-
Bright ultra-broadband fiber-based biphoton source
Authors:
Maksim A. Smirnov,
Ilya V. Fedotov,
Anastasia M. Smirnova,
Albert F. Khairullin,
Andrei B. Fedotov,
Sergey A. Moiseev
Abstract:
In this Letter, we report a first experimental realization of bright ultra-broadband (180 THz) fiber-based biphoton source with widely spectrally separated signal and idler photons. Such a two-photon source is realized due to the joint use of broadband phase-matching of interacting light waves and high optical nonlinearity of a silica-core photonic crystal fiber. The high performance of the develo…
▽ More
In this Letter, we report a first experimental realization of bright ultra-broadband (180 THz) fiber-based biphoton source with widely spectrally separated signal and idler photons. Such a two-photon source is realized due to the joint use of broadband phase-matching of interacting light waves and high optical nonlinearity of a silica-core photonic crystal fiber. The high performance of the developed fiber source identifies it as an important and useful tool for a wide range of optical quantum applications.
△ Less
Submitted 13 March, 2024;
originally announced March 2024.
-
Jupiter Science Enabled by ESA's Jupiter Icy Moons Explorer
Authors:
Leigh N. Fletcher,
Thibault Cavalié,
Davide Grassi,
Ricardo Hueso,
Luisa M. Lara,
Yohai Kaspi,
Eli Galanti,
Thomas K. Greathouse,
Philippa M. Molyneux,
Marina Galand,
Claire Vallat,
Olivier Witasse,
Rosario Lorente,
Paul Hartogh,
François Poulet,
Yves Langevin,
Pasquale Palumbo,
G. Randall Gladstone,
Kurt D. Retherford,
Michele K. Dougherty,
Jan-Erik Wahlund,
Stas Barabash,
Luciano Iess,
Lorenzo Bruzzone,
Hauke Hussmann
, et al. (25 additional authors not shown)
Abstract:
ESA's Jupiter Icy Moons Explorer (JUICE) will provide a detailed investigation of the Jovian system in the 2030s, combining a suite of state-of-the-art instruments with an orbital tour tailored to maximise observing opportunities. We review the Jupiter science enabled by the JUICE mission, building on the legacy of discoveries from the Galileo, Cassini, and Juno missions, alongside ground- and spa…
▽ More
ESA's Jupiter Icy Moons Explorer (JUICE) will provide a detailed investigation of the Jovian system in the 2030s, combining a suite of state-of-the-art instruments with an orbital tour tailored to maximise observing opportunities. We review the Jupiter science enabled by the JUICE mission, building on the legacy of discoveries from the Galileo, Cassini, and Juno missions, alongside ground- and space-based observatories. We focus on remote sensing of the climate, meteorology, and chemistry of the atmosphere and auroras from the cloud-forming weather layer, through the upper troposphere, into the stratosphere and ionosphere. The Jupiter orbital tour provides a wealth of opportunities for atmospheric and auroral science: global perspectives with its near-equatorial and inclined phases, sampling all phase angles from dayside to nightside, and investigating phenomena evolving on timescales from minutes to months. The remote sensing payload spans far-UV spectroscopy (50-210 nm), visible imaging (340-1080 nm), visible/near-infrared spectroscopy (0.49-5.56 $μ$m), and sub-millimetre sounding (near 530-625\,GHz and 1067-1275\,GHz). This is coupled to radio, stellar, and solar occultation opportunities to explore the atmosphere at high vertical resolution; and radio and plasma wave measurements of electric discharges in the Jovian atmosphere and auroras. Cross-disciplinary scientific investigations enable JUICE to explore coupling processes in giant planet atmospheres, to show how the atmosphere is connected to (i) the deep circulation and composition of the hydrogen-dominated interior; and (ii) to the currents and charged particle environments of the external magnetosphere. JUICE will provide a comprehensive characterisation of the atmosphere and auroras of this archetypal giant planet.
△ Less
Submitted 26 October, 2023; v1 submitted 20 April, 2023;
originally announced April 2023.
