-
An experimental search for an explanation of the difference between beam and bottle neutron lifetime measurements
Authors:
M. F. Blatnik,
L. S. Blokland,
N. Callahan,
J. H. Choi,
S. Clayton,
C. B Cude-Woods,
B. W. Filippone,
W. R. Fox,
E. Fries,
P. Geltenbort,
F. M. Gonzalez,
L. Hayen,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
A. Komives,
S Lin,
Chen-Yu Liu,
M. F. Makela,
C. L. Morris,
R. Musedinovic,
C. M. O'Shaughnessy,
R. W. Pattie Jr.,
J. C. Ramsey,
D. J. Salvat
, et al. (10 additional authors not shown)
Abstract:
The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently publi…
▽ More
The past two decades have yielded several new measurements and reanalysis of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the most precise lifetime measured in neutron storage experiments. Here we publish an analysis of the recently published UCN aimed a searching for an explanation of this difference using the model proposed by Koch and Hummel.
△ Less
Submitted 14 June, 2024;
originally announced June 2024.
-
Demonstration of Sub-micron UCN Position Resolution using Room-temperature CMOS Sensor
Authors:
S. Lin,
J. K. Baldwin,
M. Blatnik,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
B. Filippone,
E. M. Fries,
P. Geltenbort,
A. T. Holley,
W. Li,
C. Y. Liu,
M. Makela,
C. L. Morris,
R. Musedinovic,
C. O'Shaughnessy,
R. W. Pattie,
D. J. Salvat,
A. Saunders,
E. I. Sharapov,
M. Singh,
X. Sun,
Z. Tang,
W. Uhrich,
W. Wei
, et al. (3 additional authors not shown)
Abstract:
High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics-informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-tempera…
▽ More
High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics-informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work [1, 2] that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully-connected neural network (FCNN) to learn a map** from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.
△ Less
Submitted 16 May, 2023;
originally announced May 2023.
-
Measurement of the Parity-Odd Angular Distribution of Gamma Rays From Polarized Neutron Capture on $^{35}$Cl
Authors:
N. Fomin,
R. Alarcon,
L. Alonzi,
E. Askanazi,
S. Baeßler,
S. Balascuta,
L. Barrón-Palos,
A. Barzilov,
D. Blyth,
J. D. Bowman,
N. Birge,
J. R. Calarco,
T. E. Chupp,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
K. Craycraft,
D. Evans,
C. Fieseler,
E. Frlež,
J. Fry,
I. Garishvili,
M. T. W. Gericke,
R. C. Gillis,
K. B. Grammer
, et al. (39 additional authors not shown)
Abstract:
We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the ${}^{35}$Cl nucleus, one parity-odd correlation proportional to $\vec{s_{n}} \cdot \vec{k_γ}$ and one parity-even correlation proportional to $\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}$. A parity violating asymmetry can appear in this reaction due to the weak nucleon-n…
▽ More
We report a measurement of two energy-weighted gamma cascade angular distributions from polarized slow neutron capture on the ${}^{35}$Cl nucleus, one parity-odd correlation proportional to $\vec{s_{n}} \cdot \vec{k_γ}$ and one parity-even correlation proportional to $\vec{s_{n}} \cdot \vec{k_{n}} \times \vec{k_γ}$. A parity violating asymmetry can appear in this reaction due to the weak nucleon-nucleon (NN) interaction which mixes opposite parity S and P-wave levels in the excited compound $^{36}$Cl nucleus formed upon slow neutron capture. If parity-violating (PV) and parity-conserving (PC) terms both exist, the measured differential cross section can be related to them via $\frac{dσ}{dΩ}\propto1+A_{γ, PV}\cosθ+A_{γ,PC}\sinθ$. The PV and PC asymmetries for energy-weighted gamma cascade angular distributions for polarized slow neutron capture on $^{35}$Cl averaged over the neutron energies from 2.27~meV to 9.53~meV were measured to be $A_{γ,PV}=(-23.9\pm0.7)\times 10^{-6}$ and $A_{γ,PC}=(0.1\pm0.7)\times 10^{-6}$. These results are consistent with previous experimental results. Systematic errors were quantified and shown to be small compared to the statistical error. These asymmetries in the angular distributions of the gamma rays emitted from the capture of polarized neutrons in $^{35}$Cl were used to verify the operation and data analysis procedures for the NPDGamma experiment which measured the parity-odd asymmetry in the angular distribution of gammas from polarized slow neutron capture on protons.
△ Less
Submitted 22 July, 2022;
originally announced July 2022.
-
Fill and dump measurement of the neutron lifetime using an asymmetric magneto-gravitational trap
Authors:
C. Cude-Woods,
F. M. Gonzalez,
E. M. Fries,
T. Bailey,
M. Blatnik,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
S. A. Currie,
M. Dawid,
B. W. Filippone,
W. Fox,
P. Geltenbort,
E. George,
L. Hayen,
K. P. Hickerson,
M. A. Hoffbauer,
K. Hoffman,
A. T. Holley,
T. M. Ito,
A. Komives,
C. -Y. Liu,
M. Makela,
C. L. Morris,
R. Musedinovic
, et al. (17 additional authors not shown)
Abstract:
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for inve…
▽ More
The past two decades have yielded several new measurements and reanalyses of older measurements of the neutron lifetime. These have led to a 4.4 standard deviation discrepancy between the most precise measurements of the neutron decay rate producing protons in cold neutron beams and the lifetime measured in neutron storage experiments. Measurements using different techniques are important for investigating whether there are unidentified systematic effects in any of the measurements. In this paper we report a new measurement using the Los Alamos asymmetric magneto-gravitational trap where the surviving neutrons are counted external to the trap using the fill and dump method. The new measurement gives a free neutron lifetime of . Although this measurement is not as precise, it is in statistical agreement with previous results using in situ counting in the same apparatus.
△ Less
Submitted 4 May, 2022;
originally announced May 2022.
