-
Kaonic lead feasibility measurement at DAΦNE to solve the charged kaon mass discrepancy
Authors:
D. Bosnar,
L. Abbene,
C. Amsler,
F. Artibani,
M. Bazzi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
K. Dulski,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
M. Makek,
S. Manti,
J. Marton
, et al. (17 additional authors not shown)
Abstract:
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons im**ing on it and to form the trigger for the HPGe detector. We present…
▽ More
An HPGe detector equipped with a transistor reset preamplifier and readout with a CAEN DT5781 fast pulse digitizer was employed in the measurement of X-rays from kaonic lead at the DA$Φ$NE $e^+e^-$ collider at the Laboratori Nazionali di Frascati of INFN. A thin scintillator in front of a lead target was used to select kaons im**ing on it and to form the trigger for the HPGe detector. We present the results of the kaonic lead feasibility measurement, where we show that the resolution of the HPGe detector in regular beam conditions remains the same as that without the beam and that a satisfactory background reduction can be achieved. This measurement serves as a test bed for future dedicated kaonic X-rays measurements for the more precise determination of the charged kaon mass.
△ Less
Submitted 21 May, 2024;
originally announced May 2024.
-
Discrete symmetries tested at 10$^{-4}$ precision using linear polarization of photons from positronium annihilations
Authors:
Paweł Moskal,
Eryk Czerwiński,
Juhi Raj,
Steven D. Bass,
Ermias Y. Beyene,
Neha Chug,
Aurélien Coussat,
Catalina Curceanu,
Meysam Dadgar,
Manish Das,
Kamil Dulski,
Aleksander Gajos,
Marek Gorgol,
Beatrix C. Hiesmayr,
Bożena Jasińska,
Krzysztof Kacprzak,
Tevfik Kaplanoglu,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Simbarashe Moyo
, et al. (16 additional authors not shown)
Abstract:
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent inte…
▽ More
Discrete symmetries play an important role in particle physics with violation of CP connected to the matter-antimatter imbalance in the Universe. We report the most precise test of P, T and CP invariance in decays of ortho-positronium, performed with methodology involving polarization of photons from these decays. Positronium, the simplest bound state of an electron and positron, is of recent interest with discrepancies reported between measured hyperfine energy structure and theory at the level of $10^{-4}$ signaling a need for better understanding of the positronium system at this level. We test discrete symmetries using photon polarizations determined via Compton scattering in the dedicated J-PET tomograph on an event-by-event basis and without the need to control the spin of the positronium with an external magnetic field, in contrast to previous experiments. Our result is consistent with QED expectations at the level of 0.0007 and one standard deviation.
△ Less
Submitted 22 January, 2024;
originally announced January 2024.
-
SIDDHARTA-2 apparatus for kaonic atoms research on the DA$Φ$NE collider
Authors:
F. Sirghi,
F. Sgaramella,
L. Abbene,
C. Amsler,
M. Bazzi,
G. Borghi,
D. Bosnar,
M. Bragadireanu,
A. Buttacavoli,
M. Carminati,
M. Cargnelli,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
K. Dulski,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton
, et al. (19 additional authors not shown)
Abstract:
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA…
▽ More
SIDDHARTA-2 represents a state-of-the-art experiment designed to perform dedicated measurements of kaonic atoms, which are particular exotic atom configurations composed of a negatively charged kaon and a nucleus. Investigating these atoms provides an exceptional tool to comprehend the strong interactions in the non-perturbative regime involving strangeness. The experiment is installed at the DA$Φ$NE electron-positron collider, of the INFN National Laboratory of Frascati (INFN-LNF) in Italy, aiming to perform the first-ever measurement of the 2p$\rightarrow$1s X-ray transitions in kaonic deuterium, a crucial step towards determining the isospin-dependent antikaon-nucleon scattering lengths. Based on the experience gained with the previous SIDDHARTA experiment, which performed the most precise measurement of the kaonic hydrogen 2p$\rightarrow$1s X-ray transitions, the present apparatus has been upgraded with innovative Silicon Drift Detectors (SDDs), distributed around a cryogenic gaseous target placed in a vacuum chamber at a short distance above the interaction region of the collider. We present a comprehensive description of the SIDDHARTA-2 setup including the optimization of its various components during the commissioning phase of the collider.
△ Less
Submitted 6 November, 2023;
originally announced November 2023.
-
First measurement of kaonic helium-4 M-series transitions
Authors:
F Sgaramella,
D Sirghi,
L Abbene,
F Artibani,
M Bazzi,
D Bosnar,
M Bragadireanu,
A Buttacavoli,
M Cargnelli,
M Carminati,
A Clozza,
F Clozza,
G Deda,
R Del Grande,
L De Paolis,
K Dulski,
L Fabbietti,
C Fiorini,
I Friscic,
C Guaraldo,
M Iliescu,
M Iwasaki,
A Khreptak,
S Manti,
J Marton
, et al. (18 additional authors not shown)
Abstract:
In this paper we present the results of a new kaonic helium-4 measurement with a 1.37 g/l gaseous target by the SIDDHARTA-2 experiment at the DAΦNE collider. We measured, for the first time, the energies and yields of three transitions belonging to the Mseries. Moreover, we improved by a factor about three, the statistical precision of the 2p level energy shift and width induced by the strong inte…
▽ More
In this paper we present the results of a new kaonic helium-4 measurement with a 1.37 g/l gaseous target by the SIDDHARTA-2 experiment at the DAΦNE collider. We measured, for the first time, the energies and yields of three transitions belonging to the Mseries. Moreover, we improved by a factor about three, the statistical precision of the 2p level energy shift and width induced by the strong interaction, obtaining the most precise measurement for gaseous kaonic helium, and measured the yield of the Lα transition at the employed density, providing a new experimental input to investigate the density dependence of kaonic atoms transitions yield.
△ Less
Submitted 31 October, 2023;
originally announced October 2023.
-
CdZnTe detectors tested at the DAΦNE collider for future kaonic atoms measurements
Authors:
A. Scordo,
L. Abbene,
F. Artibani,
M. Bazzi,
M. Bettelli,
D. Bosnar,
G. Borghi,
M. Bragadireanu,
A. Buttacavoli,
M. Cargnelli,
M. Carminati,
A. Clozza,
F. Clozza,
L. De Paolis,
G. Deda,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton
, et al. (20 additional authors not shown)
Abstract:
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam deli…
▽ More
The SIDDHARTA-2 collaboration at the INFN Laboratories of Frascati (LNF) aims to perform groundbreaking measurements on kaonic atoms. In parallel and beyond the ongoing kaonic deuterium, presently running on the DA$Φ$NE collider at LNF, we plan to install additional detectors to perform further kaonic atoms' studies, taking advantage of the unique low energy and low momentum spread $K^-$ beam delivered by the at-rest decay of the $φ$ meson. CdZnTe devices are ideal for detecting transitions toward both the upper and lower levels of intermediate-mass kaonic atoms, like kaonic carbon and aluminium, which have an important impact on the strangeness sector of nuclear physics. We present the results obtained in a set of preliminary tests conducted on DA$Φ$NE, in view of measurements foreseen in 2024, with the twofold aim to tune the timing window required to reject the extremely high electromagnetic background, and to quantify the readout electronics saturation effect due to the high rate, when placed close to the Interaction Region (IR). In the first test we used commercial devices and electronics, while for the second one both were customized at the IMEM-CNR of Parma and the University of Palermo. The results confirmed the possibility of finding and matching a proper timing window where to identify the signal events and proved better performances, in terms of energy resolution, of the custom system. In both cases, strong saturation effects were confirmed, accounting for a loss of almost 90\% of the events, which will be overcome by a dedicated shielding structure foreseen for the final experimental setup.
△ Less
Submitted 23 October, 2023;
originally announced October 2023.
-
Measurements of high-n transitions in intermediate mass kaonic atoms by SIDDHARTA-2 at DA$\mathrmΦ$NE
Authors:
F. Sgaramella,
M. Tüchler,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
R. Del Grande,
L. De Paolis,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki
, et al. (16 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment installed at the DA$\mathrmΦ$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell…
▽ More
The SIDDHARTA-2 experiment installed at the DA$\mathrmΦ$NE collider of INFN-LNF performed, for the first time, measurements of high-n transitions in intermediate mass kaonic atoms during the data taking campaigns of 2021 and 2022. Kaonic carbon, oxygen, nitrogen and aluminium transitions, which occur in the setup materials, were measured by using the kaons stopped in the gaseous helium target cell with aluminium frames and Kapton walls, and are reported in this paper. These new kaonic atoms measurements add valuable input to the kaonic atoms transitions data base, which is used as a reference for theories and models of the low-energy strong interaction between antikaon and nuclei. Moreover, these results pave the way for future dedicated kaonic atoms measurements through the whole periodic table and to a new era for the antikaon-nuclei studies at low energy.
△ Less
Submitted 22 April, 2023;
originally announced April 2023.
