A Vacuum-Compatible Cylindrical Inertial Rotation Sensor with Picoradian Sensitivity
Authors:
M. P. Ross,
J. van Dongen,
Y. Huang,
P. Zhou,
Y. Chowdhury,
S. K. Apple,
C. M. Mow-Lowry,
A. L. Mitchell,
N. A. Holland,
B. Lantz,
E. Bonilla,
A. Engl,
A. Pele,
D. Griffith,
E. Sanchez,
E. A. Shaw,
C. Gettings,
J. H. Gundlach
Abstract:
We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adj…
▽ More
We describe an inertial rotation sensor with a 30-cm cylindrical proof-mass suspended from a pair of 14-$μ$m thick BeCu flexures. The angle between the proof-mass and support structure is measured with a pair of homodyne interferometers which achieve a noise level of $\sim 5\ \text{prad}/\sqrt{\text{Hz}}$. The sensor is entirely made of vacuum compatible materials and the center of mass can be adjusted remotely.
△ Less
Submitted 14 September, 2023; v1 submitted 11 July, 2023;
originally announced July 2023.
-
A Pseudo Plane-wave Gravitational Calibrator for Gravitational Wave Observatories
Authors:
M. P. Ross,
J. H. Gundlach,
E. G. Adelberger,
C. M. Weller,
E. A. Shaw,
C. Gettings,
J. Kissel,
T. Mistry,
L. Datrier,
E. Daw,
M. Hendry
Abstract:
The precisions of existing gravitational calibrators for gravitational wave observatories are limited by their dependence on the relative position between the calibrators and the observatory's test masses. Here we present a novel geometry consisting of four quadrupole rotors placed at the vertices of a rectangle centered on the test mass. The phases and rotation directions are selected to produce…
▽ More
The precisions of existing gravitational calibrators for gravitational wave observatories are limited by their dependence on the relative position between the calibrators and the observatory's test masses. Here we present a novel geometry consisting of four quadrupole rotors placed at the vertices of a rectangle centered on the test mass. The phases and rotation directions are selected to produce a pseudo plane-wave sinusoidal gravitational acceleration with amplitude of ~ 100 fm/s^2. We show that this acceleration only has minimal dependence on the test mass position relative to the rotor array and can yield 0.15% acceleration amplitude uncertainty while tolerating a 1-cm test mass position uncertainty. The acceleration can be directed precisely along the optical axis of the interferometer arm and applies no torque on the test mass. In addition, the small size of the rotors has significant engineering and safety benefits.
△ Less
Submitted 25 January, 2023;
originally announced January 2023.
-
A Cryogenic Torsion Balance Using a Liquid-Cryogen Free, Ultra-Low Vibration Cryostat
Authors:
S. M. Fleischer,
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
E. A. Shaw,
E. Swanson,
B. R. Heckel,
J. H. Gundlach
Abstract:
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency…
▽ More
We describe a liquid-cryogen free cryostat with ultra-low vibration levels which allows for continuous operation of a torsion balance at cryogenic temperatures. The apparatus uses a commercially available two-stage pulse-tube cooler and passive vibration isolation. The torsion balance exhibits torque noise levels lower than room temperature thermal noise by a factor of about four in the frequency range of 3-10mHz, limited by residual seismic motion and by radiative heating of the pendulum body. In addition to lowering thermal noise below room-temperature limits, the low-temperature environment enables novel torsion balance experiments. Currently, the maximum duration of a continuous measurement run is limited by accumulation of cryogenic surface contamination on the optical elements inside the cryostat.
△ Less
Submitted 8 November, 2022; v1 submitted 6 June, 2022;
originally announced June 2022.
-
A torsion-balance search for ultra low-mass bosonic dark matter
Authors:
E. A. Shaw,
M. P. Ross,
C. A. Hagedorn,
E. G. Adelberger,
J. H. Gundlach
Abstract:
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining…
▽ More
We used a stationary torsion balance with a beryllium-aluminum composition dipole to search for ultra low-mass bosonic dark matter coupled to baryon minus lepton number. We set 95% confidence limits on the coupling constant $g_{\rm B-L}$ for bosons with masses between $10^{-18}$ and $10^{-16}$ eV/$c^2$ with the best performance at $m_{\rm DM} = 8\times 10^{-18}$ eV/$c^2$ constraining $g_{B-L}(\hbar c)^{-1/2} < 1 \times 10^{-25}$. This provides a complimentary limit to equivalence-principle experiments that search for ultra low-mass bosons as force-mediating particles.
△ Less
Submitted 10 January, 2022; v1 submitted 17 September, 2021;
originally announced September 2021.
-
A Low-Frequency Torsion Pendulum with Interferometric Readout
Authors:
M. P. Ross,
K. Venkateswara,
C. A. Hagedorn,
C. J. Leupold,
P. W. F. Forsyth,
J. D. Wegner,
E. A. Shaw,
J. G. Lee,
J. H. Gundlach
Abstract:
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rota…
▽ More
We describe a torsion pendulum with a large mass-quadrupole moment and a resonant frequency of 2.8 mHz, whose angle is measured using a modified Michelson interferometer. The system achieved noise levels of $\sim200\ \text{prad}/\sqrt{\text{Hz}}$ between 0.2-30 Hz and $\sim10\ \text{prad}/\sqrt{\text{Hz}}$ above 100 Hz. Such a system can be applied to a broad range of fields from the study of rotational seismic motion and elastogravity signals to gravitational wave observation and tests of gravity.
△ Less
Submitted 20 April, 2021; v1 submitted 4 January, 2021;
originally announced January 2021.
-
Limits on the Stochastic Gravitational Wave Background and Prospects for Single Source Detection with GRACE Follow-On
Authors:
M. P. Ross,
C. A. Hagedorn,
E. A. Shaw,
A. L. Lockwood,
B. M. Iritani,
J. G. Lee,
K. Venkateswara,
J. H. Gundlach
Abstract:
With a reinterpretation of recent results, the GRACE Follow-On mission can be applied to gravitational wave astronomy. Existing GRACE Follow-On data constrain the stochastic gravitational wave background to $Ω_{GW}<3.3\times10^{7}$ at 100 mHz. With a dedicated analysis, GRACE Follow-On may be able to detect the inspiral of local neutron star binaries, inspiral of subgalactic stellar-mass black hol…
▽ More
With a reinterpretation of recent results, the GRACE Follow-On mission can be applied to gravitational wave astronomy. Existing GRACE Follow-On data constrain the stochastic gravitational wave background to $Ω_{GW}<3.3\times10^{7}$ at 100 mHz. With a dedicated analysis, GRACE Follow-On may be able to detect the inspiral of local neutron star binaries, inspiral of subgalactic stellar-mass black hole binaries, or mergers of intermediate-mass black hole binaries within the Milky Way.
△ Less
Submitted 13 May, 2020; v1 submitted 5 February, 2020;
originally announced February 2020.