x-ray monochromator ($ΔE/E \simeq 4 \times 10^{-8}$, $E$ = 23.7 keV) and a high heat load monochromator. Angular stability of about 13 nrad (rms) has been demonstrated for x-ray optical elements of the monochromators.
△ Less
Submitted 8 February, 2010;
originally announced February 2010.