-
Improved neutron lifetime measurement with UCN$τ$
Authors:
F. M. Gonzalez,
E. M. Fries,
C. Cude-Woods,
T. Bailey,
M. Blatnik,
L. J. Broussard,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
S. A. Currie,
M. Dawid,
E. B. Dees,
B. W. Filippone,
W. Fox,
P. Geltenbort,
E. George,
L. Hayen,
K. P. Hickerson,
M. A. Hoffbauer,
K. Hoffman,
A. T. Holley,
T. M. Ito,
A. Komives,
C. -Y. Liu,
M. Makela
, et al. (19 additional authors not shown)
Abstract:
We report an improved measurement of the free neutron lifetime $τ_{n}$ using the UCN$τ$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$τ$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $τ_{n}$ from three blinded, independent analyses by bo…
▽ More
We report an improved measurement of the free neutron lifetime $τ_{n}$ using the UCN$τ$ apparatus at the Los Alamos Neutron Science Center. We counted a total of approximately $38\times10^{6}$ surviving ultracold neutrons (UCN) after storing in UCN$τ$'s magneto-gravitational trap over two data acquisition campaigns in 2017 and 2018. We extract $τ_{n}$ from three blinded, independent analyses by both pairing long and short storage-time runs to find a set of replicate $τ_{n}$ measurements and by performing a global likelihood fit to all data while self-consistently incorporating the $β$-decay lifetime. Both techniques achieve consistent results and find a value $τ_{n}=877.75\pm0.28_{\text{ stat}}+0.22/-0.16_{\text{ syst}}$~s. With this sensitivity, neutron lifetime experiments now directly address the impact of recent refinements in our understanding of the standard model for neutron decay.
△ Less
Submitted 21 September, 2021; v1 submitted 18 June, 2021;
originally announced June 2021.
-
Improved limits on Fierz Interference using asymmetry measurements from the UCNA experiment
Authors:
Xuan Sun,
E. Adamek,
B. Allgeier,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
S. Hasan,
K. P. Hickerson,
J. Hoagland,
R. Hong,
A. T. Holley,
T. M. Ito,
A. Knecht
, et al. (34 additional authors not shown)
Abstract:
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sens…
▽ More
The Ultracold Neutron Asymmetry (UCNA) experiment was designed to measure the $β$-decay asymmetry parameter, $A_0$, for free neutron decay. In the experiment, polarized ultracold neutrons are transported into a decay trap, and their $β$-decay electrons are detected with $\approx 4π$ acceptance into two detector packages which provide position and energy reconstruction. The experiment also has sensitivity to $b_{n}$, the Fierz interference term in the neutron $β$-decay rate. In this work, we determine $b_{n}$ from the energy dependence of $A_0$ using the data taken during the UCNA 2011-2013 run. In addition, we present the same type of analysis using the earlier 2010 $A$ dataset. Motivated by improved statistics and comparable systematic errors compared to the 2010 data-taking run, we present a new $b_{n}$ measurement using the weighted average of our asymmetry dataset fits, to obtain $b_{n} = 0.066 \pm 0.041_{\text{stat}} \pm 0.024_{\text{syst}}$ which corresponds to a limit of $-0.012 < b_{n} < 0.144$ at the 90% confidence level.
△ Less
Submitted 13 November, 2019;
originally announced November 2019.
-
Final results for the neutron $β$-asymmetry parameter $A_0$ from the UCNA experiment
Authors:
B. Plaster,
E. Adamek,
B. Allgeier,
J. Anaya,
H. O. Back,
Y. Bagdasarova,
D. B. Berguno,
M. Blatnik,
J. G. Boissevain,
T. J. Bowles,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
D. J. Clark,
S. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
S. Du,
B. W. Filippone,
A. Garcia,
P. Geltenbort,
S. Hasan,
A. Hawari
, et al. (69 additional authors not shown)
Abstract:
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the…
▽ More
The UCNA experiment was designed to measure the neutron $β$-asymmetry parameter $A_0$ using polarized ultracold neutrons (UCN). UCN produced via downscattering in solid deuterium were polarized via transport through a 7 T magnetic field, and then directed to a 1 T solenoidal electron spectrometer, where the decay electrons were detected in electron detector packages located on the two ends of the spectrometer. A value for $A_0$ was then extracted from the asymmetry in the numbers of counts in the two detector packages. We summarize all of the results from the UCNA experiment, obtained during run periods in 2007, 2008--2009, 2010, and 2011--2013, which ultimately culminated in a 0.67\% precision result for $A_0$.
△ Less
Submitted 10 April, 2019;
originally announced April 2019.
-
A boron-coated CCD camera for direct detection of Ultracold Neutrons (UCN)
Authors:
K. Kuk,
C. Cude-Woods,
C. R. Chavez,
J. H. Choi,
J. Estrada,
M. Hoffbauer,
M. Makela,
P. Merkel,
C. L. Morris,
E. Ramberg,
Z. Wang,
T. Bailey,
M. Blatnik,
E. R. Adamek,
L. J. Broussard,
M. A. -P. Brown,
N. B. Callahan,
S. M. Clayton,
S. A. Currie,
X. Ding,
D. Dinger,
B. Filippone,
E. M. Fries,
P. Geltenbort,
E. George
, et al. (26 additional authors not shown)
Abstract:
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolutio…
▽ More
A new boron-coated CCD camera is described for direct detection of ultracold neutrons (UCN) through the capture reactions $^{10}$B (n,$α$0$γ$)$^7$Li (6%) and $^{10}$B(n,$α$1$γ$)$^7$Li (94%). The experiments, which extend earlier works using a boron-coated ZnS:Ag scintillator, are based on direct detections of the neutron-capture byproducts in silicon. The high position resolution, energy resolution and particle ID performance of a scientific CCD allows for observation and identification of all the byproducts $α$, $^7$Li and $γ$ (electron recoils). A signal-to-noise improvement on the order of 10$^4$ over the indirect method has been achieved. Sub-pixel position resolution of a few microns is demonstrated. The technology can also be used to build UCN detectors with an area on the order of 1 m$^2$. The combination of micrometer scale spatial resolution, few electrons ionization thresholds and large area paves the way to new research avenues including quantum physics of UCN and high-resolution neutron imaging and spectroscopy.
△ Less
Submitted 28 February, 2019;
originally announced March 2019.
