-
Logical coherence in 2D compass codes
Authors:
Balint Pato,
Judd Will Staples Jr.,
Kenneth R. Brown
Abstract:
2D compass codes are a family of quantum error-correcting codes that contain the Bacon-Shor codes, the X-Shor and Z-Shor codes, and the rotated surface codes. Previous numerical results suggest that the surface code has a constant accuracy and coherence threshold under uniform coherent rotation. However, having analytical proof supporting a constant threshold is still an open problem. It is analyt…
▽ More
2D compass codes are a family of quantum error-correcting codes that contain the Bacon-Shor codes, the X-Shor and Z-Shor codes, and the rotated surface codes. Previous numerical results suggest that the surface code has a constant accuracy and coherence threshold under uniform coherent rotation. However, having analytical proof supporting a constant threshold is still an open problem. It is analytically proven that the toric code can exponentially suppress logical coherence in the code distance $L$. However, the current analytical lower bound on the threshold for the rotation angle $θ$ is $|\sin(θ)| < 1/L$, which linearly vanishes in $L$ instead of being constant. We show that this lower bound is achievable by the Z-Shor code which does not have a threshold under stochastic noise. Compass codes provide a promising direction to improve on the previous bounds. We analytically determine thresholds for two new compass code families with thresholds near the rotated surface code's numerically established coherence threshold. Furthermore, using a Majorana mode-based simulator, we use random families of compass codes to smoothly interpolate between the Z-Shor codes and the X-Shor codes.
△ Less
Submitted 15 May, 2024;
originally announced May 2024.
-
Universal flux-based control of a $π$-SQUID
Authors:
J. Wilson Staples,
Thomas B. Smith,
Andrew C. Doherty
Abstract:
We describe a protocol for the universal control of non-ideal $π$-periodic superconducting qubits. Our proposal relies on a $π$-SQUID: a superconducting loop formed by two $π$-periodic circuit elements, with an external magnetic flux threading the circuit. The system exhibits an extensive sweet spot around half-flux where residual $2π$-periodic Cooper pair tunneling is highly suppressed. We demons…
▽ More
We describe a protocol for the universal control of non-ideal $π$-periodic superconducting qubits. Our proposal relies on a $π$-SQUID: a superconducting loop formed by two $π$-periodic circuit elements, with an external magnetic flux threading the circuit. The system exhibits an extensive sweet spot around half-flux where residual $2π$-periodic Cooper pair tunneling is highly suppressed. We demonstrate that universal single-qubit operations can be realised by tuning the flux adiabatically and diabatically within this broad sweet spot. We also assess how residual $2π$-periodicity in $π$-SQUIDs impacts holonomic phase gates.
△ Less
Submitted 26 February, 2024; v1 submitted 7 December, 2023;
originally announced December 2023.
-
Extraordinary Phase Coherence Length in Epitaxial Halide Perovskites
Authors:
K. Nasyedkin,
I. King,
L. Zhang,
P. Chen,
L. Wang,
R. J. Staples,
R. R. Lunt,
J. Pollanen
Abstract:
Inorganic halide perovskites have emerged as a promising platform in a wide range of applications from solar energy harvesting to computing, and light emission. The recent advent of epitaxial thin film growth of halide perovskites has made it possible to investigate low-dimensional quantum electronic devices based on this class of materials. This study leverages advances in vapor-phase epitaxy of…
▽ More
Inorganic halide perovskites have emerged as a promising platform in a wide range of applications from solar energy harvesting to computing, and light emission. The recent advent of epitaxial thin film growth of halide perovskites has made it possible to investigate low-dimensional quantum electronic devices based on this class of materials. This study leverages advances in vapor-phase epitaxy of halide perovskites to perform low-temperature magnetotransport measurements on single-domain cesium tin iodide (CsSnI$_3$) epitaxial thin films. The low-field magnetoresistance carries signatures of coherent quantum interference effects and spin-orbit coupling. These weak anti-localization measurements reveal a micron-scale low-temperature phase coherence length for charge carriers in this system. The results indicate that epitaxial halide perovskite heterostructures are a promising platform for investigating long coherent quantum electronic effects and potential applications in spintronics and spin-orbitronics.
△ Less
Submitted 12 August, 2021; v1 submitted 10 September, 2020;
originally announced September 2020.
