SliT: A Strip-sensor Readout Chip with Subnanosecond Time-walk for the J-PARC Muon $g-2$/EDM Experiment
Authors:
Tetsuichi Kishishita,
Yutaro Sato,
Yoichi Fujita,
Eitaro Hamada,
Tsutomu Mibe,
Tsubasa Nagasawa,
Shohei Shirabe,
Masayoshi Shoji,
Taikan Suehara,
Manobu M. Tanaka,
Junji Tojo,
Yuki Tsutumi,
Takashi Yamanaka,
Tamaki Yoshioka
Abstract:
A new silicon-strip readout chip named "SliT" has been developed for the measurement of the muon anomalous magnetic moment and electric dipole moment at J-PARC. The SliT is designed in the Silterra 180 nm CMOS technology with mixed-signal integrated circuits. An analog circuit incorporates a conventional charge-sensitive amplifier, sha** amplifiers, and two distinct discriminators for each of 12…
▽ More
A new silicon-strip readout chip named "SliT" has been developed for the measurement of the muon anomalous magnetic moment and electric dipole moment at J-PARC. The SliT is designed in the Silterra 180 nm CMOS technology with mixed-signal integrated circuits. An analog circuit incorporates a conventional charge-sensitive amplifier, sha** amplifiers, and two distinct discriminators for each of 128 identical channels. A digital part includes storage memories, an event building block, a serializer, and LVDS drivers. A distinct feature of the SliT is utilization of the zero-cross architecture, which consists of a CR-RC filter followed by a CR circuit as a voltage differentiator. This architecture enables to generate hit signals with subnanosecond amplitude-independent time walk, which is the primary requirement for the experiment. The test results show the time walk of $0.38 \pm 0.16$ ns between 0.5 and 3 MIP signals. The equivalent noise charge is $1547 \pm 75 $ $e^{-}$ (rms) at $C_{\rm det} = 33$ pF as a strip-sensor capacitance. Other functionalities such as a strip-sensor readout chip have also been proven in the tests. The SliT128C satisfies all requirements of the J-PARC muon $g-2$/EDM experiment.
△ Less
Submitted 28 July, 2020; v1 submitted 14 June, 2020;
originally announced June 2020.
-
Performance evaluation of a silicon strip detector for positrons/electrons from a pulsed a muon beam
Authors:
T. Aoyagi,
Y. Honda,
H. Ikeda,
M. Ikeno,
K. Kawagoe,
T. Kohriki,
T. Kume,
T. Mibe,
K. Namba,
S. Nishimura,
N. Saito,
O. Sasaki,
N. Sato,
Y. Sato,
H. Sendai,
K. Shimomura,
S. Shirabe,
M. Shoji,
T. Suda,
T. Suehara,
T. Takatomi,
M. Tanaka,
J. Tojo,
K. Tsukada,
T. Uchida
, et al. (4 additional authors not shown)
Abstract:
A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positr…
▽ More
A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positrons from muon decay. Fine segmentation is required in a detector to tolerate the high rate of positrons. The time resolution is required to be much better than the muon anomalous spin precession period while a buffer depth of a front-end electronics needs to be much longer than the accelerated muon lifetime. Requirements of this detector also meet requirements of a measurement of the muonium hyperfine structure interval at the J-PARC and another experiment to measure the proton charge radius at Tohoku University. We have developed a single-sided silicon strip sensor with a 190 $μ$m pitch, a front-end electronics with a sampling rate of 200 MHz and a buffer memory depth of 8192, and a data acquisition system based on DAQ-Middleware for the J-PARC muon $g-2$/EDM experiment. We have fabricated detector modules consisting of this sensor and the front-end electronics. Performance of fabricated detector modules was evaluated at a laboratory and a beam test using the positron beam at Tohoku University. The detector is confirmed to satisfy all requirements of the experiments except for the time walk, which will be solved by the next version of a front-end electronics.
△ Less
Submitted 7 May, 2020; v1 submitted 29 October, 2019;
originally announced October 2019.
-
Time resolution of time-of-flight detector based on multiple scintillation counters readout by SiPMs
Authors:
P. W. Cattaneo,
M. De Gerone,
F. Gatti,
M. Nishimura,
W. Ootani,
M. Rossella,
S. Shirabe,
Y. Uchiyama
Abstract:
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $σ_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV…
▽ More
A new timing detector measuring ~50 MeV/c positrons is under development for the MEG II experiment, aiming at a time resolution $σ_t \sim 30~\mathrm{ps}$. The resolution is expected to be achieved by measuring each positron time with multiple counters made of plastic scintillator readout by silicon photomultipliers (SiPMs). The purpose of this work is to demonstrate the time resolution for ~50 MeV/c positrons using prototype counters. Counters with dimensions of $90\times 40\times 5~\mathrm{mm}^3$ readout by six SiPMs (three on each $40\times 5~\mathrm{mm}^2$ plane) were built with SiPMs from Hamamatsu Photonics and AdvanSiD and tested in a positron beam at the DA$Φ$NE Beam Test Facility. The time resolution was found to improve nearly as the square root of the number of counter hits. A time resolution $σ_t=26.2\pm1.3~\mathrm{ps}$ was obtained with eight counters with Hamamatsu SiPMs. These results suggest that the design resolution is achievable in the MEG II experiment.
△ Less
Submitted 20 May, 2016; v1 submitted 12 November, 2015;
originally announced November 2015.
-
Design and test of an extremely high resolution Timing Counter for the MEG II experiment: preliminary results
Authors:
M. De Gerone,
F. Gatti,
W. Ootani,
Y. Uchiyama,
M. Nishimura,
S. Shirabe,
P. W. Cattaneo,
M. Rossella
Abstract:
The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facili…
▽ More
The design and tests of Timing Counter elements for the upgrade of the MEG experiment, MEG II,is presented. The detector is based on several small plates of scintillator with a Silicon PhotoMultipliers dual-side readout. The optimisation of the single counter elements (SiPMs, scintillators, geometry) is described. Moreover, the results obtained with a first prototype tested at the Beam Test Facility (BTF) of the INFN Laboratori Nazionali di Frascati (LNF) are presented.
△ Less
Submitted 7 January, 2014; v1 submitted 3 December, 2013;
originally announced December 2013.