-
A 25-micron single photon sensitive kinetic inductance detector
Authors:
Peter K. Day,
Nicholas F. Cothard,
Christopher Albert,
Logan Foote,
Elijah Kane,
Byeong H. Eom,
Ritoban Basu Thakur,
Reinier M. J. Janssen,
Andrew Beyer,
Pierre Echternach,
Sven van Berkel,
Steven Hailey-Dunsheath,
Thomas R. Stevenson,
Shahab Dabironezare,
Jochem J. A. Baselmans,
Jason Glenn,
C. Matt Bradford,
Henry G. Leduc
Abstract:
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integ…
▽ More
We report measurements characterizing the performance of a kinetic inductance detector array designed for a wavelength of 25 microns and very low optical background level suitable for applications such as a far-infrared instrument on a cryogenically cooled space telescope. In a pulse counting mode of operation at low optical flux, the detectors can resolve individual 25-micron photons. In an integrating mode, the detectors remain photon noise limited over more than six orders of magnitude in absorbed power from 70 zW to 200 fW, with a limiting NEP of 4.6 x 10^-20 W/rtHz at 1 Hz. In addition, the detectors are highly stable with flat power spectra under optical load down to 1 mHz. Operational parameters of the detector are determined including the efficiency of conversion of the incident optical power into quasiparticles in the aluminum absorbing element and the quasiparticle self-recombination constant.
△ Less
Submitted 14 May, 2024; v1 submitted 15 April, 2024;
originally announced April 2024.
-
Optimization of an Optical Testbed for Characterization of EXCLAIM u-Spec Integrated Spectrometers
Authors:
Maryam Rahmani,
Emily M. Barrentine,
Eric R. Switzer,
Alyssa Barlis,
Ari D. Brown,
Giuseppe Cataldo,
Jake A. Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Henry Grant,
James Hays-Wehle,
Wen-Ting Hsieh,
Vilem Mikula,
S. Harvey Moseley,
Omid Noroozian,
Manuel A. Quijada,
Jessica Patel,
Thomas R. Stevenson,
Carole Tucker,
Kongpop U-Yen,
Carolyn G. Volpert,
Edward J. Wollack
Abstract:
We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction…
▽ More
We describe a testbed to characterize the optical response of compact superconducting on-chip spectrometers in development for the Experiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) mission. EXCLAIM is a balloonborne far-infrared experiment to probe the CO and CII emission lines in galaxies from redshift 3.5 to the present. The spectrometer, called u-Spec, comprises a diffraction grating on a silicon chip coupled to kinetic inductance detectors (KIDs) read out via a single microwave feedline. We use a prototype spectrometer for EXCLAIM to demonstrate our ability to characterize the spectrometers spectral response using a photomixer source. We utilize an on-chip reference detector to normalize relative to spectral structure from the off-chip optics and a silicon etalon to calibrate the absolute frequency.
△ Less
Submitted 12 December, 2023;
originally announced December 2023.
-
Optical Characterization & Testbed Development for μ-Spec Integrated Spectrometers
Authors:
Maryam Rahmani,
Alyssa Barlis,
Emily M. Barrentine,
Ari D. Brown,
Berhanu T. Bulcha,
Giuseppe Cataldo,
Jake Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Henry Grant,
James Hays-Wehle,
Wen-Ting Hsieh,
Vilem Mikula,
S. Harvey Moseley,
Omid Noroozian,
Trevor R. Oxholm,
Manuel A. Quijada,
Jessica Patel,
Thomas R. Stevenson,
Eric R. Switzer,
Carole Tucker,
Kongpop U-Yen,
Carolyn Volpert,
Edward J. Wollack
Abstract:
This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrated spectrometer that is an analog to a Rowland-type grating spectrometer. It employs a single-crystal silicon substrate with niobium microstrip lines and aluminum kinetic inductance detectors (KIDs). Current designs with…
▽ More
This paper describes a cryogenic optical testbed developed to characterize u-Spec spectrometers in a dedicated dilution refrigerator (DR) system. u-Spec is a far-infrared integrated spectrometer that is an analog to a Rowland-type grating spectrometer. It employs a single-crystal silicon substrate with niobium microstrip lines and aluminum kinetic inductance detectors (KIDs). Current designs with a resolution of 512 are in fabrication for the EXCLAIM (Experiment for Cryogenic Large Aperture Intensity Map**) balloon mission. The primary spectrometer performance and design parameters are efficiency, NEP, inter-channel isolation, spectral resolution, and frequency response for each channel. Here we present the development and design of an optical characterization facility and preliminary validation of that facility with earlier prototype R=64 devices. We have conducted and describe initial optical measurements of R = 64 devices using a swept photomixer line source. We also discuss the test plan for optical characterization of the EXCLAIM R = 512 u-Spec devices in this new testbed.
