-
The Larmor frequency shift of a white matter magnetic microstructure model with multiple sources
Authors:
Anders Dyhr Sandgaard,
Noam Shemesh,
Leif Østergaard,
Valerij G. Kiselev,
Sune Nørhøj Jespersen
Abstract:
Magnetic susceptibility imaging may provide valuable information about chemical composition and microstructural organization of tissue. However, its estimation from the MRI signal phase is particularly difficult as it is sensitive to magnetic tissue properties ranging from the molecular to macroscopic scale. The MRI Larmor frequency shift measured in white matter (WM) tissue depends on the myelina…
▽ More
Magnetic susceptibility imaging may provide valuable information about chemical composition and microstructural organization of tissue. However, its estimation from the MRI signal phase is particularly difficult as it is sensitive to magnetic tissue properties ranging from the molecular to macroscopic scale. The MRI Larmor frequency shift measured in white matter (WM) tissue depends on the myelinated axons and other magnetizable sources such as iron-filled ferritin. We have previously derived the Larmor frequency shift arising from a dense media of cylinders with scalar susceptibility and arbitrary orientation dispersion. Here we extend our model to include microscopic WM susceptibility anisotropy as well as spherical inclusions with scalar susceptibility to represent subcellular structures, biologically stored iron etc. We validate our analytical results with computer simulations and investigate the feasibility of estimating susceptibility using simple iterative linear least squares without regularization or preconditioning. This is done in a digital brain phantom synthesized from diffusion MRI (dMRI) measurements of an ex vivo mouse brain at ultra-high field.
△ Less
Submitted 5 March, 2024; v1 submitted 31 October, 2023;
originally announced November 2023.
-
MP-PCA denoising of fMRI time-series data can lead to artificial activation "spreading"
Authors:
Francisca F. Fernandes,
Jonas L. Olesen,
Sune N. Jespersen,
Noam Shemesh
Abstract:
MP-PCA denoising has become the method of choice for denoising in MRI since it provides an objective threshold to separate the desired signal from unwanted thermal noise components. In rodents, thermal noise in the coils is an important source of noise that can reduce the accuracy of activation map** in fMRI. Further confounding this problem, vendor data often contains zero-filling and other eff…
▽ More
MP-PCA denoising has become the method of choice for denoising in MRI since it provides an objective threshold to separate the desired signal from unwanted thermal noise components. In rodents, thermal noise in the coils is an important source of noise that can reduce the accuracy of activation map** in fMRI. Further confounding this problem, vendor data often contains zero-filling and other effects that may violate MP-PCA assumptions. Here, we develop an approach to denoise vendor data and assess activation "spreading" caused by MP-PCA denoising in rodent task-based fMRI data. Data was obtained from N = 3 mice using conventional multislice and ultrafast acquisitions (1 s and 50 ms temporal resolution, respectively), during visual stimulation. MP-PCA denoising produced SNR gains of 64% and 39% and Fourier spectral amplitude (FSA) increases in BOLD maps of 9% and 7% for multislice and ultrafast data, respectively, when using a small [2 2] denoising window. Larger windows provided higher SNR and FSA gains with increased spatial extent of activation that may or may not represent real activation. Simulations showed that MP-PCA denoising causes activation "spreading" with an increase in false positive rate and smoother functional maps due to local "bleeding" of principal components, and that the optimal denoising window for improved specificity of functional map**, based on Dice score calculations, depends on the data's tSNR and functional CNR. This "spreading" effect applies also to another recently proposed low-rank denoising method (NORDIC). Our results bode well for dramatically enhancing spatial and/or temporal resolution in future fMRI work, while taking into account the sensitivity/specificity trade-offs of low-rank denoising methods.
△ Less
Submitted 28 November, 2022;
originally announced November 2022.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 2 -- Ex vivo imaging
Authors:
Kurt G Schilling,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Lucio Frydman,
Yohan van de Looij,
David Hike,
Jeff F Dunn
, et al. (31 additional authors not shown)
Abstract:
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contras…
▽ More
The value of preclinical diffusion MRI (dMRI) is substantial. While dMRI enables in vivo non-invasive characterization of tissue, ex vivo dMRI is increasingly being used to probe tissue microstructure and brain connectivity. Ex vivo dMRI has several experimental advantages including higher signal-to-noise ratio and spatial resolution compared to in vivo studies, and more advanced diffusion contrasts for improved microstructure and connectivity characterization. Another major advantage is direct comparison with histological data as a crucial methodological validation. However, there are a number of considerations that must be made when performing ex vivo experiments. The steps from tissue preparation, image acquisition and processing, and interpretation of results are complex, with many decisions that not only differ dramatically from in vivo imaging, but ultimately affect what questions can be answered using the data. This work represents 'Part 2' of a series of recommendations and considerations for preclinical dMRI, where we focus on best practices for dMRI of ex vivo tissue. We first describe the value that ex vivo imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We then give guidelines for ex vivo protocols, including tissue preparation, imaging sequences and data processing including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available ex vivo dMRI datasets and dedicated software packages. In each section, we attempt to provide guidelines and recommendations, but also highlight areas for which no guidelines exist, and where future work should lie. An overarching goal herein is to enhance the rigor and reproducibility of ex vivo dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 7 February, 2023; v1 submitted 27 September, 2022;
originally announced September 2022.
-
Recommendations and guidelines from the ISMRM Diffusion Study Group for preclinical diffusion MRI: Part 1 -- In vivo small-animal imaging
Authors:
Ileana O Jelescu,
Francesco Grussu,
Andrada Ianus,
Brian Hansen,
Rachel L C Barrett,
Manisha Aggarwal,
Stijn Michielse,
Fatima Nasrallah,
Warda Syeda,
Nian Wang,
Jelle Veraart,
Alard Roebroeck,
Andrew F Bagdasarian,
Cornelius Eichner,
Farshid Sepehrband,
Jan Zimmermann,
Lucas Soustelle,
Christien Bowman,
Benjamin C Tendler,
Andreea Hertanu,
Ben Jeurissen,
Marleen Verhoye,
Lucio Frydman,
Yohan van de Looij,
David Hike
, et al. (32 additional authors not shown)
Abstract:
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, anal…
▽ More
The value of in vivo preclinical diffusion MRI (dMRI) is substantial. Small-animal dMRI has been used for methodological development and validation, characterizing the biological basis of diffusion phenomena, and comparative anatomy. Many of the influential works in this field were first performed in small animals or ex vivo samples. The steps from animal setup and monitoring, to acquisition, analysis, and interpretation are complex, with many decisions that may ultimately affect what questions can be answered using the data. This work aims to serve as a reference, presenting selected recommendations and guidelines from the diffusion community, on best practices for preclinical dMRI of in vivo animals. In each section, we also highlight areas for which no guidelines exist (and why), and where future work should focus. We first describe the value that small animal imaging adds to the field of dMRI, followed by general considerations and foundational knowledge that must be considered when designing experiments. We briefly describe differences in animal species and disease models and discuss how they are appropriate for different studies. We then give guidelines for in vivo acquisition protocols, including decisions on hardware, animal preparation, imaging sequences and data processing, including pre-processing, model-fitting, and tractography. Finally, we provide an online resource which lists publicly available preclinical dMRI datasets and software packages, to promote responsible and reproducible research. An overarching goal herein is to enhance the rigor and reproducibility of small animal dMRI acquisitions and analyses, and thereby advance biomedical knowledge.
△ Less
Submitted 21 April, 2023; v1 submitted 26 September, 2022;
originally announced September 2022.
