-
Physics-informed Meta-instrument for eXperiments (PiMiX) with applications to fusion energy
Authors:
Zhehui Wang,
Shanny Lin,
Miles Teng-Levy,
**han Chu,
Bradley T. Wolfe,
Chun-Shang Wong,
Christopher S. Campbell,
Xin Yue,
Liyuan Zhang,
Derek Aberle,
Mariana Alvarado Alvarez,
David Broughton,
Ray T. Chen,
Baolian Cheng,
Feng Chu,
Eric R. Fossum,
Mark A. Foster,
Chengkun Huang,
Velat Kilic,
Karl Krushelnick,
Wenting Li,
Eric Loomis,
Thomas Schmidt Jr.,
Sky K. Sjue,
Chris Tomkins
, et al. (2 additional authors not shown)
Abstract:
Data-driven methods (DDMs), such as deep neural networks, offer a generic approach to integrated data analysis (IDA), integrated diagnostic-to-control (IDC) workflows through data fusion (DF), which includes multi-instrument data fusion (MIDF), multi-experiment data fusion (MXDF), and simulation-experiment data fusion (SXDF). These features make DDMs attractive to nuclear fusion energy and power p…
▽ More
Data-driven methods (DDMs), such as deep neural networks, offer a generic approach to integrated data analysis (IDA), integrated diagnostic-to-control (IDC) workflows through data fusion (DF), which includes multi-instrument data fusion (MIDF), multi-experiment data fusion (MXDF), and simulation-experiment data fusion (SXDF). These features make DDMs attractive to nuclear fusion energy and power plant applications, leveraging accelerated workflows through machine learning and artificial intelligence. Here we describe Physics-informed Meta-instrument for eXperiments (PiMiX) that integrates X-ray (including high-energy photons such as $γ$-rays from nuclear fusion), neutron and others (such as proton radiography) measurements for nuclear fusion. PiMiX solves multi-domain high-dimensional optimization problems and integrates multi-modal measurements with multiphysics modeling through neural networks. Super-resolution for neutron detection and energy resolved X-ray detection have been demonstrated. Multi-modal measurements through MIDF can extract more information than individual or uni-modal measurements alone. Further optimization schemes through DF are possible towards empirical fusion scaling laws discovery and new fusion reactor designs.
△ Less
Submitted 16 January, 2024;
originally announced January 2024.
-
Needs, trends, and advances in scintillators for radiographic imaging and tomography
Authors:
Zhehui Wang,
Christophe Dujardin,
Matthew S. Freeman,
Amanda E. Gehring,
James F. Hunter,
Paul Lecoq,
Wei Liu,
Charles L. Melcher,
C. L. Morris,
Martin Nikl,
Ghanshyam Pilania,
Reeju Pokharel,
Daniel G. Robertson,
Daniel J. Rutstrom,
Sky K. Sjue,
Anton S. Tremsin,
S. A. Watson,
Brenden W. Wiggins,
Nicola M. Winch,
Mariya Zhuravleva
Abstract:
Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by Röntgen, RadIT now come in many modalities such as absorption-based X-ray radiography, phase contrast X-ray imaging, coherent X-ray diffractive imaging, high-energy X- and $γ-$ray radiography at above 1 MeV, X-ra…
▽ More
Scintillators are important materials for radiographic imaging and tomography (RadIT), when ionizing radiations are used to reveal internal structures of materials. Since its invention by Röntgen, RadIT now come in many modalities such as absorption-based X-ray radiography, phase contrast X-ray imaging, coherent X-ray diffractive imaging, high-energy X- and $γ-$ray radiography at above 1 MeV, X-ray computed tomography (CT), proton imaging and tomography (IT), neutron IT, positron emission tomography (PET), high-energy electron radiography, muon tomography, etc. Spatial, temporal resolution, sensitivity, and radiation hardness, among others, are common metrics for RadIT performance, which are enabled by, in addition to scintillators, advances in high-luminosity accelerators and high-power lasers, photodetectors especially CMOS pixelated sensor arrays, and lately data science. Medical imaging, nondestructive testing, nuclear safety and safeguards are traditional RadIT applications. Examples of growing or emerging applications include space, additive manufacturing, machine vision, and virtual reality or `metaverse'. Scintillator metrics such as light yield and decay time are correlated to RadIT metrics. More than 160 kinds of scintillators and applications are presented during the SCINT22 conference. New trends include inorganic and organic scintillator heterostructures, liquid phase synthesis of perovskites and $μ$m-thick films, use of multiphysics models and data science to guide scintillator development, structural innovations such as photonic crystals, nanoscintillators enhanced by the Purcell effect, novel scintillator fibers, and multilayer configurations. Opportunities exist through optimization of RadIT with reduced radiation dose, data-driven measurements, photon/particle counting and tracking methods supplementing time-integrated measurements, and multimodal RadIT.
