Time-efficient, High Resolution 3T Whole Brain Quantitative Relaxometry using 3D-QALAS with Wave-CAIPI Readouts
Authors:
Jae** Cho,
Borjan Gagoski,
Tae Hyung Kim,
Fuyixue Wang,
Daniel Nico Splitthoff,
Wei-Ching Lo,
Wei Liu,
Daniel Polak,
Stephen Cauley,
Kawin Setsompop,
P. Ellen Grant,
Berkin Bilgic
Abstract:
Purpose: Volumetric, high-resolution, quantitative map** of brain tissue relaxation properties is hindered by long acquisition times and signal-to-noise (SNR) challenges. This study, for the first time, combines the time-efficient wave-CAIPI readouts into the 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) acquisition scheme, enablin…
▽ More
Purpose: Volumetric, high-resolution, quantitative map** of brain tissue relaxation properties is hindered by long acquisition times and signal-to-noise (SNR) challenges. This study, for the first time, combines the time-efficient wave-CAIPI readouts into the 3D-quantification using an interleaved Look-Locker acquisition sequence with a T2 preparation pulse (3D-QALAS) acquisition scheme, enabling full brain quantitative T1, T2 and proton density (PD) maps at 1.15 mm3 isotropic voxels in only 3 minutes. Methods: Wave-CAIPI readouts were embedded in the standard 3D-QALAS encoding scheme, enabling full brain quantitative parameter maps (T1, T2, and PD) at acceleration factors of R=3x2 with minimum SNR loss due to g-factor penalties. The quantitative parameter maps were estimated using a dictionary-based map** algorithm incorporating inversion efficiency and B1 field inhomogeneity. The quantitative maps using the accelerated protocol were quantitatively compared against those obtained from conventional 3D-QALAS sequence using GRAPPA acceleration of R=2 in the ISMRM NIST phantom, and ten healthy volunteers. Results: When tested in both the ISMRM/NIST phantom and ten healthy volunteers, the quantitative maps using the accelerated protocol showed excellent agreement against those obtained from conventional 3D-QALAS at RGRAPPA=2. Conclusion: 3D-QALAS enhanced with wave-CAIPI readouts enables time-efficient, full brain quantitative T1, T2, and PD map** at 1.15 mm3 in 3 minutes at R=3x2 acceleration. When tested on the NIST phantom and ten healthy volunteers, the quantitative maps obtained from the accelerated wave-CAIPI 3D-QALAS protocol showed very similar values to those obtained from the standard 3D-QALAS (R=2) protocol, alluding to the robustness and reliability of the proposed methods.
△ Less
Submitted 27 January, 2023; v1 submitted 8 November, 2022;
originally announced November 2022.