-
Time-of-Flight Three Dimensional Neutron Diffraction in Transmission Mode for Map** Crystal Grain Structures
Authors:
Alberto Cereser,
Markus Strobl,
Stephen Hall,
Axel Steuwer,
Ryoji Kiyanagi,
Anton Tremsin,
Erik Bergbäck Knudsen,
Takenao Shinohara,
Peter Willendrup,
Alice Bastos da Silva Fanta,
Srinivasan Iyengar,
Peter Mahler Larsen,
Takayasu Hanashima,
Taketo Moyoshi,
Peter M. Kadletz,
Philip Krooß,
Thomas Niendorf,
Morten Sales,
Wolfgang W. Schmahl,
Søren Schmidt
Abstract:
The physical properties of polycrystalline materials depend on their microstructure, which is the nano-to-centimeter-scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study bulk samples with s…
▽ More
The physical properties of polycrystalline materials depend on their microstructure, which is the nano-to-centimeter-scale arrangement of phases and defects in their interior. Such microstructure depends on the shape, crystallographic phase and orientation, and interfacing of the grains constituting the material. This article presents a new non-destructive 3D technique to study bulk samples with sizes in the cm range with a resolution of hundred micrometers: time-of-flight three-dimensional neutron diffraction (ToF 3DND). Compared to existing analogous X-ray diffraction techniques, ToF 3DND enables studies of samples that can be both larger in size and made of heavier elements. Moreover, ToF 3DND facilitates the use of complicated sample environments. The basic ToF 3DND setup, utilizing an imaging detector with high spatial and temporal resolution, can easily be implemented at a time-of-flight neutron beamline. The technique was developed and tested with data collected at the Materials and Life Science Experimental Facility of the Japan Proton Accelerator Complex (J-PARC) for an iron sample. We successfully reconstructed the shape of 108 grains and developed an indexing procedure. The reconstruction algorithms have been validated by reconstructing two stacked Co-Ni-Ga single crystals and by comparison with a grain map obtained by post-mortem electron backscatter diffraction (EBSD).
△ Less
Submitted 20 April, 2017;
originally announced April 2017.
-
The preparation of Zr-deuteride and phase stability studies of the Zr-D system
Authors:
T. Maimaitiyili,
A. Steuwer,
C. Bjerkén,
J. Blomqvist,
M. Hoelzel,
J. C. Ion,
O. Zanellato
Abstract:
Deuteride phases in the zirconium-deuterium system in the temperature range 25-286$\celsius$ have been studied in-situ by high resolution neutron diffraction. The study primarily focused on observations of $δ\rightarrow γ$ transformation at 180$\celsius$, and the peritectoid reaction $α+ δ\leftrightarrow γ$ at 255$\celsius$ in commercial grade Zr powder that was deuterated to a deuterium/Zr ratio…
▽ More
Deuteride phases in the zirconium-deuterium system in the temperature range 25-286$\celsius$ have been studied in-situ by high resolution neutron diffraction. The study primarily focused on observations of $δ\rightarrow γ$ transformation at 180$\celsius$, and the peritectoid reaction $α+ δ\leftrightarrow γ$ at 255$\celsius$ in commercial grade Zr powder that was deuterated to a deuterium/Zr ratio of one to one. A detailed description of the zirconium deuteride preparation route by high temperature gas loading is also described. The lattice parameters of $α$-Zr, $δ$-ZrD$_x$ and $ε$-ZrD$_x$ were determined by whole pattern crystal structure analysis, using Rietveld and Pawley refinements, and are in good agreement with values reported in the literature. The controversial $γ$-hydride phase was observed both in-situ and ex-situ in deuterated Zr powder after a heat treatment at 286$\celsius$ and slow cooling.
△ Less
Submitted 9 January, 2017;
originally announced January 2017.
-
In-situ hydrogen charging of zirconium powder to study isothermal percipitation of hydrides and determination of Zr-hydride crystal structure
Authors:
T. Maimaitiyili,
A. Steuwer,
J. Blomquist,
B. Matthew,
Z. Olivier,
J. Andrieux,
C. Bjerken,
R. Fabienne
Abstract:
Zirconium alloys are widely used in the nuclear industry because of their high strength, good corrosion resistance and low neutron absorption cross-section. However, zirconium has strong affinity for hydrogen which leads to hydrogen concentration build-up over time. It is well known that the formation of hydrides will degrade the material and leads to, for example, delayed hydride cracking during…
▽ More
Zirconium alloys are widely used in the nuclear industry because of their high strength, good corrosion resistance and low neutron absorption cross-section. However, zirconium has strong affinity for hydrogen which leads to hydrogen concentration build-up over time. It is well known that the formation of hydrides will degrade the material and leads to, for example, delayed hydride cracking during high burn up. Even though zirconium hydrides have been studied for several decades, there still remain some controversies regarding the formation mechanisms, exact crystal structure, and stability of various hydride phases. This study uses high resolution synchrotron radiation as a probing tool to observe the precipitation and dissolution of hydrides in highly pure zirconium powder during in-situ hydrogen charging. The experiment enabled the direct observation of the hydride formation and phase transformations. It, also, provided high quality data for crystal structure determination.
△ Less
Submitted 20 August, 2014;
originally announced August 2014.
-
Neutron Radiography Analysis of a Transient Liquid Phase Joint
Authors:
H. Ballhausen,
H. Abele,
R. S. Eccleston,
R. Gaehler,
A. J. Smith,
A. Steuwer,
A. Van Overberghe
Abstract:
Neutron radiography in many cases is the only non-destructive technique available for the analysis of a wide range of samples from metallurgy, materials engineering and materials testing. In this paper the potential of the technique is illustrated for a transient liquid phase (TLP) joint.
TLP bonding produces interface free and stress free joints. The quality and properties of the joint depend…
▽ More
Neutron radiography in many cases is the only non-destructive technique available for the analysis of a wide range of samples from metallurgy, materials engineering and materials testing. In this paper the potential of the technique is illustrated for a transient liquid phase (TLP) joint.
TLP bonding produces interface free and stress free joints. The quality and properties of the joint depend on the diffusion of an interlayer into the base material. A TLP joint is visualised and the diffusion profile of the boron contained in the bonding additives is determined. Parameters of the bonding process are determined quantitatively from this profile, and flaws in the joint are detected.
△ Less
Submitted 19 April, 2006;
originally announced April 2006.