Skip to main content

Showing 1–18 of 18 results for author: Shemyakina, E

.
  1. arXiv:1909.00619  [pdf, other

    physics.ins-det astro-ph.IM

    Electron transport and electric field simulations in two-phase detectors with THGEM electrodes

    Authors: Alexander Bondar, Alexei Buzulutskov, Egor Frolov, Vladislav Oleynikov, Ekaterina Shemyakina, Andrey Sokolov

    Abstract: One of the main features of two-phase detectors with electroluminescence (EL) gap being developed in our laboratory for dark matter search is the extensive use of THGEMs (Thick Gas Electron Multipliers). In various versions of the detector, the THGEMs are used as electrodes in the gas and liquid phases to form the drift, electron emission and EL regions, as well as for avalanche amplification of a… ▽ More

    Submitted 2 September, 2019; originally announced September 2019.

    Comments: 7 pages, 11 figures, 1 table

    Journal ref: Nucl. Instrum. Meth. A 943 (2019) 162431

  2. arXiv:1905.05502  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Neutral bremsstrahlung in two-phase argon electroluminescence: further studies and possible applications

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, E. Frolov, V. Nosov, V. Oleynikov, E. Shemyakina, A. Sokolov

    Abstract: We further study the effect of neutral bremsstrahlung (NBrS) in two-phase argon electroluminescence (EL), revealed recently in [1]. The absolute EL yield due to NBrS effect, in the visible and NIR range, was remeasured in pure gaseous argon in the two-phase mode, using a two-phase detector with EL gap read out directly by cryogenic PMTs and SiPMs. Possible applications of the NBrS effect in detect… ▽ More

    Submitted 14 May, 2019; originally announced May 2019.

    Comments: 4 pages, 5 figures, presented at VCI2019 conference, to be published in NIM A

  3. arXiv:1805.02839  [pdf, other

    physics.ins-det hep-ex

    Characterization of a 109Cd gamma-ray source for the two-phase argon detector

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, A. Legkodymov, V. Nosov, V. Oleynikov, V. Porosev, E. Shemyakina, A. Sokolov

    Abstract: At present, a two-phase argon detector is being developed in our laboratory for dark matter search and low-energy neutrino experiments. To calibrate its energy scale a $^{109}$Cd gamma-ray source was used. In this work a detailed emission spectrum of the $^{109}$Cd source was measured using YAP:Ce scintillator and high-purity germanium (HPGe) detectors. It is shown that the $^{109}$Cd source, equi… ▽ More

    Submitted 31 May, 2018; v1 submitted 8 May, 2018; originally announced May 2018.

    Comments: 7 pages, 4 figures, 1 table

  4. arXiv:1803.05329  [pdf, other

    physics.ins-det astro-ph.IM hep-ex

    Revealing neutral bremsstrahlung in two-phase argon electroluminescence

    Authors: A. Buzulutskov, E. Shemyakina, A. Bondar, A. Dolgov, E. Frolov, V. Nosov, V. Oleynikov, L. Shekhtman, A. Sokolov

    Abstract: Proportional electroluminescence (EL) in noble gases has long been used in two-phase detectors for dark matter search, to record ionization signals induced by particle scattering in the noble-gas liquid (S2 signals). Until recently, it was believed that proportional electroluminescence was fully due to VUV emission of noble gas excimers produced in atomic collisions with excited atoms, the latter… ▽ More

    Submitted 20 June, 2018; v1 submitted 13 March, 2018; originally announced March 2018.

    Comments: 14 pages, 21 figures. Version3: new several paragraphs and references and a new figure added

    Journal ref: Astroparticle Physics 103 (2018) 29

  5. DarkSide-20k: A 20 Tonne Two-Phase LAr TPC for Direct Dark Matter Detection at LNGS

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, M. Ave, H. O. Back, A. I. Barrado Olmedo, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino , et al. (260 additional authors not shown)

    Abstract: Building on the successful experience in operating the DarkSide-50 detector, the DarkSide Collaboration is going to construct DarkSide-20k, a direct WIMP search detector using a two-phase Liquid Argon Time Projection Chamber (LArTPC) with an active (fiducial) mass of 23 t (20 t). The DarkSide-20k LArTPC will be deployed within a shield/veto with a spherical Liquid Scintillator Veto (LSV) inside a… ▽ More

    Submitted 25 July, 2017; originally announced July 2017.

