-
Floating Potential Of Spherical Dust In Collisionless Magnetised Plasmas
Authors:
L. M. Simons,
M. Coppins
Abstract:
Determining the equilibrium charge of conducting spheres in plasmas is important for interpreting Langmuir probe measurements, plasma surface interactions and dust particle behaviour. The Monte Carlo code Dust in Magnetised Plasmas (DiMPl) has been developed for the purpose of determining the forces and charging behaviour of conducting spheroids under a variety of conditions and benchmarked agains…
▽ More
Determining the equilibrium charge of conducting spheres in plasmas is important for interpreting Langmuir probe measurements, plasma surface interactions and dust particle behaviour. The Monte Carlo code Dust in Magnetised Plasmas (DiMPl) has been developed for the purpose of determining the forces and charging behaviour of conducting spheroids under a variety of conditions and benchmarked against previous numerical results. The floating potentials of spheres in isothermal, collisionless, hydrogen plasmas as a function of magnetic field strength and size relative to Debye length are studied using DiMPl and compared with new results from the N-body tree code (pot) and recent particle in cell measurements. The results of all three simulations are similar, identifying a small range at modest ion magnetisation parameters over which the electron current is reduced relative to the ion current. The potential as a function of magnetic field strength is found to be relatively insensitive to dust size for dust smaller than the Debye length. The potential of large dust is found to depend less strongly on flow speed for modest magnetic field strengths and to decrease with increasing flow speed in the presence of strong magnetic fields for smaller dust. A semi-empirical model for the potential of small dust in a collisionless plasma as a function of magnetic field strength is developed which reproduces the expected currents and potentials in the high and low magnetic field limit.
△ Less
Submitted 31 March, 2020;
originally announced March 2020.
-
Line shape analysis of the K$β$ transition in muonic hydrogen
Authors:
D. S. Covita,
D. F. Anagnostopoulos,
H. Fuhrmann,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
T. Ishiwatari,
P. Indelicato,
T. S. Jensen,
E. -O. Le Bigot,
V. E. Markushin,
M. Nekipelov,
V. N. Pomerantsev,
V. P. Popov,
J. M. F. dos Santos,
Ph. Schmid,
L. M. Simons,
M. Theisen,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The K$β$ transition in muonic hydrogen was measured with a high-resolution crystal spectrometer. The spectrum is shown to be sensitive to the ground-state hyperfine splitting, the corresponding triplet-to-singlet ratio, and the kinetic energy distribution in the $3p$ state. The hyperfine splitting and triplet-to-singlet ratio are found to be consistent with the values expected from theoretical and…
▽ More
The K$β$ transition in muonic hydrogen was measured with a high-resolution crystal spectrometer. The spectrum is shown to be sensitive to the ground-state hyperfine splitting, the corresponding triplet-to-singlet ratio, and the kinetic energy distribution in the $3p$ state. The hyperfine splitting and triplet-to-singlet ratio are found to be consistent with the values expected from theoretical and experimental investigations and, therefore, were fixed accordingly in order to reduce the uncertainties in the further reconstruction of the kinetic energy distribution. The presence of high-energetic components was established and quantified in both a phenomenological, i.e. cascade-model-free fit, and in a direct deconvolution of the Doppler broadening based on the Bayesian approach.
△ Less
Submitted 5 April, 2018; v1 submitted 18 September, 2017;
originally announced September 2017.
-
Measurement of the charged pion mass using a low-density target of light atoms
Authors:
M Trassinelli,
D. F. Anagnostopoulos,
G Borchert,
A Dax,
J. -P Egger,
D Gotta,
M Hennebach,
P Indelicato,
Y. -W Liu,
B Manil,
N Nelms,
L. M. Simons,
A Wells
Abstract:
We present a new evaluation of the negatively charged pion mass based on the simultaneous spec-troscopy of pionic nitrogen and muonic oxygen transitions using a gaseous target composed by a N 2 /O 2 mixture at 1.4 bar. We present the experimental setup and the methods for deriving the pion mass value from the spatial separation from the 5g -- 4 f $π$N transition line and the 5g -- 4 f $μ$O transit…
▽ More
We present a new evaluation of the negatively charged pion mass based on the simultaneous spec-troscopy of pionic nitrogen and muonic oxygen transitions using a gaseous target composed by a N 2 /O 2 mixture at 1.4 bar. We present the experimental setup and the methods for deriving the pion mass value from the spatial separation from the 5g -- 4 f $π$N transition line and the 5g -- 4 f $μ$O transition line used as reference. Moreover, we discuss the importance to use dilute targets in order to minimize the influence of additional spectral lines from the presence of remaining electrons during the radiative emission. The occurrence of possible satellite lines is investigated via hypothesis testing methods using the Bayes factor.
