-
Result of the MICROSCOPE Weak Equivalence Principle test
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Joel Bergé,
Alain Robert,
Quentin Baghi,
Yves André,
Judicaël Bedouet,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Louis Demange,
Hansjoerg Dittus,
Océane Dhuicque,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh
, et al. (22 additional authors not shown)
Abstract:
The space mission MICROSCOPE dedicated to the test of the Equivalence Principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations ($a_{\rm A}$ and $a_{\rm B}$) of two test masses in terms of the Eötvös parameter $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$. No EP violation…
▽ More
The space mission MICROSCOPE dedicated to the test of the Equivalence Principle (EP) operated from April 25, 2016 until the deactivation of the satellite on October 16, 2018. In this analysis we compare the free-fall accelerations ($a_{\rm A}$ and $a_{\rm B}$) of two test masses in terms of the Eötvös parameter $η({\rm{A, B}}) = 2 \frac{a_{\rm A}- a_{\rm B}}{a_{\rm A}+ a_{\rm B}}$. No EP violation has been detected for two test masses, made from platinum and titanium alloys, in a sequence of 19 segments lasting from 13 to 198 hours down to the limit of the statistical error which is smaller than $10^{-14}$ for $ η({\rm{Ti, Pt}})$. Accumulating data from all segments leads to $η({\rm{Ti, Pt}}) =[-1.5\pm{}2.3{\rm (stat)}\pm{}1.5{\rm (syst)}] \times{}10^{-15}$ showing no EP violation at the level of $2.7\times{}10^{-15}$ if we combine stochastic and systematic errors quadratically. This represents an improvement of almost two orders of magnitude with respect to the previous best such test performed by the Eöt-Wash group. The reliability of this limit has been verified by comparing the free falls of two test masses of the same composition (platinum) leading to a null Eötvös parameter with a statistical uncertainty of $1.1\times{}10^{-15}$.
△ Less
Submitted 30 September, 2022;
originally announced September 2022.
-
MICROSCOPE mission: final results of the test of the Equivalence Principle
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Joel Bergé,
Alain Robert,
Quentin Baghi,
Yves André,
Judicaël Bedouet,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Louis Demange,
Hansjoerg Dittus,
Océane Dhuicque,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh
, et al. (22 additional authors not shown)
Abstract:
The MICROSCOPE mission was designed to test the Weak Equivalence Principle (WEP), stating the equality between the inertial and the gravitational masses, with a precision of $10^{-15}$ in terms of the Eötvös ratio $η$. Its experimental test consisted of comparing the accelerations undergone by two collocated test masses of different compositions as they orbited the Earth, by measuring the electros…
▽ More
The MICROSCOPE mission was designed to test the Weak Equivalence Principle (WEP), stating the equality between the inertial and the gravitational masses, with a precision of $10^{-15}$ in terms of the Eötvös ratio $η$. Its experimental test consisted of comparing the accelerations undergone by two collocated test masses of different compositions as they orbited the Earth, by measuring the electrostatic forces required to keep them in equilibrium. This was done with ultra-sensitive differential electrostatic accelerometers onboard a drag-free satellite. The mission lasted two and a half years, cumulating five-months-worth of science free-fall data, two thirds with a pair of test masses of different compositions -- Titanium and Platinum alloys -- and the last third with a reference pair of test masses of the same composition -- Platinum. We summarize the data analysis, with an emphasis on the characterization of the systematic uncertainties due to thermal instabilities and on the correction of short-lived events which could mimic a WEP violation signal. We found no violation of the WEP, with the Eötvös parameter of the Titanium and Platinum pair constrained to $η({\rm Ti, Pt})~=~ [-1.5 \pm 2.3~{\rm (stat)} \pm 1.5~{\rm (syst)}]~\times 10^{-15}$ at $1σ$ in statistical errors.
△ Less
Submitted 30 September, 2022;
originally announced September 2022.