△ Less
Submitted 12 August, 2022;
originally announced August 2022.
-
Operational Optimization to Maximize Dynamic Range in EXCLAIM Microwave Kinetic Inductance Detectors
Authors:
Trevor M. Oxholm,
Eric R. Switzer,
Emily M. Barrentine,
Thomas Essinger-Hileman,
James P. Hays-Wehle,
Philip D. Mauskopf,
Omid Noroozian,
Maryam Rahmani,
Adrian K. Sinclair,
Ryan Stephenson,
Thomas R. Stevenson,
Peter T. Timbie,
Carolyn Volpert,
Eric Weeks
Abstract:
Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For th…
▽ More
Microwave Kinetic Inductance Detectors (MKIDs) are highly scalable detectors that have demonstrated nearly background-limited sensitivity in the far-infrared from high-altitude balloon-borne telescopes and space-like laboratory environments. In addition, the detectors have a rich design space with many optimizable parameters, allowing highly sensitive measurements over a wide dynamic range. For these reasons, MKIDs were chosen for the Experiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM), a balloon-borne telescope targeting nearly background-limited performance in a high-altitude atmospheric environment from 420-540 GHz. We describe MKID optimization in the specific context of EXCLAIM and provide general results that apply to broader applications. Extending the established approach of tone frequency tracking, we show that readout power optimization enables significant, further improvement in dynamic range.
△ Less
Submitted 28 April, 2022;
originally announced April 2022.
-
μ-Spec Spectrometers for the EXCLAIM Instrument
Authors:
Mona Mirzaei,
Emily M. Barrentine,
Berhanu T. Bulcha,
Giuseppe Cataldo,
Jake A. Connors,
Negar Ehsan,
Thomas M. Essinger-Hileman,
Larry A. Hess,
Jonas W. Mugge-Durum,
Omid Noroozian,
Trevor M. Oxholm,
Thomas R. Stevenson,
Eric R. Switzer,
Carolyn G. Volpert,
Edward J. Wollack
Abstract:
The EXperiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0 to 3.5, using an intensity map** approach. EXCLAIM will broaden our understanding of these elemental and molecular gases and the role they play in star formation processes across cosmic time…
▽ More
The EXperiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) is a cryogenic balloon-borne instrument that will map carbon monoxide and singly-ionized carbon emission lines across redshifts from 0 to 3.5, using an intensity map** approach. EXCLAIM will broaden our understanding of these elemental and molecular gases and the role they play in star formation processes across cosmic time scales. The focal plane of EXCLAIM's cryogenic telescope features six μ-Spec spectrometers. μ-Spec is a compact, integrated grating-analog spectrometer, which uses meandered superconducting niobium microstrip transmission lines on a single-crystal silicon dielectric to synthesize the grating. It features superconducting aluminum microwave kinetic inductance detectors (MKIDs), also in a microstrip architecture. The spectrometers for EXCLAIM couple to the telescope optics via a hybrid planar antenna coupled to a silicon lenslet. The spectrometers operate from 420 to 540 GHz with a resolving power R=λ/Δλ=512 and employ an array of 355 MKIDs on each spectrometer. The spectrometer design targets a noise equivalent power (NEP) of 2x10-18W/\sqrt{Hz} (defined at the input to the main lobe of the spectrometer lenslet beam, within a 9-degree half width), enabled by the cryogenic telescope environment, the sensitive MKID detectors, and the low dielectric loss of single-crystal silicon. We report on these spectrometers under development for EXCLAIM, providing an overview of the spectrometer and component designs, the spectrometer fabrication process, fabrication developments since previous prototype demonstrations, and the current status of their development for the EXCLAIM mission.
△ Less
Submitted 27 January, 2021;
originally announced January 2021.