△ Less
Submitted 30 September, 2016;
originally announced September 2016.
-
Measurement of the charged pion mass using X-ray spectroscopy of exotic atoms
Authors:
M Trassinelli,
D. F. Anagnostopoulos,
G. Borchert,
A. Dax,
J. P Egger,
D. Gotta,
M. Hennebach,
P. Indelicato,
Y. -W. Liu,
B. Manil,
N. Nelms,
L. M. Simons,
A. Wells
Abstract:
The $5g-4f$ transitions in pionic nitrogen and muonic oxygen were measured simultaneously by using a gaseous nitrogen-oxygen mixture at 1.4\,bar. Due to the precise knowledge of the muon mass the muonic line provides the energy calibration for the pionic transition. A value of (139.57077\,$\pm$\,0.00018)\,MeV/c$^{2}$ ($\pm$\,1.3ppm) is derived for the mass of the negatively charged pion, which is…
▽ More
The $5g-4f$ transitions in pionic nitrogen and muonic oxygen were measured simultaneously by using a gaseous nitrogen-oxygen mixture at 1.4\,bar. Due to the precise knowledge of the muon mass the muonic line provides the energy calibration for the pionic transition. A value of (139.57077\,$\pm$\,0.00018)\,MeV/c$^{2}$ ($\pm$\,1.3ppm) is derived for the mass of the negatively charged pion, which is 4.2ppm larger than the present world average.
△ Less
Submitted 11 May, 2016;
originally announced May 2016.
-
Hadronic shift in pionic hydrogen
Authors:
M. Hennebach,
D. F. Anagnostopoulos,
A. Dax,
H. Fuhrmann,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
Y. -W. Liu,
B. Manil,
V. E. Markushin,
A. J. Rusi el Hassani,
L. M. Simons,
M. Trassinelli,
J. Zmeskal
Abstract:
The hadronic shift in pionic hydrogen has been redetermined to be $ε_{1s}=7.086\,\pm\,0.007(stat)\,\pm\,0.006(sys)$\,eV by X-ray spectroscopy of ground state transitions applying various energy calibration schemes. The experiment was performed at the high-intensity low-energy pion beam of the Paul Scherrer Institut by using the cyclotron trap and an ultimate-resolution Bragg spectrometer with bent…
▽ More
The hadronic shift in pionic hydrogen has been redetermined to be $ε_{1s}=7.086\,\pm\,0.007(stat)\,\pm\,0.006(sys)$\,eV by X-ray spectroscopy of ground state transitions applying various energy calibration schemes. The experiment was performed at the high-intensity low-energy pion beam of the Paul Scherrer Institut by using the cyclotron trap and an ultimate-resolution Bragg spectrometer with bent crystals.
△ Less
Submitted 17 December, 2014; v1 submitted 25 June, 2014;
originally announced June 2014.
-
Pionic deuterium
Authors:
Th. Strauch,
F. D. Amaro,
D. Anagnostopoulos,
P. Bühler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. Le Bigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
S. Schlesser,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The strong interaction shift $ε$ and broadening Γ in pionic deuterium have been determined in a high statistics study of the πD(3p - 1s) X-ray transition using a high-resolution crystal spectrometer. The pionic deuterium shift will provide constraints for the pion-nucleon isospin scattering lengths extracted from measurements of shift and broadening in pionic hydrogen. The hadronic broadening is r…
▽ More
The strong interaction shift $ε$ and broadening Γ in pionic deuterium have been determined in a high statistics study of the πD(3p - 1s) X-ray transition using a high-resolution crystal spectrometer. The pionic deuterium shift will provide constraints for the pion-nucleon isospin scattering lengths extracted from measurements of shift and broadening in pionic hydrogen. The hadronic broadening is related to pion absorption and production at threshold. The results are ε= (-2356 {\pm} 31)meV (repulsive) and Γ1s = (1171+23/-49) meV yielding for the complex πD scattering length a = [-(24.99 {\pm} 0.33) + i (6.22+0.12/-0.26)]x10-3/mπ. From the imaginary part, the threshold parameter for pion production is obtained to be α = (251 +5/-11) μb. This allows, in addition, and by using results from pion absorption in 3He at threshold, the determination of the effective couplings g0 and g1 for s-wave pion absorption on isoscalar and isovector NN pairs.
△ Less
Submitted 12 July, 2011; v1 submitted 10 November, 2010;
originally announced November 2010.