-
Design, Construction and Operation of a Low-Power, Autonomous Radio-Frequency Data-Acquisition Station for the TARA Experiment
Authors:
S. Kunwar,
R. Abbasi,
C. Allen,
J. Belz,
D. Besson,
M. Byrne,
B. Farhang-Boroujeny,
W. H. Gillman,
W. Hanlon,
J. Hanson,
I. Myers,
A. Novikov,
S. Prohira,
K. Ratzlaff,
A. Rezazadeh,
V. Sanivarapu,
D. Schurig,
A. Shustov,
M. Smirnova,
H. Takai,
G. B. Thomson,
R. Young
Abstract:
Employing a 40-kW radio-frequency transmitter just west of Delta, UT, and operating at 54.1 MHz, the TARA (Telescope Array RAdar) experiment seeks radar detection of extensive air showers (EAS) initiated by ultra-high energy cosmic rays (UHECR). For UHECR with energies in excess of $10^{19}$ eV, the Doppler-shifted "chirps" resulting from EAS shower core radar reflections should be observable abov…
▽ More
Employing a 40-kW radio-frequency transmitter just west of Delta, UT, and operating at 54.1 MHz, the TARA (Telescope Array RAdar) experiment seeks radar detection of extensive air showers (EAS) initiated by ultra-high energy cosmic rays (UHECR). For UHECR with energies in excess of $10^{19}$ eV, the Doppler-shifted "chirps" resulting from EAS shower core radar reflections should be observable above background (dominantly galactic) at distances of tens of km from the TARA transmitter. In order to stereoscopically reconstruct cosmic ray chirps, two remote, autonomous self-powered receiver stations have been deployed. Each remote station (RS) combines both low power consumption as well as low cost. Triggering logic, the powering and communication systems, and some specific details of hardware components are discussed.
△ Less
Submitted 29 May, 2015; v1 submitted 3 April, 2015;
originally announced April 2015.
-
Antimonotonous quadratic forms and partially ordered sets
Authors:
L. A. Nazarova,
A. V. Roiter,
M. N. Smirnova
Abstract:
Antimonotonous quadratic forms generalizing P-faithful posets defined by authors earlier are introduced. The criterion of antimonotonousness is given for posets with positive semidefinite quadratic forms. As consequence the new proofs of the criterions of finite representativity and tameness of posets are given.
Antimonotonous quadratic forms generalizing P-faithful posets defined by authors earlier are introduced. The criterion of antimonotonousness is given for posets with positive semidefinite quadratic forms. As consequence the new proofs of the criterions of finite representativity and tameness of posets are given.
△ Less
Submitted 24 January, 2005;
originally announced January 2005.
-
Position-sensitive detector for the 6-meter optical telescope
Authors:
V. Debur,
T. Arkhipova,
G. Beskin,
V. Plokhotnichenko,
M. Pakhomov,
M. Smirnova,
A. Solin
Abstract:
The Position-Sensitive Detector (PSD) for photometrical and spectral observation on the 6-meter optical telescope of the Special Astrophysical Observatory (Russia) is described. The PSD consists of a position-sensitive tube, amplifiers of output signals, analog-to-digital converters (ADC) and a digital logic plate, which produces a signal for ADC start and an external strob pulse for reading inf…
▽ More
The Position-Sensitive Detector (PSD) for photometrical and spectral observation on the 6-meter optical telescope of the Special Astrophysical Observatory (Russia) is described. The PSD consists of a position-sensitive tube, amplifiers of output signals, analog-to-digital converters (ADC) and a digital logic plate, which produces a signal for ADC start and an external strob pulse for reading information by registration system. If necessary, the thermoelectric cooler can be used. The position-sensitive tube has the following main elements: a photocathode, electrodes of inverting optics, a block of microchannel plates (MCP) and a position-sensitive collector of quadrant type. The main parameters of the PSD are the diameter of the sensitive surface is 25 mm, the spatial resolution is better than 100 (μ)m in the centre and a little worse on the periphery; the dead time is near 0.5 (μ)s; the detection quantum efficiency is defined by the photocathode and it is not less than 0.1, as a rule; dark current is about hundreds of cps, or less, when cooling. PSD spectral sensitivity depends on the type of photocathode and input window material. We use a multialkali photocathode and a fiber or UV-glass, which gives the short- wave cut of 360 nm or 250 nm, respectively.
△ Less
Submitted 15 October, 2003; v1 submitted 14 October, 2003;
originally announced October 2003.