-
The Experiment for Cryogenic Large-aperture Intensity Map** (EXCLAIM)
Authors:
P. A. R. Ade,
C. J. Anderson,
E. M. Barrentine,
N. G. Bellis,
A. D. Bolatto,
P. C. Breysse,
B. T. Bulcha,
G. Cataldo,
J. A. Connors,
P. W. Cursey,
N. Ehsan,
H. C. Grant,
T. M. Essinger-Hileman,
L. A. Hess,
M. O. Kimball,
A. J. Kogut,
A. D. Lamb,
L. N. Lowe,
P. D. Mauskopf,
J. McMahon,
M. Mirzaei,
S. H. Moseley,
J. W. Mugge-Durum,
O. Noroozian,
U. Pen
, et al. (11 additional authors not shown)
Abstract:
The EXperiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity map** approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540…
▽ More
The EXperiment for Cryogenic Large-Aperture Intensity Map** (EXCLAIM) is a cryogenic balloon-borne instrument that will survey galaxy and star formation history over cosmological time scales. Rather than identifying individual objects, EXCLAIM will be a pathfinder to demonstrate an intensity map** approach, which measures the cumulative redshifted line emission. EXCLAIM will operate at 420-540 GHz with a spectral resolution R=512 to measure the integrated CO and [CII] in redshift windows spanning 0 < z < 3.5. CO and [CII] line emissions are key tracers of the gas phases in the interstellar medium involved in star-formation processes. EXCLAIM will shed light on questions such as why the star formation rate declines at z < 2, despite continued clustering of the dark matter. The instrument will employ an array of six superconducting integrated grating-analog spectrometers (micro-spec) coupled to microwave kinetic inductance detectors (MKIDs). Here we present an overview of the EXCLAIM instrument design and status.
△ Less
Submitted 15 December, 2019;
originally announced December 2019.
-
Multimode bolometer development for the PIXIE instrument
Authors:
Peter C. Nagler,
Kevin T. Crowley,
Kevin L. Denis,
Archana M. Devasia,
Dale J. Fixsen,
Alan J. Kogut,
George Manos,
Scott Porter,
Thomas R. Stevenson
Abstract:
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances i…
▽ More
The Primordial Inflation Explorer (PIXIE) is an Explorer-class mission concept designed to measure the polarization and absolute intensity of the cosmic microwave background. In the following, we report on the design, fabrication, and performance of the multimode polarization-sensitive bolometers for PIXIE, which are based on silicon thermistors. In particular we focus on several recent advances in the detector design, including the implementation of a scheme to greatly raise the frequencies of the internal vibrational modes of the large-area, low-mass optical absorber structure consisting of a grid of micromachined, ion-implanted silicon wires. With $\sim30$ times the absorbing area of the spider-web bolometers used by Planck, the tensioning scheme enables the PIXIE bolometers to be robust in the vibrational and acoustic environment at launch of the space mission. More generally, it could be used to reduce microphonic sensitivity in other types of low temperature detectors. We also report on the performance of the PIXIE bolometers in a dark cryogenic environment.
△ Less
Submitted 14 November, 2016;
originally announced November 2016.
-
Silicon-Based Antenna-Coupled Polarization-Sensitive Millimeter-Wave Bolometer Arrays for Cosmic Microwave Background Instruments
Authors:
Karwan Rostem,
Aamir Ali,
John W. Appel,
Charles L. Bennett,
Ari Brown,
Meng-** Chang,
David T. Chuss,
Felipe A. Colazo,
Nick Costen,
Kevin L. Denis,
Tom Essinger-Hileman,
Ron Hu,
Tobias A. Marriage,
Samuel H. Moseley,
Thomas R. Stevenson,
Kongpop U-Yen,
Edward J. Wollack,
Zhilei Xu
Abstract:
We describe feedhorn-coupled polarization-sensitive detector arrays that utilize monocrystalline silicon as the dielectric substrate material. Monocrystalline silicon has a low-loss tangent and repeatable dielectric constant, characteristics that are critical for realizing efficient and uniform superconducting microwave circuits. An additional advantage of this material is its low specific heat. I…
▽ More
We describe feedhorn-coupled polarization-sensitive detector arrays that utilize monocrystalline silicon as the dielectric substrate material. Monocrystalline silicon has a low-loss tangent and repeatable dielectric constant, characteristics that are critical for realizing efficient and uniform superconducting microwave circuits. An additional advantage of this material is its low specific heat. In a detector pixel, two Transition-Edge Sensor (TES) bolometers are antenna-coupled to in-band radiation via a symmetric planar orthomode transducer (OMT). Each orthogonal linear polarization is coupled to a separate superconducting microstrip transmission line circuit. On-chip filtering is employed to both reject out-of-band radiation from the upper band edge to the gap frequency of the niobium superconductor, and to flexibly define the bandwidth for each TES to meet the requirements of the application. The microwave circuit is compatible with multi-chroic operation. Metalized silicon platelets are used to define the backshort for the waveguide probes. This micro-machined structure is also used to mitigate the coupling of out-of-band radiation to the microwave circuit. At 40 GHz, the detectors have a measured efficiency of 90%. In this paper, we describe the development of the 90 GHz detector arrays that will be demonstrated using the Cosmology Large Angular Scale Surveyor (CLASS) ground-based telescope.