-
Feasibility of the J-PET to monitor range of therapeutic proton beams
Authors:
Jakub Baran,
Damian Borys,
Karol Brzeziński,
Jan Gajewski,
Michał Silarski,
Neha Chug,
Aurélien Coussat,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Kavya V. Eliyan,
Aleksander Gajos Krzysztof Kacprzak,
Łukasz Kapłon,
Konrad Klimaszewski,
Paweł Konieczka,
Renata Kopeć,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Deepak Kumar,
Antony J. Lomax,
Keegan McNamara,
Szymon Niedźwiecki,
Paweł Olko,
Dominik Panek
, et al. (18 additional authors not shown)
Abstract:
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated prot…
▽ More
Objective: The aim of this work is to investigate the feasibility of the Jagiellonian Positron Emission Tomography (J-PET) scanner for intra-treatment proton beam range monitoring. Approach: The Monte Carlo simulation studies with GATE and PET image reconstruction with CASToR were performed in order to compare six J-PET scanner geometries (three dual-heads and three cylindrical). We simulated proton irradiation of a PMMA phantom with a Single Pencil Beam (SPB) and Spread-Out Bragg Peak (SOBP) of various ranges. The sensitivity and precision of each scanner were calculated, and considering the setup's cost-effectiveness, we indicated potentially optimal geometries for the J-PET scanner prototype dedicated to the proton beam range assessment. Main results: The investigations indicate that the double-layer cylindrical and triple-layer double-head configurations are the most promising for clinical application. We found that the scanner sensitivity is of the order of 10$^{-5}$ coincidences per primary proton, while the precision of the range assessment for both SPB and SOBP irradiation plans was found below 1 mm. Among the scanners with the same number of detector modules, the best results are found for the triple-layer dual-head geometry. Significance: We performed simulation studies demonstrating that the feasibility of the J-PET detector for PET-based proton beam therapy range monitoring is possible with reasonable sensitivity and precision enabling its pre-clinical tests in the clinical proton therapy environment. Considering the sensitivity, precision and cost-effectiveness, the double-layer cylindrical and triple-layer dual-head J-PET geometry configurations seem promising for the future clinical application. Experimental tests are needed to confirm these findings.
△ Less
Submitted 28 February, 2023;
originally announced February 2023.
-
TOF MLEM Adaptation for the Total-Body J-PET with a Realistic Analytical System Response Matrix
Authors:
R. Y. Shopa,
J. Baran,
K. Klimaszewski,
W. Krzemień,
L. Raczyński,
W. Wiślicki,
K. Brzeziński,
N. Chug,
A. Coussat,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
B. C. Hiesmayr,
E. Kavya Valsan,
G. Korcyl,
T. Kozik,
D. Kumar,
Ł. Kapłon,
G. Moskal,
S. Niedźwiecki,
D. Panek,
S. Parzych
, et al. (10 additional authors not shown)
Abstract:
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of…
▽ More
We report a study of the original image reconstruction algorithm based on the time-of-flight maximum likelihood expectation maximisation (TOF MLEM), developed for the total-body (TB) Jagiellonian PET (J-PET) scanners. The method is applicable to generic cylindrical or modular multi-layer layouts and is extendable to multi-photon imaging. The system response matrix (SRM) is represented as a set of analytical functions, uniquely defined for each pair of plastic scintillator strips used for the detection. A realistic resolution model (RM) in detector space is derived from fitting the Monte Carlo simulated emissions and detections of annihilation photons on oblique transverse planes. Additional kernels embedded in SRM account for TOF, parallax effect and axial smearing. The algorithm was tested on datasets, simulated in GATE for the NEMA IEC and static XCAT phantoms inside a 24-module 2-layer TB J-PET. Compared to the reference TOF MLEM with none or a shift-invariant RM, an improvement was observed, as evaluated by the analysis of image quality, difference images and ground truth metrics. We also reconstructed the data with additive contributions, pre-filtered geometrically and with non-TOF scatter correction applied. Despite some deterioration, the obtained results still capitalise on the realistic RM with better edge preservation and superior ground truth metrics. The envisioned prospects of the TOF MLEM with analytical SRM include its application in multi-photon imaging and further upgrade to account for the non-collinearity, positron range and other factors.
△ Less
Submitted 4 May, 2023; v1 submitted 6 February, 2023;
originally announced February 2023.
-
New opportunities for kaonic atoms measurements from CdZnTe detectors
Authors:
L. Abbene,
M. Bettelli,
A. Buttacavoli,
F. Principato,
A. Zappettini,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
I. Friščić,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
S. Manti,
J. Marton,
M. Miliucci
, et al. (20 additional authors not shown)
Abstract:
We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an…
▽ More
We present the tests performed by the SIDDHARTA-2 collaboration at the DAΦNE collider with a quasi-hemispherical CdZnTe detector. The very good room-temperature energy resolution and efficiency in a wide energy range show that this detector technology is ideal for studying radiative transitions in intermediate and heavy-mass kaonic atoms. The CdZnTe detector was installed for the first time in an accelerator environment to perform tests on the background rejection capabilities, which were achieved by exploiting the SIDDHARTA-2 Luminosity Monitor. A spectrum with an $^{241}Am$ source has been acquired, with beams circulating in the main rings, and peak resolutions of 6% at 60 keV and of 2.2% at 511 keV have been achieved. The background suppression factor, which turned out to be of the order of $\simeq10^{5-6}$, opens the possibility to plan for future kaonic atom measurements with CdZnTe detectors.
△ Less
Submitted 28 January, 2023;
originally announced January 2023.
-
Direct tests of T, CP, CPT symmetries in transitions of neutral K mesons with the KLOE experiment
Authors:
D. Babusci,
M. Berłowski,
C. Bloise,
F. Bossi,
P. Branchini,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
R. D'Amico,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Domenico,
E. Diociaiuti,
D. Domenici,
A. D'Uffizi,
G. Fantini,
A. Gajos,
S. Gamrat,
P. Gauzzi
, et al. (18 additional authors not shown)
Abstract:
Tests of the T, CP and CPT symmetries in the neutral kaon system are performed by the direct comparison of the probabilities of a kaon transition process to its symmetry-conjugate. The exchange of in and out states required for a genuine test involving an anti-unitary transformation implied by time-reversal is implemented exploiting the entanglement of $K^0\bar{K}{}^0$ pairs produced at a $φ$-fact…
▽ More
Tests of the T, CP and CPT symmetries in the neutral kaon system are performed by the direct comparison of the probabilities of a kaon transition process to its symmetry-conjugate. The exchange of in and out states required for a genuine test involving an anti-unitary transformation implied by time-reversal is implemented exploiting the entanglement of $K^0\bar{K}{}^0$ pairs produced at a $φ$-factory. A data sample collected by the KLOE experiment at DA$Φ$NE corresponding to an integrated luminosity of about 1.7 fb$^{-1}$ is analysed to study the $Δ$t distributions of the $φ\to K_{S}K_{L}\to π^+π^- \: π^{\pm}e^{\mp}ν$ and $φ\to K_{S}K_{L}\to π^{\pm}e^{\mp}ν\: 3π^0$ processes, with $Δ$t the difference of the kaon decay times. A comparison of the measured $Δ$t distributions in the asymptotic region $Δt \gg τ_{S}$ allows to test for the first time T and CPT symmetries in kaon transitions with a precision of few percent, and to observe CP violation with this novel method.
△ Less
Submitted 19 December, 2022; v1 submitted 22 November, 2022;
originally announced November 2022.
-
First Simultaneous K$^-$p $\rightarrow (Σ^0/Λ) \, π^0$ Cross Sections Measurements at 98 MeV/c
Authors:
Kristian Piscicchia,
Magdalena Skurzok,
Michael Cargnelli,
Raffaele Del Grande,
Laura Fabbietti,
Johann Marton,
Pawel Moskal,
Alessandro Scordo,
Àngels Ramos,
Diana Laura Sirghi,
Oton Vazquez Doce,
Johann Zmeskal,
Slawomir Wycech,
Paolo Branchini,
Filippo Ceradini,
Eryk Czerwinski,
Erika De Lucia,
Salvatore Fiore,
Andrzej Kupsc,
Giuseppe Mandaglio,
Matteo Martini,
Antonio Passeri,
Vincenzo Patera,
Elena Perez Del Rio,
Andrea Selce
, et al. (2 additional authors not shown)
Abstract:
We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements (…
▽ More
We report the first simultaneous and independent measurements of the K$^{-}$p $\rightarrow Σ^0 \, π^{0}$ and K$^{-}$p $\rightarrow Λ\, π^{0}$ cross sections around 100 MeV/c kaon momentum. The kaon beam delivered by the DA$Φ$NE collider was exploited to detect K$^-$ absorptions on Hydrogen atoms, populating the gas mixture of the KLOE drift chamber. The precision of the measurements ($σ_{K^- p \rightarrow Σ^0 π^0} = 42.8 \pm 1.5 (stat.) ^{+2.4}_{-2.0}(syst.) \ \mathrm{mb}$ and $σ_{K^- p \rightarrow Λπ^0} = 31.0 \pm 0.5 (stat.) ^{+1.2}_{-1.2}(syst.) \ \mathrm{mb}\,$) is the highest yet obtained in the low kaon momentum regime.
△ Less
Submitted 20 October, 2022; v1 submitted 19 October, 2022;
originally announced October 2022.
-
Studies of the linearity and stability of Silicon Drift Detectors for kaonic atoms X-ray spectroscopy
Authors:
A. Khreptak,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Carminati,
M. Cargnelli,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki,
H. Ohnishi,
K. Piscicchia,
Y. Sada
, et al. (14 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in…
▽ More
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform precision measurements of kaonic atoms X-ray spectroscopy for the investigation of the antikaon-nucleon strong interaction. To achieve this goal, novel large-area Silicon Drift Detectors (SDDs) have been developed. These devices have special geometry, field configuration and readout electronics that ensure excellent performance in terms of linearity and stability. The paper presents preliminary results for the linearity determination and stability monitoring of the SDDs system during the measurement of kaonic deuterium carried out in the summer of 2022.
△ Less
Submitted 31 August, 2022;
originally announced August 2022.
