Improved limits on $β^+$EC and ECEC processes in $^{74}$Se
Authors:
A. S. Barabash,
V. B. Brudanin,
A. A. Klimenko,
S. I. Konovalov,
A. V. Rakhimov,
E. N. Rukhadze,
N. I. Rukhadze,
Yu. A. Shitov,
I. Stekl,
G. Warot,
V. I. Umatov
Abstract:
New limits on $β^+$EC and ECEC processes in $^{74}$Se have been obtained using a 600 cm$^3$ HPGe detector and an external source consisting of 1600 g of a natural selenium powder. For different $β^+$EC and ECEC transitions (to the ground and excited states) obtained limits are on the level $\sim (0.2-4.8)\times10^{19}$ yr at 90\% C.L. In particular, for the potentially resonant transition into the…
▽ More
New limits on $β^+$EC and ECEC processes in $^{74}$Se have been obtained using a 600 cm$^3$ HPGe detector and an external source consisting of 1600 g of a natural selenium powder. For different $β^+$EC and ECEC transitions (to the ground and excited states) obtained limits are on the level $\sim (0.2-4.8)\times10^{19}$ yr at 90\% C.L. In particular, for the potentially resonant transition into the 1204.2 keV excited state of $^{74}$Ge a lower half-life limit of $1.1\times10^{19}$ yr at 90\% C.L. has been obtained. Possibility to increase the sensitivity of such measurements is discussed.
△ Less
Submitted 20 January, 2020;
originally announced January 2020.
-
A novel segmented-scintillator antineutrino detector
Authors:
Y. Abreu,
Y. Amhis,
L. Arnold,
G. Ban,
W. Beaumont,
M. Bongrand,
D. Boursette,
J. M. Buhour,
B. C. Castle,
K. Clark,
B. Coupé,
A. S. Cucoanes,
D. Cussans,
A. De Roeck,
J. DHondt,
D. Durand,
M. Fallot,
S. Fresneau,
L. Ghys,
L. Giot,
B. Guillon,
G. Guilloux,
S. Ihantola,
X. Janssen,
S. Kalcheva
, et al. (31 additional authors not shown)
Abstract:
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator technology. The detector target uses cubes of polyvinyltoluene interleaved with $^6$LiF:ZnS(Ag) phosphor screens to detect the products of the inverse beta decay re…
▽ More
The next generation of very-short-baseline reactor experiments will require compact detectors operating at surface level and close to a nuclear reactor. This paper presents a new detector concept based on a composite solid scintillator technology. The detector target uses cubes of polyvinyltoluene interleaved with $^6$LiF:ZnS(Ag) phosphor screens to detect the products of the inverse beta decay reaction. A multi-tonne detector system built from these individual cells can provide precise localisation of scintillation signals, making efficient use of the detector volume. Monte Carlo simulations indicate that a neutron capture efficiency of over 70% is achievable with a sufficient number of $^6$LiF:ZnS(Ag) screens per cube and that an appropriate segmentation enables a measurement of the positron energy which is not limited by gamma-ray leakage. First measurements of a single cell indicate that a very good neutron-gamma discrimination and high neutron detection efficiency can be obtained with adequate triggering techniques. The light yield from positron signals has been measured, showing that an energy resolution of 14%/$\sqrt{E({\mathrm{MeV}})}$ is achievable with high uniformity. A preliminary neutrino signal analysis has been developed, using selection criteria for pulse shape, energy, time structure and energy spatial distribution and showing that an antineutrino efficiency of 40% can be achieved. It also shows that the fine segmentation of the detector can be used to significantly decrease both correlated and accidental backgrounds.
△ Less
Submitted 31 May, 2017; v1 submitted 5 March, 2017;
originally announced March 2017.
-
A Search for Neutrinoless Double Beta Decay: from NEMO-3 to SuperNEMO
Authors:
Yu. A. Shitov
Abstract:
The SuperNEMO project aims to search for neutrinoless double beta decay ($0νββ$) up to a sensitivity of 10$^{26}$ years for the $0νββ$ half-life (down to $\sim$ 50~meV in the effective Majorana neutrino mass), using $\sim$100 kg of source and a `tracko-calo' detector. The current status of the 2006--2010 R\&D programme is discussed here.