-
Experimental Upper Bound and Theoretical Expectations for Parity-Violating Neutron Spin Rotation in 4He
Authors:
H. E. Swanson,
C. D. Bass,
T. D. Bass,
B. E. Crawford,
J. M. Dawkins,
K. Gan,
B. R. Heckel,
J. C. Horton,
C. Huffer,
D. Luo,
D. M. Markoff,
A. M. Micherdzinska,
H. P. Mumm,
J. S. Nico,
M. Sarsour,
E. I. Sharapov,
W. M. Snow,
S. B. Walbridge,
V. Zhumabekova
Abstract:
Neutron spin rotation is expected from quark-quark weak interactions in the Standard Model, which induce weak interactions among nucleons that violate parity. We present the results from an experiment searching for the effect of parity violation via the spin rotation of polarized neutrons in a liquid $^{4}$He medium. The value for the neutron spin rotation angle per unit length in $^{4}$He,…
▽ More
Neutron spin rotation is expected from quark-quark weak interactions in the Standard Model, which induce weak interactions among nucleons that violate parity. We present the results from an experiment searching for the effect of parity violation via the spin rotation of polarized neutrons in a liquid $^{4}$He medium. The value for the neutron spin rotation angle per unit length in $^{4}$He, $dφ/dz =(+2.1 \pm 8.3 (stat.) \pm 2.9 (sys.))\times10^{-7}$ rad/m, is consistent with zero. The result agrees with the best current theoretical estimates of the size of nucleon-nucleon weak amplitudes from other experiments and with the expectations from recent theoretical approaches to weak nucleon-nucleon interactions. In this paper we review the theoretical status of parity violation in the $\vec{n}+^{4}$He system and discuss details of the data analysis leading to the quoted result. Analysis tools are presented that quantify systematic uncertainties in this measurement and that are expected to be essential for future measurements.
△ Less
Submitted 22 July, 2019; v1 submitted 21 February, 2019;
originally announced February 2019.
-
Monte Carlo Simulations of Trapped Ultracold Neutrons in the UCNτ Experiment
Authors:
Nathan Callahan,
Chen-Yu Liu,
Francisco Gonzalez,
Evan Adamek,
James David Bowman,
Leah Broussard,
S. M. Clayton,
S. Currie,
C. Cude-Woods,
E. B. Dees,
X. Ding,
E. M. Egnel,
D. Fellers,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
R. W. Pattie Jr,
J. Ramsey
, et al. (15 additional authors not shown)
Abstract:
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neut…
▽ More
In the UCNτ experiment, ultracold neutrons (UCN) are confined by magnetic fields and the Earth's gravitational field. Field-trap** mitigates the problem of UCN loss on material surfaces, which caused the largest correction in prior neutron experiments using material bottles. However, the neutron dynamics in field traps differ qualitatively from those in material bottles. In the latter case, neutrons bounce off material surfaces with significant diffusivity and the population quickly reaches a static spatial distribution with a density gradient induced by the gravitational potential. In contrast, the field-confined UCN -- whose dynamics can be described by Hamiltonian mechanics -- do not exhibit the stochastic behaviors typical of an ideal gas model as observed in material bottles. In this report, we will describe our efforts to simulate UCN trap** in the UCNτ magneto-gravitational trap. We compare the simulation output to the experimental results to determine the parameters of the neutron detector and the input neutron distribution. The tuned model is then used to understand the phase space evolution of neutrons observed in the UCNτ experiment. We will discuss the implications of chaotic dynamics on controlling the systematic effects, such as spectral cleaning and microphonic heating, for a successful UCN lifetime experiment to reach a 0.01% level of precision.
△ Less
Submitted 16 October, 2018;
originally announced October 2018.
-
First Observation of $P$-odd $γ$ Asymmetry in Polarized Neutron Capture on Hydrogen
Authors:
D. Blyth,
J. Fry,
N. Fomin,
R. Alarcon,
L. Alonzi,
E. Askanazi,
S. Baeßler,
S. Balascuta,
L. Barrón-Palos,
A. Barzilov,
J. D. Bowman,
N. Birge,
J. R. Calarco,
T. E. Chupp,
V. Cianciolo,
C. E. Coppola,
C. B. Crawford,
K. Craycraft,
D. Evans,
C. Fieseler,
E. Frlež,
I. Garishvili,
M. T. W. Gericke,
R. C. Gillis,
K. B. Grammer
, et al. (39 additional authors not shown)
Abstract:
We report the first observation of the parity-violating 2.2 MeV gamma-ray asymmetry $A^{np}_γ$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. $A^{np}_γ$ isolates the $ΔI=1$, \mbox{$^{3}S_{1}\rightarrow {^{3}P_{1}}$} component of the weak nucleon-nucleon interaction, which is dominat…
▽ More
We report the first observation of the parity-violating 2.2 MeV gamma-ray asymmetry $A^{np}_γ$ in neutron-proton capture using polarized cold neutrons incident on a liquid parahydrogen target at the Spallation Neutron Source at Oak Ridge National Laboratory. $A^{np}_γ$ isolates the $ΔI=1$, \mbox{$^{3}S_{1}\rightarrow {^{3}P_{1}}$} component of the weak nucleon-nucleon interaction, which is dominated by pion exchange and can be directly related to a single coupling constant in either the DDH meson exchange model or pionless EFT. We measured $A^{np}_γ= [-3.0 \pm 1.4 (stat) \pm 0.2 (sys)]\times 10^{-8}$, which implies a DDH weak $πNN$ coupling of $h_π^{1} = [2.6 \pm 1.2(stat) \pm 0.2(sys)] \times 10^{-7}$ and a pionless EFT constant of $C^{^{3}S_{1}\rightarrow ^{3}P_{1}}/C_{0}=[-7.4 \pm 3.5 (stat) \pm 0.5 (sys)] \times 10^{-11}$ MeV$^{-1}$. We describe the experiment, data analysis, systematic uncertainties, and the implications of the result.
△ Less
Submitted 14 December, 2018; v1 submitted 26 July, 2018;
originally announced July 2018.