-
Incorporating the effect of white matter microstructure in the estimation of magnetic susceptibility in ex-vivo mouse brain
Authors:
Anders Dyhr Sandgaard,
Valerij G. Kiselev,
Rafael Neto Henriques,
Noam Shemesh,
Sune Nørhøj Jespersen
Abstract:
Accurate estimation of microscopic magnetic field variations induced in biological tissue can be valuable for map** tissue composition in health and disease. Here, we present an extension to Quantitative susceptibility map** (QSM) to account for local white matter (WM) magnetic microstructure by using our previously presented model for solid cylinders with arbitrary orientations to describe ax…
▽ More
Accurate estimation of microscopic magnetic field variations induced in biological tissue can be valuable for map** tissue composition in health and disease. Here, we present an extension to Quantitative susceptibility map** (QSM) to account for local white matter (WM) magnetic microstructure by using our previously presented model for solid cylinders with arbitrary orientations to describe axons in terms of concentric cylinders. Through computer simulations, we find that our model improves susceptibility estimation compared to QSM, and Susceptibility Tensor Imaging (STI) are substantially biased by the unaccounted-for structural anisotropy due to the mesoscopic frequency contribution, indicating the observed STI tensor might not represent susceptibility anisotropy as expected. Experiments in mouse brains acquired at ultrahigh field shows the mesoscopic contribution due to WM microstructure to be substantial. This in turn changed estimated susceptibility values up to 25% root-mean-squared-difference in WM compared to standard QSM. Our work underscores how microstructural field effects impact susceptibility estimates, and should not be neglected when imaging anisotropic tissue such as brain WM.
△ Less
Submitted 16 May, 2023; v1 submitted 4 August, 2022;
originally announced August 2022.
-
To mask or not to mask? Investigating the impact of accounting for spatial frequency distributions and susceptibility sources on QSM quality
Authors:
Anders Dyhr Sandgaard,
Noam Shemesh,
Sune Nørhøj Jespersen,
Valerij G. Kiselev
Abstract:
Estimating magnetic susceptibility using MRI depends on inverting a forward relationship between the susceptibility and measured Larmor frequency. However, an often-overlooked constraint in susceptibility fitting is that the Larmor frequency is only measured inside the sample, and after background field removal, susceptibility sources should only reside inside the same sample. Here we test the imp…
▽ More
Estimating magnetic susceptibility using MRI depends on inverting a forward relationship between the susceptibility and measured Larmor frequency. However, an often-overlooked constraint in susceptibility fitting is that the Larmor frequency is only measured inside the sample, and after background field removal, susceptibility sources should only reside inside the same sample. Here we test the impact of accounting for such effects in susceptibility fitting and demonstrate that such effects should not be ignored.
△ Less
Submitted 23 December, 2022; v1 submitted 3 August, 2022;
originally announced August 2022.
-
Tensor denoising of high-dimensional MRI data
Authors:
Jonas L. Olesen,
Andrada Ianus,
Leif Østergaard,
Noam Shemesh,
Sune N. Jespersen
Abstract:
The signal to noise ratio (SNR) fundamentally limits the information accessible by magnetic resonance imaging (MRI). This limitation has been addressed by a host of denoising techniques, recently including so-called MPPCA: Principal component analysis (PCA) of the signal followed by automated rank estimation, exploiting the Marchenko-Pastur (MP) distribution of noise singular values. Operating on…
▽ More
The signal to noise ratio (SNR) fundamentally limits the information accessible by magnetic resonance imaging (MRI). This limitation has been addressed by a host of denoising techniques, recently including so-called MPPCA: Principal component analysis (PCA) of the signal followed by automated rank estimation, exploiting the Marchenko-Pastur (MP) distribution of noise singular values. Operating on matrices comprised by data-patches, this popular approach objectively identifies noise components and, ideally, allows noise to be removed without introducing artifacts such as image blurring or non-local averaging. The MPPCA rank estimation, however, relies on a large number of noise singular values relative to the number of signal components to avoid such ill effects. This condition is unlikely to be met when data-patches and therefore matrices are small, for example due to spatially varying noise. Here, we introduce tensor MPPCA (tMPPCA) for the purpose of denoising multidimensional data, for example from multi-contrast acquisitions. Rather than combining dimensions in matrices, tMPPCA utilizes each dimension of the multidimensional data's inherent tensor-structure to better characterize noise, and to recursively estimate signal components. Relative to matrix-based MPPCA, tMPPCA requires no additional assumptions, and comparing the two in a numerical phantom and a multi-TE diffusion MRI dataset, tMPPCA dramatically improves denoising performance. This is particularly true for small data-patches, which we believe will improve denoising in cases of spatially varying noise.
△ Less
Submitted 15 October, 2022; v1 submitted 30 March, 2022;
originally announced March 2022.
-
Larmor frequency shift from magnetized cylinders with arbitrary orientation distribution
Authors:
Anders Dyhr Sandgaard,
Noam Shemesh,
Valerij G. Kiselev,
Sune Nørhøj Jespersen
Abstract:
We present a theoretical framework for the NMR and MRI measured Larmor frequency in media with magnetized microstructure using the mesoscopic Lorentz sphere and the principle of coarse graining. We obtain an analytical expression for infinite cylinders with arbitrary orientation dispersion and show how it depends on the fiber orientation distribution, measurable using diffusion MRI. Through simula…
▽ More
We present a theoretical framework for the NMR and MRI measured Larmor frequency in media with magnetized microstructure using the mesoscopic Lorentz sphere and the principle of coarse graining. We obtain an analytical expression for infinite cylinders with arbitrary orientation dispersion and show how it depends on the fiber orientation distribution, measurable using diffusion MRI. Through simulations, we scrutinize the framework including the effect of the shape and size of the Lorentz cavity and validate our result for cylinders.
△ Less
Submitted 22 October, 2022; v1 submitted 2 March, 2022;
originally announced March 2022.
-
Diffusion time dependence, power-law scaling, and exchange in gray matter
Authors:
Jonas L. Olesen,
Leif Østergaard,
Noam Shemesh,
Sune N. Jespersen
Abstract:
Diffusion MRI (dMRI) provides contrast that reflect diffusing spins' interactions with microstructural features of biological systems, but its specificity remains limited due to the ambiguity of its relation to the underlying microstructure. To improve specificity, biophysical models of white matter (WM) typically express dMRI signals according to the Standard Model (SM) and have more recently in…
▽ More
Diffusion MRI (dMRI) provides contrast that reflect diffusing spins' interactions with microstructural features of biological systems, but its specificity remains limited due to the ambiguity of its relation to the underlying microstructure. To improve specificity, biophysical models of white matter (WM) typically express dMRI signals according to the Standard Model (SM) and have more recently in gray matter (GM) attempted to incorporate cell soma (the SANDI model). The validity of the assumptions underlying these models, however, remains largely undetermined, especially in GM. Observing the models' unique, functional properties, such as the $b^{-1/2}$ power-law associated with 1d diffusion, has emerged as a fruitful strategy for experimental validation. The absence of this signature in GM has been explained by neurite water exchange, non-linear morphology, and/or obscuring soma signal contributions. Here, we present simulations in realistic neurons demonstrating that curvature and branching does not destroy the stick power-law in impermeable neurites, but that their signal is drowned by the soma under typical experimental conditions: Nevertheless, we identify an attainable experimental regime in which the neurite signal dominates. Furthermore, we find that exchange-driven time dependence produces a behavior opposite to that expected from restricted diffusion, thereby providing a functional signature disambiguating the two effects. We present data from dMRI experiments in ex vivo rat brain at ultrahigh field and observe a time dependence consistent with substantial exchange and a GM stick power-law. The first finding suggests significant water exchange while the second suggests a small sub-population of impermeable neurites. To quantify our observations, we harness the Kärger exchange model and incorporate the corresponding signal time dependence in SM and SANDI.
△ Less
Submitted 23 August, 2021;
originally announced August 2021.