-
MICROSCOPE mission: Data analysis principle
Authors:
Joel Bergé,
Quentin Baghi,
Emilie Hardy,
Gilles Métris,
Alain Robert,
Manuel Rodrigues,
Pierre Touboul,
Ratana Chhun,
Pierre-Yves Guidotti,
Sandrine Pires,
Serge Reynaud,
Laura Serron,
Jean-Michel Travert
Abstract:
After performing highly sensitive acceleration measurements during two years of drag-free flight around the Earth, MICROSCOPE provided the best constraint on the Weak Equivalence Principle (WEP) to date. Beside being a technological challenge, this experiment required a specialised data analysis pipeline to look for a potential small signal buried in the noise, possibly plagued by instrumental def…
▽ More
After performing highly sensitive acceleration measurements during two years of drag-free flight around the Earth, MICROSCOPE provided the best constraint on the Weak Equivalence Principle (WEP) to date. Beside being a technological challenge, this experiment required a specialised data analysis pipeline to look for a potential small signal buried in the noise, possibly plagued by instrumental defects, missing data and glitches. This paper describes the frequency-domain iterative least-square technique that we developed for MICROSCOPE. In particular, using numerical simulations, we prove that our estimator is unbiased and provides correct error bars. This paper therefore justifies the robustness of the WEP measurements given by MICROSCOPE.
△ Less
Submitted 22 December, 2020; v1 submitted 11 December, 2020;
originally announced December 2020.
-
Space test of the Equivalence Principle: first results of the MICROSCOPE mission
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Quentin Baghi,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Hansjoerg Dittus,
Pierre Fayet,
Bernard Foulon,
Pierre-Yves Guidotti,
Emilie Hardy,
Phuong-Anh Huynh,
Claus Lämmerzahl,
Vincent Lebat,
Françoise Liorzou,
Meike List,
Isabelle Panet,
Sandrine Pires
, et al. (9 additional authors not shown)
Abstract:
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different co…
▽ More
The Weak Equivalence Principle (WEP), stating that two bodies of different compositions and/or mass fall at the same rate in a gravitational field (universality of free fall), is at the very foundation of General Relativity. The MICROSCOPE mission aims to test its validity to a precision of $10^{-15}$, two orders of magnitude better than current on-ground tests, by using two masses of different compositions (titanium and platinum alloys) on a quasi-circular trajectory around the Earth. This is realised by measuring the accelerations inferred from the forces required to maintain the two masses exactly in the same orbit. Any significant difference between the measured accelerations, occurring at a defined frequency, would correspond to the detection of a violation of the WEP, or to the discovery of a tiny new type of force added to gravity. MICROSCOPE's first results show no hint for such a difference, expressed in terms of Eötvös parameter $δ(Ti,Pt)=[-1\pm{}9{\rm (stat)}\pm{}9{\rm (syst)}] \times{}10^{-15}$ (both 1$σ$ uncertainties) for a titanium and platinum pair of materials. This result was obtained on a session with 120 orbital revolutions representing 7\% of the current available data acquired during the whole mission. The quadratic combination of 1$σ$ uncertainties leads to a current limit on $δ$ of about $1.3\times{}10^{-14}$.
△ Less
Submitted 23 September, 2019;
originally announced September 2019.
-
The MICROSCOPE mission: first results of a space test of the Equivalence Principle
Authors:
Pierre Touboul,
Gilles Métris,
Manuel Rodrigues,
Yves André,
Quentin Baghi,
Joel Bergé,
Damien Boulanger,
Stefanie Bremer,
Patrice Carle,
Ratana Chhun,
Bruno Christophe,
Valerio Cipolla,
Thibault Damour,
Pascale Danto,
Hansjoerg Dittus,
Pierre Fayet,
Bernard Foulon,
Claude Gageant,
Pierre-Yves Guidotti,
Daniel Hagedorn,
Emilie Hardy,
Phuong-Anh Huynh,
Henri Inchauspe,
Patrick Kayser,
Stéphanie Lala
, et al. (18 additional authors not shown)
Abstract:
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of…
▽ More
According to the Weak Equivalence Principle, all bodies should fall at the same rate in a gravitational field. The MICROSCOPE satellite, launched in April 2016, aims to test its validity at the $10^{-15}$ precision level, by measuring the force required to maintain two test masses (of titanium and platinum alloys) exactly in the same orbit. A non-vanishing result would correspond to a violation of the Equivalence Principle, or to the discovery of a new long-range force. Analysis of the first data gives $δ\rm{(Ti,Pt)}= [-1 \pm 9 (\mathrm{stat}) \pm 9 (\mathrm{syst})] \times 10^{-15}$ (1$σ$ statistical uncertainty) for the titanium-platinum Eötvös parameter characterizing the relative difference in their free-fall accelerations.
△ Less
Submitted 6 December, 2017; v1 submitted 4 December, 2017;
originally announced December 2017.