    Report number: FERMILAB-PUB-17-298-PPD

    Journal ref: Aalseth, C.E., Acerbi, F., Agnes, P. et al. Eur. Phys. J. Plus (2018) 133: 131

  6. Cryogenic Characterization of FBK RGB-HD SiPMs

    Authors: C. E. Aalseth, F. Acerbi, P. Agnes, I. F. M. Albuquerque, T. Alexander, A. Alici, A. K. Alton, P. Ampudia, P. Antonioli, S. Arcelli, R. Ardito, I. J. Arnquist, D. M. Asner, H. O. Back, G. Batignani, E. Bertoldo, S. Bettarini, M. G. Bisogni, V. Bocci, A. Bondar, G. Bonfini, W. Bonivento, M. Bossa, B. Bottino, R. Bunker , et al. (246 additional authors not shown)

    Abstract: We report on the cryogenic characterization of Red Green Blue - High Density (RGB-HD) SiPMs developed at Fondazione Bruno Kessler (FBK) as part of the DarkSide program of dark matter searches with liquid argon time projection chambers. A dedicated setup was used to measure the primary dark noise, the correlated noise, and the gain of the SiPMs at varying temperatures. A custom-made data acquisitio… ▽ More

    Submitted 12 September, 2017; v1 submitted 19 May, 2017; originally announced May 2017.

  7. arXiv:1705.05107  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Measurement of the ionization yield of nuclear recoils in liquid argon using a two-phase detector with electroluminescence gap

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, E. Grishnyaev, V. Nosov, V. Oleynikov, S. Polosatkin, L. Shekhtman, E. Shemyakina, A. Sokolov

    Abstract: A measurement of ionization yields in noble-gas liquids is relevant to the energy calibration of nuclear recoil detectors for dark matter search and coherent neutrino-nucleus scattering experiments. In this work we further study the ionization yield of nuclear recoils in liquid Ar, using a two-phase detector with an electroluminescence gap and DD neutron generator. The ionization yields of nuclear… ▽ More

    Submitted 15 May, 2017; originally announced May 2017.

    Comments: 10 pages, 8 figures, 1 table. Submitted to the Proceedings of the Instrumentation for Colliding Beam Physics (INSTR17) Conference. To be published in JINST

    Journal ref: JINST 12 (2017) C05010

  8. arXiv:1705.05101  [pdf, other

    astro-ph.IM hep-ex physics.ins-det

    Further studies of proportional electroluminescence in two-phase argon

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, E. Frolov, V. Nosov, V. Oleynikov, L. Shekhtman, E. Shemyakina, A. Sokolov

    Abstract: The study of proportional electroluminescence in two-phase argon is relevant in the field of noble-gas liquid detectors for dark matter search and low-energy neutrino experiments. In this work, we continued to study proportional electroluminescence (EL) in two-phase argon doped with a minor (9 ppm) admixture of nitrogen, in the VUV, UV and visible spectral ranges. We confirmed the effect of enhanc… ▽ More

    Submitted 15 May, 2017; originally announced May 2017.

    Comments: 12 pages, 7 figures, 1 table. Presented at Instrumentation for Colliding Beam Physics Conference (INSTR17). To be published in JINST

    Journal ref: JINST 12 (2017) C05016

  9. arXiv:1605.08729  [pdf, ps, other

    physics.ins-det hep-ex

    Two-phase Cryogenic Avalanche Detector with electroluminescence gap operated in argon doped with nitrogen

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, V. Nosov, L. Shekhtman, E. Shemyakina, A. Sokolov

    Abstract: A two-phase Cryogenic Avalanche Detector (CRAD) with electroluminescence (EL) gap, operated in argon doped with a minor (49$\pm$7 ppm) admixture of nitrogen, has been studied. The EL gap was optically read out using cryogenic PMTs located on the perimeter of the gap. We present the results of the measurements of the N$_2$ content, detector sensitivity to X-ray-induced signals, EL gap yield and ele… ▽ More

    Submitted 27 May, 2016; originally announced May 2016.

