-
The CMS Fast Beam Condition Monitor for HL-LHC
Authors:
G. Auzinger,
H. Bakhshiansohi,
A. Dabrowski,
A. G. Delannoy,
A. Dierlamm,
M. Dragicevic,
A. Gholami,
G. Gomez,
M. Guthoff,
M. Haranko,
A. Homna,
M. Jenihhin,
J. Kaplon,
O. Karacheban,
B. Korcsmáros,
W. H. Liu,
A. Lokhovitskiy,
R. Loos,
S. Mallows,
J. Michel,
V. Myronenko,
G. Pásztor,
M. Pari,
J. Schwandt,
M. Sedghi
, et al. (6 additional authors not shown)
Abstract:
The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and dat…
▽ More
The high-luminosity upgrade of the LHC brings unprecedented requirements for real-time and precision bunch-by-bunch online luminosity measurement and beam-induced background monitoring. A key component of the CMS Beam Radiation, Instrumentation and Luminosity system is a stand-alone luminometer, the Fast Beam Condition Monitor (FBCM), which is fully independent from the CMS central trigger and data acquisition services and able to operate at all times with a triggerless readout. FBCM utilizes a dedicated front-end application-specific integrated circuit (ASIC) to amplify the signals from CO$_2$-cooled silicon-pad sensors with a timing resolution of a few nanoseconds, which enables the measurement of the beam-induced background. FBCM uses a modular design with two half-disks of twelve modules at each end of CMS, with four service modules placed close to the outer edge to reduce radiation-induced aging. The electronics system design adapts several components from the CMS Tracker for power, control and read-out functionalities. The dedicated FBCM23 ASIC contains six channels and adjustable sha** time to optimize the noise with regards to sensor leakage current. Each ASIC channel outputs a single binary high-speed asynchronous signal carrying time-of-arrival and time-over-threshold information. The chip output signal is digitized, encoded and sent via a radiation-hard gigabit transceiver and an optical link to the back-end electronics for analysis. This paper reports on the updated design of the FBCM detector and the ongoing testing program.
△ Less
Submitted 6 February, 2024;
originally announced February 2024.
-
Study of depth-dependent charge collection profiles in irradiated pad diodes
Authors:
Mohammadtaghi Hajheidari,
Massimiliano Antonello,
Erika Garutti,
Robert Klanner,
Joern Schwandt,
Georg Steinbrueck
Abstract:
In this work, charge collection profiles of non-irradiated and irradiated 150 $μ$m $p$-type pad diodes were measured using a 5.2 GeV electron beam traversing the diode parallel to the readout electrode. Four diodes were irradiated to 1 MeV neutron equivalent fluences of 2, 4, 8, and 12E15 {cm}^{-2} with 23 MeV protons. The Charge Collection Efficiency profiles as a function of depth are extracted…
▽ More
In this work, charge collection profiles of non-irradiated and irradiated 150 $μ$m $p$-type pad diodes were measured using a 5.2 GeV electron beam traversing the diode parallel to the readout electrode. Four diodes were irradiated to 1 MeV neutron equivalent fluences of 2, 4, 8, and 12E15 {cm}^{-2} with 23 MeV protons. The Charge Collection Efficiency profiles as a function of depth are extracted by unfolding the data. The results of the measurements are compared to the simulation using three radiation damage models from literature which were tuned to different irradiation types and fluences.
△ Less
Submitted 23 January, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
Position reconstruction for segmented detectors
Authors:
A. Ebrahimi,
F. Feind,
E. Fretwurst,
E. Garutti,
M. Hajheidari,
R. Klanner,
D. Pitzl,
J. Schwandt,
G. Steinbrueck,
I. Zoi
Abstract:
The topic of the paper is the position reconstruction from signals of segmented detectors. With the help of a simple simulation, it is shown that the position reconstruction using the centre-of-gravity method is strongly biased, if the width of the charge (or e.g. light) distribution at the electrodes (or photo detectors) is less than the read-out pitch. A method is proposed which removes this bia…
▽ More
The topic of the paper is the position reconstruction from signals of segmented detectors. With the help of a simple simulation, it is shown that the position reconstruction using the centre-of-gravity method is strongly biased, if the width of the charge (or e.g. light) distribution at the electrodes (or photo detectors) is less than the read-out pitch. A method is proposed which removes this bias for events with signals in two or more read-out channels and thereby improves the position resolution. The method also provides an estimate of the position-response function for every event. Examples are given for which its width as a function of the reconstructed position varies by as much as an order of magnitude.
