Characterization of a CCD array for Bragg spectroscopy
Authors:
Paul Indelicato,
Eric-Olivier Le Bigot,
Martino Trassinelli,
Detlev Gotta,
Maik Hennebach,
Nick Nelms,
Christian David,
Leopold M. Simons
Abstract:
The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $μ$rad, respectively. Such a precision satisfies the needs of modern crystal spectroscopy experiments in the field of exotic atoms and highly charged ions. Two different measurements have been performed by illuminating masks in front of the detec…
▽ More
The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $μ$rad, respectively. Such a precision satisfies the needs of modern crystal spectroscopy experiments in the field of exotic atoms and highly charged ions. Two different measurements have been performed by illuminating masks in front of the detector array by remote sources of radiation. In one case, an aluminum mask was irradiated with X-rays and in a second attempt, a nanometric quartz wafer was illuminated by a light bulb. Both methods gave consistent results with a smaller error for the optical method. In addition, the thermal expansion of the CCD detectors was characterized between -105 C and -40 C.
△ Less
Submitted 23 February, 2006;
originally announced February 2006.
-
High Resolution He-like Argon And Sulfur Spectra From The PSI ECRIT
Authors:
Martino Trassinelli,
Sandor Biri,
Stephane Boucard,
Daniel S. Covita,
Detlev Gotta,
Bruno Leoni,
Albert Hirtl,
Paul Indelicato,
Eric-Olivier Le Bigot,
Joaquim M. F. Dos Santos,
Leopold M. Simons,
Lucas Stingelin,
Joao F. C. A. Veloso,
Alfred Wasser,
Johann Zmeskal
Abstract:
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconduct…
▽ More
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconducting split coil magnet, special iron inserts which provides the mirror field, and a permanent magnetic hexapole. The high frequency was provided by a 6.4 GHz microwave emitter. We obtained high intensity X-ray spectra of multicharged F-like to He-like argon, sulfur and chlorine with one 1s hole. In particular, we observed the $1s2s^{3}S_1 \to 1s^2^{1}S_0 M1$ and $1s2p^{3}P_2 \to 1s^2^{1}S_0 M2$ transitions in He-like argon, sulfur and chlorine with unprecedented statistics and resolution. The energies of the observed lines are being determined with good accuracy using the He-like M1 line as a reference.
△ Less
Submitted 26 October, 2004;
originally announced October 2004.
-
On the characterisation of a Bragg spectrometer with X-rays from an ECR source
Authors:
D. F. Anagnostopoulos,
S. Biri,
D. Gotta,
A. Gruber,
Paul Indelicato,
B. Leoni,
H. Fuhrmann,
L. M. Simons,
L. Stingelin,
A. Wasser,
J. Zmeskal
Abstract:
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and th…
▽ More
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and the geometry of the experimental set-up.
△ Less
Submitted 23 December, 2004; v1 submitted 18 August, 2004;
originally announced August 2004.