△ Less
Submitted 30 August, 2016;
originally announced August 2016.
-
Scalable background-limited polarization-sensitive detectors for mm-wave applications
Authors:
Karwan Rostem,
Aamir Ali,
John W. Appel,
Charles L. Bennett,
David T. Chuss,
Felipe A. Colazo,
Erik Crowe,
Kevin L. Denis,
Tom Essinger-Hileman,
Tobias A. Marriage,
Samuel H. Moseley,
Thomas R. Stevenson,
Deborah W. Towner,
Kongpop U-Yen,
Edward J. Wollack
Abstract:
We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and…
▽ More
We report on the status and development of polarization-sensitive detectors for millimeter-wave applications. The detectors are fabricated on single-crystal silicon, which functions as a low-loss dielectric substrate for the microwave circuitry as well as the supporting membrane for the Transition-Edge Sensor (TES) bolometers. The orthomode transducer (OMT) is realized as a symmetric structure and on-chip filters are employed to define the detection bandwidth. A hybridized integrated enclosure reduces the high-frequency THz mode set that can couple to the TES bolometers. An implementation of the detector architecture at Q-band achieves 90% efficiency in each polarization. The design is scalable in both frequency coverage, 30-300 GHz, and in number of detectors with uniform characteristics. Hence, the detectors are desirable for ground-based or space-borne instruments that require large arrays of efficient background-limited cryogenic detectors.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
Precision control of thermal transport in cryogenic single-crystal silicon devices
Authors:
Karwan Rostem,
David T. Chuss,
Felipe A. Colazo,
Erik J. Crowe,
Kevin L. Denis,
Nathan P. Lourie,
Samuel H. Moseley,
Thomas R. Stevenson,
Edward J. Wollack
Abstract:
We report on the diffusive-ballistic thermal conductance of multi-moded single-crystal silicon beams measured below 1 K. It is shown that the phonon mean-free-path $\ell$ is a strong function of the surface roughness characteristics of the beams. This effect is enhanced in diffuse beams with lengths much larger than $\ell$, even when the surface is fairly smooth, 5-10 nm rms, and the peak thermal…
▽ More
We report on the diffusive-ballistic thermal conductance of multi-moded single-crystal silicon beams measured below 1 K. It is shown that the phonon mean-free-path $\ell$ is a strong function of the surface roughness characteristics of the beams. This effect is enhanced in diffuse beams with lengths much larger than $\ell$, even when the surface is fairly smooth, 5-10 nm rms, and the peak thermal wavelength is 0.6 $μ$m. Resonant phonon scattering has been observed in beams with a pitted surface morphology and characteristic pit depth of 30 nm. Hence, if the surface roughness is not adequately controlled, the thermal conductance can vary significantly for diffuse beams fabricated across a wafer. In contrast, when the beam length is of order $\ell$, the conductance is dominated by ballistic transport and is effectively set by the beam area. We have demonstrated a uniformity of $\pm$8% in fractional deviation for ballistic beams, and this deviation is largely set by the thermal conductance of diffuse beams that support the micro-electro-mechanical device and electrical leads. In addition, we have found no evidence for excess specific heat in single-crystal silicon membranes. This allows for the precise control of the device heat capacity with normal metal films. We discuss the results in the context of the design and fabrication of large-format arrays of far-infrared and millimeter wavelength cryogenic detectors.
