Longitudinal spin-relaxation optimization for miniaturized optically pumped magnetometers
Authors:
A. P. McWilliam,
S. Dyer,
D. Hunter,
M. Mrozowski,
S. J. Ingleby,
O. Sharp,
D. P. Burt,
P. F. Griffin,
J. P. McGilligan,
E. Riis
Abstract:
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal re…
▽ More
The microfabrication of cesium vapor cells for optically pumped magnetometry relies on optimization of buffer gas pressure in order to maximize atomic coherence time and sensitivity to external magnetic signals. We demonstrate post-bond nitrogen buffer gas pressure tuning through localized heating of an integrated micro-pill dispenser. We characterize the variation in the intrinsic longitudinal relaxation rate, $γ_{10}$, and magnetic sensitivity, as a function of the resulting nitrogen buffer gas pressure. Measurements are conducted through employing an optically pumped magnetometer operating in a free-induction-decay configuration. $γ_{10}$ is extracted across a range of nitrogen pressures between $\sim$~60~-~700~Torr, measuring a minimum of 140~Hz at 115~Torr. Additionally, we achieve sensitivities as low as 130 ~fT/$\sqrt{\text{Hz}}$ at a bias field amplitude of $\sim 50~μ$T. With the optimal nitrogen buffer gas pressure now quantified and achievable post-fabrication, these mass-producible cells can be tailored to suit a variety of sensing applications, ensuring peak magnetometer performance.
△ Less
Submitted 3 July, 2024; v1 submitted 27 June, 2024;
originally announced June 2024.
Real-time buffer gas pressure tuning in a micro-machined vapor cell
Authors:
S. Dyer,
A. McWilliam,
D. Hunter,
S. Ingleby,
D. P. Burt,
O. Sharp,
F. Mirando,
P. F. Griffin,
E. Riis,
J. P. McGilligan
Abstract:
We demonstrate a controllable depletion of the nitrogen buffer gas pressure in a micro-machined cesium (Cs) vapor cell from the dynamic heating of an alkali dispenser pill. When the alkali source is laser activated, the gettering compounds within the alkali pill dispenser reduce the nitrogen (N$_2$) content from the vapor for fine-tuning of the alkali to buffer gas pressure ratio. Additionally, we…
▽ More
We demonstrate a controllable depletion of the nitrogen buffer gas pressure in a micro-machined cesium (Cs) vapor cell from the dynamic heating of an alkali dispenser pill. When the alkali source is laser activated, the gettering compounds within the alkali pill dispenser reduce the nitrogen (N$_2$) content from the vapor for fine-tuning of the alkali to buffer gas pressure ratio. Additionally, we decrease the buffer gas pressure below 100$\,$mTorr to evaluate the presence of other potential broadening mechanisms. Real-time control of the gas pressure ratio in the vapor cell will have notable benefits for refining atomic sensor performance and provide a routine to achieve various target pressures across a wafer bonded with a uniform back-filled buffer gas pressure.
△ Less
Submitted 12 April, 2023;
originally announced April 2023.