△ Less
Submitted 20 December, 2022;
originally announced December 2022.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
Authors:
K. Kuk,
C. Cude-Woods,
C. R. Chavez,
J. H. Choi,
J. Estrada,
M. Hoffbauer,
M. Makela,
P. Merkel,
C. L. Morris,
E. Ramberg,
Z. Wang,
T. Bailey,
M. Blatnik,
E. R. Adamek,
L. J. Broussard,
M. A. -P. Brown,
N. B. Callahan,
S. M. Clayton,
S. A. Currie,
X. Ding,
D. Dinger,
B. Filippone,
E. M. Fries,
P. Geltenbort,
E. George
, et al. (26 additional authors not shown)
Abstract:
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolutio…
▽ More
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $α$, $^7$Li and $γ$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.
△ Less
Submitted 28 February, 2019;
originally announced March 2019.
-
Using Nab to determine correlations in unpolarized neutron decay
Authors:
L. J. Broussard,
S. Baeßler,
T. L. Bailey,
N. Birge,
J. D. Bowman,
C. B. Crawford,
C. Cude-Woods,
D. E. Fellers,
N. Fomin,
E. Frlež,
M. T. W. Gericke,
L. Hayen,
A. P. Jezghani,
H. Li,
N. Macsai,
M. F. Makela,
R. R. Mammei,
D. Mathews,
P. L. McGaughey,
P. E. Mueller,
D. Počanić,
C. A. Royse,
A. Salas-Bacci,
S. K. L. Sjue,
J. C. Ramsey
, et al. (6 additional authors not shown)
Abstract:
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and…
▽ More
The Nab experiment will measure the ratio of the weak axial-vector and vector coupling constants $λ=g_A/g_V$ with precision $δλ/λ\sim3\times10^{-4}$ and search for a Fierz term $b_F$ at a level $Δb_F<10^{-3}$. The Nab detection system uses thick, large area, segmented silicon detectors to very precisely determine the decay proton's time of flight and the decay electron's energy in coincidence and reconstruct the correlation between the antineutrino and electron momenta. Excellent understanding of systematic effects affecting timing and energy reconstruction using this detection system are required. To explore these effects, a series of ex situ studies have been undertaken, including a search for a Fierz term at a less sensitive level of $Δb_F<10^{-2}$ in the beta decay of $^{45}$Ca using the UCNA spectrometer.
△ Less
Submitted 19 December, 2018;
originally announced December 2018.
-
The Nab Experiment: A Precision Measurement of Unpolarized Neutron Beta Decay
Authors:
J. Fry,
R. Alarcon,
S. Baessler,
S. Balascuta,
L. Barron-Palos,
T. Bailey,
K. Bass,
N. Birge,
A. Blose,
D. Borissenko,
J. D. Bowman,
L. J. Broussard,
A. T. Bryant,
J. Byrne,
J. R. Calarco,
J. Caylor,
K. Chang,
T. Chupp,
T. V. Cianciolo,
C. Crawford,
X. Ding,
M. Doyle,
W. Fan,
W. Farrar,
N. Fomin
, et al. (47 additional authors not shown)
Abstract:
Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $λ= g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlati…
▽ More
Neutron beta decay is one of the most fundamental processes in nuclear physics and provides sensitive means to uncover the details of the weak interaction. Neutron beta decay can evaluate the ratio of axial-vector to vector coupling constants in the standard model, $λ= g_A / g_V$, through multiple decay correlations. The Nab experiment will carry out measurements of the electron-neutrino correlation parameter $a$ with a precision of $δa / a = 10^{-3}$ and the Fierz interference term $b$ to $δb = 3\times10^{-3}$ in unpolarized free neutron beta decay. These results, along with a more precise measurement of the neutron lifetime, aim to deliver an independent determination of the ratio $λ$ with a precision of $δλ/ λ= 0.03\%$ that will allow an evaluation of $V_{ud}$ and sensitively test CKM unitarity, independent of nuclear models. Nab utilizes a novel, long asymmetric spectrometer that guides the decay electron and proton to two large area silicon detectors in order to precisely determine the electron energy and an estimation of the proton momentum from the proton time of flight. The Nab spectrometer is being commissioned at the Fundamental Neutron Physics Beamline at the Spallation Neutron Source at Oak Ridge National Lab. We present an overview of the Nab experiment and recent updates on the spectrometer, analysis, and systematic effects.