-
Evidence for microscopic kurtosis in neural tissue revealed by Correlation Tensor MRI
Authors:
Rafael Neto Henriques,
Sune Nørhøj Jespersen,
Noam Shemesh
Abstract:
Purpose: The impact of microscopic diffusional kurtosis ($μK$) - arising from restricted diffusion and/or structural disorder - remains a controversial issue in contemporary diffusion MRI (dMRI). Recently, Correlation Tensor MRI (CTI) was introduced to disentangle the sources contributing to diffusional kurtosis, without relying on a-priori assumptions. Here, we aimed to investigate $μK$ in in viv…
▽ More
Purpose: The impact of microscopic diffusional kurtosis ($μK$) - arising from restricted diffusion and/or structural disorder - remains a controversial issue in contemporary diffusion MRI (dMRI). Recently, Correlation Tensor MRI (CTI) was introduced to disentangle the sources contributing to diffusional kurtosis, without relying on a-priori assumptions. Here, we aimed to investigate $μK$ in in vivo rat brains and assess its impact on state-of-the-art methods ignoring $μK$. Methods: CTI harnesses double diffusion encoding (DDE) experiments, which were here improved for speed and minimal bias using four different sets of acquisition parameters. The robustness of CTI estimates from the improved protocol is assessed in simulations. The in vivo CTI acquisitions were performed in healthy rat brains using a 9.4T pre-clinical scanner equipped with a cryogenic coil, and targeted the estimation of $μK$, anisotropic kurtosis, and isotropic kurtosis. Results: The improved CTI acquisition scheme substantially reduces scan time and importantly, also minimizes higher-order-term biases, thus enabling robust $μK$ estimation, alongside Kaniso and Kiso metrics. Our CTI experiments revealed positive $μK$ both in white and grey matter of the rat brain in vivo; $μK$ is the dominant kurtosis source in healthy grey matter tissue. The non-negligible $μK$ substantially biases prior state-of-the-art analyses of Kiso and Kaniso. Conclusion: Correlation Tensor MRI offers a more accurate and robust characterization of kurtosis sources than its predecessors. $μK$ is non-negligible in vivo in healthy white and grey matter tissues and could be an important biomarker for future studies. Our findings thus have both theoretical and practical implications for future experiments.
△ Less
Submitted 17 July, 2021; v1 submitted 23 February, 2021;
originally announced February 2021.
-
Double diffusion encoding and applications for biomedical imaging
Authors:
Rafael N. Henriques,
Marco Palombo,
Sune N. Jespersen,
Noam Shemesh,
Henrik Lundell,
Andrada Ianuş
Abstract:
Diffusion Magnetic Resonance Imaging (dMRI) is one of the most important contemporary non-invasive modalities for probing tissue structure at the microscopic scale. The majority of dMRI techniques employ standard single diffusion encoding (SDE) measurements, covering different sequence parameter ranges depending on the complexity of the method. Although many signal representations and biophysical…
▽ More
Diffusion Magnetic Resonance Imaging (dMRI) is one of the most important contemporary non-invasive modalities for probing tissue structure at the microscopic scale. The majority of dMRI techniques employ standard single diffusion encoding (SDE) measurements, covering different sequence parameter ranges depending on the complexity of the method. Although many signal representations and biophysical models have been proposed for SDE data, they are intrinsically limited by a lack of specificity. Advanced dMRI methods have been proposed to provide additional microstructural information beyond what can be inferred from SDE. These enhanced contrasts can play important roles in characterizing biological tissues, for instance upon diseases (e.g. neurodegenerative, cancer, stroke), aging, learning, and development.
In this review we focus on double diffusion encoding (DDE), which stands out among other advanced acquisitions for its versatility, ability to probe more specific diffusion correlations, and feasibility for preclinical and clinical applications. Various DDE methodologies have been employed to probe compartment sizes (Section 3), decouple the effects of microscopic diffusion anisotropy from orientation dispersion (Section 4), probe displacement correlations, study exchange, or suppress fast diffusing compartments (Section 6). DDE measurements can also be used to improve the robustness of biophysical models (Section 5) and study intra-cellular diffusion via magnetic resonance spectroscopy of metabolites (Section 7). This review discusses all these topics as well as important practical aspects related to the implementation and contrast in preclinical and clinical settings (Section 9) and aims to provide the readers a guide for deciding on the right DDE acquisition for their specific application.
△ Less
Submitted 5 November, 2020;
originally announced November 2020.
-
Effective bowel motion reduction in mouse abdominal MRI using hyoscine butylbromide
Authors:
Carlos Bilreiro,
Francisca F. Fernandes,
Luísa Andrade,
Cristina Chavarrías,
Rui V. Simões,
Celso Matos,
Noam Shemesh
Abstract:
Purpose: Bowel motion is a significant source of artifacts in mouse abdominal MRI. Fasting and administration of hyoscine butylbromide (BUSC) have been proposed for bowel motion reduction, but with inconsistent results and limited efficacy assessments. Here, we evaluate these regimes for mouse abdominal MRI at high field. Methods: Thirty-two adult C57BL/6J mice were imaged on a 9.4T scanner with a…
▽ More
Purpose: Bowel motion is a significant source of artifacts in mouse abdominal MRI. Fasting and administration of hyoscine butylbromide (BUSC) have been proposed for bowel motion reduction, but with inconsistent results and limited efficacy assessments. Here, we evaluate these regimes for mouse abdominal MRI at high field. Methods: Thirty-two adult C57BL/6J mice were imaged on a 9.4T scanner with a FLASH sequence, acquired over 90 minutes with ~19s temporal resolution. During MRI acquisition, eight mice were injected with a low-dose and eight mice with a high-dose bolus of BUSC (0.5 and 5 mg/kg, respectively). Eight mice were food deprived for 4.5-6.5h before MRI and another group of 8 mice was injected with saline during MRI acquisition. Two expert readers reviewed the images and classified bowel motion, and quantitative voxel-wise analyses were performed for identification of moving regions. After defining the most effective protocol, high-resolution T2-weighted and diffusion-weighted images were acquired from four mice. Results: High-dose BUSC was the most effective protocol for bowel motion reduction, for up to 45 minutes. Fasting and saline protocols were not effective in suppressing bowel motion. High-resolution abdominal MRI clearly demonstrated improved image quality and ADC quantification with the high-dose BUSC protocol. Conclusion: Our data show that BUSC administration is advantageous for abdominal MRI in the mouse. Specifically, it endows significant bowel motion reduction, with relatively short onset timings after injection (~8.5 minutes) and relatively long duration of the effect (~45 minutes). These features improve the quality of high-resolution images of the mouse abdomen.
△ Less
Submitted 14 May, 2021; v1 submitted 8 July, 2020;
originally announced July 2020.
-
Ultrafast functional magnetic resonance imaging reveals neuroplasticity-driven timing modulations
Authors:
Rita Gil,
Francisca F. Fernandes,
Noam Shemesh
Abstract:
Functional Magnetic Resonance Imaging (fMRI) is predominantly harnessed for spatially map** activation foci along distributed pathways. However, resolving dynamic information on activation sequence remains elusive. Here, we show an ultra-fast fMRI (ufMRI) approach - a facilitating non-invasive methodology for map** Blood-Oxygenation-Level-Dependent (BOLD) response timings in distributed pathwa…
▽ More
Functional Magnetic Resonance Imaging (fMRI) is predominantly harnessed for spatially map** activation foci along distributed pathways. However, resolving dynamic information on activation sequence remains elusive. Here, we show an ultra-fast fMRI (ufMRI) approach - a facilitating non-invasive methodology for map** Blood-Oxygenation-Level-Dependent (BOLD) response timings in distributed pathways with high spatiotemporal sensitivity and resolution. The mouse visual pathway was investigated under both normal and dark reared conditions. Results show that BOLD responses of normal reared mice preserve the neural input order from onset to peak times. However, modulatory effects in cortical responses due to dark rearing are only measurable at early response timings while a general delay in responses is measured at later timings. Our findings highlight the importance of robustly measuring early BOLD timings and pave the way for a better understanding and interpretation of functional MRI in healthy and aberrant conditions.
△ Less
Submitted 31 January, 2020;
originally announced February 2020.
-
In-vivo Magnetic Resonance Imaging of GABA and Glutamate
Authors:
Frederico Severo,
Noam Shemesh
Abstract:
Chemical Exchange Saturation Transfer (CEST) Magnetic Resonance Imaging (MRI) is a molecular imaging methodology capable of map** brain metabolites with relatively high spatial resolution. Specificity is the main goal of such experiments; yet CEST is confounded by spectral overlap between different molecular species. Here, we overcome this major limitation using a general framework termed overla…
▽ More
Chemical Exchange Saturation Transfer (CEST) Magnetic Resonance Imaging (MRI) is a molecular imaging methodology capable of map** brain metabolites with relatively high spatial resolution. Specificity is the main goal of such experiments; yet CEST is confounded by spectral overlap between different molecular species. Here, we overcome this major limitation using a general framework termed overlap-resolved CEST (orCEST) - a kind of spectrally-edited experiment restoring specificity. First, we present evidence revealing that CEST experiments targeting the central nervous system's primary excitatory neurotransmitter, Glutamate (GluCEST) - is significantly contaminated by gamma-aminobutyric acid (GABA) - the primary inhibitory neurotransmitter in the CNS. Then, we harness the novel orCEST methodology to separate Glutamate and - for the first time - GABA signals, thus delivering the desired specificity. In-vivo orCEST experiments resolved the rat brain's primary neurotransmitters and revealed changes in Glutamate and GABA levels upon water deprivation in thirst-related areas. orCEST's features bode well for many applications in neuroscience and biomedicine.