-
Performance of the upgraded ultracold neutron source at Los Alamos National Laboratory and its implication for a possible neutron electric dipole moment experiment
Authors:
T. M. Ito,
E. R. Adamek,
N. B. Callahan,
J. H. Choi,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
X. Ding,
D. E. Fellers,
P. Geltenbort,
S. K. Lamoreaux,
C. Y. Liu,
S. MacDonald,
M. Makela,
C. L. Morris,
R. W. Pattie Jr.,
J. C. Ramsey,
D. J. Salvat,
A. Saunders,
E. I. Sharapov,
S. Sjue,
A. P. Sprow,
Z. Tang,
H. L. Weaver,
W. Wei
, et al. (1 additional authors not shown)
Abstract:
The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the…
▽ More
The ultracold neutron (UCN) source at Los Alamos National Laboratory (LANL), which uses solid deuterium as the UCN converter and is driven by accelerator spallation neutrons, has been successfully operated for over 10 years, providing UCN to various experiments, as the first production UCN source based on the superthermal process. It has recently undergone a major upgrade. This paper describes the design and performance of the upgraded LANL UCN source. Measurements of the cold neutron spectrum and UCN density are presented and compared to Monte Carlo predictions. The source is shown to perform as modeled. The UCN density measured at the exit of the biological shield was $184(32)$ UCN/cm$^3$, a four-fold increase from the highest previously reported. The polarized UCN density stored in an external chamber was measured to be $39(7)$ UCN/cm$^3$, which is sufficient to perform an experiment to search for the nonzero neutron electric dipole moment with a one-standard-deviation sensitivity of $σ(d_n) = 3\times 10^{-27}$ $e\cdot$cm.
△ Less
Submitted 16 January, 2018; v1 submitted 14 October, 2017;
originally announced October 2017.
-
Measurement of the neutron lifetime using an asymmetric magneto- gravitational trap and in situ detection
Authors:
R. W. Pattie Jr.,
N. B. Callahan,
C. Cude-Woods,
E. R. Adamek,
L. J. Broussard,
S. M. Clayton,
S. A. Currie,
E. B. Dees,
X. Ding,
E. M. Engel,
D. E. Fellers,
W. Fox,
K. P. Hickerson,
M. A. Hoffbauer,
A. T. Holley,
A. Komives,
C. -Y. Liu,
S. W. T. MacDonald,
M. Makela,
C. L. Morris,
J. D. Ortiz,
J. Ramsey,
D. J. Salvat,
A. Saunders,
S. J. Seestrom
, et al. (13 additional authors not shown)
Abstract:
The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay r…
▽ More
The precise value of the mean neutron lifetime, $τ_n$, plays an important role in nuclear and particle physics and cosmology. It is a key input for predicting the ratio of protons to helium atoms in the primordial universe and is used to search for new physics beyond the Standard Model of particle physics. There is a 3.9 standard deviation discrepancy between $τ_n$ measured by counting the decay rate of free neutrons in a beam (887.7 $\pm$ 2.2 s) and by counting surviving ultracold neutrons stored for different storage times in a material trap (878.5$\pm$0.8 s). The experiment described here eliminates loss mechanisms present in previous trap experiments by levitating polarized ultracold neutrons above the surface of an asymmetric storage trap using a repulsive magnetic field gradient so that the stored neutrons do not interact with material trap walls and neutrons in quasi-stable orbits rapidly exit the trap. As a result of this approach and the use of a new in situ neutron detector, the lifetime reported here (877.7 $\pm$ 0.7 (stat) +0.4/-0.2 (sys) s) is the first modern measurement of $τ_n$ that does not require corrections larger than the quoted uncertainties.
△ Less
Submitted 7 February, 2018; v1 submitted 6 July, 2017;
originally announced July 2017.
-
First direct constraints on Fierz interference in free neutron $β$ decay
Authors:
K. P. Hickerson,
X. Sun,
Y. Bagdasarova,
D. Bravo-Berguño,
L. J. Broussard,
M. A. -P. Brown,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
M. P. Mendenhall,
S. D. Moore
, et al. (18 additional authors not shown)
Abstract:
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding…
▽ More
Precision measurements of free neutron $β$-decay have been used to precisely constrain our understanding of the weak interaction. However the neutron Fierz interference term $b_n$, which is particularly sensitive to Beyond-Standard-Model tensor currents at the TeV scale, has thus far eluded measurement. Here we report the first direct constraints on this term, finding $b_n = 0.067 \pm 0.005_{\text{stat}} {}^{+0.090}_{- 0.061}{}_{\text{sys}}$, consistent with the Standard Model. The uncertainty is dominated by absolute energy reconstruction and the linearity of the beta spectrometer energy response.
△ Less
Submitted 8 July, 2017; v1 submitted 3 July, 2017;
originally announced July 2017.
-
A new method for measuring the neutron lifetime using an in situ neutron detector
Authors:
C. L. Morris,
E. R. Adamek,
L. J. Broussard,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. A. Currie,
X. Ding,
W. Fox,
K. P. Hickerson,
A. T. Holley,
A. Komives,
C. -Y. Liu,
M. Makela,
R. W. Pattie Jr.,
J. Ramsey,
D. J. Salvat,
A. Saunders,
S. J. Seestrom,
E. I. Sharapov,
S. K. Sjue,
Z. Tang,
J. Vanderwerp,
B. Vogelaar,
P. L. Walstrom
, et al. (6 additional authors not shown)
Abstract:
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron b…
▽ More
The neutron lifetime is important in understanding the production of light nuclei in the first minutes after the big bang and it provides basic information on the charged weak current of the standard model of particle physics. Two different methods have been used to measure the neutron lifetime: disappearance measurements using bottled ultracold neutrons and decay rate measurements using neutron beams. The best measurements using these two techniques give results that differ by nearly 4 standard deviations. In this paper we describe a new method for measuring surviving neutrons in neutron lifetime measurements using bottled ultracold neutrons that provides better characterization of systematic uncertainties and enables higher precision than previous measurement techniques. We present results obtained using our method.
△ Less
Submitted 14 October, 2016;
originally announced October 2016.