-
Measurement of the $K_S \to πe ν$ branching fraction with the KLOE experiment
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
R. D'Amico,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
E. Diociaiuti,
D. Domenici,
A. D'Uffizi,
G. Fantini,
A. Gajos,
S. Gamrat
, et al. (18 additional authors not shown)
Abstract:
The branching fraction for the decay $K_S \to πe ν$ has been measured with a sample of 300 million $K_S$ mesons produced in $φ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider. Signal decays are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of $K_L \to πe ν$ decays are used to evaluate sig…
▽ More
The branching fraction for the decay $K_S \to πe ν$ has been measured with a sample of 300 million $K_S$ mesons produced in $φ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider. Signal decays are selected by a boosted decision tree built with kinematic variables and time-of-flight measurements. Data control samples of $K_L \to πe ν$ decays are used to evaluate signal selection efficiencies. A fit to the reconstructed electron mass distribution finds 49647$\pm$316 signal events. Normalising to the $K_S \to π^+π^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to πe ν) = (7.211 \pm 0.046_{\rm stat} \pm 0.052_{\rm syst}) \times10^{-4}$. The combination with our previous measurement gives $\mathcal{B}(K_S \to πe ν) = (7.153 \pm 0.037_{\rm stat} \pm 0.043_{\rm syst}) \times10^{-4}$. From this value we derive $f_+(0)|V_{us}| = 0.2170 \pm 0.009$.
△ Less
Submitted 24 January, 2023; v1 submitted 9 August, 2022;
originally announced August 2022.
-
First tests of the full SIDDHARTA-2 experimental apparatus with a 4 He gaseous target
Authors:
A. Scordo,
C. Amsler,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Cargnelli,
M. Carminati,
A. Clozza,
G. Deda,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
A. Khreptak,
P. King,
P. Levi Sandri,
S. Manti,
J. Marton,
M. Miliucci,
P. Moskal,
F. Napolitano,
S. Niedźwiecki
, et al. (16 additional authors not shown)
Abstract:
In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INFN National Laboratories of Frascati. Before starting the first measurement of the kaonic deuterium 2p{\rightarrow}1s transition, accurate evaluation of the background rejection. mainly achieved with the Kaon Trigger syst…
▽ More
In this paper, we present the first tests performed after the full installation of the SIDDHARTA-2 experimental apparatus on the Interaction Region of the DAΦNE collider at the INFN National Laboratories of Frascati. Before starting the first measurement of the kaonic deuterium 2p{\rightarrow}1s transition, accurate evaluation of the background rejection. mainly achieved with the Kaon Trigger system, was required. This run, performed in the period 04-26/05/2022 with a 4 He gaseous target, confirmed the 10^5 rejection factor obtained with a reduced version of the setup and different machine conditions in 2021. This important outcome motivated the filling of the target cell with deuterium and the starting of the measurement campaign of the kaonic deuterium 2p{\rightarrow}1s transition.
△ Less
Submitted 4 August, 2022;
originally announced August 2022.
-
The SIDDHARTA-2 calibration method for high precision kaonic atoms X-ray spectroscopy measurements
Authors:
F Sgaramella,
M Miliucci,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P King,
P Levi Sandri,
J Marton,
P Moskal,
F Napolitano,
S Niedźwiecki,
K Piscicchia,
A Scordo,
H Shi,
M Silarski
, et al. (7 additional authors not shown)
Abstract:
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform the first kaonic deuterium X-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 c…
▽ More
The SIDDHARTA-2 experiment at the DA$Φ$NE collider aims to perform the first kaonic deuterium X-ray transitions to the fundamental level measurement, with a systematic error at the level of a few eV. To achieve this challenging goal the experimental apparatus is equipped with 384 Silicon Drift Detectors (SDDs) distributed around its cryogenic gaseous target. The SDDs developed by the SIDDHARTA-2 collaboration are suitable for high precision kaonic atoms spectroscopy, thanks to their high energy and time resolutions combined with their radiation hardness. The energy response of each detector must be calibrated and monitored to keep the systematic error, due to processes such as gain fluctuations, at the level of 2-3 eV. This paper presents the SIDDHARTA-2 calibration method which was optimized during the preliminary phase of the experiment in the real background conditions of the DA$Φ$NE collider, which is a fundamental tool to guarantee the high precision spectroscopic performances of the system over long periods of data taking, as that required for the kaonic deuterium measurement.
△ Less
Submitted 28 January, 2022;
originally announced January 2022.
-
Kaonic Atoms at the DA$Φ$NE Collider with the SIDDHARTA-2 Experiment
Authors:
F Napolitano,
F Sgaramella,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
L Fabbietti,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P Levi Sandri,
J Marton,
M Miliucci,
P Moskal,
S Niedźwiecki,
K Piscicchia,
A Scordo,
H Shi,
D Sirghi
, et al. (7 additional authors not shown)
Abstract:
Kaonic atoms are a unique tool to explore quantum chromodynamics in the strangeness sector at low energy, with implications reaching neutron stars and dark matter. Precision X-ray spectroscopy can fully unlock the at-threshold isospin dependent antikaon-nucleon scattering lengths, via the atomic transitions to the fundamental level. While the SIDDHARTA experiment at the INFN-LNF DA$Φ$NE collider s…
▽ More
Kaonic atoms are a unique tool to explore quantum chromodynamics in the strangeness sector at low energy, with implications reaching neutron stars and dark matter. Precision X-ray spectroscopy can fully unlock the at-threshold isospin dependent antikaon-nucleon scattering lengths, via the atomic transitions to the fundamental level. While the SIDDHARTA experiment at the INFN-LNF DA$Φ$NE collider successfully measured kaonic hydrogen, its successor SIDDHARTA-2 is starting now its data taking campaign aiming to finally fully disentangle the isoscalar and isovector scattering lengths via the measurement of kaonic deuterium. An overview of the first experimental results from a preparatory run for the SIDDAHARTA-2 experiment is presented.
△ Less
Submitted 27 January, 2022;
originally announced January 2022.
-
A new kaonic helium measurement in gas by SIDDHARTINO at the DAΦNE collider
Authors:
D Sirghi,
F Sirghi,
F Sgaramella,
M Bazzi,
D Bosnar,
M Bragadireanu,
M Carminati,
M Cargnelli,
A Clozza,
G Deda,
L De Paolis,
R Del Grande,
L Fabbietti,
C Fiorini,
C Guaraldo,
M Iliescu,
M Iwasaki,
P Levi Sandri,
J Marton,
M Miliucci,
P Moskal,
F Napolitano,
S Niedźwiecki,
K Piscicchia,
A Scordo
, et al. (8 additional authors not shown)
Abstract:
The SIDDHARTINO experiment at the DAΦNE Collider of INFN-LNF, the pilot run for the SIDDHARTA-2 experiment which aims to perform the measurement of kaonic deuterium transitions to the fundamental level, has successfully been concluded. The paper reports the main results of this run, including the optimization of various components of the apparatus, among which the degrader needed to maximize the f…
▽ More
The SIDDHARTINO experiment at the DAΦNE Collider of INFN-LNF, the pilot run for the SIDDHARTA-2 experiment which aims to perform the measurement of kaonic deuterium transitions to the fundamental level, has successfully been concluded. The paper reports the main results of this run, including the optimization of various components of the apparatus, among which the degrader needed to maximize the fraction of kaons stopped inside the target, through measurements of kaonic helium transitions to the 2p level. The obtained shift and width values are ε_2p = E_exp-E_e.m = 0.2 {\pm} 2.5(stat) {\pm} 2(syst) eV and Γ_2p = 8 {\pm} 10 eV (stat), respectively. This new measurement of the shift, in particular, represents the most precise one for a gaseous target and is expected to contribute to a better understanding of the kaon-nuclei interaction at low energy.
△ Less
Submitted 24 January, 2022;
originally announced January 2022.
-
Positronium imaging with the novel multiphoton PET scanner
Authors:
Paweł Moskal,
Kamil Dulski,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Jan Gajewski,
Aleksander Gajos,
Grzegorz Grudzień,
Beatrix C. Hiesmayr,
Krzysztof Kacprzak,
Łukasz Kapłon,
Hanieh Karimi,
Konrad Klimaszewski,
Grzegorz Korcyl,
Paweł Kowalski,
Tomasz Kozik,
Nikodem Krawczyk,
Wojciech Krzemień,
Ewelina Kubicz,
Piotr Małczak,
Szymon Niedźwiecki,
Monika Pawlik-Niedźwiecka,
Michał Pędziwiatr,
Lech Raczyński
, et al. (11 additional authors not shown)
Abstract:
In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in…
▽ More
In vivo assessment of cancer and precise location of altered tissues at initial stages of molecular disorders are important diagnostic challenges. Positronium is copiously formed in the free molecular spaces in the patient's body during positron emission tomography (PET). The positronium properties vary according to the size of inter- and intramolecular voids and the concentration of molecules in them such as, e.g., molecular oxygen, O2; therefore, positronium imaging may provide information about disease progression during the initial stages of molecular alterations. Current PET systems do not allow acquisition of positronium images. This study presents a new method that enables positronium imaging by simultaneous registration of annihilation photons and deexcitation photons from pharmaceuticals labeled with radionuclides. The first positronium imaging of a phantom built from cardiac myxoma and adipose tissue is demonstrated. It is anticipated that positronium imaging will substantially enhance the specificity of PET diagnostics.
△ Less
Submitted 16 December, 2021;
originally announced December 2021.