△ Less
Submitted 23 January, 2020;
originally announced January 2020.
-
A rapid-onset diffusion functional MRI signal reflects neuromorphological coupling dynamics
Authors:
Daniel Nunes,
Rita Gil,
Noam Shemesh
Abstract:
Functional Magnetic Resonance Imaging (fMRI) has transformed our understanding of brain function in-vivo. However, the neurovascular coupling mechanisms underlying fMRI are somewhat "distant" from neural activity. Interestingly, evidence from Intrinsic Optical Signals (IOSs) indicates that neural activity is also coupled to (sub)cellular morphological modulations. Diffusion-weighted functional MRI…
▽ More
Functional Magnetic Resonance Imaging (fMRI) has transformed our understanding of brain function in-vivo. However, the neurovascular coupling mechanisms underlying fMRI are somewhat "distant" from neural activity. Interestingly, evidence from Intrinsic Optical Signals (IOSs) indicates that neural activity is also coupled to (sub)cellular morphological modulations. Diffusion-weighted functional MRI (dfMRI) experiments have been previously proposed to probe such neuromorphological couplings, but the underlying mechanisms have remained highly contested. Here, we provide the first direct link between in vivo ultrafast dfMRI signals upon rat forepaw stimulation and IOSs in acute slices stimulated optogenetically. We reveal a hitherto unreported rapid onset (<100 ms) dfMRI signal which (i) agrees with fast-rising IOSs dynamics; (ii) evidences a punctate quantitative correspondence to the stimulation period; (iii) and is rather insensitive to a vascular challenge. Our findings suggest that neuromorphological coupling can be detected via dfMRI signals, auguring well for future map** of neural activity more directly.
△ Less
Submitted 23 January, 2020;
originally announced January 2020.
-
Functional Magnetic Resonance Spectroscopy in the mouse
Authors:
Clémence Ligneul,
Francisca F. Fernandes,
Noam Shemesh
Abstract:
Functional magnetic resonance spectroscopy (fMRS) quantifies metabolic variations upon presentation of a stimulus and can therefore provide complementary information compared to functional magnetic resonance imaging (fMRI). However, to our knowledge, fMRS has not yet been performed in the mouse, despite that murine models are crucial for basic and applied research. Here, we performed fMRS experime…
▽ More
Functional magnetic resonance spectroscopy (fMRS) quantifies metabolic variations upon presentation of a stimulus and can therefore provide complementary information compared to functional magnetic resonance imaging (fMRI). However, to our knowledge, fMRS has not yet been performed in the mouse, despite that murine models are crucial for basic and applied research. Here, we performed fMRS experiments in the mouse, for the first time, and show the feasibility of such an approach for reliably quantifying metabolic variations. In particular, we observed metabolic variations in the superior colliculus of mice upon visual stimulation in a block paradigm commonly used for fMRI (short periods of stimulus), followed by a recovery period. We notably report a robust modulation of glutamate, as well as a modulation of NAAG, PCr and Cr. A control experiment with no stimulation reveals potential metabolic signal "drifts" that are not correlated with the functional activity, which should be taken into account when analyzing fMRS data in general. Our findings are promising for future applications of fMRS in the mouse.
△ Less
Submitted 23 January, 2020;
originally announced January 2020.
-
Validation and noise robustness assessment of microscopic anisotropy estimation with clinically feasible double diffusion encoding MRI
Authors:
Leevi Kerkelä,
Rafael Neto Henriques,
Matt G. Hall,
Chris A. Clark,
Noam Shemesh
Abstract:
Purpose: Double diffusion encoding (DDE) MRI enables the estimation of microscopic diffusion anisotropy, yielding valuable information on tissue microstructure. A recent study proposed that the acquisition of rotationally invariant DDE metrics, typically obtained using a spherical "5-design", could be greatly simplified by assuming Gaussian diffusion, facilitating reduced acquisition times that ar…
▽ More
Purpose: Double diffusion encoding (DDE) MRI enables the estimation of microscopic diffusion anisotropy, yielding valuable information on tissue microstructure. A recent study proposed that the acquisition of rotationally invariant DDE metrics, typically obtained using a spherical "5-design", could be greatly simplified by assuming Gaussian diffusion, facilitating reduced acquisition times that are more compatible with clinical settings. Here, we aim to validate the new minimal acquisition scheme against the standard DDE 5-design, and to quantify the proposed method's noise robustness to facilitate future clinical use. Methods: DDE MRI experiments were performed on both ex vivo and in vivo rat brains at 9.4 T using the 5-design and the proposed minimal design and taking into account the difference in the number of acquisitions. The ensuing microscopic fractional anisotropy (μFA) maps were compared over a range of b-values up to 5000 s/mm2. Noise robustness was studied using analytical calculations and numerical simulations. Results: The minimal protocol quantified μFA at an accuracy comparable to the estimates obtained via the more theoretically robust DDE 5-design. μFA's sensitivity to noise was found to strongly depend on compartment anisotropy and tensor magnitude in a non-linear fashion. When μFA < 0.75 or when mean diffusivity is particularly low, very high signal to noise ratio (SNR) is required for precise quantification of μFA. Conclusion: Our work supports using DDE for quantifying microscopic diffusion anisotropy in clinical settings but raises hitherto overlooked precision issues when measuring μFA with DDE and typical clinical SNR.
△ Less
Submitted 4 November, 2019;
originally announced November 2019.
-
Correlation Tensor Magnetic Resonance Imaging
Authors:
Rafael Neto Henriques,
Sune Nørhøj Jespersen,
Noam Shemesh
Abstract:
Diffusional Kurtosis Imaging (DKI) is a sensitive biomarker for microstructure in health and disease. However, DKI is not specific to any microstructural property since it may emerge from several different sources. Q-space trajectory encoding has been proposed for decoupling isotropic from anisotropic kurtosis. Still, this method assume that the system is comprised of multiple Gaussian diffusion c…
▽ More
Diffusional Kurtosis Imaging (DKI) is a sensitive biomarker for microstructure in health and disease. However, DKI is not specific to any microstructural property since it may emerge from several different sources. Q-space trajectory encoding has been proposed for decoupling isotropic from anisotropic kurtosis. Still, this method assume that the system is comprised of multiple Gaussian diffusion components. Here, we develop a more general framework for resolving the underlying kurtosis sources. We introduce Correlation Tensor MRI (CTI) - an approach harnessing the versatility of double diffusion encoding (DDE) and capable of explicitly decoupling isotropic and anisotropic kurtosis components from intra-compartmental kurtosis effects arising from restricted diffusion. Additionally, CTI provides an index that is potentially sensitive to intra-compartmental kurtosis. The theoretical foundations of CTI, as well as the first proof-of-concept CTI ex vivo experiments in mouse brains at a field of 16.4T, are presented. We find that anisotropic and isotropic kurtosis can decouple microscopic anisotropy from substantial partial volume effects between tissue and free water. Our intra-compartmental kurtosis index exhibited positive values in both white and grey matter tissues. Simulations in different microenvironments show, however, that our current CTI protocol for estimating intra-compartmental kurtosis is limited by higher-order terms that were not considered in this study. CTI measurements were then extended to in vivo settings and used to map healthy rat brains at 9.4T. These in vivo CTI results were consistent with our ex vivo findings. Although future studies are still required to mitigate the higher-order effects on the intra-compartmental kurtosis index, results show that CTI's more general estimates of anisotropic and isotropic kurtosis contributions are already ripe for future studies.
△ Less
Submitted 5 March, 2020; v1 submitted 31 July, 2019;
originally announced August 2019.