A fast Monte Carlo program is described which simulates the signals from a silicon pixel detector traversed by charged particles under different angles, and the results obtained with the proposed reconstruction method and with the centre-of-gravity method are compared. The simulation includes the local energy-loss fluctuations, the position-dependent electric field, the diffusion of the charge carriers, the electronics noise and charge thresholds for clustering. A comparison to test-beam-data is used to validate the simulation.
△ Less
Submitted 14 July, 2021;
originally announced July 2021.
-
Position resolution with 25 um pitch pixel sensors before and after irradiation
Authors:
I. Zoi,
A. Ebrahimi,
F. Feindt,
E. Garutti,
P. Gunnellini,
A. Hinzmann,
C. Niemeyer,
D. Pitzl,
J. Schwandt,
G. Steinbrück
Abstract:
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossin…
▽ More
Pixelated silicon detectors are state-of-the-art technology to achieve precise tracking and vertexing at collider experiments, designed to accurately measure the hit position of incoming particles in high rate and radiation environments. The detector requirements become extremely demanding for operation at the High-Luminosity LHC, where up to 200 interactions will overlap in the same bunch crossing on top of the process of interest. Additionally, fluences up to 2.3 10^16 cm^-2 1 MeV neutron equivalent at 3.0 cm distance from the beam are expected for an integrated luminosity of 3000 fb^-1. In the last decades, the pixel pitch has constantly been reduced to cope with the experiment's needs of achieving higher position resolution and maintaining low pixel occupancy per channel. The spatial resolution improves with a decreased pixel size but it degrades with radiation damage. Therefore, prototype sensor modules for the upgrade of the experiments at the HL-LHC need to be tested after being irradiated. This paper describes position resolution measurements on planar prototype sensors with 100x25 um^2 pixels for the CMS Phase-2 Upgrade. It reviews the dependence of the position resolution on the relative inclination angle between the incoming particle trajectory and the sensor, the charge threshold applied by the readout chip, and the bias voltage. A precision setup with three parallel planes of sensors has been used to investigate the performance of sensors irradiated to fluences up to F_eq = 3.6 10^15 cm-2. The measurements were performed with a 5 GeV electron beam. A spatial resolution of 3.2 +\- 0.1 um is found for non-irradiated sensors, at the optimal angle for charge sharing. The resolution is 5.0 +/- 0.2 um for a proton-irradiated sensor at F_eq = 2.1 10^15 cm-2 and a neutron-irradiated sensor at F_eq = 3.6 10^15 cm^-2.
△ Less
Submitted 9 July, 2021;
originally announced July 2021.