-
Testing CPT symmetry in ortho-positronium decays with positronium annihilation tomography
Authors:
Paweł Moskal,
Aleksander Gajos,
Muhsin Mohammed,
Jyoti Chhokar,
Neha Chug,
Catalina Curceanu,
Eryk Czerwiński,
Meysam Dadgar,
Kamil Dulski,
Marek Gorgol,
Jacek Goworek,
Beatrix Hiesmayr,
Bożena Jasińska,
Krzysztof Kacprzak,
Łukasz Kapłon,
Hanieh Karimi,
Daria Kisielewska,
Konrad Klimaszewski,
Grzegorz Korcyl,
Paweł Kowalski,
Nikodem Krawczyk,
Wojciech Krzemień,
Tomasz Kozik,
Ewelina Kubicz,
Szymon Niedźwiecki
, et al. (13 additional authors not shown)
Abstract:
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing…
▽ More
Charged lepton system symmetry under combined charge, parity, and time-reversal transformation (CPT) remains scarcely tested. Despite stringent quantum-electrodynamic limits, discrepancies in predictions for the electron-positron bound state (positronium atom) motivate further investigation, including fundamental symmetry tests. While CPT noninvariance effects could be manifested in non-vanishing angular correlations between final-state photons and spin of annihilating positronium, measurements were previously limited by knowledge of the latter. Here, we demonstrate tomographic reconstruction techniques applied to three-photon annihilations of ortho-positronium atoms to estimate their spin polarisation without magnetic field or polarised positronium source. We use a plastic-scintillator-based positron-emission-tomography scanner to record ortho-positronium (o-Ps) annihilations with single-event estimation of o-Ps spin and determine the complete spectrum of an angular correlation operator sensitive to CPT-violating effects. We find no violation at the precision level of 10^{-4}, with an over threefold improvement on the previous measurement.
△ Less
Submitted 8 December, 2021;
originally announced December 2021.
-
Precision tests of Quantum Mechanics and CPT symmetry with entangled neutral kaons at KLOE
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
R. D'Amico,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
E. Diociaiuti,
D. Domenici,
A. D'Uffizi,
A. Fantini,
G. Fantini
, et al. (33 additional authors not shown)
Abstract:
The quantum interference between the decays of entangled neutral kaons is studied in the process $φ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon…
▽ More
The quantum interference between the decays of entangled neutral kaons is studied in the process $φ\rightarrow K_S K_L \rightarrowπ^+π^-π^+π^-$, which exhibits the characteristic Einstein--Podolsky--Rosen correlations that prevent both kaons to decay into $π^+π^-$ at the same time. This constitutes a very powerful tool for testing at the utmost precision the quantum coherence of the entangled kaon pair state, and to search for tiny decoherence and CPT violation effects, which may be justified in a quantum gravity framework. The analysed data sample was collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, and corresponds to an integrated luminosity of about 1.7 fb$^{-1}$, i.e. to about $1.7 \times 10^9$ $φ\rightarrow K_S K_L$ decays produced. From the fit of the observed $Δt$ distribution, being $Δt$ the difference of the kaon decay times, the decoherence and CPT violation parameters of various phenomenological models are measured with a largely improved accuracy with respect to previous analyses. The results are consistent with no deviation from quantum mechanics and CPT symmetry, while for some parameters the precision reaches the interesting level at which -- in the most optimistic scenarios -- quantum gravity effects might show up. They provide the most stringent limits up to date on the considered models.
△ Less
Submitted 6 April, 2022; v1 submitted 8 November, 2021;
originally announced November 2021.
-
Silicon Drift Detectors spectroscopic response during the SIDDHARTA-2 Kaonic Helium run at the DAΦNE collider
Authors:
Marco Miliucci,
Massimiliano Bazzi,
Damir Bosnar,
Mario Bragadireanu,
Marco Carminati,
Michael Cargnelli,
Alberto Clozza,
Catalina Curceanu,
Griseld Deda,
Luca De Paolis,
Raffaele Del Grande,
Carlo Fiorini,
Carlo Guaraldo,
Mihail Iliescu,
Masahiko Iwasaki,
Pietro King,
Paolo Levi Sandri,
Johann Marton,
Paweł Moskal,
Fabrizio Napolitano,
Szymon Niedźwiecki,
Kristian Piscicchia,
Alessandro Scordo,
Francesco Sgaramella,
Hexi Shi
, et al. (8 additional authors not shown)
Abstract:
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high prec…
▽ More
A large-area Silicon Drift Detectors (SDDs) system has been developed by the SIDDHARTA2 collaboration for high precision light kaonic atoms X-ray spectroscopy at the DAΦNE collider of Istituto Nazionale di Fisica Nucleare - Laboratori Nazionali di Frascati. The SDDs geometry and electric field configuration, combined with their read-out electronics, make these devices suitable to perform high precision light kaonic atoms spectroscopy measurements in the high background of the DAΦNE collider. This work presents the spectroscopic response of the SDDs system during the kaonic helium first exotic atoms run of SIDDHARTA-2, preliminary to the kaonic deuterium data taking campaign
△ Less
Submitted 2 November, 2021;
originally announced November 2021.
-
Synchronisation and calibration of the 24-modules J-PET prototype with 300~mm axial field of view
Authors:
P. Moskal,
T. Bednarski,
Sz. Niedzwiecki,
M. Silarski,
E. Czerwinski,
T. Kozik,
J. Chhokar,
M. Bała,
C. Curceanu,
R. Del Grande,
M. Dadgar,
K. Dulski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk
, et al. (14 additional authors not shown)
Abstract:
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with…
▽ More
Research conducted in the framework of the J-PET project aims to develop a cost-effective total-body positron emission tomography scanner. As a first step on the way to construct a full-scale J-PET tomograph from long strips of plastic scintillators, a 24-strip prototype was built and tested. The prototype consists of detection modules arranged axially forming a cylindrical diagnostic chamber with the inner diameter of 360 mm and the axial field-of-view of 300 mm. Promising perspectives for a low-cost construction of a total-body PET scanner are opened due to an axial arrangement of strips of plastic scintillators, wchich have a small light attenuation, superior timing properties, and the possibility of cost-effective increase of the axial field-of-view. The presented prototype comprises dedicated solely digital front-end electronic circuits and a triggerless data acquisition system which required development of new calibration methods including time, thresholds and gain synchronization. The system and elaborated calibration methods including first results of the 24-module J-PET prototype are presented and discussed. The achieved coincidence resolving time equals to CRT = 490 $\pm$ 9 ps. This value can be translated to the position reconstruction accuracy $σ(Δl) =$ 18 mm which is fairly position-independent.
△ Less
Submitted 25 August, 2020;
originally announced August 2020.
-
Characterization of the SIDDHARTA-2 luminosity monitor
Authors:
M. Skurzok,
A. Scordo,
S. Niedzwiecki,
A. Baniahmad,
M. Bazzi,
D. Bosnar,
M. Bragadireanu,
M. Carminati,
M. Cargnelli,
A. Clozza,
C. Curceanu,
L. De Paolis,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
C. Guaraldo,
M. Iliescu,
M. Iwasaki,
P. Levi Sandri,
J. Marton,
M. Miliucci,
P. Moskal,
K. Piscicchia,
F. Sgaramella,
H. Shi
, et al. (7 additional authors not shown)
Abstract:
A luminosity monitor, based on plastic scintillator detectors, has been developed for the SIDDHARTA-2 experiment aiming to perform high precision measurements of kaonic atoms and was installed in 2020 on the DAFNE $e^+e^-$ collider at LNF (Laboratori Nazionali di Frascati, INFN). The main goal of this system is to provide the~instantaneous and integrated luminosity of the DAFNE facility by measuri…
▽ More
A luminosity monitor, based on plastic scintillator detectors, has been developed for the SIDDHARTA-2 experiment aiming to perform high precision measurements of kaonic atoms and was installed in 2020 on the DAFNE $e^+e^-$ collider at LNF (Laboratori Nazionali di Frascati, INFN). The main goal of this system is to provide the~instantaneous and integrated luminosity of the DAFNE facility by measuring the rate of $K^+K^-$ correlated pairs emitted by the phi meson decay. This task requires an accurate timing of the DAQ signals, as well as timing resolution below 1ns, in order to disentangle the $K^\pm$ signals from the background minimum ionizing particles (MIPs) produced during the $e^+e^-$ collisions at DAFNE. In this paper the luminosity monitor concept as well as its laboratory characterization and the first results inside DAFNE are presented.
△ Less
Submitted 15 October, 2020; v1 submitted 12 August, 2020;
originally announced August 2020.
-
Upper limit on the $η\toπ^{+}π^{-}$ branching fraction with the KLOE experiment
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini,
P. Fermani,
S. Fiore,
A. Gajos
, et al. (31 additional authors not shown)
Abstract:
Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $φ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching f…
▽ More
Based on an integrated luminosity of 1.61 fb$^{-1}$ $e^+e^-$ collision data collected with the KLOE detector at DA$Φ$NE, the Frascati $φ$-factory, a search for the $P$- and $CP$-violating decay $η\toπ^{+}π^{-}$ has been performed. Radiative $φ\toηγ$ decay is exploited to access the $η$ mesons. No signal is observed in the $π^{+}π^{-}$ invariant mass spectrum, and the upper limit on the branching fraction at 90\% confidence level is determined to be ${\mathcal B}(η\toπ^{+}π^{-})<4.9\times10^{-6}$, which is approximately three times smaller than the previous KLOE result. From the combination of these two measurements we get ${\mathcal B}(η\toπ^{+}π^{-}) < 4.4\times10^{-6}$ at 90\% confidence level.
△ Less
Submitted 28 February, 2021; v1 submitted 25 June, 2020;
originally announced June 2020.