-
SANDI: a compartment-based model for non-invasive apparent soma and neurite imaging by diffusion MRI
Authors:
Marco Palombo,
Andrada Ianus,
Daniel Nunes,
Michele Guerreri,
Daniel C. Alexander,
Noam Shemesh,
Hui Zhang
Abstract:
This work introduces a compartment-based model for apparent soma and neurite density imaging (SANDI) using non-invasive diffusion-weighted MRI (DW-MRI). The existing conjecture in brain microstructure imaging trough DW-MRI presents water diffusion in white (WM) and grey (GM) matter as restricted diffusion in neurites, modelled by infinite cylinders of null radius embedded in the hindered extra-neu…
▽ More
This work introduces a compartment-based model for apparent soma and neurite density imaging (SANDI) using non-invasive diffusion-weighted MRI (DW-MRI). The existing conjecture in brain microstructure imaging trough DW-MRI presents water diffusion in white (WM) and grey (GM) matter as restricted diffusion in neurites, modelled by infinite cylinders of null radius embedded in the hindered extra-neurite water. The extra-neurite pool in WM corresponds to water in the extra-axonal space, but in GM it combines water in the extra-cellular space with water in soma. While several studies showed that this microstructure model successfully describe DW-MRI data in WM and GM at b<3 ms/{\mum^2}, it has been also shown to fail in GM at high b values (b>>3 ms/{\mum^2}). Here we hypothesize that the unmodelled soma compartment may be responsible for this failure and propose SANDI as a new model of brain microstructure where soma (i.e. cell body of any brain cell type: from neuroglia to neurons) is explicitly included. We assess the effects of size and density of soma on the direction-averaged DW-MRI signal at high b values and the regime of validity of the model using numerical simulations and comparison with experimental data from mouse (bmax = 40 ms/{/mum^2}) and human (bmax = 10 ms/{\mum^2}) brain. We show that SANDI defines new contrasts representing new complementary information on the brain cyto- and myelo-architecture. Indeed, we show for the first-time maps from 25 healthy human subjects of MR soma and neurite signal fractions, that remarkably mirror contrasts of histological images of brain cyto- and myelo-architecture. Although still under validation, SANDI might provide new insight into tissue architecture by introducing a new set of biomarkers of potential great value for biomedical applications and pure neuroscience.
△ Less
Submitted 7 April, 2020; v1 submitted 5 July, 2019;
originally announced July 2019.
-
Short echo time relaxation-enhanced MR spectroscopy reveals broad downfield resonances
Authors:
Sónia I. Gonçalves,
Clémence Ligneul,
Noam Shemesh
Abstract:
Purpose: Most MR spectroscopy (MRS) pulse sequences rely on broadband excitation with water saturation and typically focus on upfield signals. By contrast, the downfield spectrum, which contains many potentially useful resonances, is typically not targeted because conventional water-suppressed techniques indirectly saturate the labile protons through exchange. Relaxation-enhanced MRS (RE-MRS) uses…
▽ More
Purpose: Most MR spectroscopy (MRS) pulse sequences rely on broadband excitation with water saturation and typically focus on upfield signals. By contrast, the downfield spectrum, which contains many potentially useful resonances, is typically not targeted because conventional water-suppressed techniques indirectly saturate the labile protons through exchange. Relaxation-enhanced MRS (RE-MRS) uses frequency-selective excitation while actively avoiding bulk water perturbation, thereby enabling high-quality downfield spectroscopy. However, RE-MRS typically requires very long (typically >40 ms) echo times (TEs) due to its localization module, which inevitably decreases sensitivity and filters shorter T2 components. Here, we overcome this limitation by combining RE-MRS and image selected in vivo spectroscopy (ISIS) localization, abbreviated iRE-MRS, which in turn allows very short TEs (5 ms using our hardware).
Methods: Experiments were performed in vitro for validation as well as and in in vivo rat brains at 9.4T.
Results: The new iRE-MRS methodology was validated in phantoms where good performance was noted. When the downfield spectrum was investigated at short TEs in in vivo rat brains, iRE-MRS provided very high sensitivity; the ensuing downfield spectra encompassed numerous broad peaks, as well as a broad baseline. All downfield spectral peaks were highly attenuated by increasing TEs as well as by applying water saturation, although to different extent. The signal ratios also varied between TEs, suggesting that exchange rates are different among the downfield signals.
Conclusions: Short-TE iRE 1H downfield MRS opens new directions in the investigation of in vivo downfield metabolites and their role on healthy and disease processes.
△ Less
Submitted 22 May, 2019;
originally announced May 2019.
-
Insights into brain microstructure from in vivo DW-MRS
Authors:
Marco Palombo,
Noam Shemesh,
Itamar Ronen,
Julien Valette
Abstract:
Many developmental processes, such as plasticity and aging, or pathological processes such as neurological diseases are characterized by modulations of specific cellular types and their microstructures. Diffusion-weighted Magnetic Resonance Imaging (DW-MRI) is a powerful technique for probing microstructure, yet its information arises from the ubiquitous, non-specific water signal. By contrast, di…
▽ More
Many developmental processes, such as plasticity and aging, or pathological processes such as neurological diseases are characterized by modulations of specific cellular types and their microstructures. Diffusion-weighted Magnetic Resonance Imaging (DW-MRI) is a powerful technique for probing microstructure, yet its information arises from the ubiquitous, non-specific water signal. By contrast, diffusion-weighted Magnetic Resonance Spectroscopy (DW-MRS) allows specific characterizations of tissues such as brain and muscle in vivo by quantifying the diffusion properties of MR-observable metabolites. Many brain metabolites are predominantly intracellular, and some of them are preferentially localized in specific brain cell populations, e.g., neurons and glia. Given the microstructural sensitivity of diffusion-encoding filters, investigation of metabolite diffusion properties using DW-MRS can thus provide exclusive cell and compartment-specific information. Furthermore, since many models and assumptions are used for quantification of water diffusion, metabolite diffusion may serve to generate a-priori information for model selection in DW-MRI. However, DW-MRS measurements are extremely challenging, from the acquisition to the accurate and correct analysis and quantification stages. In this review, we survey the state-of-the-art methods that have been developed for the robust acquisition, quantification and analysis of DW-MRS data and discuss the potential relevance of DW-MRS for elucidating brain microstructure in vivo. The review highlights that when accurate data on the diffusion of multiple metabolites is combined with accurate computational and geometrical modelling, DW-MRS can provide unique cell-specific information on the intracellular structure of brain tissue, in health and disease, which could serve as incentives for further application in vivo in human (...)
△ Less
Submitted 19 March, 2019;
originally announced March 2019.
-
Axon diameters and myelin content modulate microscopic fractional anisotropy at short diffusion times in fixed rat spinal cord
Authors:
Noam Shemesh
Abstract:
Map** tissue microstructure accurately and noninvasively is one of the frontiers of biomedical imaging. Diffusion Magnetic Resonance Imaging (MRI) is at the forefront of such efforts, as it is capable of reporting on microscopic structures orders of magnitude smaller than the voxel size by probing restricted diffusion. Double Diffusion Encoding (DDE) and Double Oscillating Diffusion Encoding (DO…
▽ More
Map** tissue microstructure accurately and noninvasively is one of the frontiers of biomedical imaging. Diffusion Magnetic Resonance Imaging (MRI) is at the forefront of such efforts, as it is capable of reporting on microscopic structures orders of magnitude smaller than the voxel size by probing restricted diffusion. Double Diffusion Encoding (DDE) and Double Oscillating Diffusion Encoding (DODE) in particular, are highly promising for their ability to report on microscopic fractional anisotropy (μFA), a measure of the pore anisotropy in its own eigenframe, irrespective of orientation distribution. However, the underlying correlates of μFA have insofar not been studied. Here, we extract μFA from DDE and DODE measurements at ultrahigh magnetic field of 16.4T in the aim to probe fixed rat spinal cord microstructure. We further endeavor to correlate μFA with Myelin Water Fraction (MWF) derived from multiexponential T2 relaxometry, as well as with literature-based spatially varying axonal diameters. In addition, a simple new method is presented for extracting unbiased μFA from three measurements at different b-values. Our findings reveal strong anticorrelations between μFA (derived from DODE) and axon diameter in the distinct spinal cord tracts; a moderate correlation was also observed between μFA derived from DODE and MWF. These findings suggest that axonal membranes strongly modulate μFA, which - owing to its robustness towards orientation dispersion effects - reflects axon diameter much better than its typical FA counterpart. The μFA exhibited modulations when measured via oscillating or blocked gradients, suggesting selective probing of different parallel path lengths and providing insight into how those modulate μFA metrics. Our findings thus shed light into the underlying microstructural correlates of μFA and are (...)