-
Position-sensitive detection of ultracold neutrons with an imaging camera and its implications to spectroscopy
Authors:
Wanchun Wei,
L. J. Broussard,
M. A. Hoffbauer,
M. Makela,
C. L. Morris,
Z. Tang,
E. R. Adamek,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
K. K. Leung,
C. -Y. Liu,
D. J. Morley,
Jose D. Ortiz,
R. W. Pattie, Jr.,
J. C. Ramsey,
A. Saunders,
S. J. Seestrom
, et al. (7 additional authors not shown)
Abstract:
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neu…
▽ More
Position-sensitive detection of ultracold neutrons (UCNs) is demonstrated using an imaging charge-coupled device (CCD) camera. A spatial resolution less than 15 $μ$m has been achieved, which is equivalent to an UCN energy resolution below 2 pico-electron-volts through the relation $δE = m_0g δx$. Here, the symbols $δE$, $δx$, $m_0$ and $g$ are the energy resolution, the spatial resolution, the neutron rest mass and the gravitational acceleration, respectively. A multilayer surface convertor described previously is used to capture UCNs and then emits visible light for CCD imaging. Particle identification and noise rejection are discussed through the use of light intensity profile analysis. This method allows different types of UCN spectroscopy and other applications.
△ Less
Submitted 12 May, 2016; v1 submitted 27 April, 2016;
originally announced April 2016.
-
UCN sources at external beams of thermal neutrons. An example of PIK reactor
Authors:
E. V. Lychagin,
V. A. Mityukhlyaev,
A. Yu. Muzychka,
G. V. Nekhaev,
V. V. Nesvizhevsky,
M. S. Onegin,
E. I. Sharapov,
A. V. Strelkov
Abstract:
We consider ultracold neutron (UCN) sources based on a new method of UCN production in superfluid helium (4He). The PIK reactor is chosen as a perspective example of the application of this idea, which consists of installing a 4He UCN source in a beam of thermal or cold neutrons and surrounding the source with a moderator-reflector, which plays the role of a source of cold neutrons (CNs) feeding t…
▽ More
We consider ultracold neutron (UCN) sources based on a new method of UCN production in superfluid helium (4He). The PIK reactor is chosen as a perspective example of the application of this idea, which consists of installing a 4He UCN source in a beam of thermal or cold neutrons and surrounding the source with a moderator-reflector, which plays the role of a source of cold neutrons (CNs) feeding the UCN source. The CN flux in the source can be several times larger than the incident flux, due to multiple neutron reflections from the moderator-reflector. We show that such a source at the PIK reactor would provide an order of magnitude larger density and production rate than an analogous source at the ILL reactor.
We estimate parameters of a 4He source with solid methane (CH4) or/and liquid deuterium (D2) moderator-reflector. We show that such a source with CH4 moderator-reflector at the PIK reactor would provide the UCN density of ~1x10^5 1/cm^3, and the UCN production rate of ~2x10^7 1/s. These values are respectively 1000 and 20 times larger than those for the most intense UCN user source. The UCN density in a source with D2 moderator-reflector would reach the value of ~2x10^5 1/cm^3, and the UCN production rate would be equal ~8x10^7 1/s. Installation of such sources in beams of CNs with equal flux would slightly increase the density and production rate.
△ Less
Submitted 24 November, 2015;
originally announced November 2015.
-
A multilayer surface detector for ultracold neutrons
Authors:
Zhehui Wang,
M. A. Hoffbauer,
C. L. Morris,
N. B. Callahan,
E. R. Adamek,
J. D. Bacon,
M. Blatnik,
A. E. Brandt,
L. J. Broussard,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
X. Ding,
J. Gao,
F. E. Gray,
K. P. Hickerson,
A. T. Holley,
T. M. Ito,
C. -Y. Liu,
M. Makela,
J. C. Ramsey,
R. W. Pattie, Jr.,
D. J. Salvat,
A. Saunders
, et al. (11 additional authors not shown)
Abstract:
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escap…
▽ More
A multilayer surface detector for ultracold neutrons (UCNs) is described. The top $^{10}$B layer is exposed to the vacuum chamber and directly captures UCNs. The ZnS:Ag layer beneath the $^{10}$B layer is a few microns thick, which is sufficient to detect the charged particles from the $^{10}$B(n,$α$)$^7$Li neutron-capture reaction, while thin enough so that ample light due to $α$ and $^7$Li escapes for detection by photomultiplier tubes. One-hundred-nm thick $^{10}$B layer gives high UCN detection efficiency, as determined by the mean UCN kinetic energy, detector materials and others. Low background, including negligible sensitivity to ambient neutrons, has also been verified through pulse-shape analysis and comparisons with other existing $^3$He and $^{10}$B detectors. This type of detector has been configured in different ways for UCN flux monitoring, development of UCN guides and neutron lifetime research.
△ Less
Submitted 24 April, 2015; v1 submitted 11 March, 2015;
originally announced March 2015.
-
Oklo reactors and implications for nuclear science
Authors:
E. D. Davis,
C. R. Gould,
E. I. Sharapov
Abstract:
We summarize the nuclear physics interests in the Oklo natural nuclear reactors, focusing particularly on developments over the past two decades. Modeling of the reactors has become increasingly sophisticated, employing Monte Carlo simulations with realistic geometries and materials that can generate both the thermal and epithermal fractions. The water content and the temperatures of the reactors…
▽ More
We summarize the nuclear physics interests in the Oklo natural nuclear reactors, focusing particularly on developments over the past two decades. Modeling of the reactors has become increasingly sophisticated, employing Monte Carlo simulations with realistic geometries and materials that can generate both the thermal and epithermal fractions. The water content and the temperatures of the reactors have been uncertain parameters. We discuss recent work pointing to lower temperatures than earlier assumed. Nuclear cross sections are input to all Oklo modeling and we discuss a parameter, the $^{175}$Lu ground state cross section for thermal neutron capture leading to the isomer $^{176\mathrm{m}}$ Lu, that warrants further investigation. Studies of the time dependence of dimensionless fundamental constants have been a driver for much of the recent work on Oklo. We critically review neutron resonance energy shifts and their dependence on the fine structure constant $α$ and the ratio $X_q=m_q/Λ$ (where $m_q$ is the average of the $u$ and $d$ current quark masses and $Λ$ is the mass scale of quantum chromodynamics). We suggest a formula for the combined sensitivity to $α$ and $X_q$ that exhibits the dependence on proton number $Z$ and mass number $A$, potentially allowing quantum electrodynamic and quantum chromodynamic effects to be disentangled if a broader range of isotopic abundance data becomes available.