-
The J-PET detector -- a tool for precision studies of ortho-positronium decays
Authors:
K. Dulski,
S. D. Bass,
J. Chhokar,
N. Chug,
C. Curceanu,
E. Czerwiński,
M. Dadgar,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
P. Kopka,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz
, et al. (19 additional authors not shown)
Abstract:
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events…
▽ More
The J-PET tomograph is constructed from plastic scintillator strips arranged axially in concentric cylindrical layers. It enables investigations of positronium decays by measurement of the time, position, polarization and energy deposited by photons in the scintillators, in contrast to studies conducted so far with crystal and semiconductor based detection systems where the key selection of events is based on the measurement of the photons energies. In this article we show that the J-PET tomograph system is capable of exclusive measurements of the decays of ortho-positronium atoms. We present the first positronium production results, its lifetime distribution measurements and discuss estimation of the influence of various background sources. The tomograph s performance demonstrated here makes it suitable for precision studies of positronium decays including entanglement of the final state photons, positron annihilation lifetime spectroscopy plus molecular imaging diagnostics.
△ Less
Submitted 25 May, 2021; v1 submitted 9 June, 2020;
originally announced June 2020.
-
Hit-time and hit-position reconstruction in strips of plastic scintillators using multi-threshold readouts
Authors:
N. G. Sharma,
M. Silarski,
J. Chhokar,
E. Czerwinski,
C. Curceanu,
K. Dulski,
K. Farbaniec,
A. Gajos,
R. Del Grande,
M. Gorgol,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemien,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka
, et al. (10 additional authors not shown)
Abstract:
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of th…
▽ More
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This research is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in Multi-Voltage-Technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5x9x300 mm$^3$. The obtained Time-of-Flight (TOF) and spatial resolutions amount to 325~ps (FWHM) and 25~mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using Linear Fitting method. The best TOF resolution was obtained with this method at four pre-defined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two pre-defined threshold levels. Although the algorithm of Linear Fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.
△ Less
Submitted 27 April, 2020;
originally announced April 2020.
-
Measurement of the branching fraction for the decay $K_S \to πμν$ with the KLOE detector
Authors:
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwisnski,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini,
P. Fermani,
S. Fiore,
A. Gajos
, et al. (31 additional authors not shown)
Abstract:
Based on a sample of 300 million $K_S$ mesons produced in $φ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider we have measured the branching fraction for the decay $K_S \to πμν$. The $K_S$ mesons are identified by the interaction of $K_L$ mesons in the detector. The $K_S \to πμν$ decays are selected by a boosted decision tree built with kinematic variables and by…
▽ More
Based on a sample of 300 million $K_S$ mesons produced in $φ\to K_L K_S$ decays recorded by the KLOE experiment at the DA$Φ$NE $e^+e^-$ collider we have measured the branching fraction for the decay $K_S \to πμν$. The $K_S$ mesons are identified by the interaction of $K_L$ mesons in the detector. The $K_S \to πμν$ decays are selected by a boosted decision tree built with kinematic variables and by a time-of-flight measurement. Signal efficiencies are evaluated with data control samples of $K_L \to πμν$ decays. A fit to the reconstructed muon mass distribution finds $7223 \pm 180$ signal events. Normalising to the $K_S \to π^+ π^-$ decay events the result for the branching fraction is $\mathcal{B}(K_S \to πμν) = (4.56 \pm 0.11_{\rm stat} \pm 0.17_{\rm syst})\times10^{-4}$.
△ Less
Submitted 19 March, 2020; v1 submitted 12 December, 2019;
originally announced December 2019.
-
Estimating relationship between the Time Over Threshold and energy loss by photons in plastic scintillators used in the J-PET scanner
Authors:
S. Sharma,
J. Chhokar,
C. Curceanu,
E. Czerwinski,
M. Dadgar,
K. Dulski,
J. Gajewski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
R. Del Grande,
B. C. Hiesmayr,
B. Jasinska,
K. Kacprzak,
L. Kaplon,
H. Karimi,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed
, et al. (14 additional authors not shown)
Abstract:
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in…
▽ More
Time-Over-Threshold (TOT) technique is being used widely due to its implications in develo** the multi channel readouts mainly when fast signal processing is required. Using TOT technique as a measure of energy loss instead of charge integration methods significantly reduces the signals readout cost by combining the time and energy information. Therefore, this approach can potentially be used in J-PET tomograph which is build from plastic scintillators characterized by fast light signals. The drawback in adopting this technique is lying in the non-linear correlation between input energy loss and TOT of the signal. The main motivation behind this work is to develop the relationship between TOT and energy loss and validate it with the J-PET tomograph.
The experiment was performed using the $^{22}$Na beta emitter source placed in the center of the J-PET tomograph. One can obtain primary photons of two different energies: 511 keV photon from the annihilation of positron (direct annihilation or through the formation of para-Positronim atom or pick-off process of ortho-Positronium atoms), and 1275 keV prompt photon. This allows to study the correlation between TOT values and energy loss for energy range up to 1000 keV. As the photon interacts dominantly via Compton scattering inside the plastic scintillator, there is no direct information of primary photon energy. However, using the J-PET geometry one can measure the scattering angle of the interacting photon. Since, $^{22}$Na source emits photons of two different energies, it is required to know unambiguously the energy of incident photons and its corresponding scattering angle for the estimation of energy deposition. In this work, the relationship between Time Over Threshold and energy loss by interacting photons inside the plastic scintillators used in J-PET scanner is established for a energy deposited range 100-1000 keV
△ Less
Submitted 27 November, 2019;
originally announced November 2019.
-
Performance assessment of the 2$γ$ positronium imaging with the total-body PET scanners
Authors:
P. Moskal,
D. Kisielewska,
Z. Bura,
C. Chhokar,
C. Curceanu,
E. Czerwiński,
M. Dadgar 1,
K. Dulski,
J. Gajewski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
A. Kamińska,
Ł. Kapłon,
H. Karimi,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemień,
T. Kozik,
E. Kubicz,
P. Małczak
, et al. (17 additional authors not shown)
Abstract:
In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image ba…
▽ More
In living organisms the positron-electron annihilation (occurring during the PET imaging) proceeds in about 30% via creation of a metastable ortho-positronium atom. In the tissue, due to the pick-off and conversion processes, over 98% of ortho-positronia annihilate into two 511~keV photons. In this article we assess the feasibility for reconstruction of the mean ortho-positronium lifetime image based on annihilations into two photons. The main objectives of this work include: (i) estimation of the sensitivity of the total-body PET scanners for the ortho-positronium mean lifetime imaging using $2γ$ annihilations, and (ii) estimation of the spatial and time resolution of the ortho-positronium image as a function of the coincidence resolving time (CRT) of the scanner. Simulations are conducted assuming that radiopharmaceutical is labelled with $^{44}Sc$ isotope emitting one positron and one prompt gamma. The image is reconstructed on the basis of triple coincidence events. The ortho-positronium lifetime spectrum is determined for each voxel of the image. Calculations were performed for cases of total-body detectors build of (i) LYSO scintillators as used in the EXPLORER PET, and (ii) plastic scintillators as anticipated for the cost-effective total-body J-PET scanner. To assess the spatial and time resolution the three cases were considered assuming that CRT is equal to 140ps, 50ps and 10ps. The estimated total-body PET sensitivity for the registration and selection of image forming triple coincidences is larger by a factor of 12.2 (for LYSO PET) and by factor of 4.7 (for plastic PET) with respect to the sensitivity for the standard $2γ$ imaging by LYSO PET scanners with AFOV=20cm.
△ Less
Submitted 15 November, 2019;
originally announced November 2019.
-
Monte Carlo N-Particle simulations of an underwater chemical threats detection system using neutron activation analysis
Authors:
P. Sibczyński,
M. Silarski,
O. Bezshyyko,
V. Ivanyan,
E. Kubicz,
Sz. Niedźwiecki,
P. Moskal,
J. Raj,
S. Sharma,
O. Trofimiuk
Abstract:
In this paper we present Monte Carlo N-Particle (MCNP) simulations of the system for underwater threat detection using neutron activation analysis developed in the SABAT project. The simulated system is based on a D-T neutron generator emitting 14~MeV neutrons without associated $α$ particle detection and equipped with a LaBr$_3$:Ce scintillation detector offering superior energy resolution and al…
▽ More
In this paper we present Monte Carlo N-Particle (MCNP) simulations of the system for underwater threat detection using neutron activation analysis developed in the SABAT project. The simulated system is based on a D-T neutron generator emitting 14~MeV neutrons without associated $α$ particle detection and equipped with a LaBr$_3$:Ce scintillation detector offering superior energy resolution and allowing for precise identification of activation $γ$ quanta. The performed simulations show that using the neutron activation analysis method with the designed geometry we are able to identify $γ$-rays from hydrogen, carbon, sulphur and chlorine originating from mustard gas in a sea water environment. Our results show that the most efficient way of mustard gas detection is to compare the integral peak ratio for Cl and H.
△ Less
Submitted 6 October, 2019;
originally announced October 2019.
-
Simulation studies of annihilation-photon's polarisation via Compton scattering with the J-PET tomograph
Authors:
N. Krawczyk,
B. C. Hiesmayr,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj
, et al. (10 additional authors not shown)
Abstract:
J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of…
▽ More
J-PET is the first positron-emission tomograph (PET) constructed from plastic scintillators. It was optimized for the detection of photons from electron-positron annihilation. Such photons, having an energy of 511 keV, interact with electrons in plastic scintillators predominantly via the Compton effect. Compton scattering is at most probable at an angle orthogonal to the electric field vector of the interacting photon. Thus registration of multiple photon scatterings with J-PET enables to determine the polarization of the annihilation photons. In this contribution we present estimates on the physical limitation in the accuracy of the polarization determination of $511$~keV photons with the J-PET detector.
