Skip to main content

Showing 1–3 of 3 results for author: Stefania, S

.
  1. arXiv:2405.19021  [pdf

    astro-ph.IM astro-ph.EP physics.ins-det

    Calibration of MAJIS (Moons And Jupiter Imaging Spectrometer): III. Spectral Calibration

    Authors: Paolo Haffoud, François Poulet, Mathieu Vincendon, Gianrico Filacchione, Alessandra Barbis, Pierre Guiot, Benoit Lecomte, Yves Langevin, Giuseppe Piccioni, Cydalise Dumesnil, Sébastien Rodriguez, John Carter, Stefani Stefania, Leonardo Tommasi, Federico Tosi, Cédric Pilorget

    Abstract: The Moons And Jupiter Imaging Spectrometer (MAJIS) is the visible and near-infrared imaging spectrometer onboard ESA s Jupiter Icy Moons Explorer (JUICE) mission. Before its integration into the spacecraft, the instrument undergoes an extensive ground calibration to establish its baseline performances. This process prepares the imaging spectrometer for flight operations by characterizing the behav… ▽ More

    Submitted 29 May, 2024; originally announced May 2024.

    Journal ref: Rev. Sci. Instrum. 95, 031301 (2024)

  2. Quasar feedback in the early Universe: the case of SDSS J1148+5251

    Authors: Rosa Valiante, Raffaella Schneider, Roberto Maiolino, Salvadori Stefania, Bianchi Simone

    Abstract: Galaxy-scale gas outflows triggered by active galactic nuclei have been proposed as a key physical process to regulate the co-evolution of nuclear black holes and their host galaxies. The recent detection of a massive gas outflow in one of the most distant quasar, SDSS J1148+5251 at z = 6.4, presented by Maiolino et al. (2012) strongly supports this idea and suggests that strong quasar feedback is… ▽ More

    Submitted 3 September, 2012; v1 submitted 15 May, 2012; originally announced May 2012.

    Comments: 5 pages, 4 figures, accepted for publication in MNRAS Letters

  3. The first $R_{cr}$ as a possible measure of the entrainment length in a 2D steady wake

    Authors: Tordella Daniela, Scarsoglio Stefania

    Abstract: At a fixed distance from the body which creates the wake, entrainment is only seen to increase with the Reynolds number ($R$) up to a distance of almost 20 body scales. This increase levels up to a Reynolds number close to the critical value for the onset of the first instability. The entrainment is observed to be almost extinguished at a distance which is nearly the same for all the steady wake… ▽ More

    Submitted 1 July, 2009; v1 submitted 31 May, 2008; originally announced June 2008.

    Journal ref: Physics Letters A, Vol. 373 (12-13), pages 1159-1164 (2009)