△ Less
Submitted 19 April, 2014;
originally announced April 2014.
-
Storage of ultracold neutrons in the UCN$τ$ magneto-gravitational trap
Authors:
D. J. Salvat,
E. R. Adamek,
D. Barlow,
L. J. Broussard,
J. D. Bowman,
N. B. Callahan,
S. M. Clayton,
C. Cude-Woods,
S. Currie,
E. B. Dees,
W. Fox,
P. Geltenbort,
K. P. Hickerson,
A. T. Holley,
C. -Y. Liu,
M. Makela,
J. Medina,
D. J. Morley,
C. L. Morris,
S. I. Penttila,
J. Ramsey,
A. Saunders,
S. J. Seestrom,
S. K. L. Sjue,
B. A. Slaughter
, et al. (7 additional authors not shown)
Abstract:
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN los…
▽ More
The UCN$τ$ experiment is designed to measure the lifetime $τ_{n}$ of the free neutron by trap** ultracold neutrons (UCN) in a magneto-gravitational trap. An asymmetric bowl-shaped NdFeB magnet Halbach array confines low-field-seeking UCN within the apparatus, and a set of electromagnetic coils in a toroidal geometry provide a background "holding" field to eliminate depolarization-induced UCN loss caused by magnetic field nodes. We present a measurement of the storage time $τ_{store}$ of the trap by storing UCN for various times, and counting the survivors. The data are consistent with a single exponential decay, and we find $τ_{store}=860\pm19$ s: within $1 σ$ of current global averages for $τ_{n}$. The storage time with the holding field deactiveated is found to be $τ_{store}=470 \pm 160$ s; this decreased storage time is due to the loss of UCN which undergo Majorana spin-flips while being stored. We discuss plans to increase the statistical sensitivity of the measurement and investigate potential systematic effects.
△ Less
Submitted 31 October, 2013; v1 submitted 21 October, 2013;
originally announced October 2013.
-
The Upscattering of Ultracold Neutrons from the polymer $[C_6 H_{12}]_n$
Authors:
E. I. Sharapov,
C. L. Morris,
M. Makela,
A. Saunders,
Evan R. Adamek,
L. J. Broussard,
C. B. Cude-Woods,
Deion E Fellers,
Peter Geltenbort,
M. Hartl,
S. I. Hasan,
K. P. Hickerson,
G. Hogan,
A. T. Holley,
C. M. Lavelle,
Chen-Yu Liu,
M. P. Mendenhall,
J. Ortiz,
R. W. Pattie Jr.,
J. Ramsey,
D. J. Salvat,
S. J. Seestrom,
E. Shaw,
Sky Sjue,
W. E. Sondheim
, et al. (6 additional authors not shown)
Abstract:
It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the f…
▽ More
It is generally accepted that the main cause of ultracold neutron (UCN) losses in storage traps is the upscattering to the thermal energy range by hydrogen adsorbed on the surface of the trap walls. However, the data on which this conclusion is based are poor and contradictory. Here, we report a measurement, performed at the Los Alamos National Laboratory UCN source, of the average energy of the flux of upscattered neutrons after the interaction of UCN with hydrogen bound in semicrystalline polymer PMP (tradename TPX), [C$_{6}$H$_{12}$]$_n$. Our analysis, performed with the MCNP code based on the application of the neutron scattering law to UCN upscattered by bound hydrogen in semicrystalline polyethylene, [C$_{2}$H$_{4}$]$_n$, leads us to a flux average energy value of 26$\pm3$ meV in contradiction with previously reported experimental values of 10 to 13 meV and in agreement with the theoretical models of neutron heating implemented in the MCNP code.
△ Less
Submitted 12 August, 2013;
originally announced August 2013.
-
Measurements of ultracold neutron upscattering and absorption in polyethylene and vanadium
Authors:
E. I. Sharapov,
C. L. Morris,
M. Makela,
A. Saunders,
Evan R. Adamek,
Yelena Bagdasarova,
L. J. Broussard,
C. B. Cude-Woods,
Deon E Fellers,
Peter Geltenbort,
S. I. Hasan,
K. P. Hickerson,
G. Hogan,
A. T. Holley,
Chen-Yu Liu,
M. P. Mendenhall,
J. Ortiz,
R. W. Pattie Jr.,
D. G. Phillips,
J. Ramsey,
D. J. Salvat,
S. J. Seestrom,
E. Shaw,
Sky Sjue,
W. E. Sondheim
, et al. (5 additional authors not shown)
Abstract:
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree bet…
▽ More
The study of neutron cross sections for elements used as efficient ``absorbers'' of ultracold neutrons (UCN) is crucial for many precision experiments in nuclear and particle physics, cosmology and gravity. In this context, ``absorption'' includes both the capture and upscattering of neutrons to the energies above the UCN energy region. The available data, especially for hydrogen, do not agree between themselves or with the theory. In this report we describe measurements performed at the Los Alamos National Laboratory UCN facility of the UCN upscattering cross sections for vanadium and for hydrogen in CH$_2$ using simultaneous measurements of the radiative capture cross sections for these elements. We measured $σ_{up}=1972\pm130$ b for hydrogen in CH$_2$, which is below theoretical expectations, and $σ_{up} < 25\pm9$ b for vanadium, in agreement with the expectation for the neutron heating by thermal excitations in solids.
△ Less
Submitted 5 June, 2013;
originally announced June 2013.
