An efficient dosimetry method with a Faraday cup for small animal, small-field proton irradiation under conventional and ultra-high dose rates
Authors:
Abbas Husain,
Jeremiah Ryser,
Julia Pakela,
Menggui Huang,
Khayrullo Shoniyozov,
Francois Vander Stappen,
Costas Koumenis,
Lei Dong,
Yi Fan,
Eric Diffenderfer,
Wei Zou
Abstract:
Introduction: We developed and evaluated a method for dose calibration and monitoring under conventional and ultra-high dose rates for small animal experiments with small-field proton beams using a Faraday cup.
Methods: We determined a relationship between dose and optical density (OD) of EBT-XD Gafchromic film using scanned 10x10 cm2 proton pencil beams delivered at clinical dose rates; the dos…
▽ More
Introduction: We developed and evaluated a method for dose calibration and monitoring under conventional and ultra-high dose rates for small animal experiments with small-field proton beams using a Faraday cup.
Methods: We determined a relationship between dose and optical density (OD) of EBT-XD Gafchromic film using scanned 10x10 cm2 proton pencil beams delivered at clinical dose rates; the dose was measured with an Advanced Markus chamber. On a small animal proton irradiation platform, double-scattered pencil beams with 5 or 8 mm diameter brass collimation at conventional and ultra-high dose rates were delivered to the EBT-XD films. The proton fluence charges were collected by a Faraday cup placed downstream from the film. The average of the irradiated film ODs was related to the Faraday cup charges. A conversion from the Faraday cup charge to the average dose of the small-field proton beam was then obtained.
Results: The relationship between the small-field average profile dose and Faraday cup charge was established for 10 and 15 Gy mice FLASH experiments. The film OD was found to be independent of dose rate. At small-animal treatments, the Faraday cup readings were conveniently used to QA and monitor the delivered dose and dose rates to the mice under conventional and ultra-high dose rates.
Conclusion: The dose calibration and monitoring method with Faraday cup for small animal proton FLASH experiments is time-efficient and cost-effective and can be used for irradiations of various small field sizes. The same approach can also be adopted for clinical proton dosimetry for small-field irradiations.
△ Less
Submitted 15 September, 2022;
originally announced September 2022.
-
Improving the efficiency of small animal 3D printed compensator IMRT with beamlet intensity total variation regularization
Authors:
Xinmin Liu,
Alexander L. Van Slyke,
Erik Pearson,
Khayrullo Shoniyozov,
Gage Redler,
Rodney D. Wiersma
Abstract:
Purpose: There is growing interest in the use of modern 3D printing technology to implement intensity-modulated radiation therapy (IMRT) on the preclinical scale which is analogous to clinical IMRT. However, current 3D-printed IMRT methods suffer from complex modulation patterns leading to long delivery times, excess filament usage, and inaccurate compensator fabrication. In this work, we have dev…
▽ More
Purpose: There is growing interest in the use of modern 3D printing technology to implement intensity-modulated radiation therapy (IMRT) on the preclinical scale which is analogous to clinical IMRT. However, current 3D-printed IMRT methods suffer from complex modulation patterns leading to long delivery times, excess filament usage, and inaccurate compensator fabrication. In this work, we have developed a total variation regularization (TVR) approach to address these issues.
Methods: TVR-IMRT, a technique designed to minimize the intensity difference between neighboring beamlets, was used to optimize the beamlet intensity map, which was then converted to corresponding compensator thicknesses in copper-doped PLA filament. IMRT and TVR-IMRT plans using five beams were generated to treat a mouse heart while sparing lung tissue. The individual field doses and composite dose were delivered to film and compared to the corresponding planned doses using gamma analysis.
Results: TVR-IMRT reduced the total variation of both the beamlet intensities and compensator thicknesses by around 50% when compared to standard 3D printed compensator IMRT. The total mass of compensator material consumed and radiation beam-on time were reduced by 20-30%, while DVHs remained comparable. Gamma analysis passing rate with 3%/0.3mm criterion was 89.07% for IMRT and 95.37% for TVR-IMRT.
Conclusion: TVR can be applied to small animal IMRT beamlet intensities in order to produce fluence maps and subsequent 3D-printed compensator patterns with less total variation, simplifying 3D printing and reducing the amount of filament required. The TVR-IMRT plan required less beam-on time while maintaining the dose conformity when compared to a traditional IMRT plan.
△ Less
Submitted 27 July, 2021; v1 submitted 1 July, 2021;
originally announced July 2021.
-
Compton scattering from 12C using tagged photons in the energy range 65 - 115 MeV
Authors:
L. S. Myers,
K. Shoniyozov,
M. F. Preston,
M. D. Anderson,
J. R. M. Annand,
M. Boselli,
W. J. Briscoe,
J. Brudvik,
J. I. Capone,
G. Feldman,
K. G. Fissum,
K. Hansen,
S. S. Henshaw,
L. Isaksson,
R. Jebali,
M. A. Kovash,
K. Lewis,
M. Lundin,
I. J. D. MacGregor,
D. G. Middleton,
D. E. Mittelberger,
M. Murray,
A. M. Nathan,
S. Nutbeam,
G. V. O'Rielly
, et al. (4 additional authors not shown)
Abstract:
Elastic scattering of photons from 12C has been investigated using quasi-monoenergetic tagged photons with energies in the range 65 - 115 MeV at laboratory angles of 60 deg, 120 deg, and 150 deg at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the 12C(g,g)12C cross section to the bound-nucleon…
▽ More
Elastic scattering of photons from 12C has been investigated using quasi-monoenergetic tagged photons with energies in the range 65 - 115 MeV at laboratory angles of 60 deg, 120 deg, and 150 deg at the Tagged-Photon Facility at the MAX IV Laboratory in Lund, Sweden. A phenomenological model was employed to provide an estimate of the sensitivity of the 12C(g,g)12C cross section to the bound-nucleon polarizabilities.
△ Less
Submitted 16 January, 2014;
originally announced January 2014.
-
Measurement of the Neutron-Proton and Neutron-Carbon Total Cross Section from 150 to 800 keV
Authors:
B. H. Daub,
V. Henzl,
M. A. Kovash,
J. L. Matthews,
Z. W. Miller,
K. Shoniyozov,
H. Yang
Abstract:
There have been very few measurements of the total cross section for np scattering below 500 keV. In order to differentiate among NN potential models, improved cross section data between 20 and 600 keV are required. We measured the np and nC total cross sections in this energy region by transmission; a collimated neutron beam was passed through CH2 and C samples and transmitted neutrons were detec…
▽ More
There have been very few measurements of the total cross section for np scattering below 500 keV. In order to differentiate among NN potential models, improved cross section data between 20 and 600 keV are required. We measured the np and nC total cross sections in this energy region by transmission; a collimated neutron beam was passed through CH2 and C samples and transmitted neutrons were detected by a BC-501A liquid scintillator. Cross sections were obtained with a precision of 1.1-2.0% between 150 and 800 keV using ratios of normalized neutron yields measured with and without the scattering samples in the beam. In energy regions where they overlap, the present results are consistent with existing precision measurements, and fill in a significant gap in the data between En = 150 and 500 keV.
△ Less
Submitted 28 January, 2013; v1 submitted 9 November, 2012;
originally announced November 2012.