-
All femtosecond optical pump and X-ray probe: holey-axicon for free electron laser
Authors:
V. Anand,
J. Maksimovic,
T. Katkus,
S. H. Ng,
O. Ulcinas,
M. Mikutis,
J. Baltrukonis,
A. Urbas,
G. Slekys,
H. Ogura,
D. Sagae,
T. Pikuz,
T. Somekawa,
N. Ozaki,
A. Vailionis,
G. Seniutinas,
V. Mizeikis,
K. Glazebrook,
J. P. Brodie,
P. R. Stoddart,
L. Rapp,
A. V. Rode,
E. G. Gamaly,
S. Juodkazis
Abstract:
We put forward a co-axial pump(optical)-probe(X-rays) experimental concept and show performance of the optical component. A Bessel beam generator with a central 100 micrometers-diameter hole (on the optical axis) was fabricated using femtosecond (fs) laser structuring inside a silica plate. This flat-axicon optical element produces a needle-like axial intensity distribution which can be used for t…
▽ More
We put forward a co-axial pump(optical)-probe(X-rays) experimental concept and show performance of the optical component. A Bessel beam generator with a central 100 micrometers-diameter hole (on the optical axis) was fabricated using femtosecond (fs) laser structuring inside a silica plate. This flat-axicon optical element produces a needle-like axial intensity distribution which can be used for the optical pump pulse. The fs-X-ray free electron laser (X-FEL) beam of sub-1 micrometer diameter can be introduced through the central hole along the optical axis onto a target as a probe. Different realisations of optical pump are discussed. Such optical elements facilitate alignment of ultra-short fs-pulses in space and time and can be used in light-matter interaction experiments at extreme energy densities on the surface and in the volume of targets. Full advantage of ultra-short 10 fs X-FEL probe pulses with fs-pump(optical) opens an unexplored temporal dimension of phase transitions and the fastest laser-induced rates of material heating and quenching. A wider field of applications of fs-laser-enabled structuring of materials and design of specific optical elements for astrophotonics is presented.
△ Less
Submitted 24 May, 2020;
originally announced May 2020.
-
Percolation threshold gold films on columnar coatings: characterisation for SERS applications
Authors:
Armandas Balcytis,
Tomas Tolenis,
Xuewen Wang,
Gediminas Seniutinas,
Ramutis Drazdys,
Paul R. Stoddart,
Saulius Juodkazis
Abstract:
Percolation of gold films of ~15 nm thickness was controlled to achieve the largest openings during Au deposition. Gold was evaporated on 300-nm-thick films of nanostructured porous and columnar SiO2, TiO2 and MgF2 which were deposited by controlling the angle, rotation speed during film formation and ambient pressure. The gold films were tested for SERS performance using thiophenol reporter molec…
▽ More
Percolation of gold films of ~15 nm thickness was controlled to achieve the largest openings during Au deposition. Gold was evaporated on 300-nm-thick films of nanostructured porous and columnar SiO2, TiO2 and MgF2 which were deposited by controlling the angle, rotation speed during film formation and ambient pressure. The gold films were tested for SERS performance using thiophenol reporter molecules which form a stable self-assembled monolayer on gold. The phase retardation of these SERS substrates was up to 5% for wavelengths in the visible spectral range, as measured by Stokes polarimetry. The SERS intensity on gold percolation films can reach 10^3 counts/(mW.s) for tight focusing in air, while back-side excitation through the substrate has shown the presence of an additional SERS enhancement via the Fresnel near-field mechanism.
△ Less
Submitted 27 March, 2016;
originally announced March 2016.
-
Improved Methods for Fluorescence Background Subtraction from Raman Spectra
Authors:
P. J. Cadusch,
M. M. Hlaing,
S. A. Wade,
S. L. McArthur,
P. R. Stoddart
Abstract:
Raman spectroscopy has attracted interest as a non-invasive optical technique to study the composition and structure of a wide range of materials at the microscopic level. The intrinsic fluorescence background can be orders of magnitude stronger than the Raman scattering and so background removal is one of the foremost challenges for quantitative analysis of Raman spectra in many samples. A range…
▽ More
Raman spectroscopy has attracted interest as a non-invasive optical technique to study the composition and structure of a wide range of materials at the microscopic level. The intrinsic fluorescence background can be orders of magnitude stronger than the Raman scattering and so background removal is one of the foremost challenges for quantitative analysis of Raman spectra in many samples. A range of methods anchored in instrumental and computational programming approaches have been proposed for removing fluorescence background signals. An enhanced adaptive weighting scheme for automated fluorescence removal is reported, applicable to both polynomial fitting and penalised least squares approaches. Analysis of the background fitting results for ensembles of simulated spectra suggests that the method is robust and reliable, and can significantly improve the background fit over the range of signal, shot-noise and background parameters tested, while reducing the subjective nature of the process. The method was also illustrated by application to experimental data generated from aqueous solutions of bulk protein fibrinogen mixed with dextran.
△ Less
Submitted 18 June, 2013;
originally announced June 2013.