△ Less
Submitted 19 March, 2019;
originally announced March 2019.
-
Two-dimensional Magnetization-Transfer - CPMG MRI reveals tract- specific signatures in fixed rat spinal cord
Authors:
Teresa Serradas Duarte,
Noam Shemesh
Abstract:
Multiexponential T2 (MET2) Relaxometry and Magnetization Transfer (MT) are among the most promising MRI-derived techniques for white matter (WM) characterization. Both techniques are shown to have histologically correlated sensitivity to myelin, but these correlations are not fully understood. Furthermore, MET2 and MT reports on different features of WM, thus being specific to different (patho)phy…
▽ More
Multiexponential T2 (MET2) Relaxometry and Magnetization Transfer (MT) are among the most promising MRI-derived techniques for white matter (WM) characterization. Both techniques are shown to have histologically correlated sensitivity to myelin, but these correlations are not fully understood. Furthermore, MET2 and MT reports on different features of WM, thus being specific to different (patho)physiological states. Two-dimensional studies, such as those commonly used in NMR, have been rarely performed in this context. Here, off-resonance irradiation effects on MET2 components were evaluated in fixed rat spinal cord white matter at 16.4T. These 2D MT-MET2 experiments reveal that MT affects both short and long T2 in a tract-specific fashion. The spatially distinct modulations enhanced contrast between microstructurally-distinct spinal cord tracts. Two hypotheses to explain these findings were proposed: either selective elimination of a short T2 component through pre-saturation is combined with intercompartmental water exchange effects that occur on the timescale of irradiation; or other macromolecular species that exist within the tissue - other than myelin - such as neurofilaments, may be involved in the apparent microstructural segregation of the spinal cord (SC) from MET2. Though further investigation is required to elucidate the underlying mechanism, this phenomenon adds a new dimension for WM characterization.
△ Less
Submitted 19 March, 2019;
originally announced March 2019.
-
BOLD-fMRI in the mouse auditory pathway
Authors:
Guilherme Blazquez Freches,
Cristina Chavarrias,
Noam Shemesh
Abstract:
The auditory pathway is widely distributed throughout the brain, and is perhaps one of the most interesting networks in the context of neuroplasticity. Accurate map** of neural activity in the entire pathway, preferably noninvasively, and with high resolution, could be instrumental for understanding such longitudinal processes. Functional magnetic resonance imaging (fMRI) has clear advantages fo…
▽ More
The auditory pathway is widely distributed throughout the brain, and is perhaps one of the most interesting networks in the context of neuroplasticity. Accurate map** of neural activity in the entire pathway, preferably noninvasively, and with high resolution, could be instrumental for understanding such longitudinal processes. Functional magnetic resonance imaging (fMRI) has clear advantages for such characterizations, as it is noninvasive, provides relatively high spatial resolution and lends itself for repetitive studies, albeit relying on an indirect neurovascular coupling to deliver its information. Indeed, fMRI has been previously used to characterize the auditory pathway in humans and in rats. In the mouse, however, the auditory pathway has insofar only been mapped using manganese-enhanced MRI. Here, we describe a novel setup specifically designed for high-resolution map** of the mouse auditory pathway using high-field fMRI. Robust and consistent Blood-Oxygenation-Level-Dependent (BOLD) responses were documented along nearly the entire auditory pathway, from the cochlear nucleus (CN), through the superior olivary complex (SOC), nuclei of the lateral lemniscus (LL), inferior colliculus (IC) and the medial geniculate body (MGB). By contrast, clear BOLD responses were not observed in auditory cortex (AC) in this study. Diverse BOLD latencies were mapped ROI- and pixel-wise using coherence analysis, evidencing different averaged BOLD time courses in different auditory centers. Some degree of tonotopy was identified in the IC, SOC, and MGB in the pooled dataset though it could not be assessed per subject due to a lack of statistical power. Given the importance of the mouse model in plasticity studies, animal models, and optogenetics, and fMRI's potential to map dynamic responses to specific cues, this first fMRI study of the mouse auditory pathway paves the way for future (...)
△ Less
Submitted 19 March, 2019;
originally announced March 2019.
-
Incomplete Nutation Diffusion Imaging: an ultrafast, single-scan approach for diffusion map**
Authors:
Andrada Ianuş,
Noam Shemesh
Abstract:
Purpose: Diffusion Magnetic Resonance Imaging (dMRI) is confounded by its long acquisition duration, thereby thwarting the detection of rapid microstructural changes, especially when diffusivity variations are accompanied by rapid changes in T2. The purpose of the present study is to accelerate dMRI to a single scan acquisition, and to enable a more accurate estimation of diffusivity as function o…
▽ More
Purpose: Diffusion Magnetic Resonance Imaging (dMRI) is confounded by its long acquisition duration, thereby thwarting the detection of rapid microstructural changes, especially when diffusivity variations are accompanied by rapid changes in T2. The purpose of the present study is to accelerate dMRI to a single scan acquisition, and to enable a more accurate estimation of diffusivity as function of time. Methods: A general methodology termed Incomplete Initial Nutation Diffusion Imaging (INDI) capturing two diffusion contrasts in a single shot, is presented. INDI creates a longitudinal magnetization reservoir that facilitates the successive acquisition of two images separated by only a few milliseconds. INDI's theory is presented, followed by proof-of-concept ex- and in-vivo experiments at 16.4 T and 9.4 T. Results: Mean diffusivities (MDs) extracted from INDI were comparable with Diffusion Tensor Imaging (DTI) and the two-shot IDE in the water phantom. As expected in the brain tissues, DTI provided lower MD than UF-IDE and IDE, but IDE and UF-IDE were in excellent agreement. Simulations are presented for identifying the regimes where INDI is most beneficial. Conclusions: INDI accelerates dMRI acquisition to single-shot mode, which can be of great importance for map** dynamic microstructural properties in-vivo without T2 bias.
△ Less
Submitted 19 March, 2019;
originally announced March 2019.
-
Microscopic anisotropy misestimation in spherical-mean single diffusion encoding MRI
Authors:
Rafael Neto Henriques,
Sune N Jespersen,
Noam Shemesh
Abstract:
Purpose: Microscopic fractional anisotropy (μFA) can disentangle microstructural information from orientation dispersion. While double diffusion encoding (DDE) MRI methods are widely used to extract accurate μFA, it has only recently been proposed that powder-averaged single diffusion encoding (SDE) signals, when coupled with the diffusion standard model (SM) and a set of constraints, could be use…
▽ More
Purpose: Microscopic fractional anisotropy (μFA) can disentangle microstructural information from orientation dispersion. While double diffusion encoding (DDE) MRI methods are widely used to extract accurate μFA, it has only recently been proposed that powder-averaged single diffusion encoding (SDE) signals, when coupled with the diffusion standard model (SM) and a set of constraints, could be used for μFA estimation. This study aims to evaluate μFA as derived from the spherical mean technique (SMT) set of constraints, as well as more generally for powder-averaged SM signals. Methods: SDE experiments were performed at 16.4 T on an ex vivo mouse brain (Δ/δ = 12/1.5 ms). The μFA maps obtained from powder-averaged SDE signals were then compared to maps obtained from DDE-MRI experiments (Δ/τ/δ = 12/12/1.5 ms), which allow a model-free estimation of μFA. Theory and simulations that consider different types of heterogeneity are presented for corroborating the experimental findings. Results: μFA, as well as other estimates derived from powder-averaged SDE signals produced large deviations from the ground truth in both gray and white matter. Simulations revealed that these misestimations are likely a consequence of factors not considered by the underlying microstructural models (such as intercomponent and intracompartmental kurtosis). Conclusion: Powder-averaged SMT and (2-component) SM are unable to accurately report μFA and other microstructural parameters in ex vivo tissues. Improper model assumptions and constraints can significantly compromise parameter specificity. Further developments and validations are required prior to implementation of these models in clinical or preclinical research.
△ Less
Submitted 20 March, 2019;
originally announced March 2019.