    Comments: 4 pages, 5 figures. Presented at Vienna Conference of Instrumentation (2016). To be published in Nucl. Instr. Meth. A

    Journal ref: Nucl. Instr. Meth. A 845 (2017) 206

  10. arXiv:1509.00664  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex

    Proportional electroluminescence in two-phase argon and its relevance to rare-event experiments

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, V. Nosov, L. Shekhtman, E. Shemyakina, A. Sokolov

    Abstract: Proportional electroluminescence (EL) in gaseous Ar has for the first time been systematically studied in the two-phase mode, at 87 K and 1.00 atm. Liquid argon had a minor (56 ppm) admixture of nitrogen, which allowed to understand, inter alia, the effect of N2 do** on the EL mechanism in rare-event experiments using two-phase Ar detectors. The measurements were performed in a two-phase Cryogen… ▽ More

    Submitted 20 October, 2015; v1 submitted 2 September, 2015; originally announced September 2015.

    Comments: 6 pages, 4 figures. Replaced to match journal version

    Journal ref: EPL, 112 (2015) 19001

  11. MPPC versus MRS APD in two-phase Cryogenic Avalanche Detectors

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, E. Shemyakina, A. Sokolov

    Abstract: Two-phase Cryogenic Avalanche Detectors (CRADs) with combined THGEM/GAPD multiplier have become an emerging potential technique for dark matter search and coherent neutrino-nucleus scattering experiments. In such a multiplier the THGEM hole avalanches are optically recorded in the Near Infrared (NIR) using a matrix of Geiger-mode APDs (GAPDs). To select the proper sensor, the performances of six G… ▽ More

    Submitted 12 February, 2015; originally announced February 2015.

    Comments: 11 pages, 8 figures. Submitted to JINST

    Journal ref: 2015 JINST 10 P04013

  12. arXiv:1407.7348  [pdf, ps, other

    physics.ins-det hep-ex nucl-ex

    Measurement of the ionization yield of nuclear recoils in liquid argon at 80 and 233 keV

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, E. Grishnyaev, S. Polosatkin, L. Shekhtman, E. Shemyakina, A. Sokolov

    Abstract: The energy calibration of nuclear recoil detectors is of primary importance to rare-event experiments such as those of direct dark matter search and coherent neutrino-nucleus scattering. In particular, such a calibration is performed by measuring the ionization yield of nuclear recoils in liquid Ar and Xe detection media, using neutron elastic scattering off nuclei. In the present work, the ioniza… ▽ More

    Submitted 23 September, 2014; v1 submitted 28 July, 2014; originally announced July 2014.

    Comments: 6 pages, 6 figures. Fig. 6 changed. Submitted to EPL

    Journal ref: EPL 108:12001,2014

  13. Performance degradation of Geiger-mode APDs at cryogenic temperatures

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, L. Shekhtman, E. Shemyakina, A. Sokolov, A. Breskin, D. Thers

    Abstract: Two-phase Cryogenic Avalanche Detectors (CRADs) with THGEM multipliers, optically read out with Geiger-mode APDs (GAPDs), were proposed as potential technique for charge recording in rare-event experiments. In this work we report on the degradation of the GAPD performance at cryogenic temperatures revealed in the course of the study of two-phase CRAD in Ar, with combined THGEM/GAPD-matrix multipli… ▽ More

    Submitted 18 June, 2014; originally announced June 2014.

    Comments: 11 pages, 9 figures. Submitted to JINST

    Journal ref: JINST 9:P08006,2014

  14. arXiv:1303.4817  [pdf

    physics.ins-det hep-ex

    First demonstration of THGEM/GAPD-matrix optical readout in two-phase Cryogenic Avalanche Detector in Ar

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, A. Grebenuk, E. Shemyakina, A. Sokolov, A. Breskin, D. Thers

    Abstract: The multi-channel optical readout of a THGEM multiplier coupled to a matrix of 3x3 Geiger-mode APDs (GAPDs) was demonstrated in a two-phase Cryogenic Avalanche Detector (CRAD) in Ar. The GAPDs recorded THGEM-hole avalanches in the Near Infrared (NIR). At an avalanche charge gain of 160, the yield of the combined THGEM/GAPD-matrix multiplier amounted at ~80 photoelectrons per 20 keV X-ray absorbed… ▽ More

    Submitted 19 March, 2013; originally announced March 2013.