△ Less
Submitted 5 March, 2014;
originally announced March 2014.
-
Angular and Polarization Response of Multimode Sensors with Resistive-Grid Absorbers
Authors:
Akito Kusaka,
Edward J. Wollack,
Thomas R. Stevenson
Abstract:
High sensitivity receiver systems with near ideal polarization sensitivity are highly desirable for development of millimeter and sub-millimeter radio astronomy. Multimoded bolometers provide a unique solution to achieve such sensitivity, for which hundreds of single-mode sensors would otherwise be required. The primary concern in employing such multimoded sensors for polarimetery is the control o…
▽ More
High sensitivity receiver systems with near ideal polarization sensitivity are highly desirable for development of millimeter and sub-millimeter radio astronomy. Multimoded bolometers provide a unique solution to achieve such sensitivity, for which hundreds of single-mode sensors would otherwise be required. The primary concern in employing such multimoded sensors for polarimetery is the control of the polarization systematics. In this paper, we examine the angular- and polarization- dependent absorption pattern of a thin resistive grid or membrane, which models an absorber used for a multimoded bolometer. The result shows that a freestanding thin resistive absorber with a surface resistivity of η/2, where η is the impedance of free space, attains a beam pattern with equal E- and H-plane responses, leading to zero cross polarization. For a resistive-grid absorber, the condition is met when a pair of grids is positioned orthogonal to each other and both have a resistivity of η/2. When a reflective backshort termination is employed to improve absorption efficiency, the cross-polar level can be suppressed below -30 dB if acceptance angle of the sensor is limited to <60degrees. The small cross-polar systematics have even-parity patterns and do not contaminate the measurements of odd-parity polarization patterns, for which many of recent instruments for cosmic microwave background are designed. Underlying symmetry that suppresses these cross-polar systematics is discussed in detail. The estimates and formalism provided in this paper offer key tools in the design consideration of the instruments using the multimoded polarimeters.
△ Less
Submitted 8 January, 2014;
originally announced January 2014.
-
Two stage superconducting quantum interference device amplifier in a high-Q gravitational wave transducer
Authors:
Gregory M. Harry,
Insik **,
Ho Jung Paik,
Thomas R. Stevenson,
Frederick C. Wellstood
Abstract:
We report on the total noise from an inductive motion transducer for a gravitational-wave antenna. The transducer uses a two-stage SQUID amplifier and has a noise temperature of 1.1 mK, of which 0.70 mK is due to back-action noise from the SQUID chip. The total noise includes thermal noise from the transducer mass, which has a measured Q of 2.60 X 10^6. The noise temperature exceeds the expected…
▽ More
We report on the total noise from an inductive motion transducer for a gravitational-wave antenna. The transducer uses a two-stage SQUID amplifier and has a noise temperature of 1.1 mK, of which 0.70 mK is due to back-action noise from the SQUID chip. The total noise includes thermal noise from the transducer mass, which has a measured Q of 2.60 X 10^6. The noise temperature exceeds the expected value of 3.5 μK by a factor of 200, primarily due to voltage noise at the input of the SQUID. Noise from flux trapped on the chip is found to be the most likely cause.
△ Less
Submitted 26 January, 2000; v1 submitted 21 October, 1999;
originally announced October 1999.
-
Detectability of gravitational wave events by spherical resonant-mass antennas
Authors:
Gregory M. Harry,
Thomas R. Stevenson,
Ho Jung Paik
Abstract:
We have calculated signal-to-noise ratios for eight spherical resonant-mass antennas interacting with gravitational radiation from inspiralling and coalescing binary neutron stars and from the dynamical and secular bar-mode instability of a rapidly rotating star. We find that by using technology that could be available in the next several years, spherical antennas can detect neutron star inspira…
▽ More
We have calculated signal-to-noise ratios for eight spherical resonant-mass antennas interacting with gravitational radiation from inspiralling and coalescing binary neutron stars and from the dynamical and secular bar-mode instability of a rapidly rotating star. We find that by using technology that could be available in the next several years, spherical antennas can detect neutron star inspiral and coalescence at a distance of 15 Mpc and the dynamical bar-mode instability at a distance of 2 Mpc.
△ Less
Submitted 13 May, 1996; v1 submitted 9 February, 1996;
originally announced February 1996.