-
Strong Interaction Physics at the Luminosity Frontier with 22 GeV Electrons at Jefferson Lab
Authors:
A. Accardi,
P. Achenbach,
D. Adhikari,
A. Afanasev,
C. S. Akondi,
N. Akopov,
M. Albaladejo,
H. Albataineh,
M. Albrecht,
B. Almeida-Zamora,
M. Amaryan,
D. Androić,
W. Armstrong,
D. S. Armstrong,
M. Arratia,
J. Arrington,
A. Asaturyan,
A. Austregesilo,
H. Avagyan,
T. Averett,
C. Ayerbe Gayoso,
A. Bacchetta,
A. B. Balantekin,
N. Baltzell,
L. Barion
, et al. (419 additional authors not shown)
Abstract:
This document presents the initial scientific case for upgrading the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLab) to 22 GeV. It is the result of a community effort, incorporating insights from a series of workshops conducted between March 2022 and April 2023. With a track record of over 25 years in delivering the world's most intense and precise multi-GeV electron…
▽ More
This document presents the initial scientific case for upgrading the Continuous Electron Beam Accelerator Facility (CEBAF) at Jefferson Lab (JLab) to 22 GeV. It is the result of a community effort, incorporating insights from a series of workshops conducted between March 2022 and April 2023. With a track record of over 25 years in delivering the world's most intense and precise multi-GeV electron beams, CEBAF's potential for a higher energy upgrade presents a unique opportunity for an innovative nuclear physics program, which seamlessly integrates a rich historical background with a promising future. The proposed physics program encompass a diverse range of investigations centered around the nonperturbative dynamics inherent in hadron structure and the exploration of strongly interacting systems. It builds upon the exceptional capabilities of CEBAF in high-luminosity operations, the availability of existing or planned Hall equipment, and recent advancements in accelerator technology. The proposed program cover various scientific topics, including Hadron Spectroscopy, Partonic Structure and Spin, Hadronization and Transverse Momentum, Spatial Structure, Mechanical Properties, Form Factors and Emergent Hadron Mass, Hadron-Quark Transition, and Nuclear Dynamics at Extreme Conditions, as well as QCD Confinement and Fundamental Symmetries. Each topic highlights the key measurements achievable at a 22 GeV CEBAF accelerator. Furthermore, this document outlines the significant physics outcomes and unique aspects of these programs that distinguish them from other existing or planned facilities. In summary, this document provides an exciting rationale for the energy upgrade of CEBAF to 22 GeV, outlining the transformative scientific potential that lies within reach, and the remarkable opportunities it offers for advancing our understanding of hadron physics and related fundamental phenomena.
△ Less
Submitted 24 August, 2023; v1 submitted 13 June, 2023;
originally announced June 2023.
-
Electron Accelerator for Radiation Therapy with Beam Energy 6-20 MeV
Authors:
L. Yu. Ovchinnikova,
V. I. Shvedunov
Abstract:
Purpose: To describe a concept of a compact electron accelerator for external radiation therapy with variable energy in the range of 6 - 20 MeV, based on linotron principle. Methods: Beam dynamics simulation using the CST and MAD-X code. Various optimization methods of multi-parameter problem. Results: Our accelerator differs from the Reflexotron in a number of essential details: a much more compa…
▽ More
Purpose: To describe a concept of a compact electron accelerator for external radiation therapy with variable energy in the range of 6 - 20 MeV, based on linotron principle. Methods: Beam dynamics simulation using the CST and MAD-X code. Various optimization methods of multi-parameter problem. Results: Our accelerator differs from the Reflexotron in a number of essential details: a much more compact and more efficient C-band accelerating structure, optimized for the high capture efficiency, narrow energy and phase spectra, and low transverse emittance; magnetic mirror with fixed field based on rare-earth permanent magnets; three-electrode electron gun with off-axis placement of the cathode with a current regulated in the range of two orders of magnitude. These improvements allow the possibility to: adjust the accelerated beam current in a wide range in accordance with the required energy; reduce parasitic losses of the beam current and the associated parasitic radiation; eliminate the risk of setting an erroneous energy value; significantly reduce the dimensions of the accelerator and simplify its operation. Conclusions: We presented the results of calculation of the electron accelerator for external radiation therapy in the energy range of 6 - 20 MeV. The accelerator is based on the principle of double beam acceleration in the same accelerating structure, which allows to control the beam energy in a wide range, reduce RF power consumption and the dimensions of the accelerator, and, therefore, reduce its cost. The results can be used to develop the design of the accelerator on the platform of the KLT-6 complex created by ROSATOM.
△ Less
Submitted 2 August, 2020; v1 submitted 12 July, 2020;
originally announced July 2020.
-
Design study of compact Laser-Electron X-ray Generator for material and life science applications
Authors:
E. G. Bessonov,
M. V. Gorbunkov,
P. V. Kostrukov,
Yu. Ya. Maslova,
V. G. Tunkin,
A. A. Postnov,
A. A. Mikhailichenko,
V. I. Shvedunov,
B. S. Ishkhanov,
A. V. Vinogradov
Abstract:
X-Ray generations utilizing Thomson scattering fill in the gap that exists between conventional and synchrotron-based X-ray sources. They are expected to be more intense than X-ray tubes and more compact, accessible and less expensive than synchrotron. In this work, two operation modes of Thomson X-ray source are documented: quasi CW(QCW) and a pulsed one are considered for material sciences and m…
▽ More
X-Ray generations utilizing Thomson scattering fill in the gap that exists between conventional and synchrotron-based X-ray sources. They are expected to be more intense than X-ray tubes and more compact, accessible and less expensive than synchrotron. In this work, two operation modes of Thomson X-ray source are documented: quasi CW(QCW) and a pulsed one are considered for material sciences and medical applications being implemented currently at Synchrotron Radiation (SR) facilities.
△ Less
Submitted 29 April, 2016;
originally announced April 2016.
-
Energy losses and efficiency of laser - electron X-ray generator for medical applications
Authors:
E. G. Bessonov,
R. M. Feshchenko,
M. V. Gorbunkov,
A. V. Vinogradov,
V. I. Shvedunov
Abstract:
A source of medical x-rays based on a 50 Mev storage ring and a quasi-continues picosecond laser is considered. It is shown that such generator produces useful X-ray flux with higher average power and higher efficiency than that of conventional X-ray tubes. The main energy losses are related to coherent synchrotron radiation. Taking this into account the required parameters of the storage ring a…
▽ More
A source of medical x-rays based on a 50 Mev storage ring and a quasi-continues picosecond laser is considered. It is shown that such generator produces useful X-ray flux with higher average power and higher efficiency than that of conventional X-ray tubes. The main energy losses are related to coherent synchrotron radiation. Taking this into account the required parameters of the storage ring and injector are determined.
△ Less
Submitted 3 May, 2004;
originally announced May 2004.
-
The coherent synchrotron radiation influence on the storage ring longitudinal beam dynamics
Authors:
E. G. Bessonov,
R. M. Feshchenko,
V. I. Shvedunov
Abstract:
We investigate influence on the storage ring beam dynamics of the coherent Synchrotron Radiation (SR) self fields produced by an electron bunch. We show that the maximum energy gain in the RF cavity must far exceed the energy loss of electrons due to the coherent SR.
We investigate influence on the storage ring beam dynamics of the coherent Synchrotron Radiation (SR) self fields produced by an electron bunch. We show that the maximum energy gain in the RF cavity must far exceed the energy loss of electrons due to the coherent SR.
△ Less
Submitted 30 April, 2004;
originally announced April 2004.