-
A new model for the TCAD simulation of the silicon damage by high fluence proton irradiation
Authors:
Joern Schwandt,
Eckhart Fretwurst,
Erika Garutti,
Robert Klanner,
Christian Scharf,
Georg Steinbrueck
Abstract:
For the high-luminosity phase of the Large Hadron Collider (HL-LHC), at the expected position of the innermost pixel detector layer of the CMS and ATLAS experiments, the estimated equivalent neutron fluence after 3000 fb$^{-1}$ is 2$\cdot$10$^{16}$ n$_{eq}$/cm$^2$, and the IEL (Ionizing Energy Loss) dose in the SiO$_2$ 12 MGy. The optimisation of the pixel sensors and the understanding of their pe…
▽ More
For the high-luminosity phase of the Large Hadron Collider (HL-LHC), at the expected position of the innermost pixel detector layer of the CMS and ATLAS experiments, the estimated equivalent neutron fluence after 3000 fb$^{-1}$ is 2$\cdot$10$^{16}$ n$_{eq}$/cm$^2$, and the IEL (Ionizing Energy Loss) dose in the SiO$_2$ 12 MGy. The optimisation of the pixel sensors and the understanding of their performance as a function of fluence and dose makes a radiation damage model for TCAD simulations, which describes the available experimental data, highly desirable. The currently available bulk-damage models are not able to describe simultaneously the measurements of dark current (I-V), capacitance-voltage (C-V) and charge collection efficiency (CCE) of pad diodes for fluences $\ge 1\cdot 10^{15}$ n$_{eq}$/cm$^2$. Therefore, for the development and validation of a new accurate bulk damage model we use I-V, C-V and CCE measurements on pad diodes available within the CMS-HPK campaign and data from samples irradiated recently with 24 GeV/c protons. For the determination of the radiation-induced damage parameters we utilise the "optimiser" of Synopsys TCAD, which allows the minimisation of the difference between the measured and simulated I-V, C-V and CCE. The outcome of this optimisation, the Hamburg Penta Trap Model (HPTM), provides a consistent and accurate description of the measurements of diodes irradiated with protons in the fluence range from 3$\cdot$10$^{14}$ n$_{eq}$/cm$^2$ to 1.3$\cdot$10$^{16}$ n$_{eq}$/cm$^2$.
△ Less
Submitted 23 April, 2019;
originally announced April 2019.
-
Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector
Authors:
M. Dragicevic,
M. Friedl,
J. Hrubec,
H. Steininger,
A. Gädda,
J. Härkönen,
T. Lampén,
P. Luukka,
T. Peltola,
E. Tuominen,
E. Tuovinen,
A. Winkler,
P. Eerola,
T. Tuuva,
G. Baulieu,
G. Boudoul,
L. Caponetto,
C. Combaret,
D. Contardo,
T. Dupasquier,
G. Gallbit,
N. Lumb,
L. Mirabito,
S. Perries,
M. Vander Donckt
, et al. (462 additional authors not shown)
Abstract:
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator…
▽ More
A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.
△ Less
Submitted 1 June, 2017;
originally announced June 2017.
-
Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC
Authors:
C. Barth,
C. A. Betancourt,
I. Bloch,
F. Bögelspacher,
W. de Boer,
M. Daniels,
A. Dierlamm,
R. Eber,
G. Eckerlin,
D. Eckstein,
T. Eichhorn,
J. Erfle,
L. Feld,
E. Garutti,
I. -M. Gregor,
M. Guthoff,
F. Hartmann,
M. Hauser,
U. Husemann,
K. Jakobs,
A. Junkes,
W. Karpinski,
K. Klein,
S. Kuehn,
H. Lacker
, et al. (16 additional authors not shown)
Abstract:
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an env…
▽ More
While the tracking detectors of the ATLAS and CMS experiments have shown excellent performance in Run 1 of LHC data taking, and are expected to continue to do so during LHC operation at design luminosity, both experiments will have to exchange their tracking systems when the LHC is upgraded to the high-luminosity LHC (HL-LHC) around the year 2024. The new tracking systems need to operate in an environment in which both the hit densities and the radiation damage will be about an order of magnitude higher than today. In addition, the new trackers need to contribute to the first level trigger in order to maintain a high data-taking efficiency for the interesting processes. Novel detector technologies have to be developed to meet these very challenging goals. The German groups active in the upgrades of the ATLAS and CMS tracking systems have formed a collaborative "Project on Enabling Technologies for Silicon Microstrip Tracking Detectors at the HL-LHC" (PETTL), which was supported by the Helmholtz Alliance "Physics at the Terascale" during the years 2013 and 2014. The aim of the project was to share experience and to work together on key areas of mutual interest during the R&D phase of these upgrades. The project concentrated on five areas, namely exchange of experience, radiation hardness of silicon sensors, low mass system design, automated precision assembly procedures, and irradiations. This report summarizes the main achievements.