-
Evaluation of principal component analysis image denoising on multi-exponential MRI relaxometry
Authors:
Mark D. Does,
Jonas Lynge Olesen,
Kevin D. Harkins,
Teresa Serradas Duarte,
Daniel F. Gochberg,
Sune N. Jespersen,
Noam Shemesh
Abstract:
PURPOSE: Multi-exponential relaxometry is a powerful tool for characterizing tissue, but generally requires high image signal-to-noise ratio (SNR). This work evaluates the use of principal-component-analysis (PCA) denoising to mitigate these SNR demands and improve the precision of relaxometry measures. METHODS: PCA denoising was evaluated using both simulated and experimental MRI data. Bi-exponen…
▽ More
PURPOSE: Multi-exponential relaxometry is a powerful tool for characterizing tissue, but generally requires high image signal-to-noise ratio (SNR). This work evaluates the use of principal-component-analysis (PCA) denoising to mitigate these SNR demands and improve the precision of relaxometry measures. METHODS: PCA denoising was evaluated using both simulated and experimental MRI data. Bi-exponential transverse relaxation signals were simulated for a wide range of acquisition and sample parameters, and experimental data were acquired from three excised and fixed mouse brains. In both cases, standard relaxometry analysis was performed on both original and denoised image data, and resulting estimated signal parameters were compared. RESULTS: Denoising reduced the root-mean-square-error of parameters estimated from multi-exponential relaxometry by factors of 2 to 4x, for typical acquisition and sample parameters. Denoised images and subsequent parameter maps showed little or no signs of spatial artifact or loss of resolution. CONCLUSION: Experimental studies and simulations demonstrate that PCA denoising of MRI relaxometry data is an effective method of improving parameter precision without sacrificing image resolution. This simple yet important processing step thus paves the way for broader applicability of multi-exponential MRI relaxometry.
△ Less
Submitted 21 March, 2019; v1 submitted 19 March, 2019;
originally announced March 2019.
-
Layer-specific connectivity revealed by diffusion-weighted functional MRI in the rat thalamocortical pathway
Authors:
Daniel Nunes,
Andrada Ianus,
Noam Shemesh
Abstract:
Investigating neural activity from a global brain perspective in-vivo has been in the domain of functional Magnetic Resonance Imaging (fMRI) over the past few decades. The intricate neurovascular couplings that govern fMRI's blood-oxygenation-level-dependent (BOLD) functional contrast are invaluable in map** active brain regions, but they also entail significant limitations, such as non-specific…
▽ More
Investigating neural activity from a global brain perspective in-vivo has been in the domain of functional Magnetic Resonance Imaging (fMRI) over the past few decades. The intricate neurovascular couplings that govern fMRI's blood-oxygenation-level-dependent (BOLD) functional contrast are invaluable in map** active brain regions, but they also entail significant limitations, such as non-specificity of the signal to active foci. Diffusion-weighted functional MRI (dfMRI) with relatively high diffusion-weighting strives to ameliorate this shortcoming as it offers functional contrasts more intimately linked with the underlying activity. Insofar, apart from somewhat smaller activation foci, dfMRI's contrasts have not been convincingly shown to offer significant advantages over BOLD, and its contrasts relied on significant modelling. Here, we study whether dfMRI could offer a better representation of neural activity in the thalamocortical pathway compared to its (spin-echo (SE)) BOLD counterpart. Using high-end forepaw stimulation experiments in the rat at 9.4 T, and with significant sensitivity enhancements due to the use of cryocoils, we show for the first time that dfMRI signals exhibit layer specificity, and, additionally, display signals in areas devoid of SE-BOLD responses. We find that dfMRI signals in the thalamocortical pathway cohere with each other, namely, dfMRI signals in the ventral posterolateral (VPL) thalamic nucleus cohere specifically with layers IV and V in the somatosensory cortex. These activity patterns are much better correlated (compared with SE-BOLD signals) with literature-based electrophysiological recordings in the cortex as well as thalamus. All these findings suggest that dfMRI signals better represent the underlying neural activity in the pathway. In turn, this may entail significant implications towards a much more specific and accurate (...)
△ Less
Submitted 19 March, 2019;
originally announced March 2019.
-
Diffusion Kurtosis Imaging maps neural damage in the EAE model of multiple sclerosis
Authors:
Andrey Chuhutin,
Brian Hansen,
Agnieszka Wlodarczyk,
Trevor Owens,
Noam Shemesh,
Sune Nørhøj Jespersen
Abstract:
Diffusion kurtosis imaging (DKI), is an imaging modality that yields novel disease biomarkers and in combination with nervous tissue modeling, provides access to microstructural parameters. Recently, DKI and subsequent estimation of microstructural model parameters has been used for assessment of tissue changes in neurodegenerative diseases and their animal models. In this study, mouse spinal cord…
▽ More
Diffusion kurtosis imaging (DKI), is an imaging modality that yields novel disease biomarkers and in combination with nervous tissue modeling, provides access to microstructural parameters. Recently, DKI and subsequent estimation of microstructural model parameters has been used for assessment of tissue changes in neurodegenerative diseases and their animal models. In this study, mouse spinal cords from the experimental autoimmune encephalomyelitis (EAE) model of multiple sclerosis (MS) were investigated for the first time using DKI in combination with biophysical modeling to study the relationship between microstructural metrics and degree of animal dysfunction. Thirteen spinal cords were extracted from animals of variable disability and scanned in a high-field MRI scanner along with five control specimen. Diffusion weighted data were acquired together with high resolution T2* images. Diffusion data were fit to estimate diffusion and kurtosis tensors and white matter modeling parameters, which were all used for subsequent statistical analysis using a linear mixed effects model. T2* images were used to delineate focal demyelination/inflammation. Our results unveil a strong relationship between disability and measured microstructural parameters in normal appearing white matter and gray matter. The changes we found in biophysical modeling parameters and in particular in extra-axonal axial diffusivity were clearly different from previous studies employing other animal models of MS. In conclusion, our data suggest that DKI and microstructural modeling can provide a unique contrast capable of detecting EAE-specific changes correlating with clinical disability. These findings could close the gap between MRI findings and clinical presentation in patients and deepen our understanding of EAE and the MS mechanisms.
△ Less
Submitted 7 April, 2019; v1 submitted 7 November, 2018;
originally announced November 2018.
-
Effects of nongaussian diffusion on "isotropic diffusion measurements'': an ex-vivo microimaging and simulation study
Authors:
Sune Nørhøj Jespersen,
Jonas Lynge Olesen,
Andrada Ianuş,
Noam Shemesh
Abstract:
Designing novel diffusion-weighted pulse sequences to probe tissue microstructure beyond the conventional Stejskal-Tanner family is currently of broad interest. One such technique, multidimensional diffusion MRI, has been recently proposed to afford model-free decomposition of diffusion signal kurtosis into terms originating from either ensemble variance of isotropic diffusivity or microscopic dif…
▽ More
Designing novel diffusion-weighted pulse sequences to probe tissue microstructure beyond the conventional Stejskal-Tanner family is currently of broad interest. One such technique, multidimensional diffusion MRI, has been recently proposed to afford model-free decomposition of diffusion signal kurtosis into terms originating from either ensemble variance of isotropic diffusivity or microscopic diffusion anisotropy. This ability rests on the assumption that diffusion can be described as a sum of multiple Gaussian compartments, but this is often not strictly fulfilled. The effects of nongaussian diffusion on single shot isotropic diffusion sequences were first considered in detail by de Swiet and Mitra in 1996. They showed theoretically that anisotropic compartments lead to anisotropic time dependence of the diffusion tensors, which causes the measured isotropic diffusivity to depend on gradient frame orientation. Here we show how such deviations from the multiple Gaussian compartments assumption conflates orientation dispersion with ensemble variance in isotropic diffusivity. Second, we consider additional contributions to the apparent variance in isotropic diffusivity arising due to intracompartmental kurtosis. These will likewise depend on gradient frame orientation. We illustrate the potential importance of these confounds with analytical expressions, numerical simulations in simple model geometries, and microimaging experiments in fixed spinal cord using isotropic diffusion encoding waveforms with 7.5 ms duration and 3000 mT/m maximum amplitude.
△ Less
Submitted 4 February, 2019; v1 submitted 6 December, 2017;
originally announced December 2017.