△ Less
Submitted 7 January, 2020; v1 submitted 25 November, 2018;
originally announced November 2018.
-
Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment
Authors:
Nathan Callahan,
Chen-Yu Liu,
Francisco Gonzalez,
Evan Adamek,
James David Bowman,
Leah Broussard,
S. M. Clayton,
S. Currie,
C. Cude-Woods,
E. B. Dees,
X. Ding,
E. M. Egnel,
D. Fellers,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
R. W. Pattie Jr,
J. Ramsey
, et al. (15 additional authors not shown)
Abstract:
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neut…
▽ More
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trap** in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.
△ Less
Submitted 16 October, 2018;
originally announced October 2018.
-
Precise branching ratio measurements in $^{19}$Ne beta decay and fundamental tests of the weak interaction
Authors:
B. M. Rebeiro,
S. Triambak,
P. Z. Mabika,
P. Finlay,
C. S. Sumithrarachchi,
G. Hackman,
G. C. Ball,
P. E. Garrett,
C. E. Svensson,
D. S. Cross,
R. Dunlop,
A. B. Garnsworthy,
R. Kshetri,
J. N. Orce,
M. R. Pearson,
E. R. Tardiff,
H. Al-Falou,
R. A. E. Austin,
R. Churchman,
M. K. Djongolov,
R. D'Entremont,
C. Kierans,
L. Milovanovic,
S. O'Hagan,
S. Reeve
, et al. (3 additional authors not shown)
Abstract:
We used the 8$π$ $γ$-ray spectrometer at the TRIUMF-ISAC radiocative ion beam facility to obtain high-precision branching ratios for $^{19}$Ne $β^+$ decay to excited states in $^{19}$F. Together with other previous work, our measurements determine the superallowed $1/2^+ \to 1/2^+$ beta branch to the ground state in $^{19}$F to be 99.9878(7)\%, which is three times more precise than known previous…
▽ More
We used the 8$π$ $γ$-ray spectrometer at the TRIUMF-ISAC radiocative ion beam facility to obtain high-precision branching ratios for $^{19}$Ne $β^+$ decay to excited states in $^{19}$F. Together with other previous work, our measurements determine the superallowed $1/2^+ \to 1/2^+$ beta branch to the ground state in $^{19}$F to be 99.9878(7)\%, which is three times more precise than known previously. The implications of these measurements for testing a variety of weak interaction symmetries are discussed briefly.
△ Less
Submitted 16 June, 2019; v1 submitted 4 October, 2018;
originally announced October 2018.
-
Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection
Authors:
R. W. Pattie Jr.,
N. B. Callahan,
C. Cude-Woods,
E. R. Adamek,
L. J. Broussard,
S. M. Clayton,
S. A. Currie,
E. B. Dees,
X. Ding,
E. M. Engel,
D. E. Fellers,
W. Fox,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
C. -Y. Liu,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
J. Ramsey,
D. J. Salvat,
A. Saunders,
S. J. Seestrom
, et al. (13 additional authors not shown)
Abstract:
The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay r…
▽ More
The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $τ_n$ that does not require corrections larger than the quoted uncertainties.
△ Less
Submitted 7 February, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
A new method for measuring the neutron lifetime using an in situ neutron detector
Authors:
C. L. Morris,
E. R. Adamek,
L. J. Broussard,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
X. Ding,
W. Fox,
K. P. Hickerson,
A. T. Holley,
A. Komives,
C. -Y. Liu,
M. Makela,
R. W. Pattie Jr.,
J. Ramsey,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
E. I. Sharapov,
S. K. Sjue,
Z. Tang,
J. Vanderwerp,
B. Vogelaar,
P. L. Walstrom
, et al. (6 additional authors not shown)
Abstract:
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron b…
▽ More
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.
△ Less
Submitted 14 October, 2016;
originally announced October 2016.
-
Detection System for Neutron $β$ Decay Correlations in the UCNB and Nab experiments
Authors:
L. J. Broussard,
B. A. Zeck,
E. R. Adamek,
S. Baeßler,
N. Birge,
M. Blatnik,
J. D. Bowman,
A. E. Brandt,
M. Brown,
J. Burkhart,
N. B. Callahan,
S. M. Clayton,
C. Crawford,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
N. Fomin,
E. Frlez,
J. Fry,
F. E. Gray,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
A. T. Holley
, et al. (29 additional authors not shown)
Abstract:
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise…
▽ More
We describe a detection system designed for precise measurements of angular correlations in neutron $β$ decay. The system is based on thick, large area, highly segmented silicon detectors developed in collaboration with Micron Semiconductor, Ltd. The prototype system meets specifications for $β$ electron detection with energy thresholds below 10 keV, energy resolution of $\sim$3 keV FWHM, and rise time of $\sim$50 ns with 19 of the 127 detector pixels instrumented. Using ultracold neutrons at the Los Alamos Neutron Science Center, we have demonstrated the coincident detection of $β$ particles and recoil protons from neutron $β$ decay. The fully instrumented detection system will be implemented in the UCNB and Nab experiments, to determine the neutron $β$ decay parameters $B$, $a$, and $b$.