△ Less
Submitted 18 January, 2019;
originally announced January 2019.
-
Status and Prospects of Discrete Symmetries Tests in Positronium Decays with the J-PET Detector
Authors:
M. Silarski
Abstract:
Positronium is a unique laboratory to study fundamental symmetries in the Standard Model, reflection in space ($\mathcal{P}$), reversal in time ($\mathcal{T}$), charge conjugation ($\mathcal{C}$) and their combinations. The experimental limits on the $\mathcal{C}$, $\mathcal{CP}$ and $\mathcal{CPT}$ symmetries violation in the decays of positronium are still several orders of magnitude higher than…
▽ More
Positronium is a unique laboratory to study fundamental symmetries in the Standard Model, reflection in space ($\mathcal{P}$), reversal in time ($\mathcal{T}$), charge conjugation ($\mathcal{C}$) and their combinations. The experimental limits on the $\mathcal{C}$, $\mathcal{CP}$ and $\mathcal{CPT}$ symmetries violation in the decays of positronium are still several orders of magnitude higher than the expectations. The newly constructed Jagiellonian Positron Emission Tomograph (J-PET) was optimized for the registration of photons from the electron-positron annihilations. It enables tests of discrete symmetries in decays of positronium atoms via the determination of the expectation values of the discrete-symmetries-odd operators. In this article we present the capabilities of the J-PET detector in improving the current precision of discrete symmetries tests and report on the progress of analysis data from the first data-taking runs.
△ Less
Submitted 25 November, 2018;
originally announced November 2018.
-
Feasibility studies of the polarization of photons beyond the optical wavelength regime with the J-PET detector
Authors:
P. Moskal,
N. Krawczyk,
B. C. Hiesmayr,
M. Bała,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
R. Del Grande,
B. Jasińska,
K. Kacprzak,
L. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
J. Raj,
Z. Rudy
, et al. (9 additional authors not shown)
Abstract:
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on…
▽ More
J-PET is a detector optimized for registration of photons from the electron-positron annihilation via plastic scintillators where photons interact predominantly via Compton scattering. Registration of both primary and scattered photons enables to determinate the linear polarization of the primary photon on the event by event basis with a certain probability. Here we present quantitative results on the feasibility of such polarization measurements of photons from the decay of positronium with the J-PET and explore the physical limitations for the resolution of the polarization determination of 511 keV photons via Compton scattering. For scattering angles of about 82 deg (where the best contrast for polarization measurement is theoretically predicted) we find that the single event resolution for the determination of the polarization is about 40 deg (predominantly due to properties of the Compton effect). However, for samples larger than ten thousand events the J-PET is capable of determining relative average polarization of these photons with the precision of about few degrees. The obtained results open new perspectives for studies of various physics phenomena such as quantum entanglement and tests of discrete symmetries in decays of positronium and extend the energy range of polarization measurements by five orders of magnitude beyond the optical wavelength regime.
△ Less
Submitted 27 September, 2018;
originally announced September 2018.
-
K$^-$ multi-nucleon absorption cross sections and branching ratios in $Λ$p and $Σ^0$p final states
Authors:
R. Del Grande,
K. Piscicchia,
O. Vazquez Doce,
M. Cargnelli,
C. Curceanu,
L. Fabbietti,
J. Marton,
P. Moskal,
A. Ramos,
A. Scordo,
D. Sirghi,
M. Skurzok,
S. Wycech,
J. Zmeskal,
E. Czerwinski,
V. De Leo,
P. Fermani,
G. Mandaglio,
M. Martini,
N. Raha,
A. Selce,
M. Silarski
Abstract:
The determination of low-energy cross sections and branching ratios of the K$^-$ multi-nucleon absorption processes in $Λ$p and $Σ^0$p final states performed by the AMADEUS collaboration is presented. Low momentum K$^-$ ($p_\mathrm{K} \simeq$ 127 MeV/c) produced at the DA$Φ$NE collider are im**ed on a Carbon target within the KLOE detector and the two and three nucleon absorption processes are d…
▽ More
The determination of low-energy cross sections and branching ratios of the K$^-$ multi-nucleon absorption processes in $Λ$p and $Σ^0$p final states performed by the AMADEUS collaboration is presented. Low momentum K$^-$ ($p_\mathrm{K} \simeq$ 127 MeV/c) produced at the DA$Φ$NE collider are im**ed on a Carbon target within the KLOE detector and the two and three nucleon absorption processes are disentangled by comparing the experimental data to phenomenological calculations. The $Λ$p spectra are interpreted in terms of K$^-$ multi-nucleon absorption processes; the possible contribution of a K$^-$pp bound state is demonstrated to overlap with the two nucleon capture process, its absolute yield thus resulting indistinguishable.
△ Less
Submitted 12 March, 2019; v1 submitted 19 September, 2018;
originally announced September 2018.
-
Commissioning of the J-PET detector in view of the positron annihilation lifetime spectroscopy
Authors:
K. Dulski,
C. Curceanu,
E. Czerwiński,
A. Gajos,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak Ł. Kapłon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
N. Krawczyk,
W. Krzemień,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
K. Rakoczy,
Z. Rudy
, et al. (8 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of ana…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is the first PET device built from plastic scintillators. It is a multi-purpose detector designed for medical imaging and for studies of properties of positronium atoms in porous matter and in living organisms. In this article we report on the commissioning of the J-PET detector in view of studies of positronium decays. We present results of analysis of the positron lifetime measured in the porous polymer. The obtained results prove that J-PET is capable of performing simultaneous imaging of the density distribution of annihilation points as well as positron annihilation lifetime spectroscopy.
△ Less
Submitted 12 September, 2018;
originally announced September 2018.
-
Near threshold kaon-kaon interaction in the reactions e+ e- --> K+ K- gamma and e+ e- --> K0 K0bar gamma
Authors:
L. Lesniak,
F. Sobczuk,
M. Silarski,
F. Morawski
Abstract:
Strong interactions between pairs of the K+ K- and K0 K0bar mesons can be studied in radiative decays of phi(1020) mesons. We present a theoretical model of the reactions e+ e- --> phi --> K+ K- gamma and e+ e- --> phi --> K0 K0bar gamma. The K+ K- and K0 K0bar effective mass dependence of the differential cross sections is derived. The total cross sections and the branching fractions for the two…
▽ More
Strong interactions between pairs of the K+ K- and K0 K0bar mesons can be studied in radiative decays of phi(1020) mesons. We present a theoretical model of the reactions e+ e- --> phi --> K+ K- gamma and e+ e- --> phi --> K0 K0bar gamma. The K+ K- and K0 K0bar effective mass dependence of the differential cross sections is derived. The total cross sections and the branching fractions for the two radiative phi decays are calculated.
△ Less
Submitted 10 September, 2018;
originally announced September 2018.
-
A feasibility study of the time reversal violation test based on polarization of annihilation photons from the decay of ortho-Positronium with the J-PET detector
Authors:
J. Raj,
A. Gajos,
C. Curceanu,
E. Czerwinski,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
L. Kaplon,
D. Kisielewska,
K. Klimaszewski,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemien,
E. Kubicz,
M. Mohammed,
Sz. Niedzwiecki,
M. Palka,
M. Pawlik-Niedzwiecka,
L. Raczynski,
K. Rakoczy
, et al. (9 additional authors not shown)
Abstract:
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET…
▽ More
The Jagiellonian Positron Emission Tomograph (J-PET) is a novel de- vice being developed at Jagiellonian University in Krakow, Poland based on or- ganic scintillators. J-PET is an axially symmetric and high acceptance scanner that can be used as a multi-purpose detector system. It is well suited to pur- sue tests of discrete symmetries in decays of positronium in addition to medical imaging. J-PET enables the measurement of both momenta and the polarization vectors of annihilation photons. The latter is a unique feature of the J-PET detector which allows the study of time reversal symmetry violation operator which can be constructed solely from the annihilation photons momenta before and after the scattering in the detector.
△ Less
Submitted 4 September, 2018;
originally announced September 2018.
-
Strong interaction between kaons in the reactions e+ e- --> K+ K- gamma and e+ e- --> K0 K0bar gamma
Authors:
L. Lesniak,
F. Sobczuk,
M. Silarski,
F. Morawski
Abstract:
A theoretical model of the reactions e+ e- --> K+ K- gamma and e+ e- --> K0 K0bar gamma has been derived. The strong interaction between kaons is taken into account using a general form of the K Kbar scattering amplitude. It is shown that some models formulated in the past are particular cases of the present approach. The formulae for the K Kbar effective mass dependence of the differential cross…
▽ More
A theoretical model of the reactions e+ e- --> K+ K- gamma and e+ e- --> K0 K0bar gamma has been derived. The strong interaction between kaons is taken into account using a general form of the K Kbar scattering amplitude. It is shown that some models formulated in the past are particular cases of the present approach. The formulae for the K Kbar effective mass dependence of the differential cross section as well as for the angular kaon and photon distributions and for the branching fractions of the phi(1020)--> K+ K- gamma and phi(1020)--> K0 K0bar gamma decays have been obtained. We present numerical results for the functions entering into transition amplitudes, K Kbar effective mass distributions, total cross sections, and branching fractions. Finally, the model is generalized to treat other reactions with two pseudoscalar mesons accompanying a photon in the final state.
△ Less
Submitted 3 September, 2018;
originally announced September 2018.