-
Gamma-ray fluxes in Oklo natural reactors
Authors:
C. R. Gould,
E. I. Sharapov,
A. A. Sonzogni
Abstract:
Uncertainty in the operating temperatures of Oklo reactor zones impacts the precision of bounds derived for time variation of the fine structure constant $α$. Improved $^{176}$Lu/$^{175}$Lu thermometry has been discussed but its usefulness may be complicated by photo excitation of the isomeric state $^{176m}$Lu by $^{176}$Lu($γ,γ^\prime $) fluorescence. We calculate prompt, delayed and equilibrium…
▽ More
Uncertainty in the operating temperatures of Oklo reactor zones impacts the precision of bounds derived for time variation of the fine structure constant $α$. Improved $^{176}$Lu/$^{175}$Lu thermometry has been discussed but its usefulness may be complicated by photo excitation of the isomeric state $^{176m}$Lu by $^{176}$Lu($γ,γ^\prime $) fluorescence. We calculate prompt, delayed and equilibrium $γ$-ray fluxes due to fission of $^{235}$U in pulsed mode operation of Oklo zone RZ10. We use Monte Carlo modeling to calculate the prompt flux. We use improved data libraries to estimate delayed and equilibrium spectra and fluxes. We find $γ$-ray fluxes as a function of energy and derive values for the coefficients $λ_{γ,γ^\prime}$ that describe burn-up of $^{176}$Lu through the isomeric $^{176m}$Lu state. The contribution of the ($γ,γ^\prime $) channel to the $^{176}$Lu/$^{175}$Lu isotopic ratio is negligible in comparison to the neutron burn-up channels. Lutetium thermometry is fully applicable to analyses of Oklo reactor data.
△ Less
Submitted 21 November, 2012;
originally announced November 2012.
-
Precision Measurement of the Neutron Beta-Decay Asymmetry
Authors:
M. P. Mendenhall,
R. W. Pattie Jr,
Y. Bagdasarova,
D. B. Berguno,
L. J. Broussard,
R. Carr,
S. Currie,
X. Ding,
B. W. Filippone,
A. García,
P. Geltenbort,
K. P. Hickerson,
J. Hoagland,
A. T. Holley,
R. Hong,
T. M. Ito,
A. Knecht,
C. -Y. Liu,
J. L. Liu,
M. Makela,
R. R. Mammei,
J. W. Martin,
D. Melconian,
S. D. Moore,
C. L. Morris
, et al. (16 additional authors not shown)
Abstract:
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, co…
▽ More
A new measurement of the neutron $β$-decay asymmetry $A_0$ has been carried out by the UCNA collaboration using polarized ultracold neutrons (UCN) from the solid deuterium UCN source at the Los Alamos Neutron Science Center (LANSCE). Improvements in the experiment have led to reductions in both statistical and systematic uncertainties leading to $A_0 = -0.11954(55)_{\rm stat.}(98)_{\rm syst.}$, corresponding to the ratio of axial-vector to vector coupling $λ\equiv g_A/g_V = -1.2756(30)$.
△ Less
Submitted 19 February, 2013; v1 submitted 25 October, 2012;
originally announced October 2012.
-
La138/139 Isotopic Data and Neutron Fluences for Oklo RZ10 Reactor
Authors:
C. R. Gould,
E. I. Sharapov
Abstract:
Recent years have seen a renewed interest in the Oklo phenomenon, particularly in relation to the study of time variation of the fine structure constant. The neutron fluence is one of the crucial parameters for Oklo reactors. Several approaches to its determination were elaborated in the past. We consider whether it possible to use the present isotopic La138/139 data for RZ10 as an additional indi…
▽ More
Recent years have seen a renewed interest in the Oklo phenomenon, particularly in relation to the study of time variation of the fine structure constant. The neutron fluence is one of the crucial parameters for Oklo reactors. Several approaches to its determination were elaborated in the past. We consider whether it possible to use the present isotopic La138/139 data for RZ10 as an additional indicator of neutron fluences in the active cores of the reactors. We calculate the dependence of the Oklo La138 abundance on neutron fluence and elemental lanthanum concentration. The neutron fluence in RZ10 can be deduced from lanthanum isotopic data, but requires reliable data on the primordial elemental abundance. Conversely, if the fluence is known, the isotope ratio provides information on the primordial lanthanum abundance that is not otherwise easily determined.
△ Less
Submitted 23 August, 2012;
originally announced August 2012.
-
Lutetium thermometry for Oklo natural reactors: a new look at old data
Authors:
C. R. Gould,
E. I. Sharapov
Abstract:
Lutetium thermometry has been used to analyze Oklo natural nuclear reactor zones but leads to widely varying and puzzling predictions for the temperatures $T_O$ which in turn impacts bounds on time variation of the fine structure constant $α$. We revisit results for reactor zone RZ10 in light of new measurements of the isomer branching ratio $B^g$ in $^{175}$Lu neutron capture at 5 and 25 keV. We…
▽ More
Lutetium thermometry has been used to analyze Oklo natural nuclear reactor zones but leads to widely varying and puzzling predictions for the temperatures $T_O$ which in turn impacts bounds on time variation of the fine structure constant $α$. We revisit results for reactor zone RZ10 in light of new measurements of the isomer branching ratio $B^g$ in $^{175}$Lu neutron capture at 5 and 25 keV. We recalculate predictions for $T_O$ as a function of $B^g$ using realistic models of the Oklo neutron flux. We find $T_O = 100 \pm 30$ C using a new value of $B^g$, in contrast to $350 < T_O < 500 $ C using the evaluated value at thermal energy. Lutetium thermometry can be applicable to analyses of Oklo reactor data, but a better measurement of $B^g$ with thermal neutrons is needed to confirm the reliability of temperature predictions.
△ Less
Submitted 16 February, 2012;
originally announced February 2012.