△ Less
Submitted 7 January, 2017; v1 submitted 9 July, 2016;
originally announced July 2016.
-
Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy
Authors:
Wanchun Wei,
L. J. Broussard,
M. A. Hoffbauer,
M. Makela,
C. L. Morris,
Z. Tang,
E. R. Adamek,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
K. K. Leung,
C. -Y. Liu,
D. J. Morley,
Jose D. Ortiz,
R. W. Pattie, Jr.,
J. C. Ramsey,
A. Saunders,
S. J. Seestrom
, et al. (7 additional authors not shown)
Abstract:
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neu…
▽ More
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.
△ Less
Submitted 12 May, 2016; v1 submitted 27 April, 2016;
originally announced April 2016.
-
Radial distribution of charged particles in a magnetic field
Authors:
S. K. L. Sjue,
L. Broussard,
M. Makela,
P. L. McGaughey,
A. R. Young,
B. A. Zeck
Abstract:
The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows…
▽ More
The radial spread of charged particles emitted from a point source in a magnetic field is a potential source of systematic error for any experiment where magnetic fields guide charged particles to detectors with finite size. Assuming uniform probability as a function of the phase along the particle's helical trajectory, an analytic solution for the radial probability distribution function follows which applies to experiments in which particles are generated throughout a volume that spans a sufficient length along the axis of a homogeneous magnetic field. This approach leads to the same result as a different derivation given by Dubbers et al. But the constant phase approximation does not strictly apply to finite source volumes or fixed positions, which lead to local maxima in the radial distribution of emitted particles at the plane of the detector. A simple method is given to calculate such distributions, then the effect is demonstrated with data from a $^{207}$Bi electron-conversion source in the superconducting solenoid magnet spectrometer of the Ultracold Neutron facility at the Los Alamos Neutron Science Center. Potential future applications of this effect are discussed.
△ Less
Submitted 23 June, 2014;
originally announced June 2014.
-
Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap
Authors:
D. J. Salvat,
E. R. Adamek,
D. Barlow,
L. J. Broussard,
J. D. Bowman,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
C. -Y. Liu,
M. Makela,
J. Medina,
D. J. Morley,
C. L. Morris,
S. I. Penttila,
J. Ramsey,
A. Saunders,
S. J. Seestrom,
S. K. L. Sjue,
B. A. Slaughter
, et al. (7 additional authors not shown)
Abstract:
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN los…
▽ More
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.
△ Less
Submitted 31 October, 2013; v1 submitted 21 October, 2013;
originally announced October 2013.
-
Trapped-ion decay spectroscopy towards the determination of ground-state components of double-beta decay matrix elements
Authors:
T. Brunner,
A. Lapierre,
C. Andreoiu,
M. Brodeur,
P. Delheji,
S. Ettenauer,
D. Frekers,
A. T. Gallant,
R. Gernhäuser,
A. Grossheim,
R. Krücken,
A. Lennarz,
D. Lunney,
D. Mücher,
R. Ringle,
M. C. Simon,
V. V. Simon,
S. K. L. Sjue,
K. Zuber,
J. Dilling
Abstract:
A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and powe…
▽ More
A new technique has been developed at TRIUMF's TITAN facility to perform in-trap decay spectroscopy. The aim of this technique is to eventually measure weak electron capture branching ratios (ECBRs) and by this to consequently determine GT matrix elements of $ββ$ decaying nuclei. These branching ratios provide important input to the theoretical description of these decays. The feasibility and power of the technique is demonstrated by measuring the ECBR of $^{124}$Cs.
△ Less
Submitted 15 October, 2013;
originally announced October 2013.