△ Less
Submitted 28 April, 2016;
originally announced April 2016.
-
Trap** in irradiated p-on-n silicon sensors at fluences anticipated at the HL-LHC outer tracker
Authors:
W. Adam,
T. Bergauer,
M. Dragicevic,
M. Friedl,
R. Fruehwirth,
M. Hoch,
J. Hrubec,
M. Krammer,
W. Treberspurg,
W. Waltenberger,
S. Alderweireldt,
W. Beaumont,
X. Janssen,
S. Luyckx,
P. Van Mechelen,
N. Van Remortel,
A. Van Spilbeeck,
P. Barria,
C. Caillol,
B. Clerbaux,
G. De Lentdecker,
D. Dobur,
L. Favart,
A. Grebenyuk,
Th. Lenzi
, et al. (663 additional authors not shown)
Abstract:
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determi…
▽ More
The degradation of signal in silicon sensors is studied under conditions expected at the CERN High-Luminosity LHC. 200 $μ$m thick n-type silicon sensors are irradiated with protons of different energies to fluences of up to $3 \cdot 10^{15}$ neq/cm$^2$. Pulsed red laser light with a wavelength of 672 nm is used to generate electron-hole pairs in the sensors. The induced signals are used to determine the charge collection efficiencies separately for electrons and holes drifting through the sensor. The effective trap** rates are extracted by comparing the results to simulation. The electric field is simulated using Synopsys device simulation assuming two effective defects. The generation and drift of charge carriers are simulated in an independent simulation based on PixelAV. The effective trap** rates are determined from the measured charge collection efficiencies and the simulated and measured time-resolved current pulses are compared. The effective trap** rates determined for both electrons and holes are about 50% smaller than those obtained using standard extrapolations of studies at low fluences and suggests an improved tracker performance over initial expectations.
△ Less
Submitted 7 May, 2015;
originally announced May 2015.
-
Observation of the rare $B^0_s\toμ^+μ^-$ decay from the combined analysis of CMS and LHCb data
Authors:
The CMS,
LHCb Collaborations,
:,
V. Khachatryan,
A. M. Sirunyan,
A. Tumasyan,
W. Adam,
T. Bergauer,
M. Dragicevic,
J. Erö,
M. Friedl,
R. Frühwirth,
V. M. Ghete,
C. Hartl,
N. Hörmann,
J. Hrubec,
M. Jeitler,
W. Kiesenhofer,
V. Knünz,
M. Krammer,
I. Krätschmer,
D. Liko,
I. Mikulec,
D. Rabady,
B. Rahbaran
, et al. (2807 additional authors not shown)
Abstract:
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six sta…
▽ More
A joint measurement is presented of the branching fractions $B^0_s\toμ^+μ^-$ and $B^0\toμ^+μ^-$ in proton-proton collisions at the LHC by the CMS and LHCb experiments. The data samples were collected in 2011 at a centre-of-mass energy of 7 TeV, and in 2012 at 8 TeV. The combined analysis produces the first observation of the $B^0_s\toμ^+μ^-$ decay, with a statistical significance exceeding six standard deviations, and the best measurement of its branching fraction so far. Furthermore, evidence for the $B^0\toμ^+μ^-$ decay is obtained with a statistical significance of three standard deviations. The branching fraction measurements are statistically compatible with SM predictions and impose stringent constraints on several theories beyond the SM.
△ Less
Submitted 17 August, 2015; v1 submitted 17 November, 2014;
originally announced November 2014.