    Comments: 4 pages, 6 figures. Presented at Vienna Conference of Instrumentation (Feb 15-20, 2013, Vienna, Austria). Submitted to the Proceedings

    Journal ref: Nucl.Instrum.Meth.A732:213-216,2013

  15. arXiv:1210.0649  [pdf

    physics.ins-det hep-ex

    Two-phase Cryogenic Avalanche Detectors with THGEM and hybrid THGEM/GEM multipliers operated in Ar and Ar+N2

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, A. Grebenuk, E. Shemyakina, A. Sokolov, D. Akimov, A. Breskin, D. Thers

    Abstract: Two-phase Cryogenic Avalanche Detectors (CRADs) with GEM and THGEM multipliers have become an emerging potential technique for charge recording in rare-event experiments. In this work we present the performance of two-phase CRADs operated in Ar and Ar+N2. Detectors with sensitive area of 10x10 cm2, reaching a litre-scale active volume, yielded gains of the order of 1000 with a double-THGEM multipl… ▽ More

    Submitted 2 October, 2012; originally announced October 2012.

    Comments: 22 pages, 13 figures. Submitted to JINST

    Journal ref: JINST 8:P02008,2013

  16. arXiv:1204.0580  [pdf

    physics.ins-det hep-ex nucl-ex

    Study of infrared scintillations in gaseous and liquid argon - Part II: light yield and possible applications

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, A. Grebenuk, S. Peleganchuk, V. Porosev, L. Shekhtman, E. Shemyakina, A. Sokolov

    Abstract: We present here a comprehensive study of the light yield of primary and secondary scintillations produced in gaseous and liquid Ar in the near infrared (NIR) and visible region, at cryogenic temperatures. The measurements were performed using Geiger-mode avalanche photodiodes (GAPDs) and pulsed X-ray irradiation. The primary scintillation yield of the fast emission component in gaseous Ar was foun… ▽ More

    Submitted 28 May, 2012; v1 submitted 2 April, 2012; originally announced April 2012.

    Comments: 20 pages, 11 figures. Submitted to JINST

    Journal ref: JINST 7:P06014,2012

  17. arXiv:1204.0180  [pdf

    physics.ins-det hep-ex

    Study of infrared scintillations in gaseous and liquid argon - Part I: methodology and time measurements

    Authors: A. Bondar, A. Buzulutskov, A. Dolgov, A. Grebenuk, E. Shemyakina, A. Sokolov

    Abstract: A methodology to measure Near Infrared (NIR) scintillations in gaseous and liquid Ar, using Geiger-mode APDs (GAPDs) sensitive in the NIR and pulsed X-ray irradiation, is described. This study has been triggered by the development of Cryogenic Avalanche Detectors (CRADs) with optical readout in the NIR using combined THGEM/GAPD multiplier, which may come to be in demand in coherent neutrino-nucleu… ▽ More

    Submitted 1 April, 2012; originally announced April 2012.

    Comments: 17 pages, 15 figures. Submitted to JINST

    Journal ref: JINST 7:P06015,2012

  18. arXiv:1103.6126  [pdf

    physics.ins-det nucl-ex

    On the low-temperature performances of THGEM and THGEM/G-APD multipliers in gaseous and two-phase Xe

    Authors: A. Bondar, A. Buzulutskov, A. Grebenuk, E. Shemyakina, A. Sokolov, D. Akimov, I. Alexandrov, A. Breskin

    Abstract: The performances of THGEM multipliers in two-phase Xe avalanche mode are presented for the first time. Additional results on THGEM operation in gaseous Xe at cryogenic temperatures are provided. Stable operation of a double-THGEM multiplier was demonstrated in two-phase Xe with gains reaching 600. These are compared to existing data, summarized here for two-phase Ar, Kr and Xe avalanche detectors… ▽ More

    Submitted 21 July, 2011; v1 submitted 31 March, 2011; originally announced March 2011.

    Comments: 22 pages, 14 figures. Revised Figs. 10,11 and Table 1. To be published in JINST

    Journal ref: JINST 6:P07008,2011