-
Straight versus Spongy -- Effect of Tortuosity on Polymer Imbibition into Nanoporous Matrices Assessed by Segmentation-Free Analysis of 3D Sample Reconstructions
Authors:
Fernando Vazquez Luna,
Anjani K. Maurya,
Juliana Martins de Souza e Silva,
Guido Dittrich,
Theresa Paul,
Dirk Enke,
Patrick Huber,
Ralf Wehrspohn,
Martin Steinhart
Abstract:
We comparatively analyzed imbibition of polystyrene (PS) into two complementary pore models having pore diameters of about 380 nm and hydroxyl-terminated inorganic-oxidic pore walls, controlled porous glass (CPG) and self-ordered porous alumina (AAO), by X-ray computed tomography and EDX spectroscopy. CPG contains continuous spongy-tortuous pore systems. AAO containing arrays of isolated straight…
▽ More
We comparatively analyzed imbibition of polystyrene (PS) into two complementary pore models having pore diameters of about 380 nm and hydroxyl-terminated inorganic-oxidic pore walls, controlled porous glass (CPG) and self-ordered porous alumina (AAO), by X-ray computed tomography and EDX spectroscopy. CPG contains continuous spongy-tortuous pore systems. AAO containing arrays of isolated straight cylindrical pores is a reference pore model with a tortuosity close to 1. Comparative evaluation of the spatiotemporal imbibition front evolution yields important information on the pore morphology of a probed tortuous matrix like CPG and on the imbibition mechanism. To this end, pixel brightness dispersions in tomographic 3D reconstructions and 2D EDX maps of infiltrated AAO and CPG samples were condensed into 1D brightness dispersion profiles normal to the membrane surfaces. Their statistical analysis yielded positions and widths of the imbibition fronts without segmentation or determination of pore positions. The retardation of the imbibition front movement with respect to AAO reference samples may be used as a descriptor for the tortuosity of a tested porous matrix. The velocity of the imbibition front movements in CPG equaled two-thirds of the velocity of the imbibition front movements in AAO. Moreover, the dynamics of the imbibition front broadening discloses whether porous matrices are dominated by cylindrical neck-like pore segments or by nodes. Independent single-meniscus movements in cylindrical AAO pores result in faster imbibition front broadening than in CPG, in which a morphology dominated by nodes results in slower cooperative imbibition front movements involving several menisci.
△ Less
Submitted 26 January, 2024;
originally announced January 2024.
-
Direct observation of the morphological changes in a carbon fiber composite by means of in-situ micro-CT compression experiment
Authors:
M. I. Santos,
K. Koschek,
L. Pursche,
J. M. de Souza e Silva
Abstract:
Carbon fiber reinforced polymers are widely used due to their lightweight and strong structural properties and understanding their mechanical behavior is crucial for their reliable use in structural components. In this study, we evaluated the mechanical properties of a carbon fiber reinforced composite made of a dynamic polymer based on benzoxazine and polyetheramine Jeffamine(R) ED 600. Standard…
▽ More
Carbon fiber reinforced polymers are widely used due to their lightweight and strong structural properties and understanding their mechanical behavior is crucial for their reliable use in structural components. In this study, we evaluated the mechanical properties of a carbon fiber reinforced composite made of a dynamic polymer based on benzoxazine and polyetheramine Jeffamine(R) ED 600. Standard compression tests were performed on specimens with layers oriented longitudinally or transversely to the loading direction. In-situ mechanical testing using micro-computed tomography (micro-CT) imaging was conducted to capture detailed images of the internal microstructure during deformation. Changes in porosity and pore shape were observed as the composite underwent compression. Digital Volume Correlation (DVC) analysis was applied to quantify displacements and strains within the material and enabled the visualization and quantification of strain patterns, which agree with kinking failure.
△ Less
Submitted 22 November, 2023;
originally announced November 2023.
-
Intermittent in-situ high-resolution X-ray microscopy of 400-nm porous glass under uniaxial compression: study of pore changes and crack formation
Authors:
Sebastian Schäfer,
François Willot,
Mansoureh Norouzi Rad,
Stephen T. Kelly,
Dirk Enke,
Juliana Martins de Souza e Silva
Abstract:
The properties of porous glasses and their field of application strongly depend on the characteristics of the void space. Understanding the relationship between their porous structure and failure behaviour can contribute to the development of porous glasses with long-term reliability optimized for specific applications. In the present work, we used X-ray computed tomography with nanometric resolut…
▽ More
The properties of porous glasses and their field of application strongly depend on the characteristics of the void space. Understanding the relationship between their porous structure and failure behaviour can contribute to the development of porous glasses with long-term reliability optimized for specific applications. In the present work, we used X-ray computed tomography with nanometric resolution (nano-CT) to image a controlled pore glass (CPG) with 400 nm-sized pores whilst undergoing uniaxial compression in-situ to emulate a stress process. Our results show that in-situ nano-CT provides an ideal platform for identifying the mechanisms of damage within glass with pores of 400 nm, as it allowed the tracking of the pores and struts change of shape during compression until specimen failure. We have also applied computational tools to quantify the microstructural changes within the CPG sample by map** the displacements and strain fields, and to numerically simulate the behaviour of the CPG using a Fast Fourier Transform/phase-field method. Both experimental and numerical data show local shear deformation, organized along bands, consistent with the appearance and propagation of +/- 45 degrees cracks.
△ Less
Submitted 4 July, 2023;
originally announced July 2023.
-
Statistical Analysis of Submicron X-Ray Tomography Data on Polymer Imbibition into Arrays of Cylindrical Nanopores
Authors:
Fernando Vazquez Luna,
Michael Gerstenberger,
Guido Dittrich,
Juliana Martins de Souza e Silva,
Patrick Huber,
Ralf Wehrspohn,
Martin Steinhart
Abstract:
Frozen transient imbibition states in arrays of straight cylindrical pores 400 nm in diameter were imaged by phase-contrast X-ray computed tomography with single-pore resolution. A semi-automatic algorithm yielding brightness profiles along all pores identified within the probed sample volume is described. Imbibition front positions are determined by descriptive statistics. A first approach involv…
▽ More
Frozen transient imbibition states in arrays of straight cylindrical pores 400 nm in diameter were imaged by phase-contrast X-ray computed tomography with single-pore resolution. A semi-automatic algorithm yielding brightness profiles along all pores identified within the probed sample volume is described. Imbibition front positions are determined by descriptive statistics. A first approach involves the evaluation of frequency densities of single-pore imbibition lengths, a second one the evaluation of the statistical brightness dispersion within the probed volume as a function of the distance from the pore mouths. We plotted average imbibition front positions against systematically varied powers of the imbibition time and determined the optimal exponent of the imbibition time by considering the correlation coefficients of the corresponding linear fits. Thus, slight deviations from the proportionality of the average imbibition front position to the square root of the imbibition time predicted by the Lucas-Washburn theory were found. A meaningful preexponential factor in the power law relating imbibition front position and imbibition time may only be determined after ambiguities regarding the exponent of the imbibition time are resolved. The dispersion of peaks representing the imbibition front in frequency densities of single-pore imbibition lengths and in brightness dispersion profiles plotted against the pore depth is suggested as measure of the imbibition front width. Phase-contrast X-ray computed tomography allows the evaluation of a large number of infiltrated submicron pores taking advantage of phase-contrast imaging; artifacts related to sample damage by tomography requiring physical ablation of sample material are avoided.
△ Less
Submitted 23 November, 2021;
originally announced November 2021.