-
The D0 Silicon Microstrip Tracker
Authors:
S. N. Ahmed,
R. Angstadt,
M. Aoki,
B. Åsman,
S. Austin,
L. Bagby,
E. Barberis,
P. Baringer,
A. Bean,
A. Bischoff,
F. Blekman,
T. A. Bolton,
C. Boswell,
M. Bowden,
F. Browning,
D. Buchholz,
S. Burdin,
D. Butler,
H. Cease,
S. Choi,
A. R. Clark,
J. Clutter,
A. Cooper,
W. E. Cooper,
M. Corcoran
, et al. (109 additional authors not shown)
Abstract:
This paper describes the mechanical design, the readout chain, the production, testing and the installation of the Silicon Microstrip Tracker of the D0 experiment at the Fermilab Tevatron collider. In addition, description of the performance of the detector during the experiment data collection between 2001 and 2010 is provided.
This paper describes the mechanical design, the readout chain, the production, testing and the installation of the Silicon Microstrip Tracker of the D0 experiment at the Fermilab Tevatron collider. In addition, description of the performance of the detector during the experiment data collection between 2001 and 2010 is provided.
△ Less
Submitted 5 May, 2010;
originally announced May 2010.
-
The D0 Run II Impact Parameter Trigger
Authors:
T. Adams,
Q. An,
K. M. Black,
T. Bose,
N. J. Buchanan,
S. Caron,
D. K. Cho,
S. Choi,
A. Das,
M. Das,
H. Dong,
W. Earle,
H. Evans,
S. N. Fatakia,
L. Feligioni,
T. Fitzpatrick,
E. Hazen,
U. Heintz,
K. Herner,
J. D. Hobbs,
D. Khatidze,
W. M. Lee,
S. L. Linn,
M. Narain,
C. Pancake
, et al. (18 additional authors not shown)
Abstract:
Many physics topics to be studied by the D0 experiment during Run II of the Fermilab Tevatron ppbar collider give rise to final states containing b--flavored particles. Examples include Higgs searches, top quark production and decay studies, and full reconstruction of B decays. The sensitivity to such modes has been significantly enhanced by the installation of a silicon based vertex detector as…
▽ More
Many physics topics to be studied by the D0 experiment during Run II of the Fermilab Tevatron ppbar collider give rise to final states containing b--flavored particles. Examples include Higgs searches, top quark production and decay studies, and full reconstruction of B decays. The sensitivity to such modes has been significantly enhanced by the installation of a silicon based vertex detector as part of the DO detector upgrade for Run II. Interesting events must be identified initially in 100-200 microseconds to be available for later study. This paper describes custom electronics used in the DO trigger system to provide the real--time identification of events having tracks consistent with the decay of b--flavored particles.
△ Less
Submitted 17 January, 2007;
originally announced January 2007.
-
Report of the Working Group on Photon and Weak Boson Production
Authors:
U. Baur,
E. L. Berger,
H. T. Diehl,
D. Errede,
D. Casey,
T. Dorigo,
J. Huston,
J. Owens,
J. Womersley,
L. Apanasevich,
M. Begel,
Y. Gershtein,
M. Kelly,
S. Kuhlmann,
S. Leone,
D. Partos,
D. Rainwater,
W. Sakumoto,
G. Steinbruck,
M. Zielinski,
V. Zutshi
Abstract:
This report discusses physics issues which can be addressed in photon and weak boson production in Run II at the Tevatron. The current understanding and the potential of Run II to expand our knowledge of direct photon production in hadronic collisions is discussed. We explore the prospects for using the W-boson cross section to measure the integrated luminosity, improving the measurement of the…
▽ More
This report discusses physics issues which can be addressed in photon and weak boson production in Run II at the Tevatron. The current understanding and the potential of Run II to expand our knowledge of direct photon production in hadronic collisions is discussed. We explore the prospects for using the W-boson cross section to measure the integrated luminosity, improving the measurement of the W and Z boson transverse momentum distributions, the Z -> b\bar b signal, and the lepton angular distribution in W decays. Finally, we consider the prospects for measuring the trilinear gauge boson couplings in Run II.
△ Less
Submitted 2 November, 2000; v1 submitted 22 May, 2000;
originally announced May 2000.