-
Automatic registration with continuous pose updates for marker-less surgical navigation in spine surgery
Authors:
Florentin Liebmann,
Marco von Atzigen,
Dominik Stütz,
Julian Wolf,
Lukas Zingg,
Daniel Suter,
Laura Leoty,
Hooman Esfandiari,
Jess G. Snedeker,
Martin R. Oswald,
Marc Pollefeys,
Mazda Farshad,
Philipp Fürnstahl
Abstract:
Established surgical navigation systems for pedicle screw placement have been proven to be accurate, but still reveal limitations in registration or surgical guidance. Registration of preoperative data to the intraoperative anatomy remains a time-consuming, error-prone task that includes exposure to harmful radiation. Surgical guidance through conventional displays has well-known drawbacks, as inf…
▽ More
Established surgical navigation systems for pedicle screw placement have been proven to be accurate, but still reveal limitations in registration or surgical guidance. Registration of preoperative data to the intraoperative anatomy remains a time-consuming, error-prone task that includes exposure to harmful radiation. Surgical guidance through conventional displays has well-known drawbacks, as information cannot be presented in-situ and from the surgeon's perspective. Consequently, radiation-free and more automatic registration methods with subsequent surgeon-centric navigation feedback are desirable. In this work, we present an approach that automatically solves the registration problem for lumbar spinal fusion surgery in a radiation-free manner. A deep neural network was trained to segment the lumbar spine and simultaneously predict its orientation, yielding an initial pose for preoperative models, which then is refined for each vertebra individually and updated in real-time with GPU acceleration while handling surgeon occlusions. An intuitive surgical guidance is provided thanks to the integration into an augmented reality based navigation system. The registration method was verified on a public dataset with a mean of 96\% successful registrations, a target registration error of 2.73 mm, a screw trajectory error of 1.79° and a screw entry point error of 2.43 mm. Additionally, the whole pipeline was validated in an ex-vivo surgery, yielding a 100\% screw accuracy and a registration accuracy of 1.20 mm. Our results meet clinical demands and emphasize the potential of RGB-D data for fully automatic registration approaches in combination with augmented reality guidance.
△ Less
Submitted 5 August, 2023;
originally announced August 2023.
-
Measuring and simulating the biophysical basis of the acoustic contrast factor of biological cells
Authors:
Cooper Lars Harshbarger,
Alen Pavlic,
Davide Cesare Bernardoni,
Amelie Viol,
Jess Gerrit Snedeker,
Jürg Dual,
Unai Silván
Abstract:
The acoustic contrast factor (ACF) is calculated from the relative density and compressibility differences between a fluid and an object in the fluid. To name but one application, this acoustic contrast can be exploited using acoustophoretic systems to isolate cancer cells from a liquid biopsy, such as a blood sample. Knowing the ACF of a cancer cell represents a crucial step in the design of acou…
▽ More
The acoustic contrast factor (ACF) is calculated from the relative density and compressibility differences between a fluid and an object in the fluid. To name but one application, this acoustic contrast can be exploited using acoustophoretic systems to isolate cancer cells from a liquid biopsy, such as a blood sample. Knowing the ACF of a cancer cell represents a crucial step in the design of acoustophoretic systems for this purpose, potentially allowing the isolation of circulating cancer cells without labels or contact. For biological cells the static compressibility is different from the high frequency counterpart relevant for the ACF. In this study, we started by characterizing the ACF of low vs. high metastatic cell lines with known associated differences in phenotypic static E-modulus. The change in the static E-modulus, however, was not reflected in a change of the ACF, prompting a more in depth analysis of the influences on the ACF. We demonstrate that static E-modulus increased biological cells through formaldehyde fixation have an increased ACF. Conversely static E-modulus decreased biological cells treated with actin polymerization inhibitor cytochalasin D have a decreased ACF. Complementing these mechanical tests, a numerical COMSOL model was implemented and used to parametrically explore the effects of cell density, cell density ratios, dynamic compressibility and therefore the dynamic bulk modulus. Collectively the combined laboratory and numerical experiments reveal that a change in the static E-modulus alone might, but does not automatically lead to a change of the dynamic ACF for biological cells. This highlights the need for a multiparametic view of the biophysical basis of the cellular ACF, as well as the challenges in harnessing acoustophoretic systems to isolate circulating cells based on their mechanical properties alone.
△ Less
Submitted 10 January, 2023;
originally announced January 2023.