-
High-Precision Measurement of the 19Ne Half-Life and Implications for Right-Handed Weak Currents
Authors:
S. Triambak,
P. Finlay,
C. S. Sumithrarachchi,
G. Hackman,
G. C. Ball,
P. E. Garrett,
C. E. Svensson,
D. S. Cross,
A. B. Garnsworthy,
R. Kshetri,
J. N. Orce,
M. R. Pearson,
E. R. Tardiff,
H. Al-Falou,
R. A. E. Austin,
R. Churchman,
M. K. Djongolov,
R. D'Entremont,
C. Kierans,
L. Milovanovic,
S. O'Hagan,
S. Reeve,
S. K. L. Sjue,
S. J. Williams
Abstract:
We report a precise determination of the 19Ne half-life to be $T_{1/2} = 17.262 \pm 0.007$ s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current Standard Model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measureme…
▽ More
We report a precise determination of the 19Ne half-life to be $T_{1/2} = 17.262 \pm 0.007$ s. This result disagrees with the most recent precision measurements and is important for placing bounds on predicted right-handed interactions that are absent in the current Standard Model. We are able to identify and disentangle two competing systematic effects that influence the accuracy of such measurements. Our findings prompt a reassessment of results from previous high-precision lifetime measurements that used similar equipment and methods.
△ Less
Submitted 26 June, 2012; v1 submitted 25 June, 2012;
originally announced June 2012.
-
Electron-capture branch of 100Tc and tests of nuclear wave functions for double-beta decays
Authors:
S. K. L. Sjue,
D. Melconian,
A. Garcia,
I. Ahmad,
A. Algora,
J. Aysto,
V. -V. Elomaa,
T. Eronen,
J. Hakala,
S. Hoedl,
A. Kankainen,
T. Kessler,
I. D. Moore,
F. Naab,
H. Penttila,
S. Rahaman,
A. Saastamoinen,
H. E. Swanson,
C. Weber,
S. Triambak,
K. Deryckx
Abstract:
We present a measurement of the electron-capture branch of $^{100}$Tc. Our value, $B(\text{EC}) = (2.6 \pm 0.4) \times 10^{-5}$, implies that the $^{100}$Mo neutrino absorption cross section to the ground state of $^{100}$Tc is roughly one third larger than previously thought. Compared to previous measurements, our value of $B(\text{EC})$ prevents a smaller disagreement with QRPA calculations re…
▽ More
We present a measurement of the electron-capture branch of $^{100}$Tc. Our value, $B(\text{EC}) = (2.6 \pm 0.4) \times 10^{-5}$, implies that the $^{100}$Mo neutrino absorption cross section to the ground state of $^{100}$Tc is roughly one third larger than previously thought. Compared to previous measurements, our value of $B(\text{EC})$ prevents a smaller disagreement with QRPA calculations relevant to double-$β$ decay matrix elements.
△ Less
Submitted 22 September, 2008;
originally announced September 2008.
-
The 3He + 4He --> 7Be Astrophysical S-factor
Authors:
T. A. D. Brown,
C. Bordeanu,
K. A. Snover,
D. W. Storm,
D. Melconian,
A. L. Sallaska,
S. K. L. Sjue,
S. Triambak
Abstract:
We present precision measurements of the 3He + 4He --> 7Be reaction in the range ECM = 0.33 to 1.23 MeV using a small gas cell and detection of both prompt gamma rays and 7Be activity. Our prompt and activity measurements are in good agreement within an experimental uncertainty of several percent. We find S(0) = 0.595 +/- 0.018 keV b from fits of the Ka**o theory to our data. We compare our res…
▽ More
We present precision measurements of the 3He + 4He --> 7Be reaction in the range ECM = 0.33 to 1.23 MeV using a small gas cell and detection of both prompt gamma rays and 7Be activity. Our prompt and activity measurements are in good agreement within an experimental uncertainty of several percent. We find S(0) = 0.595 +/- 0.018 keV b from fits of the Ka**o theory to our data. We compare our results with published measurements, and we discuss the consequences for Big Bang Nucleosynthesis and for solar neutrino flux calculations.
△ Less
Submitted 5 November, 2007; v1 submitted 5 October, 2007;
originally announced October 2007.
-
Polarized Neutron $β$-Decay: the Proton Asymmetry and Recoil-Order Currents
Authors:
S. K. L. Sjue
Abstract:
We present an analytic, recoil-order calculation of the proton asymmetry from polarized neutron $β$-decay. The differential decay rate in terms of electron energy and proton direction follows, parametrized in terms of the most general Lorentz-invariant hadron current coupled to a left-handed lepton current. Implications for experimental efforts to measure recoil-order currents are discussed.
We present an analytic, recoil-order calculation of the proton asymmetry from polarized neutron $β$-decay. The differential decay rate in terms of electron energy and proton direction follows, parametrized in terms of the most general Lorentz-invariant hadron current coupled to a left-handed lepton current. Implications for experimental efforts to measure recoil-order currents are discussed.
△ Less
Submitted 1 October, 2010; v1 submitted 15 July, 2005;
originally announced July 2005.