-
Estimating the NEMA characteristics of the J-PET tomograph using the GATE package
Authors:
Paweł Kowalski,
Wojciech Wiślicki,
Roman Shopa,
Lech Raczyński,
Konrad Klimaszewski,
Catalina Curceanu,
Eryk Czerwiński,
Kamil Dulski,
Aleksander Gajos,
Marek Gorgol,
Neha Gupta-Sharma,
Beatrix Hiesmayr,
Bożena Jasińska,
Łukasz Kapłon,
Daria Kamińska,
Grzegorz Korcyl,
Tomasz Kozik,
Wojciech Krzemień,
Ewelina Kubicz,
Muhsin Mohammed,
Szymon Niedzwiecki,
Marek Pałka,
Monika Pawlik-Niedźwiecka,
Juhi Raj,
Kamil Rakoczy
, et al. (8 additional authors not shown)
Abstract:
The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were…
▽ More
The novel whole-body PET system based on plastic scintillators is developed by the {J-PET} Collaboration. It consists of plastic scintillator strips arranged axially in the form of a cylinder, allowing the cost-effective construction of the total-body PET. In order to determine properties of the scanner prototype and optimize its geometry, advanced computer simulations using the GATE software were performed.
The spatial resolution, the sensitivity, the scatter fraction and the noise equivalent count rate were estimated according to the NEMA norm as a function of the length of the tomograph, number of the detection layers, diameter of the tomographic chamber and for various types of the applied readout. For the single-layer geometry with the diameter of 85 cm, strip length of 100 cm, cross-section of 4 mm x 20 mm and silicon photomultipliers with the additional layer of wavelength shifter as the readout, the spatial resolution (FWHM) in the centre of the scanner is equal to 3 mm (radial, tangential) and 6 mm (axial). For the analogous double-layer geometry with the same readout, diameter and scintillator length, with the strip cross-section of 7 mm x 20 mm, the NECR peak of 300 kcps was reached at 40 kBq/cc activity concentration, the scatter fraction is estimated to about 35% and the sensitivity at the centre amounts to 14.9 cps/kBq. Sensitivity profiles were also determined.
△ Less
Submitted 1 August, 2018;
originally announced August 2018.
-
Evaluation of Single-Chip, Real-Time Tomographic Data Processing on FPGA - SoC Devices
Authors:
G. Korcyl,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
B. Flak,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
M. Kajetanowicz,
D. Kisielewska,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pawlik-Niedźwiecka,
M. Pałka,
L. Raczyński,
P. Rajda
, et al. (14 additional authors not shown)
Abstract:
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data…
▽ More
A novel approach to tomographic data processing has been developed and evaluated using the Jagiellonian PET (J-PET) scanner as an example. We propose a system in which there is no need for powerful, local to the scanner processing facility, capable to reconstruct images on the fly. Instead we introduce a Field Programmable Gate Array (FPGA) System-on-Chip (SoC) platform connected directly to data streams coming from the scanner, which can perform event building, filtering, coincidence search and Region-Of-Response (ROR) reconstruction by the programmable logic and visualization by the integrated processors. The platform significantly reduces data volume converting raw data to a list-mode representation, while generating visualization on the fly.
△ Less
Submitted 26 July, 2018;
originally announced July 2018.
-
Combined limit on the production of a light gauge boson decaying into $μ^+μ^-$ and $π^+π^-$
Authors:
KLOE-2 Collaboration,
:,
A. Anastasi,
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostinio,
E. Dané,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini
, et al. (35 additional authors not shown)
Abstract:
We searched for the $μ^+μ^-$ decay of a light vector gauge boson, also known as dark photon, in the $e^+ e^- \to μ^+ μ^- γ_{\rm ISR}$ process by means of the Initial State Radiation (ISR) method. We used 1.93~fb$^{-1}$ of data collected by the KLOE experiment at the DA$Φ$NE $φ$-factory. No structures have been observed over the irreducible $μ^+ μ^-$ background. A 90\% CL limit on the ratio…
▽ More
We searched for the $μ^+μ^-$ decay of a light vector gauge boson, also known as dark photon, in the $e^+ e^- \to μ^+ μ^- γ_{\rm ISR}$ process by means of the Initial State Radiation (ISR) method. We used 1.93~fb$^{-1}$ of data collected by the KLOE experiment at the DA$Φ$NE $φ$-factory. No structures have been observed over the irreducible $μ^+ μ^-$ background. A 90\% CL limit on the ratio $\varepsilon^2=α^{\prime}/α$ between the dark coupling constant and the fine structure constant of $ 3\times 10^{-6}-2\times 10^{-7}$ has been set in the dark photon mass region between 519 MeV and 973 MeV. This new limit has been combined with the published result obtained investigating the hypothesis of the dark photon decaying into hadrons in $e^+ e^- \to π^+ π^- γ_{\rm ISR}$ events. The combined 90\% CL limit increases the sensitivity especially in the $ρ-ω$ interference region and excludes $\varepsilon^2$ greater than $(13-2)\times 10^{-7}$. For dark photon masses greater than 600 MeV the combined limit is lower than 8~$\times\, 10^{-7}$ resulting more stringent than present constraints from other experiments.
△ Less
Submitted 9 August, 2018; v1 submitted 7 July, 2018;
originally announced July 2018.
-
Measurement of the charge asymmetry for the $K_S \rightarrow πe ν$ decay and test of CPT symmetry with the KLOE detector
Authors:
A. Anastasi,
D. Babusci,
M. Berłowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
B. Cao,
G. Capon,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi,
A. Fantini,
G. Fantini
, et al. (35 additional authors not shown)
Abstract:
Using 1.63 fb$^{-1}$ of integrated luminosity collected by the KLOE experiment about $7\times 10^4$ $K_S \rightarrow π^{\pm}e^{\mp}ν$ decays have been reconstructed. The measured value of the charge asymmetry for this decay is $A_S = (-4.9 \pm 5.7_{stat} \pm 2.6_{syst}) \times 10^{-3}$, which is almost twice more precise than the previous KLOE result. The combination of these two measurements give…
▽ More
Using 1.63 fb$^{-1}$ of integrated luminosity collected by the KLOE experiment about $7\times 10^4$ $K_S \rightarrow π^{\pm}e^{\mp}ν$ decays have been reconstructed. The measured value of the charge asymmetry for this decay is $A_S = (-4.9 \pm 5.7_{stat} \pm 2.6_{syst}) \times 10^{-3}$, which is almost twice more precise than the previous KLOE result. The combination of these two measurements gives $A_S = (-3.8 \pm 5.0_{stat} \pm 2.6_{syst}) \times 10^{-3}$ and, together with the asymmetry of the $K_L$ semileptonic decay, provides significant tests of the CPT symmetry. The obtained results are in agreement with CPT invariance.
△ Less
Submitted 11 August, 2018; v1 submitted 22 June, 2018;
originally announced June 2018.
-
Feasibility study of the positronium imaging with the J-PET tomograph
Authors:
P. Moskal,
D. Kisielewska,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
G. Korcyl,
P. Kowalski,
W. Krzemień,
T. Kozik,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
S. Sharma,
Shivani,
R. Y. Shopa
, et al. (5 additional authors not shown)
Abstract:
A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibili…
▽ More
A detection system of the conventional PET tomograph is set-up to record data from e+ e- annihilation into two photons with energy of 511 keV, and it gives information on the density distribution of a radiopharmaceutical in the body of the object. In this paper we explore the possibility of performing the three gamma photons imaging based on ortho-positronium annihilation, as well as the possibility of positronium mean lifetime imaging with the J-PET tomograph constructed from plastic scintillators. For this purposes simulations of the ortho-positronium formation and its annihilation into three photons were performed taking into account distributions of photons' momenta as predicted by the theory of quantum electrodynamics and the response of the J-PET tomograph. In order to test the proposed ortho-positronium lifetime image reconstruction method, we concentrate on the decay of the ortho-positronium into three photons and applications of radiopharmaceuticals labeled with isotopes emitting a prompt gamma quantum. The proposed method of imaging is based on the determination of hit-times and hit-positions of registered photons which enables the reconstruction of the time and position of the annihilation point as well as the lifetime of the ortho-positronium on an event-by-event basis. We have simulated the production of the positronium in a cylindrical phantom composed of a set of different materials in which the ortho-positronium lifetime varied from 2.0 ns to 3.0 ns, as expected for ortho-positronium created in the human body. The presented reconstruction method for total-body J-PET like detector allows to achieve a mean lifetime resolution of about 40 ps. Recent Positron Annihilation Lifetime Spectroscopy measurements of cancerous and healthy uterine tissues show that this sensitivity may allow to study the morphological changes in cell structures.
△ Less
Submitted 15 January, 2019; v1 submitted 29 May, 2018;
originally announced May 2018.
-
Feasibility study of the time reversal symmetry tests in decays of metastable positronium atoms with the J-PET detector
Authors:
A. Gajos,
C. Curceanu,
E. Czerwiński,
K. Dulski,
M. Gorgol,
N. Gupta-Sharma,
B. C. Hiesmayr,
B. Jasińska,
K. Kacprzak,
Ł. Kapłon,
D. Kisielewska,
G. Korcyl,
P. Kowalski,
T. Kozik,
W. Krzemień,
E. Kubicz,
M. Mohammed,
Sz. Niedźwiecki,
M. Pałka,
M. Pawlik-Niedźwiecka,
L. Raczyński,
J. Raj,
Z. Rudy,
S. Sharma,
Shivani
, et al. (7 additional authors not shown)
Abstract:
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correl…
▽ More
This article reports on the feasibility of testing of the symmetry under reversal in time in a purely leptonic system constituted by positronium atoms using the J-PET detector. The present state of T symmetry tests is discussed with an emphasis on the scarcely explored sector of leptonic systems. Two possible strategies of searching for manifestations of T violation in non-vanishing angular correlations of final state observables in the decays of metastable triplet states of positronium available with J-PET are proposed and discussed. Results of a pilot measurement with J-PET and assessment of its performance in reconstruction of three-photon decays are shown along with an analysis of its impact on the sensitivity of the detector for the determination of T -violation sensitive observables.
