  1. arXiv:1305.7336  [pdf, other

    physics.ins-det hep-ex

    Apparatus for Measurement of the Electric Dipole Moment of the Neutron using a Cohabiting Atomic-Mercury Magnetometer

    Authors: C. A. Baker, Y. Chibane, M. Chouder, P. Geltenbort, K. Green, P. G. Harris, B. R. Heckel, P. Iaydjiev, S. N. Ivanov, I. Kilvington, S. K. Lamoreaux, D. J. May, J. M. Pendlebury, J. D. Richardson, D. B. Shiers, K. F. Smith, M. van der Grinten

    Abstract: A description is presented of apparatus used to carry out an experimental search for an electric dipole moment of the neutron, at the Institut Laue-Langevin (ILL), Grenoble. The experiment incorporated a cohabiting atomic-mercury magnetometer in order to reduce spurious signals from magnetic field fluctuations. The result has been published in an earlier letter; here, the methods and equipment use… ▽ More

    Submitted 5 June, 2013; v1 submitted 31 May, 2013; originally announced May 2013.

  2. arXiv:0709.2428  [pdf

    hep-ex

    A Proposal for a Cryogenic Experiment to Measure the Neutron Electric Dipole Moment (nEDM)

    Authors: S. N. Balashov, K. Green, M. G. D. van der Grinten, P. G. Harris, H. Kraus, J. M. Pendlebury, D. B. Shiers, M. A. H. Tucker, D. L. Wark

    Abstract: This document is a copy of the original 2003 proposal for the construction grant for the CryoEDM Experiment at ILL, Grenoble. It is here made publicly available as a technical reference source for interested parties. It does not necessarily represent the final configuration of the experiment. Items pertaining to costs, personnel etc. have been removed.

    Submitted 17 September, 2007; originally announced September 2007.

    Comments: 34 pages