The SuperNEMO project aims to search for neutrinoless double beta decay ($0νββ$) up to a sensitivity of 10$^{26}$ years for the $0νββ$ half-life (down to $\sim$ 50~meV in the effective Majorana neutrino mass), using $\sim$100 kg of source and a `tracko-calo' detector. The current status of the 2006--2010 R\&D programme is discussed here.
△ Less
Submitted 28 June, 2010; v1 submitted 24 June, 2010;
originally announced June 2010.
-
Results of the BiPo-1 prototype for radiopurity measurements for the SuperNEMO double beta decay source foils
Authors:
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
A. Basharina-Freshville,
M. Bongrand,
C. Bourgeois,
D. Breton,
M. Briére,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
J. Díaz,
D. Durand,
V. G. Egorov,
J. J. Evans,
R. Flack,
K-I. Fushima,
I. G. Irastorza,
X. Garrido
, et al. (64 additional authors not shown)
Abstract:
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the backg…
▽ More
The development of BiPo detectors is dedicated to the measurement of extremely high radiopurity in $^{208}$Tl and $^{214}$Bi for the SuperNEMO double beta decay source foils. A modular prototype, called BiPo-1, with 0.8 $m^2$ of sensitive surface area, has been running in the Modane Underground Laboratory since February, 2008. The goal of BiPo-1 is to measure the different components of the background and in particular the surface radiopurity of the plastic scintillators that make up the detector. The first phase of data collection has been dedicated to the measurement of the radiopurity in $^{208}$Tl. After more than one year of background measurement, a surface activity of the scintillators of $\mathcal{A}$($^{208}$Tl) $=$ 1.5 $μ$Bq/m$^2$ is reported here. Given this level of background, a larger BiPo detector having 12 m$^2$ of active surface area, is able to qualify the radiopurity of the SuperNEMO selenium double beta decay foils with the required sensitivity of $\mathcal{A}$($^{208}$Tl) $<$ 2 $μ$Bq/kg (90% C.L.) with a six month measurement.
△ Less
Submitted 3 May, 2010;
originally announced May 2010.
-
Spectral modeling of scintillator for the NEMO-3 and SuperNEMO detectors
Authors:
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
M. Bongrand,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
S. Cebrián,
A. Chapon,
E. Chauveau,
Th. Dafni,
Z. Daraktchieva,
J. D iaz,
D. Durand,
V. G. Egorov,
J. J. Evans,
N. Fatemi-Ghomi,
R. Flack,
A. Basharina-Freshville,
K-I. Fushimi,
X. Garrido,
H. Gómez,
B. Guillon
, et al. (68 additional authors not shown)
Abstract:
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is im…
▽ More
We have constructed a GEANT4-based detailed software model of photon transport in plastic scintillator blocks and have used it to study the NEMO-3 and SuperNEMO calorimeters employed in experiments designed to search for neutrinoless double beta decay. We compare our simulations to measurements using conversion electrons from a calibration source of $\rm ^{207}Bi$ and show that the agreement is improved if wavelength-dependent properties of the calorimeter are taken into account. In this article, we briefly describe our modeling approach and results of our studies.
△ Less
Submitted 8 November, 2010; v1 submitted 21 April, 2010;
originally announced April 2010.
-
Measurement of the background in the NEMO 3 double beta decay experiment
Authors:
NEMO Collaboration,
J. Argyriades,
R. Arnold,
C. Augier,
J. Baker,
A. S. Barabash,
M. Bongrand,
G. Broudin-Bay,
V. B. Brudanin,
A. J. Caffrey,
A. Chapon,
E. Chauveau,
Z. Daraktchieva,
D. Durand,
V. G. Egorov,
N. Fatemi-Ghomi,
R. Flack,
A. Freshville,
B. Guillon,
Ph. Hubert,
S. Jullian,
M. Kauer,
S. King,
O. I. Kochetov,
S. I. Konovalov
, et al. (40 additional authors not shown)
Abstract:
In the double beta decay experiment NEMO~3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the methods used in NEMO~3 to evaluate the backgrounds resulting from most if not all possible origins. It also illustrates the power of the combined tracking-calorimetry technique used in the experiment.
In the double beta decay experiment NEMO~3 a precise knowledge of the background in the signal region is of outstanding importance. This article presents the methods used in NEMO~3 to evaluate the backgrounds resulting from most if not all possible origins. It also illustrates the power of the combined tracking-calorimetry technique used in the experiment.
△ Less
Submitted 12 March, 2009;
originally announced March 2009.