-
Accurate estimation of microscopic diffusion anisotropy and its time dependence in the mouse brain
Authors:
Andrada Ianuş,
Sune N. Jespersen,
Teresa Serradas Duarte,
Daniel C. Alexander,
Ivana Drobnjak,
Noam Shemesh
Abstract:
Microscopic diffusion anisotropy (μA) has been recently gaining increasing attention for its ability to decouple the average compartment anisotropy from orientation dispersion. Advanced diffusion MRI sequences, such as double diffusion encoding (DDE) and double oscillating diffusion encoding (DODE) have been used for map** μA. However, the time-dependence of μA has not been investigated insofar,…
▽ More
Microscopic diffusion anisotropy (μA) has been recently gaining increasing attention for its ability to decouple the average compartment anisotropy from orientation dispersion. Advanced diffusion MRI sequences, such as double diffusion encoding (DDE) and double oscillating diffusion encoding (DODE) have been used for map** μA. However, the time-dependence of μA has not been investigated insofar, and furthermore, the accuracy of μA estimation vis-à-vis different b-values was not assessed. Here, we investigate both these concepts using theory, simulation, and experiments in the mouse brain. In the first part, simulations and experimental results show that the conventional estimation of microscopic anisotropy from the difference of D(O)DE sequences with parallel and orthogonal gradient directions yields values that highly depend on the choice of b-value. To mitigate this undesirable bias, we propose a multi-shell approach that harnesses a polynomial fit of the signal difference up to third order terms in b-value. In simulations, this approach yields more accurate μA metrics, which are similar to the ground truth values. The second part of this work uses the proposed multi-shell method to estimate the time/frequency dependence of μA. The data shows either an increase or no change in μA with frequency depending on the region of interest, both in white and gray matter. When comparing the experimental results with simulations, it emerges that simple geometric models such as infinite cylinders with either negligible or finite radii cannot replicate the measured trend, and more complex models, which, for example, incorporate structure along the fibre direction are required. Thus, measuring the time dependence of microscopic anisotropy can provide valuable information for characterizing tissue microstructure.
△ Less
Submitted 21 March, 2019; v1 submitted 5 December, 2017;
originally announced December 2017.
-
Diffusion time dependence of microstructural parameters in fixed spinal cord
Authors:
Sune Nørhøj Jespersen,
Jonas Lynge Olesen,
Brian Hansen,
Noam Shemesh
Abstract:
Biophysical modelling of diffusion MRI is necessary to provide specific microstructural tissue properties. However, estimating model parameters from data with limited diffusion gradient strength, such as clinical scanners, has proven unreliable due to a shallow optimization landscape. On the other hand, estimation of diffusion kurtosis (DKI) parameters is more robust as the clinical acquisitions t…
▽ More
Biophysical modelling of diffusion MRI is necessary to provide specific microstructural tissue properties. However, estimating model parameters from data with limited diffusion gradient strength, such as clinical scanners, has proven unreliable due to a shallow optimization landscape. On the other hand, estimation of diffusion kurtosis (DKI) parameters is more robust as the clinical acquisitions typically probe a regime in which the associated 4th order cumulant expansion is adequate; however, its parameters are not microstructurally specific a priori. Given an appropriate biophysical model, its parameters may be connected to DKI parameters, but it was previously shown that at the DKI level, it still does not provide sufficient information to uniquely determine all model parameters. Earlier work has shown that by neglecting axonal dispersion, this parameter degeneracy reduces to the question of whether intra-axonal diffusivity is larger than or smaller than extra-axonal diffusivity. Here we develop a model of diffusion in spinal cord white matter including axonal dispersion and demonstrate stable estimation of all model parameters from DKI. By employing the recently developed fast axisymmetric DKI, we use stimulated echo acquisition mode to collect data over an unprecedented diffusion time range with very narrow diffusion gradient pulses, enabling finely resolved measurements of diffusion time dependence of both net diffusion and kurtosis metrics, as well as model intra- and extra-axonal diffusivities, and axonal dispersion. Our results demonstrate substantial time dependence of all parameters except volume fractions, and the additional time dimension provides support for intra-axonal diffusivity to be larger than extra-axonal diffusivity in spinal cord white matter, although not unambiguously. We compare our findings to predictions from effective medium theory.
△ Less
Submitted 19 March, 2019; v1 submitted 10 May, 2017;
originally announced May 2017.
-
White matter biomarkers from fast protocols using axially symmetric diffusion kurtosis imaging
Authors:
Brian Hansen,
Ahmad R. Khan,
Noam Shemesh,
Torben E. Lund,
Ryan Sangill,
Simon F. Eskildsen,
Leif Østergaard,
Sune N. Jespersen
Abstract:
White matter tract integrity (WMTI) can characterize brain microstructure in areas with highly aligned fiber bundles. Several WMTI biomarkers have now been validated against microscopy and provided promising results in studies of brain development and aging, and in a number of brain disorders. Currently, WMTI is mostly used in dedicated animal studies and clinical studies of slowly progressing dis…
▽ More
White matter tract integrity (WMTI) can characterize brain microstructure in areas with highly aligned fiber bundles. Several WMTI biomarkers have now been validated against microscopy and provided promising results in studies of brain development and aging, and in a number of brain disorders. Currently, WMTI is mostly used in dedicated animal studies and clinical studies of slowly progressing diseases but has not yet emerged as a routine clinical tool. To this end, a less data intensive experimental method would be beneficial by enabling high resolution validation studies, and ease clinical applications by speeding up data acquisition compared to typical diffusion kurtosis imaging (DKI) protocols utilized as part of WMTI imaging. Here, we evaluate WMTI based on recently introduced axially symmetric DKI which has lower data demand than conventional DKI. We compare WMTI parameters derived from conventional DKI to those calculated analytically from axially symmetric DKI. We employ numerical simulations, as well as data from fixed rat spinal cord (1) and in vivo human (3) and rat brain (4). Our analysis shows that analytical WMTI based on axially symmetric DKI with sparse data sets (19 images) produces WMTI metrics that correlate strongly with estimates based on traditional DKI data sets (60 images or more). We demonstrate the preclinical potential of the proposed WMTI technique in in vivo rat brain (300 μm isotropic resolution with whole brain coverage). WMTI parameter estimates are subject to a duality leading to two solution branches dependent on a sign choice which is currently debated. Results from both of these branches are presented and discussed throughout our analysis. The proposed fast WMTI approach may be useful for preclinical research and e.g. clinical evaluation of patients with traumatic white matter injuries or symptoms of neurovascular or neuroinflammatory disorders.
△ Less
Submitted 11 May, 2017; v1 submitted 10 October, 2016;
originally announced October 2016.
-
Map** axonal density and average diameter using non-monotonic time-dependent gradient-echo MRI
Authors:
Daniel Nunes,
Tomas L Cruz,
Sune N Jespersen,
Noam Shemesh
Abstract:
This paper presents a novel method for quantifying axonal density and diameter using simple multiple gradient echo (MGE) MRI
This paper presents a novel method for quantifying axonal density and diameter using simple multiple gradient echo (MGE) MRI
△ Less
Submitted 27 February, 2017; v1 submitted 9 September, 2016;
originally announced September 2016.
-
Coherent dynamical recoupling of diffusion-driven decoherence in magnetic resonance
Authors:
Gonzalo A. Alvarez,
Noam Shemesh,
Lucio Frydman
Abstract:
During recent years, dynamical decoupling (DD) has gained relevance as a tool for manipulating quantum systems and extracting information from them. This is particularly relevant for spins involved in nuclear magnetic resonance (NMR), where DD sequences can be used to prolong quantum coherences, or for selectively couple/decouple the effects imposed by random environmental fluctuations. In this Le…
▽ More
During recent years, dynamical decoupling (DD) has gained relevance as a tool for manipulating quantum systems and extracting information from them. This is particularly relevant for spins involved in nuclear magnetic resonance (NMR), where DD sequences can be used to prolong quantum coherences, or for selectively couple/decouple the effects imposed by random environmental fluctuations. In this Letter, we show that one can exploit these concepts in order to selectively recouple diffusion processes in restricted spaces. The ensuing method provides a novel tool to measure restriction lengths in confined systems such as capillaries, pores or cells. The principles of this method for selectively recoupling diffusion-driven decoherence, its standing within the context of diffusion NMR, and corroborating experiments, are presented.
△ Less
Submitted 7 September, 2014; v1 submitted 13 May, 2013;
originally announced May 2013.