-
Water Cherenkov muon veto for the COSINUS experiment: design and simulation optimization
Authors:
G. Angloher,
M. R. Bharadwaj,
M. Cababie,
I. Dafinei,
N. Di Marco,
L. Einfalt,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
Z. Ge,
M. Heikinheimo,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro,
F. Pröbst,
G. Profeta,
A. Puiu,
F. Reindl
, et al. (14 additional authors not shown)
Abstract:
COSINUS is a dark matter (DM) direct search experiment that uses sodium iodide (NaI) crystals as cryogenic calorimeters. Thanks to the low nuclear recoil energy threshold and event-by-event discrimination capability, COSINUS will address the long-standing DM claim made by the DAMA/LIBRA collaboration. The experiment is currently under construction at the Laboratori Nazionali del Gran Sasso, Italy,…
▽ More
COSINUS is a dark matter (DM) direct search experiment that uses sodium iodide (NaI) crystals as cryogenic calorimeters. Thanks to the low nuclear recoil energy threshold and event-by-event discrimination capability, COSINUS will address the long-standing DM claim made by the DAMA/LIBRA collaboration. The experiment is currently under construction at the Laboratori Nazionali del Gran Sasso, Italy, and employs a large cylindrical water tank as a passive shield to meet the required background rate. However, muon-induced neutrons can mimic a DM signal therefore requiring an active veto system, which is achieved by instrumenting the water tank with an array of photomultiplier tubes (PMTs). This study optimizes the number, arrangement, and trigger conditions of the PMTs as well as the size of an optically invisible region. The objective was to maximize the muon veto efficiency while minimizing the accidental trigger rate due to the ambient and instrumental background. The final configuration predicts a veto efficiency of 99.63 $\pm$ 0.16 $\%$ and 44.4 $\pm$ $5.6\%$ in the tagging of muon events and showers of secondary particles, respectively. The active veto will reduce the cosmogenic neutron background rate to 0.11 $\pm$ 0.02 cts$\cdot$kg$^{-1}$$\cdot$year$^{-1}$, corresponding to less than one background event in the region of interest for the whole COSINUS-1$π$ exposure of 1000 kg$\cdot$days.
△ Less
Submitted 25 April, 2024;
originally announced June 2024.
-
Dark Matter-Electron Scattering Search Using Cryogenic Light Detectors
Authors:
V. Zema,
P. Figueroa,
G. Angloher,
M. R. Bharadwaj,
T. Frank,
M. N. Hughes,
M. Kellermann,
F. Pröbst,
K. Schäffner,
K. Shera,
M. Stahlberg
Abstract:
The CSC (cryogenic scintillating calorimeter) technology devoted to rare event searches is reaching the sensitivity level required for the hunt of dark matter-electron scatterings. Dark matter-electron interactions in scintillating targets are expected to stimulate the emission of single photons, each of energy equal to the target electronic band gap. The electronic band gap in scintillators like…
▽ More
The CSC (cryogenic scintillating calorimeter) technology devoted to rare event searches is reaching the sensitivity level required for the hunt of dark matter-electron scatterings. Dark matter-electron interactions in scintillating targets are expected to stimulate the emission of single photons, each of energy equal to the target electronic band gap. The electronic band gap in scintillators like NaI/GaAs is of O(eV). The search for this signal can be done by an array of cryogenic light detectors with eV/sub-eV energy resolution. In this work, we describe the detection principle, the detector response and the envisioned detector design to search for dark matter interacting with electrons via the measurement of the scintillation light at millikelvin. First sensitivity projections are provided, which show the potential of this research.
△ Less
Submitted 2 February, 2024;
originally announced February 2024.
-
Deep-underground dark matter search with a COSINUS detector prototype
Authors:
The COSINUS Collaboration,
G. Angloher,
M. R. Bharadwaj,
I. Dafinei,
N. Di Marco,
L. Einfalt,
F. Ferroni,
S. Fichtinger,
A. Filipponi,
T. Frank,
M. Friedl,
A. Fuss,
Z. Ge,
M. Heikinheimo,
M. N. Hughes,
K. Huitu,
M. Kellermann,
R. Maji,
M. Mancuso,
L. Pagnanini,
F. Petricca,
S. Pirro,
F. Proebst,
G. Profeta,
A. Puiu
, et al. (14 additional authors not shown)
Abstract:
Sodium iodide (NaI) based cryogenic scintillating calorimeters using quantum sensors for signal read out have shown promising first results towards a model-independent test of the annually modulating signal detected by the DAMA/LIBRA dark matter experiment. The COSINUS collaboration has previously reported on the first above-ground measurements using a dual channel readout of phonons and light bas…
▽ More
Sodium iodide (NaI) based cryogenic scintillating calorimeters using quantum sensors for signal read out have shown promising first results towards a model-independent test of the annually modulating signal detected by the DAMA/LIBRA dark matter experiment. The COSINUS collaboration has previously reported on the first above-ground measurements using a dual channel readout of phonons and light based on transition edge sensors (TESs) that allows for particle discrimination on an event-by-event basis. In this letter, we outline the first underground measurement of a NaI cryogenic calorimeter read out via the novel remoTES scheme. A 3.67 g NaI absorber with an improved silicon light detector design was operated at the Laboratori Nazionali del Gran Sasso, Italy. A significant improvement in the discrimination power of $e^-$/$γ$-events to nuclear recoils was observed with a five-fold improvement in the nuclear recoil baseline resolution, achieving $σ$ = 441 eV. Furthermore, we present a limit on the spin-independent dark-matter nucleon elastic scattering cross-section achieving a sensitivity of $\mathcal{O}$(pb) with an exposure of only 11.6 g d.
△ Less
Submitted 20 July, 2023;
originally announced July 2023.