Long-term stabilization of carrier envelope phases of mid-infrared pulses for the precise detection of phase-sensitive responses to electromagnetic waves
Authors:
T. Yamakawa,
N. Sono,
T. Kitao,
T. Morimoto,
N. Kida,
T. Miyamoto,
H. Okamoto
Abstract:
We report a newly designed mid-infrared-pump visible-probe measurement system, which can measure phase-sensitive responses to a mid-infrared pulse along the oscillating electromagnetic field. In this system, the pump light is a phase-locked mid-infrared pulse with temporal width of 100 fs, which is produced via difference frequency generation (DFG) from two idler pulses of two optical parametric a…
▽ More
We report a newly designed mid-infrared-pump visible-probe measurement system, which can measure phase-sensitive responses to a mid-infrared pulse along the oscillating electromagnetic field. In this system, the pump light is a phase-locked mid-infrared pulse with temporal width of 100 fs, which is produced via difference frequency generation (DFG) from two idler pulses of two optical parametric amplifiers (OPAs) that are excited by the same Ti:sapphire regenerative amplifier. The probe pulse is a visible pulse with temporal width of 9 fs, and it is generated from a custom-built non-collinear OPA. By measuring the electric-field waveforms of mid-infrared pump pulses with electro-optic sampling and evaluating their carrier envelope phase (CEP) and the temporal positions of their envelopes relative to ultrashort visible probe pulses, we are able to perform double feedback corrections that eliminate both the following sources of drift. The CEP drift in mid-infrared pulses originating from fluctuations in the difference of optical-path lengths of the two idler pulses before the DFG is corrected by inserting a wedge plate in one idler path, and the drift in pump-probe delay times due to fluctuations in the difference of the overall optical-path lengths of the pump and probe pulses is corrected with mechanical delay lines. In this double-feedback system, the absolute carrier phase of mid-infrared pulses can be fixed within 200 mrad and errors in the measurement of phase-sensitive responses can be reduced to within 1 fs over a few tens of hours.
△ Less
Submitted 4 September, 2019;
originally announced September 2019.
Probing ultrafast spin-relaxation and precession dynamics in a cuprate Mott insulator with 7-fs optical pulses
Authors:
T. Miyamoto,
Y. Matsui,
T. Terashige,
T. Morimoto,
N. Sono,
H. Yada,
S. Ishihara,
Y. Watanabe,
S. Adachi,
T. Ito,
K. Oka,
A. Sawa,
H. Okamoto
Abstract:
A charge excitation in a two-dimensional Mott insulator is strongly coupled with the surrounding spins, which is observed as magnetic-polaron formations of doped carriers and a magnon sideband in the Mott-gap transition spectrum. However, the dynamics related to the spin sector are difficult to measure. Here, we show that pump-probe reflection spectroscopy with 7-fs laser pulses can detect the opt…
▽ More
A charge excitation in a two-dimensional Mott insulator is strongly coupled with the surrounding spins, which is observed as magnetic-polaron formations of doped carriers and a magnon sideband in the Mott-gap transition spectrum. However, the dynamics related to the spin sector are difficult to measure. Here, we show that pump-probe reflection spectroscopy with 7-fs laser pulses can detect the optically induced spin dynamics in Nd$_2$CuO$_4$, a cuprate Mott insulator. The bleaching signal at the Mott-gap transition is enhanced at $\sim$18 fs, which corresponds to the spin-relaxation time in magnetic-polaron formations and is characterized by the exchange interaction. More importantly, ultrafast coherent oscillations appear in the time evolutions of the reflectivity changes, and their frequencies (1400-2700 cm$^{-1}$) are equal to the probe energy measured from the Mott-gap transition peak. These oscillations originate from interferences between charge excitations with two magnons and provide direct evidence for charge-spin coupling.
△ Less
Submitted 12 March, 2018;
originally announced March 2018.