-
Precision determination of the dpi -> NN transition strength at threshold
Authors:
Th. Strauch,
F. D. Amaro,
D. F. Anagnostopoulos,
P. Bühler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. LeBigot,
M. Nekipelov,
J. M. F. dos Santos,
S. Schlesser,
Ph. Schmid,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
An unusual but effective way to determine at threshold the dpi -> NN transition strength is to exploit the hadronic ground-state broadening in pionic deuterium, accessible by x-ray spectroscopy. The broadening is dominated by the true absorption channel dpi- -> nn, which is related to s-wave pion production pp -> dpi+ by charge symmetry and detailed balance. Using the exotic atom circumvents the…
▽ More
An unusual but effective way to determine at threshold the dpi -> NN transition strength is to exploit the hadronic ground-state broadening in pionic deuterium, accessible by x-ray spectroscopy. The broadening is dominated by the true absorption channel dpi- -> nn, which is related to s-wave pion production pp -> dpi+ by charge symmetry and detailed balance. Using the exotic atom circumvents the problem of Coulomb corrections to the cross section as necessary in the production experiments. Our dedicated measurement finds (1171+23/-49) meV for the broadening yielding (252+5/-11) \mub.
△ Less
Submitted 22 March, 2010;
originally announced March 2010.
-
Pionic Deuterium
Authors:
Th. Strauch,
F. D. Amaro,
D. F. Anagnostopoulos,
P. B"\uhler,
D. S. Covita,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
P. Indelicato,
E. -O. Le Bigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
S. Schlesser,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The strong interaction shift and broadening in pionic deuterium have been remeasured with high statistics by means of the (3p-1s) X-ray transition using the cyclotron trap and a high-resolution crystal spectrometer. Preliminary results are (-2325+/-31) meV (repulsive) for the shift and (1171+23/-49} meV for the width, which yields precise values for the pion-deuteron scattering length and the th…
▽ More
The strong interaction shift and broadening in pionic deuterium have been remeasured with high statistics by means of the (3p-1s) X-ray transition using the cyclotron trap and a high-resolution crystal spectrometer. Preliminary results are (-2325+/-31) meV (repulsive) for the shift and (1171+23/-49} meV for the width, which yields precise values for the pion-deuteron scattering length and the threshold parameter for pion production.
△ Less
Submitted 23 February, 2010;
originally announced February 2010.
-
Line shape of the muH(3p - 1s) hyperfine transitions
Authors:
D. S. Covita,
D. F. Anagnostopoulos,
H. Gorke,
D. Gotta,
A. Gruber,
A. Hirtl,
T. Ishiwatari,
P. Indelicato,
E. -O. LeBigot,
M. Nekipelov,
J. M. F. dos Santos,
Ph. Schmid,
L. M. Simons,
M. Trassinelli,
J. F. C. A. Veloso,
J. Zmeskal
Abstract:
The (3p - 1s) X-ray transition to the muonic hydrogen ground state was measured with a high resolution crystal spectrometer. A Doppler effect broadening of the X-ray line was established which could be attributed to different Coulomb de-excitation steps preceding the measured transition. The assumption of a statistical population of the hyperfine levels of the muonic hydrogen ground state was di…
▽ More
The (3p - 1s) X-ray transition to the muonic hydrogen ground state was measured with a high resolution crystal spectrometer. A Doppler effect broadening of the X-ray line was established which could be attributed to different Coulomb de-excitation steps preceding the measured transition. The assumption of a statistical population of the hyperfine levels of the muonic hydrogen ground state was directly confirmed by the experiment and measured values for the hyperfine splitting can be reported. The results allow a decisive test of advanced cascade model calculations and establish a method to extract fundamental strong-interaction parameters from pionic hydrogen experiments.
△ Less
Submitted 10 October, 2008; v1 submitted 9 October, 2008;
originally announced October 2008.
-
X-Ray Transitions from Antiprotonic Noble Gases
Authors:
D. Gotta,
K. Rashid,
B. Fricke,
P. Indelicato,
L. M. Simons
Abstract:
The onset of antiprotonic X-ray transitions at high principal quantum numbers and the occurence of electronic X-rays in antiprotonic argon, krypton, and xenon has been analyzed with the help of Multiconfiguration Dirac-Fock calculations. The shell-by-shell ionisation by Auger electron emission, characterised by appearance and disappearance of X-ray lines, is followed through the antiprotonic cas…
▽ More
The onset of antiprotonic X-ray transitions at high principal quantum numbers and the occurence of electronic X-rays in antiprotonic argon, krypton, and xenon has been analyzed with the help of Multiconfiguration Dirac-Fock calculations. The shell-by-shell ionisation by Auger electron emission, characterised by appearance and disappearance of X-ray lines, is followed through the antiprotonic cascade by considering transition and binding energies of both the antiproton and the remaining electrons. Electronic lines could be attributed partly to specific states of the antiprotonic atom de-excitation.
△ Less
Submitted 5 February, 2008; v1 submitted 22 January, 2008;
originally announced January 2008.