-
Sharp-edge-based acoustofluidic chip for programmable pum**, mixing, cell focusing and trap**
Authors:
Alen Pavlic,
Cooper Lars Harshbarger,
Luca Rosenthaler,
Jess Gerrit Snedeker,
Jürg Dual
Abstract:
Precise manipulation of fluids and objects on the micro scale is seldom a simple task, but nevertheless crucial for many applications in life sciences and chemical engineering. We present a microfluidic chip fabricated in silicon-glass, featuring one or several pairs of acoustically excited sharp edges at side channels that drive a pum** flow throughout the chip and produce a strong mixing flow…
▽ More
Precise manipulation of fluids and objects on the micro scale is seldom a simple task, but nevertheless crucial for many applications in life sciences and chemical engineering. We present a microfluidic chip fabricated in silicon-glass, featuring one or several pairs of acoustically excited sharp edges at side channels that drive a pum** flow throughout the chip and produce a strong mixing flow in their vicinity. The chip is simultaneously capable of focusing cells and microparticles that are suspended in the flow. The multifunctional micropump provides a continuous flow across a wide range of excitation frequencies (80kHz-2MHz), with flow rates ranging from nL/min to $μ$L/min, depending on the excitation parameters. In the low-voltage regime, the flow rate depends quadratically on the voltage applied to the piezoelectric transducer, making the pump programmable. The behaviour in the system is elucidated with finite element method simulations, which are in good agreement with experimentally observed behaviour. The acoustic radiation force arising due to a fluidic channel resonance is responsible for the focusing of cells and microparticles, while the streaming produced by the pair of sharp edges generates the pum** and the mixing flow. If cell focusing is detrimental for a certain application, it can also be avoided by exciting the system away from the resonance frequency of the fluidic channel. The device, with its unique bundle of functionalities, displays great potential for various bio-chemical applications.
△ Less
Submitted 6 August, 2022;
originally announced August 2022.
-
Digitalization of the IOM: A comprehensive cadaveric study for obtaining three-dimensional models and morphological properties of the forearm's interosseous membrane
Authors:
Fabio Carrillo,
Simon Suter,
Fabio A. Casari,
Reto Sutter,
Ladislav Nagy,
Jess G. Snedeker,
Philipp Fürnstahl
Abstract:
State-of-the-art of preoperative planning for forearm orthopaedic surgeries is currently limited to simple bone procedures. The increasing interest of clinicians for more comprehensive analysis of complex pathologies often requires dynamic models, able to include the soft tissue influence into the preoperative process. Previous studies have shown that the interosseous membrane (IOM) influences for…
▽ More
State-of-the-art of preoperative planning for forearm orthopaedic surgeries is currently limited to simple bone procedures. The increasing interest of clinicians for more comprehensive analysis of complex pathologies often requires dynamic models, able to include the soft tissue influence into the preoperative process. Previous studies have shown that the interosseous membrane (IOM) influences forearm motion and stability, but due to the lack of morphological and biomechanical data, existing simulation models of the IOM are either too simple or clinically unreliable. This work aims to address this problematic by generating 3D morphological and tensile properties of the individual IOM structures. First, micro- and standard-CT acquisitions were performed on five fresh-frozen annotated cadaveric forearms for the generation of 3D models of the radius, ulna and each of the individual ligaments of the IOM. Afterwards, novel 3D methods were developed for the measurement of common morphological features, which were validated against established optical ex-vivo measurements. Finally, we investigated the individual tensile properties of each IOM ligament. The generated 3D morphological features can provide the basis for the future development of functional planning simulation of the forearm.
△ Less
Submitted 26 March, 2020;
originally announced March 2020.
-
An Automatic Genetic Algorithm Framework for the Optimization of Three-dimensional Surgical Plans of Forearm Corrective Osteotomies
Authors:
Fabio Carrillo,
Simon Roner,
Marco von Atzigen,
Andreas Schweizer,
Ladislav Nagy,
Lazaros Vlachopoulos,
Jess G. Snedeker,
Philipp Fürnstahl
Abstract:
3D computer-assisted corrective osteotomy has become the state-of-the-art for surgical treatment of complex bone deformities. Despite available technologies, the automatic generation of clinically acceptable, ready-to-use preoperative planning solutions is currently not possible for such pathologies. Multiple contradicting and mutually dependent objectives have to be considered, as well as clinica…
▽ More
3D computer-assisted corrective osteotomy has become the state-of-the-art for surgical treatment of complex bone deformities. Despite available technologies, the automatic generation of clinically acceptable, ready-to-use preoperative planning solutions is currently not possible for such pathologies. Multiple contradicting and mutually dependent objectives have to be considered, as well as clinical and technical constraints, generally requiring iterative manual adjustments. This leads to unnecessary efforts and unbearable clinical costs, hindering also the quality of patient treatment. In this paper, we propose an optimization framework for the generation of ready-to-use preoperative planning solutions in a fully automatic fashion. An automatic diagnostic assessment using patient-specific 3D models is performed for 3D malunion quantification and definition of the optimization parameters. Afterward, clinical objectives are translated into the optimization module, and controlled through tailored fitness functions based on a weighted and multi-staged optimization approach. The optimization is based on a genetic algorithm capable of solving multi-objective optimization problems with non-linear constraints. The framework outputs a complete preoperative planning solution including position and orientation of the osteotomy plane, transformation to achieve the bone reduction, and position and orientation of the fixation plate and screws. A qualitative validation was performed on 36 consecutive cases of radius osteotomy where solutions generated by the optimization algorithm (OA) were compared against the gold standard (GS) solutions generated by experienced surgeons. Solutions were blinded and presented to 6 readers, who voted OA solutions to be better in 55% of the time. The quantitative evaluation was based on different error measurements, showing average improvements with respect to the GS.
△ Less
Submitted 16 September, 2019;
originally announced September 2019.