-
Diamond quantum magnetometer with dc sensitivity of < 10 pT Hz$^{-1/2}$ toward measurement of biomagnetic field
Authors:
N. Sekiguchi,
M. Fushimi,
A. Yoshimura,
C. Shinei,
M. Miyakawa,
T. Taniguchi,
T. Teraji,
H. Abe,
S. Onoda,
T. Ohshima,
M. Hatano,
M. Sekino,
T. Iwasaki
Abstract:
We present a sensitive diamond quantum sensor with a magnetic field sensitivity of $9.4 \pm 0.1~\mathrm{pT/\sqrt{Hz}}$ in a near-dc frequency range of 5 to 100~Hz. This sensor is based on the continuous-wave optically detected magnetic resonance of an ensemble of nitrogen-vacancy centers along the [111] direction in a diamond (111) single crystal. The long $T_{2}^{\ast} \sim 2~\mathrm{μs}$ in our…
▽ More
We present a sensitive diamond quantum sensor with a magnetic field sensitivity of $9.4 \pm 0.1~\mathrm{pT/\sqrt{Hz}}$ in a near-dc frequency range of 5 to 100~Hz. This sensor is based on the continuous-wave optically detected magnetic resonance of an ensemble of nitrogen-vacancy centers along the [111] direction in a diamond (111) single crystal. The long $T_{2}^{\ast} \sim 2~\mathrm{μs}$ in our diamond and the reduced intensity noise in laser-induced fluorescence result in remarkable sensitivity among diamond quantum sensors. Based on an Allan deviation analysis, we demonstrate that a sub-picotesla field of 0.3~pT is detectable by interrogating the magnetic field for a few thousand seconds. The sensor head is compatible with various practical applications and allows a minimum measurement distance of about 1~mm from the sensing region. The proposed sensor facilitates the practical application of diamond quantum sensors.
△ Less
Submitted 7 September, 2023;
originally announced September 2023.
-
Long Rayleigh length confocal microscope: A fast evaluation tool for obtaining quantum properties of color centers
Authors:
Yuta Masuyama,
Chikara Shinei,
Shuya Ishii,
Hiroshi Abe,
Takashi Taniguchi,
Tokuyuki Teraji,
Takeshi Ohshima
Abstract:
Color centers in wide band-gap semiconductors, which have superior quantum properties even at room temperature and atmospheric pressure, have been actively applied to quantum sensing devices. Characterization of the quantum properties of the color centers in the semiconductor materials and ensuring that these properties are uniform over a wide area are key issues for develo** quantum sensing dev…
▽ More
Color centers in wide band-gap semiconductors, which have superior quantum properties even at room temperature and atmospheric pressure, have been actively applied to quantum sensing devices. Characterization of the quantum properties of the color centers in the semiconductor materials and ensuring that these properties are uniform over a wide area are key issues for develo** quantum sensing devices based on color center. In this article, we will describe the principle and performance of a newly developed confocal microscope system with a long Rayleigh length (LRCFM). This system can characterize a wider area faster than the confocal microscope systems commonly used for color center evaluation.
△ Less
Submitted 28 April, 2023; v1 submitted 29 January, 2023;
originally announced January 2023.
-
Millimetre-scale magnetocardiography of living rats using a solid-state quantum sensor
Authors:
Keigo Arai,
Akihiro Kuwahata,
Daisuke Nishitani,
Ikuya Fujisaki,
Ryoma Matsuki,
Zhonghao Xin,
Yuki Nishio,
Xinyu Cao,
Yuji Hatano,
Shinobu Onoda,
Chikara Shinei,
Masashi Miyakawa,
Takashi Taniguchi,
Masatoshi Yamazaki,
Tokuyuki Teraji,
Takeshi Ohshima,
Mutsuko Hatano,
Masaki Sekino,
Takayuki Iwasaki
Abstract:
A key challenge in cardiology is the non-invasive imaging of electric current propagation occurring in the cardiovascular system at an intra-cardiac scale. A promising approach for directly map** the current dynamics is to monitor the associated stray magnetic field. However, in this magnetic field approach, the spatial resolution deteriorates significantly as the standoff distance between the t…
▽ More
A key challenge in cardiology is the non-invasive imaging of electric current propagation occurring in the cardiovascular system at an intra-cardiac scale. A promising approach for directly map** the current dynamics is to monitor the associated stray magnetic field. However, in this magnetic field approach, the spatial resolution deteriorates significantly as the standoff distance between the target and the sensor increases. Existing sensors usually remain relatively far from the target and provide only centimetre-scale resolution because their operating temperature is not biocompatible. Here we demonstrate millimetre-scale magnetocardiography of living rats using a solid-state quantum sensor based on nitrogen-vacancy centres in diamond. The essence of the method is a millimetre proximity from the sensor to heart surface, which enhances the cardiac magnetic field to greater than nanoteslas and allows the map** of these signals with intra-cardiac resolution. From the acquired magnetic images, we also estimate the source electric current vector, flowing from the right atria base via the Purkinje fibre bundle to the left ventricular apex. Our results establish the solid-state quantum sensor's capability to probe cardiac magnetic signals from mammalian animals and reveal their intra-cardiac electrodynamics. This technique will enable the study of the origin and progression of myriad cardiac arrhythmias including flutter, fibrillation, and tachycardia.
△ Less
Submitted 25 May, 2021;
originally announced May 2021.