-
Highly charged ion X-rays from Electron-Cyclotron Resonance Ion Sources
Authors:
Paul Indelicato,
S. Boucard,
D. S. Covita,
D. Gotta,
A. Gruber,
A. Hirtl,
H. Fuhrmann,
E. -O. Le Bigot,
S. Schlesser,
J. M. F. Dos Santos,
L. M. Simons,
L. Stingelin,
M. Trassinelli,
J. Veloso,
A. Wasser,
J. Zmeskal
Abstract:
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show ho…
▽ More
Radiation from the highly-charged ions contained in the plasma of Electron-Cyclotron Resonance Ion Sources constitutes a very bright source of X-rays. Because the ions have a relatively low kinetic energy ($\approx 1$ eV) transitions can be very narrow, containing only small Doppler broadening. We describe preliminary accurate measurements of two and three-electron ions with Z=16--18. We show how these measurement can test sensitively many-body relativistic calculations or can be used as X-ray standards for precise measurements of X-ray transitions in exotic atoms.
△ Less
Submitted 28 October, 2006;
originally announced October 2006.
-
Characterization of a CCD array for Bragg spectroscopy
Authors:
Paul Indelicato,
Eric-Olivier Le Bigot,
Martino Trassinelli,
Detlev Gotta,
Maik Hennebach,
Nick Nelms,
Christian David,
Leopold M. Simons
Abstract:
The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $μ$rad, respectively. Such a precision satisfies the needs of modern crystal spectroscopy experiments in the field of exotic atoms and highly charged ions. Two different measurements have been performed by illuminating masks in front of the detec…
▽ More
The average pixel distance as well as the relative orientation of an array of 6 CCD detectors have been measured with accuracies of about 0.5 nm and 50 $μ$rad, respectively. Such a precision satisfies the needs of modern crystal spectroscopy experiments in the field of exotic atoms and highly charged ions. Two different measurements have been performed by illuminating masks in front of the detector array by remote sources of radiation. In one case, an aluminum mask was irradiated with X-rays and in a second attempt, a nanometric quartz wafer was illuminated by a light bulb. Both methods gave consistent results with a smaller error for the optical method. In addition, the thermal expansion of the CCD detectors was characterized between -105 C and -40 C.
△ Less
Submitted 23 February, 2006;
originally announced February 2006.
-
High Resolution He-like Argon And Sulfur Spectra From The PSI ECRIT
Authors:
Martino Trassinelli,
Sandor Biri,
Stephane Boucard,
Daniel S. Covita,
Detlev Gotta,
Bruno Leoni,
Albert Hirtl,
Paul Indelicato,
Eric-Olivier Le Bigot,
Joaquim M. F. Dos Santos,
Leopold M. Simons,
Lucas Stingelin,
Joao F. C. A. Veloso,
Alfred Wasser,
Johann Zmeskal
Abstract:
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconduct…
▽ More
We present new results on the X-ray spectroscopy of multicharged argon, sulfur and chlorine obtained with the Electron Cyclotron Resonance Ion Trap (ECRIT) in operation at the Paul Scherrer Institut (Villigen, Switzerland). We used a Johann-type Bragg spectrometer with a spherically-bent crystal, with an energy resolution of about 0.4 eV. The ECRIT itself is of a hybrid type, with a superconducting split coil magnet, special iron inserts which provides the mirror field, and a permanent magnetic hexapole. The high frequency was provided by a 6.4 GHz microwave emitter. We obtained high intensity X-ray spectra of multicharged F-like to He-like argon, sulfur and chlorine with one 1s hole. In particular, we observed the $1s2s^{3}S_1 \to 1s^2^{1}S_0 M1$ and $1s2p^{3}P_2 \to 1s^2^{1}S_0 M2$ transitions in He-like argon, sulfur and chlorine with unprecedented statistics and resolution. The energies of the observed lines are being determined with good accuracy using the He-like M1 line as a reference.
△ Less
Submitted 26 October, 2004;
originally announced October 2004.
-
On the characterisation of a Bragg spectrometer with X-rays from an ECR source
Authors:
D. F. Anagnostopoulos,
S. Biri,
D. Gotta,
A. Gruber,
Paul Indelicato,
B. Leoni,
H. Fuhrmann,
L. M. Simons,
L. Stingelin,
A. Wasser,
J. Zmeskal
Abstract:
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and th…
▽ More
Narrow X-ray lines from helium-like argon emitted from a dedicated ECR source have been used to determine the response function of a Bragg crystal spectrometer equipped with large area spherically bent silicon (111) or quartz (10$\bar{1}$) crystals. The measured spectra are compared with simulated ones created by a ray-tracing code based on the expected theoretical crystal's rocking curve and the geometry of the experimental set-up.
△ Less
Submitted 23 December, 2004; v1 submitted 18 August, 2004;
originally announced August 2004.