△ Less
Submitted 19 April, 2018;
originally announced April 2018.
-
The kaonic atoms research program at DAΦNE: from SIDDHARTA to SIDDHARTA-2
Authors:
A. Scordo,
A. Amirkhani,
M. Bazzi,
G. Bellotti,
C. Berucci,
D. Bosnar,
A. M. Bragadireanu,
M. Cargnelli,
C. Curceanu,
A. Dawood Butt,
R. Del Grande,
L. Fabbietti,
C. Fiorini,
F. Ghio,
C. Guaraldo,
R. S. Hayano,
M. Iliescu,
M. Iwasaki,
P. Levi Sandri,
J. Marton,
M. Miliucci,
P. Moskal,
D. Pietreanu,
K. Piscicchia,
H. Shi
, et al. (9 additional authors not shown)
Abstract:
The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms, in which one electron is replaced by a negatively charged kaon, is a unique tool to provide precise information on this interaction; the energy shift and the broadening of the low-lyin…
▽ More
The interaction of antikaons with nucleons and nuclei in the low-energy regime represents an active research field in hadron physics with still many important open questions. The investigation of light kaonic atoms, in which one electron is replaced by a negatively charged kaon, is a unique tool to provide precise information on this interaction; the energy shift and the broadening of the low-lying states of such atoms, induced by the kaon-nucleus hadronic interaction, can be determined with high precision from the atomic X-ray spectroscopy, and this experimental method provides unique information to understand the low energy kaon-nucleus interaction at the production threshold. The lightest atomic systems, like the kaonic hydrogen and the kaonic deuterium deliver, in a model-independent way, the isospin-dependent kaon-nucleon scattering lengths. The most precise kaonic hydrogen measurement to-date, together with an exploratory measurement of kaonic deuterium, were carried out in 2009 by the SIDDHARTA collaboration at the DAΦNE electron-positron collider of LNF-INFN, combining the excellent quality kaon beam delivered by the collider with new experimental techniques, as fast and very precise X-ray detectors, like the Silicon Drift Detectors. The SIDDHARTA results triggered new theoretical work, which achieved major progress in the understanding of the low-energy strong interaction with strangeness reflected by the antikaon-nucleon scattering lengths calculated with the antikaon-proton amplitudes constrained by the SIDDHARTA data. The most important open question is the experimental determination of the hadronic energy shift and width of kaonic deuterium; presently, a major upgrade of the setup, SIDDHARTA-2, is being realized to reach this goal. In this paper, the results obtained in 2009 and the proposed SIDDHARTA-2 upgrades are presented.
△ Less
Submitted 21 March, 2018; v1 submitted 7 March, 2018;
originally announced March 2018.
-
Towards 2+1 photon tomography: Energy-based selection of two 511 keV photons and a prompt photon with the J-PET scanner
Authors:
R. Masełek,
W. Krzemien,
K. Klimaszewski,
L. Raczyński,
P. Kowalski,
R. Shopa,
W. Wiślicki,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
M. Gorgol,
B. Hiesmayr,
B. Jasińska,
D. Kisielewska,
G. Korcyl,
T. Kozik,
N. Krawczyk,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka
, et al. (9 additional authors not shown)
Abstract:
The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ deca…
▽ More
The possibility to separate signals caused by 511 keV photons created in annihilation of electron-positron pairs and the so-called prompt photons from nuclei de- excitation is investigated. It could potentially be used to improve the quality of reconstructed images in the J-PET scanner in 2+1 photon tomography. Firstly, a research is conducted for several radioisotopes that decay via \b{eta}+ decay followed by de-excitation of an excited nucleus. Efficiency, purity and false positive rate are calculated for each isotope as a function of energy deposited threshold, with a hypothesis that signals caused by 511 keV photons deposit smaller values of energy than 1 z 13the selected threshold, while prompt photons deposit larger energy than the threshold. Analysis of the results accompanied with physical properties of radioisotopes suggests using 44 Sc, which is the most promising candidate for medical applications. With the use of GATE and J-POS simulation software, in-phantom scattering was introduced and the best energy deposited threshold value was estimated to be approximately 375 keV. It corresponds to almost 100% efficiency for 511 keV signals, 75% purity for 511 keV photons, and approximately 70% efficiency and purity for prompt photons.
△ Less
Submitted 2 March, 2018;
originally announced March 2018.
-
Search for Deeply Bound Kaonic Nuclear States with AMADEUS
Authors:
M. Skurzok,
M. Cargnelli,
C. Curceanu,
R. Del Grande,
L. Fabbietti,
C. Guaraldo,
J. Marton,
P. Moskal,
K. Piscicchia,
A. Scordo,
M. Silarski,
D. L. Sirghi,
I. Tucakovic,
O. Vazquez Doce,
S. Wycech,
E. Widmann,
J. Zmeskal
Abstract:
We briefly report on the search for Deeply Bound Kaonic Nuclear States with AMADEUS in the Sigma0 p channel following K- absorption on 12C and outline future perspectives for this work.
We briefly report on the search for Deeply Bound Kaonic Nuclear States with AMADEUS in the Sigma0 p channel following K- absorption on 12C and outline future perspectives for this work.
△ Less
Submitted 28 December, 2017;
originally announced December 2017.
-
Underwater detection of dangerous substances: status the SABAT project
Authors:
M. Silarski,
P. Sibczyński,
Sz. Niedźwiecki,
S. Sharma,
J. Raj,
P. Moskal
Abstract:
The Neutron Activation Analysis (NAA) plays an exceptional role in the modern nuclear engineering, especially in detection of hazardous substances. However, in the aquatic environment, there are still many problems to be solved for effective usage of this technique. We present status of SABAT (Stoichiometry Analysis By Activation Techniques), one of the projects aiming at construction of an underw…
▽ More
The Neutron Activation Analysis (NAA) plays an exceptional role in the modern nuclear engineering, especially in detection of hazardous substances. However, in the aquatic environment, there are still many problems to be solved for effective usage of this technique. We present status of SABAT (Stoichiometry Analysis By Activation Techniques), one of the projects aiming at construction of an underwater device for non-invasive threat detection based on the NAA.
△ Less
Submitted 21 November, 2017;
originally announced November 2017.
-
Human Tissues Investigation Using PALS Technique
Authors:
B. Jasińska,
B. Zgardzińska,
G. Chołubek,
M. Gorgol,
K. Wiktor,
K. Wysogld,
P. Białas,
C. Curceanu,
E. Czerwiński,
K. Dulski,
A. Gajos,
B. Głowacz,
B. Hiesmayr,
B. Jodłowska-Jędrych,
D. Kamińska,
G. Korcyl,
P. Kowalski,
T. Kozik,
N. Krawczyk,
W. Krzemień,
E. Kubicz,
M. Mohammed,
M. Pawlik-Niedźwiecka,
S. Niedźwiecki,
M. Pałka
, et al. (12 additional authors not shown)
Abstract:
Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorou…
▽ More
Samples of uterine leiomyomatis and normal tissues taken from patients after surgery were investigated using the Positron Annihilation Lifetime Spectroscopy (PALS). Significant differences in all PALS parameters between normal and diseased tissues were observed. For all studied patients, it was found that the values of the free annihilation and ortho-positronium lifetime are larger for the tumorous tissues than for the healthy ones. For most of the patients, the intensity of the free annihilation and ortho-positronium annihilation was smaller for the tumorous than for the healthy tissues. For the first time, in this kind of studies, the $3γ$ fraction of positron annihilation was determined to describe changes in the tissue porosity during morphologic alteration.
△ Less
Submitted 13 November, 2017;
originally announced November 2017.
-
Combination of KLOE $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ measurements and determination of $a_μ^{π^+π^-}$ in the energy range $0.10 < s < 0.95$ GeV$^2$
Authors:
The KLOE-2 Collaboration,
:,
A. Anastasi,
D. Babusci,
M. Berlowski,
C. Bloise,
F. Bossi,
P. Branchini,
A. Budano,
L. Caldeira Balkeståhl,
B. Cao,
F. Ceradini,
P. Ciambrone,
F. Curciarello,
E. Czerwiński,
G. D'Agostini,
E. Danè,
V. De Leo,
E. De Lucia,
A. De Santis,
P. De Simone,
A. Di Cicco,
A. Di Domenico,
D. Domenici,
A. D'Uffizi
, et al. (41 additional authors not shown)
Abstract:
The three precision measurements of the cross section $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of thes…
▽ More
The three precision measurements of the cross section $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$ using initial state radiation by the KLOE collaboration provide an important input for the prediction of the hadronic contribution to the anomalous magnetic moment of the muon. These measurements are correlated for both statistical and systematic uncertainties and, therefore, the simultaneous use of these measurements requires covariance matrices that fully describe the correlations. We present the construction of these covariance matrices and use them to determine a combined KLOE measurement for $σ\big(e^+e^-\rightarrowπ^+π^-γ(γ)\big)$. We find, from this combination, a two-pion contribution to the muon magnetic anomaly in the energy range $0.10 < s < 0.95$ GeV$^2$ of $a_μ^{π^+π^-} = (489.8 \pm 1.7_{\rm stat} \pm 4.8_{\rm sys} ) \times 10^{-10}$.
△ Less
Submitted 8 June, 2018; v1 submitted 8 November, 2017;
originally announced November 2017.