-
RF design of APEX2 two-cell continuous-wave normal conducting photoelectron gun cavity based on multi-objective genetic algorithm
Authors:
T. Luo,
H. Feng,
D. Filippetto,
M. Johnson,
A. Lambert,
D. Li,
C. Mitchell,
F. Sannibale,
J. Staples,
S. Virostek,
R. Wells
Abstract:
High brightness, high repetition rate electron beams are key components for optimizing the performance of next generation scientific instruments, such as MHz-class X-ray Free Electron Laser (XFEL) and Ultra-fast Electron Diffraction/Microscopy (UED/UEM). In the Advanced Photo-injector EXperiment (APEX) at Berkeley Lab, a photoelectron gun based on a 185.7 MHz normal conducting re-entrant RF cavity…
▽ More
High brightness, high repetition rate electron beams are key components for optimizing the performance of next generation scientific instruments, such as MHz-class X-ray Free Electron Laser (XFEL) and Ultra-fast Electron Diffraction/Microscopy (UED/UEM). In the Advanced Photo-injector EXperiment (APEX) at Berkeley Lab, a photoelectron gun based on a 185.7 MHz normal conducting re-entrant RF cavity, has been proven to be a feasible solution to provide high brightness, high repetition rate electron beam for both XFEL and UED/UEM. Based on the success of APEX, a new electron gun system, named APEX2, has been under development to further improve the electron beam brightness. For APEX2, we have designed a new 162.5 MHz two-cell photoelectron gun and achieved a significant increase on the cathode launching field and the beam exit energy. For a fixed charge per bunch, these improvements will allow for the emittance reduction and hence an increased beam brightness. The design of APEX2 gun cavity is a complex problem with multiple design goals and restrictions, some even competing each other. For a systematic and comprehensive search for the optimized cavity geometry, we have developed and implemented a novel optimization method based on the Multi-Objective Genetic Algorithm (MOGA).
△ Less
Submitted 28 May, 2019; v1 submitted 25 May, 2019;
originally announced May 2019.
-
SNS Front End Diagnostics
Authors:
L. Doolittle,
T. Goulding,
D. Oshatz,
A. Ratti,
J. Staples
Abstract:
The Front End of the Spallation Neutron Source (SNS) extends from the Ion Source (IS), through a 65 keV LEBT, a 402.5 MHz RFQ, a 2.5 MeV MEBT, ending at the entrance to the DTL. The diagnostics suite in this space includes stripline beam position and phase monitors (BPM), toroid beam current monitors (BCM), and an emittance scanner. Provision is included for beam profile measurement, either gas…
▽ More
The Front End of the Spallation Neutron Source (SNS) extends from the Ion Source (IS), through a 65 keV LEBT, a 402.5 MHz RFQ, a 2.5 MeV MEBT, ending at the entrance to the DTL. The diagnostics suite in this space includes stripline beam position and phase monitors (BPM), toroid beam current monitors (BCM), and an emittance scanner. Provision is included for beam profile measurement, either gas fluorescence, laser-based photodissociation, or a crawling wire. Mechanical and electrical design and prototy** of BPM and BCM subsystems are proceeding. Significant effort has been devoted to packaging the diagnostic devices in minimal space. Close ties are maintained to the rest of the SNS effort, to ensure long term compatibility of interfaces and in fact share some design work and construction. The data acquisition, digital processing, and control system interface needs for the BPM, BCM, and LEBT diagnostic are similar, and we are committed to using an architecture common with the rest of the SNS collaboration.
△ Less
Submitted 23 August, 2000;
originally announced August 2000.
-
Analysis of Thermally Induced Frequency Shift for the Spallation Neutron Source RFQ
Authors:
S. Virostek,
J. Staples
Abstract:
The Spallation Neutron Source (SNS) Front-End Systems Group at Lawrence Berkeley National Lab (LBNL) is develo** a Radio Frequency Quadrupole (RFQ) to accelerate an H- beam from 65 keV to 2.5 MeV at the operating frequency of 402.5 MHz. The 4 section, 3.7 meter long RFQ is a 4 vane structure operating at 6% duty factor. The cavity walls are made from OFE Copper with a GlidCop outer layer to ad…
▽ More
The Spallation Neutron Source (SNS) Front-End Systems Group at Lawrence Berkeley National Lab (LBNL) is develo** a Radio Frequency Quadrupole (RFQ) to accelerate an H- beam from 65 keV to 2.5 MeV at the operating frequency of 402.5 MHz. The 4 section, 3.7 meter long RFQ is a 4 vane structure operating at 6% duty factor. The cavity walls are made from OFE Copper with a GlidCop outer layer to add mechanical strength. A set of 12 cooling channels in the RFQ cavity walls are fed and controlled separately from 4 channels embedded in the vanes. An ANSYS finite-element model has been developed to calculate the deformed shape of the cavity for given RF heat loads and cooling water temperatures. By combining the FEA results with a SUPERFISH RF cavity simulation, the relative shift in frequency for a given change in coolant temperature or heat load can be predicted. The calculated cavity frequency sensitivity is -33 kHz per 1 degC change in vane water temperature with constant-temperature wall water. The system start-up transient was also studied using the previously mentioned FEA model. By controlling the RF power ramp rate and the independent wall and vane cooling circuit temperatures, the system turn-on time can be minimized while limiting the frequency shift.
△ Less
Submitted 18 August, 2000;
originally announced August 2000.