Magnetometry with spin polarized Hydrogen from molecular photo-dissociation
Authors:
Konstantinos Tazes,
Alexandros K. Spiliotis,
Michalis Xygkis,
George E. Katsoprinakis,
T. Peter Rakitzis,
Georgios Vasilakis
Abstract:
In a recent publication [arXiv:2010.14579], we introduced a new type of atomic magnetometer, which relies on hydrohalide photo-dissociation to create high-density spin-polarized hydrogen. Here, we extend our previous work and present a detailed theoretical analysis of the magnetometer signal and its dependence on time. We also derive the sensitivity for a spin-projection noise limited magnetometer…
▽ More
In a recent publication [arXiv:2010.14579], we introduced a new type of atomic magnetometer, which relies on hydrohalide photo-dissociation to create high-density spin-polarized hydrogen. Here, we extend our previous work and present a detailed theoretical analysis of the magnetometer signal and its dependence on time. We also derive the sensitivity for a spin-projection noise limited magnetometer, which can be applied to an arbitrary magnetic field waveform.
△ Less
Submitted 12 February, 2021;
originally announced February 2021.
-
Depolarization of Spin-Polarized Hydrogen via Collisions with Chlorine Atoms at Ultrahigh Density
Authors:
Alexandros K. Spiliotis,
Michail Xygkis,
Michail E. Koutrakis,
Dimitrios Sofikitis,
T. Peter Rakitzis
Abstract:
Recently, the production of ultrahigh-density (~10^{19}cm^{-3}) spin-polarized deuterium (SPD) atoms was demonstrated, from the photodissociation of deuterium iodide, but the upper density limit was not determined. Here, we present studies of spin-polarized hydrogen (SPH) densities up to 10^{20} cm^{-3}, by photodissociating 5 bar of hydrogen chloride with a focused 213 nm, 150 ps laser pulse. We…
▽ More
Recently, the production of ultrahigh-density (~10^{19}cm^{-3}) spin-polarized deuterium (SPD) atoms was demonstrated, from the photodissociation of deuterium iodide, but the upper density limit was not determined. Here, we present studies of spin-polarized hydrogen (SPH) densities up to 10^{20} cm^{-3}, by photodissociating 5 bar of hydrogen chloride with a focused 213 nm, 150 ps laser pulse. We extract the depolarization cross-section of hydrogen and chlorine atom collisions, which is the main depolarization mechanism at this high-density regime, to be σ_{HCl} = 7(2) x 10^{-17}cm^2. We discuss the conditions under which the ultrahigh SPH and SPD densities can be reached, and the potential applications to ultrafast magnetometry, laser-ion acceleration, and tests of polarized nuclear fusion.
△ Less
Submitted 19 April, 2021; v1 submitted 7 January, 2021;
originally announced January 2021.
-
A Nanosecond-Resolved Atomic Hydrogen Magnetometer
Authors:
Alexandros K. Spiliotis,
Michalis Xygkis,
Konstantinos Tazes,
George E. Katsoprinakis,
Georgios Vasilakis,
T. Peter Rakitzis
Abstract:
Spin polarized atomic ensembles can be used for the precise measurement of magnetic field. Conventional atomic magnetometers have demonstrated high sensitivities, albeit at low detection bandwidth, fundamentally limited by the Larmor precession frequency of the atoms. Here, we introduce a new type of atomic magnetometer which can realize sensitive detection with high temporal resolution. The magne…
▽ More
Spin polarized atomic ensembles can be used for the precise measurement of magnetic field. Conventional atomic magnetometers have demonstrated high sensitivities, albeit at low detection bandwidth, fundamentally limited by the Larmor precession frequency of the atoms. Here, we introduce a new type of atomic magnetometer which can realize sensitive detection with high temporal resolution. The magnetometer is based on monitoring the effect of the magnetic field on the hyperfine coherences of spin-polarized hydrogen atoms produced from the rapid photodissociation of hydrogen chloride (HCl). This scheme extends the magnetic measurement bandwidth to an upper frequency limit set by the hyperfine interaction. The use of HCl as the source for polarized atoms allows for large spin densities in the range of $10^{19}$ - $10^{20} cm^{-3}$, many orders of magnitude higher than those achieved with conventional alkali-atomic magnetometers. A spin-projection noise-limited magnetometer smaller than 100 μm can detect with nanosecond temporal resolution a magnetic field as low as 1 nT. This novel magnetometer opens new possibilities for precise measurement of ultrafast magnetic fields, with applications in biology, surface science and chemistry.
△ Less
Submitted 29 April, 2021; v1 submitted 27 October, 2020;
originally announced October 2020.
-
Evanescent-wave and open-air chiral sensing via signal-reversing cavity-enhanced polarimetry
Authors:
Dimitris Sofikitis,
Lykourgos Bougas,
Georgios E. Katsoprinakis,
Alexandros K. Spiliotis,
Benoit Loppinet,
T. Peter Rakitzis
Abstract:
Sensing chirality is of fundamental importance to many fields, including analytical and biological chemistry, pharmacology, and fundamental physics. Recent developments have extended optical chiral sensing using microwaves, fs pulses, superchiral light, and photoionization. The most widely used methods are the traditional methods of circular dichroism and optical rotation (OR). However, chiral sig…
▽ More
Sensing chirality is of fundamental importance to many fields, including analytical and biological chemistry, pharmacology, and fundamental physics. Recent developments have extended optical chiral sensing using microwaves, fs pulses, superchiral light, and photoionization. The most widely used methods are the traditional methods of circular dichroism and optical rotation (OR). However, chiral signals are typically very weak, and their measurement is limited by larger time-dependent backgrounds and by imperfect and slow subtraction procedures. Here, we demonstrate a pulsed-laser bowtie-cavity-enhanced polarimeter with counter-propagating beams, which solves these background problems: the chiral signals are enhanced by the number of cavity passes; the effects of linear birefringence are suppressed by a large induced intracavity Faraday rotation; and rapid signal reversals are effected by reversing the Faraday rotation and subtracting signals from the counter-propagating beams. These advantages allow measurements of absolute chiral signals in environments where background subtractions are not feasible: we measure optical rotation from chiral vapour in open air, and from chiral liquids in the evanescent wave (EW) produced by total internal reflection at a prism surface. EW-OR of (+)-maltodextrin and (-)-fructose solutions confirm the Drude-Condon model for Maxwell's equations in isotropic optically active media. In particular, the effective optical rotation path length, near index matching, is equal to the Goos-Hänchen shift of the EW. The limits of this polarimeter, when using a continuous-wave laser locked to a stable high-finesse cavity, should match sensitivity measurements for linear birefringence ($3\times 10^{-13}$ rad), which is several orders of magnitude more sensitive than current chiral detection limits, transforming the power of chiral sensing in many fields.
△ Less
Submitted 27 May, 2014;
originally announced May 2014.