-
Time-variability of alpha from realistic models of Oklo reactors
Authors:
C. R. Gould,
E. I. Sharapov,
S. K. Lamoreaux
Abstract:
We reanalyze Oklo $^{149}$Sm data using realistic models of the natural nuclear reactors. Disagreements among recent Oklo determinations of the time evolution of $α$, the electromagnetic fine structure constant, are shown to be due to different reactor models, which led to different neutron spectra used in the calculations. We use known Oklo reactor epithermal spectral indices as criteria for se…
▽ More
We reanalyze Oklo $^{149}$Sm data using realistic models of the natural nuclear reactors. Disagreements among recent Oklo determinations of the time evolution of $α$, the electromagnetic fine structure constant, are shown to be due to different reactor models, which led to different neutron spectra used in the calculations. We use known Oklo reactor epithermal spectral indices as criteria for selecting realistic reactor models. Two Oklo reactors, RZ2 and RZ10, were modeled with MCNP. The resulting neutron spectra were used to calculate the change in the $^{149}$Sm effective neutron capture cross section as a function of a possible shift in the energy of the 97.3-meV resonance. We independently deduce ancient $^{149}$Sm effective cross sections, and use these values to set limits on the time-variation of $α$. Our study resolves a contradictory situation with previous Oklo $α$-results. Our suggested $2 σ$ bound on a possible time variation of $α$ over two billion years is stringent: $ -0.24 \times 10^{-7} \le \frac{Δα}α \le 0.11 \times 10^{-7}$, but model dependent in that it assumes only $α$ has varied over time.
△ Less
Submitted 30 April, 2007; v1 submitted 11 January, 2007;
originally announced January 2007.
-
Upper Bounds on Parity Violating Gamma-Ray Asymmetries in Compound Nuclei from Polarized Cold Neutron Capture
Authors:
M. T. Gericke,
J. D. Bowman,
R. D. Carlini,
T. E. Chupp,
K. P. Coulter,
M. Dabaghyan,
M. Dawkins,
D. Desai,
S. J. Freedman,
T. R. Gentile,
R. C. Gillis,
G. L. Greene,
F. W. Hersman,
T. Ino,
G. L. Jones,
M. Kandes,
B. Lauss,
M. Leuschner,
W. R. Lozowski,
R. Mahurin,
M. Mason,
Y. Masuda,
G. S. Mitchell,
S. Muto,
H. Nann
, et al. (11 additional authors not shown)
Abstract:
Parity-odd asymmetries in the electromagnetic decays of compound nuclei can sometimes be amplified above values expected from simple dimensional estimates by the complexity of compound nuclear states. In this work we use a statistical approach to estimate the root mean square (RMS) of the distribution of expected parity-odd correlations $\vec{s_{n}} \cdot \vec{k_γ}$, where $\vec {s_{n}}$ is the…
▽ More
Parity-odd asymmetries in the electromagnetic decays of compound nuclei can sometimes be amplified above values expected from simple dimensional estimates by the complexity of compound nuclear states. In this work we use a statistical approach to estimate the root mean square (RMS) of the distribution of expected parity-odd correlations $\vec{s_{n}} \cdot \vec{k_γ}$, where $\vec {s_{n}}$ is the neutron spin and $\vec{k_γ}$ is the momentum of the gamma, in the integrated gamma spectrum from the capture of cold polarized neutrons on Al, Cu, and In and we present measurements of the asymmetries in these and other nuclei. Based on our calculations, large enhancements of asymmetries were not predicted for the studied nuclei and the statistical estimates are consistent with our measured upper bounds on the asymmetries.
△ Less
Submitted 3 August, 2006;
originally announced August 2006.
-
Measurement of parity-nonconserving rotation of neutron spin in the 0.734-eV p-wave resonance of $^{139}La$
Authors:
T. Haseyama,
K. Asahi,
J. D. Bowman,
P. P. J. Delheij,
H. Funahashi,
S. Ishimoto,
G. Jones,
A. Masaike,
Y. Masuda,
Y. Matsuda,
K. Morimoto,
S. Muto,
S. I. Penttilä,
V. R. Pomeroy,
K. Sakai,
E. I. Sharapov,
D. A. Smith,
V. W. Yuan
Abstract:
The parity nonconserving spin rotation of neutrons in the 0.734-eV p-wave resonance of $^{139}La$ was measured with the neutron transmission method. Two optically polarized $^3He$ cells were used before and behind a a 5-cm long $^{139}La$ target as a polarizer and an analyzer of neutron spin. The rotation angle was carefully measured by flip** the direction of $^3He$ polarization in the polari…
▽ More
The parity nonconserving spin rotation of neutrons in the 0.734-eV p-wave resonance of $^{139}La$ was measured with the neutron transmission method. Two optically polarized $^3He$ cells were used before and behind a a 5-cm long $^{139}La$ target as a polarizer and an analyzer of neutron spin. The rotation angle was carefully measured by flip** the direction of $^3He$ polarization in the polarizer in sequence. The peak-to-peak value of the spin rotation was found to be $ (7.4 \pm 1.1) \times 10^{-3} $ rad/cm which was consistent with the previous experiments. But the result was statisticallly improved. The s-p mixing model gives the weak matrix element as $xW = (1.71 \pm 0.25)$ meV. The value agrees well with the one deduced from the parity-nonconserving longitudinal asymmetry in the same resonance.
△ Less
Submitted 21 November, 2001;
originally announced November 2001.
-
Progress toward a new measurement of the parity violating asymmetry in n+p-->d+gamma
Authors:
W. M. Snow,
W. S. Wilburn,
J. D. Bowman,
M. B. Leuschner,
S. I. Penttila,
V. R. Pomeroy,
D. R. Rich,
E. I. Sharapov,
V. Yuan
Abstract:
We outline the motivation and conceptual design for a new experiment aimed at a 10-fold improvement in the accuracy of the parity-violating asymmetry A_gamma in the angular distribution of 2.2 MeV gamma rays from the n+p-->d+gamma reaction. This observable is primarily sensitive to the weak pion-nucleon coupling H_pi^1. A proof-of-principle experiment using unpolarized low-energy neutron capture…
▽ More
We outline the motivation and conceptual design for a new experiment aimed at a 10-fold improvement in the accuracy of the parity-violating asymmetry A_gamma in the angular distribution of 2.2 MeV gamma rays from the n+p-->d+gamma reaction. This observable is primarily sensitive to the weak pion-nucleon coupling H_pi^1. A proof-of-principle experiment using unpolarized low-energy neutron capture on polyethylene and an array of 12 CsI detectors operated in current mode has been performed. Results of this test experiment including the current mode signal, electronic noise and detector sensitivity to magnetic fields are reported.
△ Less
Submitted 1 April, 1998;
originally announced April 1998.